Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MW-66 Builder Name: Street: 2640 CONIFER DR Permit Office: City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41816.1 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, Exterior R=4.1 1612.30 ft2 b. Frame - Wood, Adjacent R=11.0 203.78 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Types (1810.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=40.0 1810.00 ft2 6. Conditioned floor area above grade (W) 1810 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(214.3 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Main R ft2 6 486 a. U-Factor: Dbl, U=0.62 214.34 ft2 SHGC: SHGC=0.26 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 34.6 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 5.087 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.260 a. Electric Strip Heat 24.8 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1810.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1810.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.118 Total Proposed Modified Loads: 52.24 PASS Total Baseline Loads: 57.41 I hereby certify that the plans and specifications covered by Review of the plans and �4TKE this calculation are in compliance with the Florida Energy specifications covered by this ' _ O*, Code. calculation indicates compliance with the Florida Energy Code. F. rn„�,�� ;,; . ` „ O ` PREPARED BY: DATE: 03/25/2021 Before construction is completed this building will be inspected for compliance with Section 553.908 C * ° I hereby certify that this building, as designed, is in compliance the Florida Energy Code. Florida Statutes. ✓,� �� CAD with W . OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). C'Dv REVIEED FOR FILE'3 U1 CODE COMPLIANCE • Sl`a LUCIE COUNTY 3/25/2021 3:12 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Co �nt,S� are Page 1 of 4 OnDnn oAnA_InIn INPI IT SI IMMORY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-66 User 1 Detached New (From Plans) Bedrooms: 3 Conditioned Area: 1810 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 2640 CONIFER DR County: St. Lucie City, State, Zip: FORT PIERCE, FL, 34951 CLIMATE / v Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 1810 17376 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1810 17376 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 192.7 ft 1810 ft2 _e 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Concrete 2024 ft2 0 ft2 Medium N 0.4 N 0.9 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1810 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 40 Blown 1810 ft2 0.1 Wood 3/25/2021 3:12 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 none oAnc on,3n IIUDI IT CI IMMOI?V rI4F[_K1 IAT RFPnRT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Ornt Space TO Wall Type _ 1 N Exterior Concrete Block - Ext Insul Main 4.1 19 4 9 4 180.4 ft2 0 0 0.3 0 _ 2 E Exterior Concrete Block - Ext Insul Main 4.1 56 2 9 4 524.2 ft2 0 0 0.3 0 _ 3 S Exterior Concrete Block - Ext Insul Main 4.1 41 5 9 4 386.6 ftz 0 0 0.3 0 _ 4 W Exterior Concrete Block - Ext Insul Main 4.1 55 10 9 4 521.1 ft2 0 0 0.3 0 5 - Garage Frame - Wood Main 11 21 10 9 4 203.8 ft2 0 0.25 0.3 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 26.0 ft2 7 ft 0 in 1 ft 0 in None None 2 N 1 Metal Double (Clear) Yes 0.62 0.26 N 24.0 ft2 7 ft 0 in 1 ft 0 in None None 3 e 2 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft2 1 ft 0 in 1 ft 0 in None None 4 s 3 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft2 1 ft 0 in 1 ft 0 in None None 5 s 3 Metal Double (Clear) Yes 0.62 0.26 N 26.0 ft2 1 ft 0 in 1 ft 0 in None None 6 s 3 Metal Double (Clear) Yes 0.62 0.26 N 64.0 ft2 1.0 ft 0 in 1 ft 0 in None None 7 w 4 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft2 1 ft 0 in 1 ft 0 in None None 8 w 4 Metal Double (Clear) Yes 0.62 0.26 N 7.0 ft2 1 ft 0 in 1 ft 0 in None None 9 W 4 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft2 1 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 526 ft2 526 ft2 64 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000427 2027.2 111.22 208.8 .1359 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 24.82 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 34.6 kBtu/hr cfm 0.7 1 sys#1 3/25/2021 3:12 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 ter% Mery nnnn INDI IT CI IMMADV ['NF['KI 1ST RFPnRT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 486 ft2 Attic 222 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling[[ ]] Jan [[ ]] Feb Heatin[X] Jan [X] Feb [[ ]] Mar [X] Mar [ ] Apr [ ] pr [ ] May [X] Jun [X] Jul [ ] May ] Jun [ ]Jul [X] AugX] ]AuE Se ]Sep [ ] [ ]Oct Oct [ ] [X] Nov Nov Dec Dec Venting [[ ]] Jan [[ 11 Feb [[�X]] Mar [X] Apr [ ] May ] Jun [ ] Jul E E ] Aug l Se [Xl Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66. 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 3/25/2021 3:12 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 91 The lower the EnergyPerformance Index, the more efficient the home. 2640 CONIFER DR, FORT PIERCE, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, Exterior R=4.1 1612.30 ft2 b. Frame - Wood, Adjacent R=11.0 203.78 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=40.0 1810.00 ft2 6. Conditioned floor area (W) 1810 b. N/A R= ft2 c. N/A R= ft2 7. Windows- Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor: Dbl, U=0.62 214.34 ft2 a. Sup: Attic, Ret: Attic, AH: Main 6 486 SHGC: SHGC=0.26 b. U-Factor: N/A ft2 SHGC: 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 34.6 SEER:16.00 SHGC: d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 24.8 COP:1.00 Area Weighted Average Overhang Depth: 5.087 ft. Area Weighted Average SHGC: 0.260 8. Skylights Description Area 15. Hot water systems Cap: 50 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF: 0.94 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1810.00 ft2 Credits (Performance method) Pstat b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied ith the Florida Energy Efficiency Code for Building Construction through the above ener y saving features which will be installed (or exceeded) in this home before final inspection. therwise, a new EPL Display Card will be completed based on installed Code compliant fe tures. Builder Signature: Address of New Home: Date: 3 3 p a l City/FL Zip: Ff PRCE . 34951 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. *"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/25/2021 3:12 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Jurisdiction: Permit #: 4-66114o 11Dn � Builder: Community: Lot: NA Address: 2640 CONIFER DR City: FORT PIERCE State: FL Zip: 34951. /4k Leakage Tesest Ru Its Passing results must meet either the Performance Prescnpfrve or ERl Method b eA �1y-.4 ��i% m i $mac;, 'w�.Fi FOB aA �vA',•., z �.'s PRESCRIP7tYE METHpb TFie b iildtng or:dwell ng unit shalt be tested aid venfletl as having an air leakagearate of not..exceetling 7 airy ; changes per'hour at a pressure of Q 2 inch w g (50 Pascals} jn to Zones 1 and 2 , �. u�Q E�ERFORMANCEyo1r Rf METHOO The�bu�ldmg or dwelling unit shall�be #estt venf1ed:as having'an air le kage rate,of not exceeding,:; the selected ACH(50) value; as�sho4vn on Forth R405-2020 (Peiforrnance} or R406-2C120 (ERI), section labeied�`as �nfiltratiori, sub=section ACH5Q P � ;�;y� ���� ���a ACF! 50 e "fied on�l=oma R405-2020=Ene Cate {Performance) or R406 2020 {ERfj � N 7.000 � � � x 60 = 17376 — Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans FIPASS • Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g); or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if Installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. TeStln Imp V SS R ; . r o F Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 3/25/2021 3:13:01 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 ® Load Short Form Job: �- wrightsoft Date: Mar23,2021 Entire House By. For. MW-66 Project Information TBD, FORT PIERCE, FL 34951 Design Information Htg Cig Infiltration Outside db (OF) 43 91 Method Simplified Inside db (OF) 70 72 Construction quality Average Design TD (OF) 27 19 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (grAb) 0 65 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond ML14XClS036-230C** AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 204289057 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating input 7.3 kW Sensible cooling 24220 Btuh Heating output 24817 Btuh Latent cooling 10380 Btuh Temperature rise 20 OF Total cooling 34600 Btuh Actual airflow 1153 cfm Actual airflow 1153 cfrn Air flow factor 0.048 cfm/Btuh Air flow factor 0.052 cf n/Bbih Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.69 ROOM NAME Area (flZ) Htg load (Btuh) Cig load (Btuh) Htg AVF (clm) CIgAVF (clml) MASTER SUITE 312 4847 3652 232 189 HER W IC 60 927 524 44 27 MASTER BATH 169 1781 2224 85 ' 115 BED 2 205 2922 3306 140 171 UTILITY 73 1099 994 53 52 BATH 2 79 64 197 3 10 FOYER 91 1035 816 50 42 DINING 131 3528 2634 169 137 WCHEN 153 1598 2104 76 109 BEDROOM 3 181 3335 2322 160 120 360 2966 3477 142 180 GREAT RM Calculations approved byACCAto meetall requirements of Manual J 8th Ed. wrightsoft- 2021-Mar-2515:09:39 �1 .Mff.---,�,.., RightSute®Uriversal2021 21.0.05 RSU29964 Page 1 +CA...ersOxWseADoomertslWdghtsoftWAC\MW-66jW Calc=W8 FrortDoorfaces: N Entire House 1815 24101 22250 1153 1153 Other equip loads 0 0 Equip. @ 0.95 RSM 21249 Latent cooling 10068 TAI Q 1104= 13A1n1 Q1Q17 Calculations approved byACCAto meet all requirements of Manual J 8th. Ed. -�- wrightsoft® RigkSufe®Uriversa1202121.0.O5RSU29964 +�► ....W WserlDoamenhAWdgksoftWACVM-66.np Calc=MJ6 FrortDoorfeces: N 2021-Mar-2515:09:39 Page 2 - wrightsoft® Project Summary Entire House Project Information For: MW-66 TBD, FORT PIERCE, FL34951 Notes: Design Information Weather: Vero Beach Municipal AP, FL, US Winter Design Conditions Outside db 43 OF Inside db 70 OF Design TD 27 OF Heating Summary Structure 20922 Btuh Ducts 3179 - Btuh Central vent (0 dm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24101 Btuh infiltration Method Simplified Construction quality Average Fireplaces 0 Heatingg Coolingg Area (fF) 1815 1815 Volume (f !) 17327 17327 Air changesAiour 0.38 0.20 Equiv AVF (cfm) 110 58 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating Input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 7.3 kW 24817 Btuh 1150 OF 3 ofm 0.048 dim/Btuh 0 in H2O Job: Date: Mar 23, 2021 By. Summer Design Conditions Outside db 91 OF Inside db 72 OF Design TD 19 OF Daily range L Relative humidity 50 % Moisture difference 65 grAb Sensible Cooling Equipment Load Sizing Structure 18844 Btuh Duds - 3406 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swin multipplier 0.95 EquipmenIsensibleload 21249 Btuh Latent Cooling Equipment Load Sizing Structure 8554 Btuh Ducts 1514 Btuh Central vent (0 ctm) 0 Btuh (none) Equipment latent load 10068 Btuh Equipment Total Load (Sen+Lat) 31317 Btuh Req. total capacity at 0.70 SHR 2.5 ton Cooling. Equipment Summary Make Lennox Trade LENNOX Cond ML14XC1S036-230C** Coil CBA27UHE-036-230*++TDR AHRI ref 204289057 Efficiency 13.0 EER,16 SEER Sensible cooling 24220 Btuh Latent000ling 10380 Btuh Total cooling 34600 Btuh Actual airflow 1153 cfrn Airflow factor 0.052 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.69 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -*- wrightsoft® 2021-Mar-2515:0939 ^•� Mw•w •,�. mm Rig1t-SUte®Uriversal2021 21.0.05 RSU29964 Page 1 ACCA .srsVVVUserlDoamerts\WdgtisoftHVACMWS6xW Calc=MJ8 FrortDoorfaws: N MASTER SUITE PATIO 10x10 x8 18'x18' 189 CFM RAG. W! 12'0 FLEX WIC MAS R 50 FM BEDROOM 2 v w Us 50 CFM EXHAUST 0 x 10 x 115GF 12°x12' 10x10X8 RAG. 171 CFM r° FL9. — D El 8 x8 x 18'x18' B T10H°2 1 WO TWO BAY GARAGE fro 15 I CFM / II GREAT ROOM 3-TON 10x10x8 - — 1ox1ox7137 (KITCOHEN CFMDINING 8x8x5 42 CFM FOYER BEDROOM 3 PORCH DO NOT SCALE PLANS T.STAT SHALL BE WITHIN 3 FEET HORIZONTALLY OF MAIN RETURN V W In 14- Oi� n in J LL. �LJ L W LL W O I Z af `d O _ U CL 0 Of � �/ N