Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSProperty Information
Owner:Scott Decker
Address:5911 Eastwood Drive
Fort Pierce, FL 34951
Building Information
Wind Zone:160 MPH.
Exposure Category:C
Minimum Building Dimension:30 ft.
Mean Roof Height:12 ft.
Risk Category:II
Design Pressure Calculations
Opening
Number
Location
Zone
Device
Width (in)
Device
Height (in)
Device
Elevation (ft)
Max Positive
Pressure (psf)
Max Negative
Pressure (psf)
1 End 37 63 7 32.4 -42.7
2 End 37 63 7 32.4 -42.7
3 End 53 26 7 33.5 -44.8
4 End 53 26 7 33.5 -44.8
5 End 53 26 7 33.5 -44.8
6 End 53 63 7 31.6 -41.2
7 End 137 79 7 29.1 -36.1
8 End 70 79 7 30.6 -39.0
9 End 26 26 7 33.5 -44.8
10 End 26 26 7 33.5 -44.8
11 End 37 63 7 32.4 -42.7
12 End 37 63 7 32.4 -42.7
Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code.
Page 1 of 1