Loading...
HomeMy WebLinkAboutcompaction test Aspire Lot 24-digiUES Project No: Workorder No: Report Date: 3310.2100034.0000 237993-1 06/30/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:K. HOVNANIAN HOMES UES Technician:Nakia Sutton 3601 Quantum Blvd. Boynton Beach, FL 33426 Date Tested:06/29/2021 Project:CMT/CSD Aspire at Waterstone 5130 Armina Place, Ft. Pierce, St. Lucie County, FL 34951 Type of Test: Area Tested: Lot 24 - 5130 Armina Place, Ft Pierce Field:ASTM D-6938 Nuclear Gauge Method Material:Fill Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Fill The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 NE Corner 0-1 ft 120.1 10.9 117.8 9.6 98 Pass 2 SW Corner 0-1 ft 120.1 10.9 118.0 10.1 98 Pass 3 Center 0-1 ft 120.1 10.9 118.5 10.6 99 Pass Remarks:Permit: 2104-0689 Reviewed By GFA International, Inc FBPE Registry No.4930 John Kent, P.E. Senior Project Engineer STATE OF FLORIDA Professional Engineer No. 63218 This item has been digitally signed and sealed by John Kent on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1