Loading...
HomeMy WebLinkAboutProject Information Job: 3405 Industrial 31st Stre.., +f+ wrightsoft Project Summary Date: June 30,2021 Entire House By: Anthony Ave rsa Sea CoastAir Conditioning 3108 Industrial 31st Streel,Fort Plerce,FL 34946 Phow 772 4 66-2400 Efftag:dispatch@seaooastalr.com i • • • I For. Tomaria LLC 3405 Industrial 31 st Street,Fort Pierce,FL 34946 Notes: 3405 Industrial 31st Street,Fort Pierce,34946 ® - lin:1nf6rrnafi6n Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside clb 95 OF Inside db 70 OF Inside db. 75 OF Design TD 28 OF Design TD 20 OF Daily range M Relative humidity 50 % Moisture difference 53 grAb Heating Summary Sensible Cooling Equipment load Sizing Structure 3555 Btuh Structure 4411 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 11 Btuh Blower 1707 Btuh Piping 0 Btuh Equipment load 3567 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 6118 Btuh Method Simplified latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2378 Btuh Ducts. 0 Btuh Central vent(0 cfm) 0 Btuh Healing coolingg (none) Area(ft2) 18D 180 Equipment latent load 2378 Btuh Volume(ft') 1440 1440 Air changes/hour 0.61 0.32 Equipment Total Load(Sen+Lat) 8496 Btuh Equiv.AVF(cfm) 15 8 Req.total capacity at 0.70 SHR 0.7 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Daikin Trade n/a Trade Daikin Model n/a Cond RK09AXVJU AHRI ref n/a Coil FTK09AXJU AHRI ref 205782844 Efficiency n/a Efficiency 12.5 EER,19 SEER Heating Input 0 Btuh Sensible cooling 6230 Btuh Heating output 0 Btuh Latent cooling 2670 Btuh Temperature rise 0 OF Total cooling $900 Btuh Actual air flow 201 cfm Actual air flow 201 cfm Air flow factor 0.056 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.72 I BoWlearrc values have been manually overridden Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrtghtsoft 2021•Jut30 07:33:03 ,,.._..,...,....�.. _, Right-Suite®Uriversal201919.0.13 RSU28644 Pago 1 ACCA C:1UserstaversaVesldop%GdwoodBlock.rup Calc=MA Frord Door faces:N I Manual S Compliance Report Job: 3405 Industrial 31stStre... wrigh- tsoft° p Date: June 30,2021 Entire House By: Anthony Aversa Sea Coast Air Conditioning 3108 Industrial 3114 Street,Fort Pierce,FL 34946 Phone:772 466-2400 PCB:dlspatch@seacoastairmm • ec' t Information For: Tomaria LLC 3405 Industrial 31st Street,Fort Pierce,FL 34946 --�Qooling Equip Design Conditions. Outdoor design DB: 95.0°F Sensible gain: 6118 Btuh Entering coil DB: 82.9°F Outdoor design WB: 78.0°F Latent gain: 2378 Btuh Entering coil WB: 65.2°F Indoor design DB, 75.0°F Total gain: 8496 Btuh indoor RH: 50% Estimated airflow: 201 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitAC Manufacturer. Daikin Model: RK09AXVJU+FTK09AXJU Actual airflow: 201 cfm Sensible capacity: 6230 Btuh 102%of load Latent capacity: 2670 Btuh 112%of load Total capacity: 8900 Btuh 105%of load SHR: 70% Heating • • Design Conditions Outdoor.design DB: 42.0°F Heat loss: 3567 ' Btuh. Entering coil DB: 0°F- Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Manufacturer Model: Actual airflow: 201 cfm Output capacity: 0 Btuh 0%of load Temp.rise: 0 °F Meets all requirements ofACCA Manual S. wrightsoftF, 2021-An-30 07:33:03 ,., Flight-Sate®Uriversal 2019 19.0.13 RSU28644 Page 1 X0% C:WserslaversaUesktopllodcwoodBlodc.np Calc=MJ8 Front Door faces:N