HomeMy WebLinkAboutAPPROVED Metula Digital LetterArchitectonic Inc St. Lucie County Building Department Planning; & Development Services Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982 June 11, 2021 RE: 103 Queens Road, Fort Pierce, FL 34949 To Whcm It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed windows and mullion are incompliance with the 2020 Florida Building Code, 165 mph wind zone, exposure "C", risk category II. Exposure "C" Multiplier for 20' mean roof height is 1.29 Wind Zone 4 30.5 x 1.29= 39.3 Wind Zone 5 36.7 x 1.29 = 47.4 Required Design Pressures: +/-47.4 Product: Design Pressure: -170 Produce:: PGT Industries, Clipped Extruded Mullion, NOA# 20-0406.03 Product: Design Pressure: -70 Product:: PGT Industries, SH 500 PVC Window, NOA# 20-0401.03 Produce: Design Pressure: -110 Produce:: PGT Industries, Picture Window Fixed 5520, NOA# 20-0401.06 ............ R Respectfully Submitted, "A E,LFA�9 Michael Seal 2021.06.11 AR968-8' 13:06:50-04'00' srFRED.... Michael Seal, AIA AR96898 Architectonic, Inc. 806 Delaware Avenue Tel: 772 460 775`. www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1