DESIGN PRESSURE CALCULATIONS
Property Information Owner:Scott Decker Address:5911 Eastwood Drive Fort Pierce, FL 34951 Building Information Wind Zone:160 MPH. Exposure Category:C Minimum Building Dimension:30 ft. Mean Roof Height:12 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 37 63 7 32.4 -42.7 2 End 37 63 7 32.4 -42.7 3 End 53 26 7 33.5 -44.8 4 End 53 26 7 33.5 -44.8 5 End 53 26 7 33.5 -44.8 6 End 53 63 7 31.6 -41.2 7 End 137 79 7 29.1 -36.1 8 End 70 79 7 30.6 -39.0 9 End 26 26 7 33.5 -44.8 10 End 26 26 7 33.5 -44.8 11 End 37 63 7 32.4 -42.7 12 End 37 63 7 32.4 -42.7 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1