HomeMy WebLinkAboutBUILDING PERMIT APPLICATIONAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date; 6/30/21 Permit Number;
Building-PermittApplica.tion_-.
Planning and Development Services
Building and Code Regulation Di vision Commercial Residential X
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772)462-1553 Fax: (772) 4624578
PERMIT APPLICATION FOR:
Address
3405 industrial 31st
Project Name: Tomaria LLC
LIKE FOR LIKE A/C CHANGE OUT new mini split
9000 btu, 17 seer no kw
work attached
New Electrical Meter Second Electrical Meter.
Additional worl<to be performed uttderthls permit— check all that apply:
Mechanical _Gas Tank Gas Piping _Shutters
Electric _Plumbing _Sprinklers _Generator
Total Sq. Ft of Construction:
Cost of Construction: $ 5088.00
Tomaria LLC
Sq, Ft, of First Floor:
Windows/Doors _ Pond
Roof _ _ Pitch
Utilities: _Sewer ^,Septic Building Height:
Address: 1550 thumb point dr
city: fort pierce State: fl
Zip Code: 34949 Fax:
Phone No.772-323-4885
Fill in fee simple Title Holder on next page (if different
from the Owner listed above)
Name: Christopher Langel _
company: Sea Coast A/C and Sheet Metal Inc.
Address: 3108 Industrial 31 st Street
city: Ft Pierce state: FL
Zip
Ph
Code: 34946 Fax: 772-448-4416
one No 772-466-2400
E-Mail info seacoastair com
State or County License CMC035421
nFrnenKn Nnticp of commencement is required.
If value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required.
MORTGAGE COMPANY: _ Not Applicable
Name:
Address: _ Address:
City: State: City:
FEE SIMPLETITLE HOLDER: _ Not Applicable BONDING COMPANY: _Not Applicable
Name: Name:
Address: Address:
City: City:
Zip: Phone:. Zip: Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application Is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the Issuance of a permlU
St. Lucie County makes no representation that is granting a pemtitwill authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws aimandcovenants that may restrict or its uch
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
--1n-consideration of the -granting of this requested permit, I.do hereby agree thgt.l_will, In all.respects, perform_the work,
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for
improvements to your property. A Notice of Commencement must be recorded in the public records of t.
Lucie County and posted on the jobsite before the first inspection. If you intend to obtain financing, consult
with lender or an attorney before commencing work or recording your Noce of Commencement.
Owner/ Lessee/Contractor as Agent for Owner
STATE OF FLO I P
COUNTY OF��nLQC,{
Sworn
to (or affirmed) and subscribed before me of
., Physical Presence or Online Notarization
this 30 day of jymrlq, 202( by
P hri �-k»h>° L L vio, e l
Name of person m king statement.
Personally Known X. OR Produced Identification
Type of Identification
,{ISignature of Notary P
Commission No.
REVIEWS FR(
COU
JU3TINAL, NOPKINS
STATE OF FLO
COUNTY OF r a �
S o'n to (or affirmed) and subscribed before me of
Physical Presence or_ Online Notarization
tnis In day of june , 20 by
C.h.n'S Phu I �q4I
Name of person making
statement. `J
Personally Known x OR Produced Identification
Type of Identification
of Notary Public- Statdlof Florida
VEGETAl10N
REVIEW
0 ;0 0 1 is
AHRI Certified Reference Number : 205782844 Date : 06-30-2021 Model Status :Active
AHRI Type : RCU-A-CB-0 (Mini -Split Air -Conditioner, with Remote Outdoor Unit -Air -Source, Free Delivery)
Outdoor Unit Brand Name: DAIKIN
Outdoor Unit Model Number: RK09AXVJU
Indoor Type : Mini -Splits (Non -Ducted)
Indoor Model Number(s) : FTK09AXVJU
Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1, Performance Rating of Unitary
Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing:
Cooling Capacity (95F) : 8900
EER (95F) : 12.50
SEER: 19.00
Sold in? : USA, Canada
}"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being
marketed but are not yet heing produced:'Production Stopped" Modei Status are those that an AHRI Cerifcation Program Participant is no longer producing BUT is still
RaIling or offering for sale.
tings that are accompanied by WAS indicate an involuntary re -rate. The new published rating Is shown alone with the previous (i.e. WAS) rating.
DISCLAIMER
AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the
unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the
directory at www,alirld lrectory.org,
TERMS AND CONDITIONS
This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and
confidential reference purposes. The contents of this Certificate may not, in whole or In part, be reproduced; copied; disseminated; AM
entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's Individual,
personal and confidential reference. AIR-CONDITIONING, HEATING,
CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE
The Information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link we make life better'
and enter the AHRI Certified Reference Number and the date on which the certificate was issued,
which is listed above, and the Certificate No., which Is listed at bottom right.
92021 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 32695251825727972
For: Tomaria LLC
3405 Industrial 31st Street, Fort Pierce, FL 34946
Notes: 3405 Industrial 31 st Street, Fo t Pierce, 34946
W = ee WON Des UI`1I lM0rmatjon : :. .
Weather: Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 95 OF
Inside db 70 OF Inside db 75 OF
Design TD 28 OF Design TD 20 OF
Daily range M
Relative humidity 50 %
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 3555 Btuh Structure 4411 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 11 Btuh Blower 1707 Bluth
Piping 0 Btuh
Equipment load 3567 Bluh Use manufacturers data n
Rate/swingg multipplier 1.00
Infiltration Equipmentsensibleload 6118 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2378 Bluth
Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh
Heatingg Coolingg (none)
Area (ft') 180 180 Equipment latent load 2378 Btuh
Volume (it) 1440 1440
Airchangqes/hour 0.61 0.32 Equipment Total Load (Sen+Lat) 8496 Btuh
Equiv.AVF (cfm) 15 8 Req. total capacity at 0,70 SHR 0.7 ton
Heating Equipment Summary Cooling Equipment Summary
Make n/a Make Daikin
Trade n/a Trade Daikin
Model n/a Cond RK09AXVJU
AHRI ref n/a Coil FTK09AXJU
AHRI ref 205782844
Efficiency n/a Efficiency 12.5 EER, 19 SEER
Heating input 0 Btuh Sensible cooling 6230 Btuh
Heating output 0 Btuh Latent cooling 2670 Btuh
Temperature rise 0 OF Total cooling 8900 Btuh
Actual air flow 201 cftn Actual air flow 201 cfrn
Air flow factor 0.056 cfm/Btuh Air flow factor 0,045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.72
Boldrtalic values have been manually ovemdden
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
I��',� htsofY, 2021Ju}30 07 33 03
RI9fR-Sule®Urvversa1201919.0.13 RSU26644 Pago1
MCA C:1Users�aversaU3esMopU.odiwnod elo h.rup CaIc=MJ6 Frord floor faces: N
For: Tomaria LLC
3405Industrial 31st Street, Fort Pierce, FL 34946
Outdoor design DB:
95.0°F
Sensible gain:
6118
Btuh Entering coil DB; 82.9°F
Outdoor design WB:
78.0°F
Latent gain:
2378
Btuh Entering coil WB: 652°F
ndoor design OR
75.0°F
Total gain:
8496
Btuh
Indoor RH:
50%
Estimated airflow:
201
cfm
Manufacturer's Performance Data at Actual Dosign Conditions
Equipment typo:
SpIitAC
Manufacturer:
Daikin
Actual airflow:
'201
cfm
Sensible capacity:
6230
Btuh
Latent capacity:
2670
Btuh
Total capacity:
8900
Btuh
Model: RK09AXVJU+FTK09AXJU
102% of load
112%of load
105%of load SHR: 70 %
Outdoor design DB: 42.0°F Heat loss: 3567 Btuh
Indoor design DB: 70.0°F
Manufacturer's Performanco Data at Actual Design Conditions
Equipment type:
Manufacturer: Model:
Actual airflow: 201 cfm
Output capacity: 0 Btuh 0%of load
Meets all requirements ofACCA Manual S.
Entering coil DB: 0°F
Temp. rise: 0 °F
l� WYICPubs Oft" 2021-Ju*300/:3303
/CCA C:\UserslaversaV)esMopLLockWootl alock.rup CaIc=MJB Front Door faces: N