HomeMy WebLinkAboutcompaction test Aspire Lot 24-digiUES Project No:
Workorder No:
Report Date:
3310.2100034.0000
237993-1
06/30/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:K. HOVNANIAN HOMES UES Technician:Nakia Sutton
3601 Quantum Blvd.
Boynton Beach, FL 33426
Date Tested:06/29/2021
Project:CMT/CSD Aspire at Waterstone
5130 Armina Place, Ft. Pierce, St. Lucie County, FL 34951
Type of Test:
Area Tested: Lot 24 - 5130 Armina Place, Ft Pierce Field:ASTM D-6938 Nuclear Gauge Method
Material:Fill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 NE Corner 0-1 ft 120.1 10.9 117.8 9.6 98 Pass
2 SW Corner 0-1 ft 120.1 10.9 118.0 10.1 98 Pass
3 Center 0-1 ft 120.1 10.9 118.5 10.6 99 Pass
Remarks:Permit: 2104-0689
Reviewed By
GFA International, Inc
FBPE Registry No.4930
John Kent, P.E.
Senior Project Engineer
STATE OF FLORIDA
Professional Engineer No. 63218
This item has been digitally signed and sealed by John Kent on
the date adjacent to the seal. Printed copies of this document are
not considered signed and sealed and the signature must be
verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1