HomeMy WebLinkAboutAPPROVED COMER SUPPORTING DOCSWHY CHOOSE QUALITY STEEL
UNDERGROUND TANKS?
• 120 - 1,990 WG CAPACITY
• General Specifications
• Conforms to the latest edition of ASME Rules for Construction of
Pressure Vessels, Section VIII, Division 1.
• Complies with NFPA 58.
• Rated at 250 psig from -20' F to 125" F. All vessels registered
with National Board,
• Two service options available:
• Option 1: Ready -to -bury underground option, coated with
either powder coated phenolic epoxy finish or liquid applied
epoxy primer coat followed by urethane top coat, supplied
with composite AGIUG dome
• Option 2: Aboveground option, coated with either powder coated
TGIC polyester finish or liquid applied epoxy primer coat followed
by urethane top coat, supplied with steel AGIUG dome
• Family & employee owned
• Financing and leasing available
• Customized delivery programs available
HOW DO I FIND MY
SALES REP?
Visit our website, www.propanetank.com to
view a list of our reps. Once on our site you'll
be able to choose the Commercial options and
from there you'll be taken to a list of US states
where you can choose your location and view
the contact information for your local sales rep.
If you don't see your sales rep. please give us
a call at 800-345-2495.
Our manufacturing locations are strategically
located to help serve your tank needs.
OHIO LOCATION
721 Graham Drive
Fremont, OH 43420
- - --- .
UTAH LOCATION
5601 Axel Park Rd.
West Jordan, UT 84081
801-280-1133
HOME OFFICE
2914 U.S. 61
Cleveland, M5 38732
800-345-2495
Consult our dimension and specification chart below to find the tank that best fits your needs.
Visit our website at www.propanetank.com for more information.
(]VFRAI I I FNrTH
OVERALL
HEIGHT
.0 LEG SPACING 111P
LEG
-d WIDTH �.
�t/ %
LEG WIDTH
APPROXIMATE ABOVEGROUND/UNDEGROUND (AG/UG) VESSEL DIMENSIONS AND SPECIFICATIONS
WATER
CAPACITY
DIAMETER
(OD)
HEAD
TYPE
OVERALL
LENGTH
OVERALL
HEIGHT
LEG*
WIDTH
LEG**
SPACING
WEIGHT
(Ibs.)
**QUANTITY
FULLLOAd
PERSTACK
120 wg.
2411
Ellip.
5P-811
3
1-1 1/2
or 3'-11"
260
108 196
16 1 12
*250 wg.
30"
Hemi.
7'-10"
3'-8"
1'-5"
4'-11"
480
54
9
*320 wg.
30"
Hemi.
9'-7"
3'-8"
1'-5"
5'
620
45
9
500 vvg.
37 1/2"
Hemi.
10,
4'-2"
1'-8"
5'
950
37 30
8 6
1000 wg.
41"
Hemi.
1 16'
1 4'-5"
1 1'-8"
1 10'-11,
1 1,800
17 15
6 5
1450 wg.
46 1/2"
Ellip.
17'-4"
4'-11"
1'-9"
11'-7"
2,650
1 12
1 4
1990 w .
46 1 2"
Ellip.
23'-11"
4'-11"
1'-9"
16'
3,520
1 8
1 4
Dimensions and specifications shown are approximate. Individual vessels may vary
Leg spacing +1- 2". Leg widths and spacing may vary based on mfg. location. Check with your salesperson for details. 120, 250, 320 wg. standard
tanks - no holes in legs (one center hole on request). 500 and 1000 wg. standard tanks - 2 holes 16" on center. 1450 wg. and up as shown above.
.. Full load and stack quantities vary by shipping location. Check with your salesperson for details.
QUALITY STEEL
Because duality Steel Means Quality Tanks
i Thank Yom Ipf S4ppurhn9 USA Manufacturers i
HOME OFFICE
2914 U.S.61
Cleveland, MS 38732
800-345-2495
OHIO LOCATION
721 Graham Drive
Fremont, OH 43420
419-334-2664
UTAH LOCATION
5601 Axel Park Rd.
West Jordan, UT 84081
801-280-1133
Quality Steel 612017 S2
STORAGE TANK IS ADEQUATELY
ANCHORED TO PREVENT FLOATATION,
COLLAPSE OR LATERAL MOVEMENT
DURING THE BASE FLOOD EVENT.
ALL WORK SHALL BE IN ACCORDANCE WITH
NFPA 54-58, NATIONAL FUEL GAS CODE
AND FLORIDA FUEL GAS CODE 2020 do
FLORIDA BUILDING CODE 2020.
TANKS INSTALLED IN TRAFFIC AREAS
SHALL BE PROTECTED WITH GALV. STEEL
SCHED. 80 PIPE BOLLARDS (eO) 6' LONG
X 3' BURY DEPTH WITH CAP ® 3' O.C.
PROPANE TANK BUOYANCY
MAX BUOYANCY = pv'g`Vtx*
= 1.94 slug/ft' 32.2 ft/s` " 66.84 ft'
= 4176 LBS
NET BUOYANCY = MAX BUOYANCY — WEIGHT OF EMPTY TANK
= 4176 LBS — 871 LBS
= 3305 LBS
FORCE ON J" CABLE = 3305 / 2 = 1653 LBS
TENSILE STRENGTH OF 4" CABLE = 9800 LBS / 5 = 1960 LB
FORCE ON AUGER ANCHOR = 1653 / 2 = 827 LBS
MIN. PULL—OUT RESISTANCE OF AUGER ANCHOR = 1360 LBS
LP TANK
1" 7A9 GALV.
AIRCRAFT CABLE
2 TOTAL (IN POLY.
SLEEVE)
AUGER ANCHOR, 36'
LONG W/ 6.0 HELIX
4 TOTAL
SIDE ELEVATION
SCALE 1/4" = P—O"
GRASS
17LB. ANODE
I
LP TANK EXCAVATION SIZE
`, 121 x 0 x 4.5'D
7xl9 GALV.
"'a
�°
AIRCRAFT CABLE
STRAPPING BOLT
AUGER ANCHOR, 36"
Dlgltally elgned by E4c Svuboda
LONG W/ 6"0 HELIX
AdoDate2ozi 52 OSoo�
be Aversion:
2020.013.2007.200I4
FRONT ELEVATION
SCALE 1/4" - 1'-0"
Felrellgas
3232 SE Dixie Hwy.
Stuart, FL 34997
Fort Pierce Engineering, Inc.
Dependable Mechanical, Elebukti
& Pitenbing Design
C.A. No. 28173
315 South 7th Street
Port Pierre, FL. 34950
Phone: 772 672-4636
Fbx:772 672-4637
.eea.a,,,. Iaaoas,"
�F� i•;
Q1161JR'5l odffv P '
ISSUE ;
APPROVED: EJS
DRAWING NUMBER
T—l_
LP500
NFPA 58-2017 and 2020 Editions
Liquefied Petroleum Gas Code
TIA Log No.: 1.480
Reference: Table 16.1(n)
Comment Closing Date: June 17, 2020
Submitter: Tom Dunn, Iowa Propane Gas Association
www nfpa ore/58
1. Revise Table 16.l (n) to read as follows (highlighted to show corrections):
,/n in. SDR 3/4 In. SDR 1 In. SDR 11/4 in, SUK 11/2 in. SDR it 2 In. SDR 11
9,33 _11 _. ,. il-,. (1.554) (1.943)
30
2111 40
049M
7741
134"
20300
36400
40
1840
3670
6630
11480
17300
31200
50
1630
3260
5870
10180
15400
27600
60
1470
2950
5320
9220
13900
25000
70
1360,.—
2710
4900_.__
_ 8480. _
12800_
23000
�21400
80
1260
._
2530
_
4560
7890
11900
90
11,80
2370
4270
7400
11200
20100
100
1120
2240
4040
6990
10600
19000
125
990
3580
6200
9360
16800
150
897$9Q
3240
5620
8480
15200
175
826
2980
5170
7800
14000
200
778
ft49
2780
4810
7260
13000
225
721
2600
4510
6810
12200
250
681
2460
4260
6430
11600
27S
646
2340
4050 ,.
6110
..._._..., .,.............
11000
.,, .,.. . _._.�
_.__....
300
........... . .... ....... ...
617
_._...
.., .......
2230
......_......
3860
5830
1.0470
350
567
2050
3550
5360
9640
400
528
&MM
1910
3300
4990
8970
450
495
�:Z
1
3100
......,.
4650
........__ ..,_........
8410
.._., .,..,.,.,
._.,.._._ .,.,
500
.. ..............
468
..._.
_._
9.4
2930
4420
7950
600
424
F
2650
4010
7200
700
390
�
(A
2440
3690
6620
800
363
2270
3430
6160
900
340
2130
3220
5780
1000
322
54
2010
3040
5460
1500
258
#'M($Qs244Q
4390
2000
221.
Sim
33$D
083(i
3750
Application O
Ideal for use as a first stage regulator on any domestic size ASME or
DOT container in propane gas installations requiring up to 1,500,000 LISTED
BTU's per hour. The regulator is factory set to reduce container
pressure to an intermediate pressure of approximately 10 PSIG.
Feat -tires
• Compact design can be connected to a service valve using either
a POL adapter or a RegO product pigtail.
• Large threaded W F.NPT bonnet vent can eas€ly be piped -away
underground installations without the need of glue kits or extra
adapters.
• Nan Adjustable
• Large flow orifice resists freeze ups due to water concentration in
LPG vapor.
• Design provides for good flow regulation at both high and low
container pressures.
• Built in relief valve and travel slop comply with NFPA 58 over
pressure requirements.
• Incorporates VV F.NPT downstream pressure tap for an easy
inline check of the regulator's delivery pressure.
• Molded diaphragm provides an o-ring type seal between the
body and bonnet.
• Body and bonnet are assembled in the USA using the unique,
patented RegUlok seal system.
• Fully painted in brilliant red for complete corrosion protection.
• Mounting bracket available as an accessory: part number 2302-31.
Materials
Body............................................................................................Zinc
Bonnet.........................................................................................Zinc
Spring....................................................................................... Stee!
Seat Disc................................................................. Resilient Rubber
Diaphragm...........................Integrated Fabric and Synthetic Rubber
25 10
w
e
Cti
Information
LV3403TR
arum. xee.000 soo,mo f.xsgooa »owe 1 �5a.tto
FLOW PROPANE
LV3403TR Over Outlet
LV3403TRV9 /" F.NPT %z" F.NPT 7132" 10 PSIG 1 1,500,000
_1 9:00
` Maximum flow based on inlet pressure 23 PSIG higher than the regulator setting and delivery pressure 20% lower than the regulator setting and delivery pressure 20% lower than the setting.
A14 EV&O0 100 RegO or Eton, NG 27244 USA www.regoproducts com +1 (336) 449-1707
Application
Designed to reduce first stage pressure of 5 to 20 PSIG down to
burner pressure, normally 11" w.c. Ideal for medium commercial
installations, vapor meter installations and normal domestic loads.
Feahires
• 90 degree right angle inlet to outer connection for meter or
standard installations.
• Large vent helps to prevent blockage and has %" F. NPT for vent
piping.
• With 15 PSIG inlet pressure, regulator is designed to not pass
more than 2 PSIG with the seat disc removed.
• Replaceable valve orifice and valve seat.
• Straight line valve closure reduces wear on seat disc
• Unique bonnet vent profile minimizes vent freeze over when
properly installed.
• Large molded diaphragm is extra sensitive to pressure changes.
• Built in pressure tap has plugged ''/a" F. NPT outlet. Plug can be
removed with a 3t16" hex allen wrench.
• Select Brown Finish
It€glit Angle Resign
Can mount directly to vapor meter. It is also suitable for mounting
directly to the house piping. It will retrofit into existing installations that
are currently using a 90 degree, right angle regulator.
Materials
Body........................................................................... Die Cast Zinc
Bonnet........................................................................ Die Cast Zinc
NozzleOrifice......................................................................... Brass
Spring...................................................................................... Steel
Valve Seat Disc ..................................................... Resilient Rubber
Diaphragm ......................... Integrated Fabric and Synthetic Rubber
X
p1tRilpp_
a�� c
�9
Information
uL
CFWhr.
BTUihr.
t
w/ Mounting Bracket
B 11 Inlat-
50 100 150 200 250 300 350 400 450
250.00O 500.000 750,000 1.000.000 1
LV44031366RA 11" W.C. at 10
LV4403866RA- 3/" F. NPT 3/4" F. NPT 3/16" PSIG Inlet 9" to 13" w.c. Over Inlet
1,000,000
Maximum flow is based on 10 PSIG inlet and 9" w,c. delivery pressure_
'* Mounting Bracket Included, 6
100 Rego Dr. Elan, NO 27244 USA www.regoproducls.com +1 (336) 449-7707 r�EG93 am