HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: RODOLFO VEGA
BuilderName:
Street: 1950 BRCOKSMITH
RD.
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
PermitNumber:
Owner: RODOLFO VEGA
Jurisdiction: ST. LUCIE COUNTY
DesignLocation: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall Types(7597.3 sqft.)
Insulation; Area
2. Single family or multiple family
Detached
a. Concrete Block- Int Insul, Exterior
R=4.1 7177.30 ft2
b. Frame - Wood, Adjacent
R=11.0 420.00 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
7
d. N/A
R= ft2
5. Is this a worst case?
No
11. Ceiling Types (6509.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 6509.00 ftZ
6. Conditioned floorarea above grade (ft2)
6509
b. N/A
R= ft2
Conditionedfloor area below grade (ft2)
0
c. N/A
R= ft2
7. Windows(922.4 sqft.) Description
Area
12. Ducts
2 additional duct system(s)
R ft2
6 125
a. U-Factor: Sgl, U=0.32
711.04 ft2
b. Sup: Attic, Ret: Attic, AH: Garage
6 325
SHGC: SHGC=0.22
c. Sup: Attic, Ret: Attic, AH: A/C 3
(seedetails
b. U-Factor: Sgl, U=0.29
97.68 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.23
a. Central Unit
18.8 SEER:16.00
c. U-Factor: Sgl, U=0.35
96.00 ft2
b. Central Unit
41.0 SEER:16.00
SHGC: SHGC=0.20
2 additional cooling systems
(seedetails)
Area Weighted Average Overhang Depth:
5.545 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.219
a. Electric Strip Heat
17.0 COP:1.00
8. Skylights
Area
b. Electric Strip Heat
34.0 COP:1.00
2 additional heating systems
(seedetails)
c. U-Factor:(AVG) N/A
ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (6507.0 sqft.)
Insulation Area
EF:0.950
a. Slab -On -Grade Edge Insulation
R=0.0 6507.00 ft2
b. Conservation features
b. N/A
R= ft2.
None
c. N/A
R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.142
Total Proposed Modified Loads: 194.33
PASS
Total Baseline Loads: 212.26 ,
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with
the Florida Energy
specifications covered by this
��k1E;SxgT�
p
Code
calculation indicates compliance
with the Florida Energy Code.
PREPARED BYQAC]��
Before construction is completed
DATE: -22-2 3211
this building will be inspected for
T , --
compliance with Section 553.908:'
hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.�'OD�.
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: ds^cZ
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
COO
4/22/2021 7:36 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Softwaree Page 1 of 12
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
RODOLFO VEGA
Bedrooms:
7
Address Type:
StreetAddress
Building Type:
User
ConditionedArea:
6509
Lot#
OwnerName:
RODOLFO VEGA
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
BuilderName:
RotateAngle:
0
Street:
1950 BRCOKSMITH RD
Permit Office:
ST. LUCIE COUNTY
CrossVentilation:
No
County:
St. Lucie
Jurisdiction:
ST. LUCIE COUNTY
Whole House Fan:
No
City, State,
Zip:
FT. PIERCE,
FamilyType:
Detached
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design
DailyTemp
V DesignLocation
TMY Site
97.5 %
2.5 %
Winter
Summer
DegreeDays
Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
UNIT#1
928
9280
2
UNIT #2
2812
32320
3
UNIT #3
1374
16470
4
UNIT #4
1395
16740
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
GUEST KIT/LIVING
448
4480 No
0
1
Yes
Yes
Yes
2
GUEST BEDROOM
206
2060 No
0
1
.1
Yes
Yes
Yes
3
GUEST BATH
45
450 No
0
1
No
Yes
Yes
4
GUEST BEDROOM
208
2080 No
0
1
1
Yes
Yes
Yes
5
A/C 1
21
210 No
0
1
Yes
Yes
Yes
6
THEATER GAME R
523
5230 No
0
1
Yes
Yes
Yes
7
BATH 2
50
500 No
0
1
Yes
Yes
Yes
8
BONUS ROOM
85
850 No
0
1
Yes
Yes
Yes
9
BATH
42
420 No
0
1
No
Yes
Yes
10
FAMILY ROOM
288
2880 No
0
1
Yes
Yes
Yes
11
GALLERY
120
1200 No
0
1
Yes
Yes
Yes
12
BREAKFAST AREA
269
2690 No
0
1
Yes
Yes
Yes
13
PANTRY
60
720 No
0
1
No
Yes
Yes
14
KITCHEN
306
3672 Yes
0
1
No
Yes
Yes
15
OFFICE
132
1584 No
0
1
Yes
Yes
Yes
16
DINING
228
2736 No
0
1
Yes
Yes
Yes
17
GALLERY.
44
528 No
0
1
No
Yes
Yes
18
FOYER
138
1932 No
0
1
Yes
Yes
Yes
19
LIVING AREA
527
7378 No
0
1
Yes
Yes
Yes
4/22/2021 7:36 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 12
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name
Area Volume
Kitchen Occupants
Bedrooms
InfilID
Finished
Cooled
Heated
20
BEDROOM 2
196 2352
No
2
1
1
Yes
Yes
Yes
21
CLOSET 5
56 672
No
0
1
No
Yes
Yes
22
BEDROOM 5
202 2424
No
2
1
1
No
Yes
Yes
23
BATH 5
65 780
No
0
1
Yes
Yes
Yes
24
BEDROOM 4
198 2376
No
2
1
1
Yes
Yes
Yes
25
CLOSET 3
28 336
No
0
1
No
Yes
Yes
26
CLOSET4
40 480
No
0
1
Yes
Yes
Yes
27
UTIITY
87 1044
No
0
1
Yes
Yes
Yes
28
HALLWAY
83 996
No
0
1
No
Yes
Yes
29
A/C 3
9 90
No
0
1
No
Yes
Yes
30
BEDROOM 3
251 3012
No
2
1
1
Yes
Yes
Yes
31
BATH 4
109 1308
No
0
1
Yes
Yes
Yes
32
BATH 3
50 600
No
0
1
No
Yes
Yes
33
MASTER BEDROO
465 5580
No
2
1
1
Yes
Yes
Yes
34
M CLOSET
54 648
No
0
1
Yes
Yes
Yes
35
TOILET
42 504
No
0
1
Yes
Yes
Yes
36
M BATH
241 2892
No
0
1
Yes
Yes
Yes
37
M BATH GALLERY
80 960
No
0
1
No
Yes
Yes
38
WIC 2
152 1824
No
0
1
Yes
Yes
Yes
39
WIC 1
154 1848
No
0
1
No
Yes
Yes
40
M GALLERY
53 636
No
0
1
Yes
Yes
Yes
41
EXERCISE ROOM
154 1848
No
0
1
No
Yes
Yes
FLOORS
# FloorType
Space
Perimeter PerimeterR-Value
Area
JoistR-Value
Tile
Wood
Carpet
1Slab-On-Grade Edge Insulation
GUEST KIT/LIVIN
60ft
0
448ft2
----
0
1
0
2 Slab -On -Grade Edge Insulation
GUEST BEDROO
19 ft
0
206 ft2
----
0
1
0
3Slab-On-Grade Edge Insulation
GUEST BATH
lift
0
45 ft2
----
0
1
0
4Slab-On-Grade Edge Insulation
GUEST BEDROO
13ft
0
208ft2
----
0
1
0
5Slab-On-Grade Edge Insulation
A/C 1
3 ft
0
21 ft2
----
0
1
0
6 Slab -On -Grade Edge Insulation
THEATER GAME
36 ft
0
522.5 ft2
----
0
1
0
7 Slab -On -Grade Edge Insulation
BATH 2
15 ft
0
50 ft2
----
0
1
0
8Slab-On-Grade Edge Insulation
BONUS ROOM
11 ft
0
85ft2
----
0
1
0
9 Slab -On -Grade Edge Insulation
BATH
lift
0
42 ft2
----
0
1
0
10SIab-On-Grade Edge Insulation
FAMILY ROOM
11.8 ft
0
288 ft2
----
0
1
0
11SIab-On-Grade Edge Insulation
GALLERY
6 ft
0
120 ft2
----
0
1
0
4/22/2021 7:36 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 12
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# FloorType
Space
Perimeter PerimeterR-Value
Area JoistR-Value
Tile
Wood
Carpet
12SIab-On-Grade Edge Insulation
BREAKFAST AR
20.8 ft
0
269 ft2 ----
0
1
0
13SIab-On-Grade Edge Insulation
PANTRY
1 ft
0
60ft2 ----
0
1
0
14SIab-On-Grade Edge Insulation
KITCHEN
1 ft
0
306ft2 ----
0
1
0
15SIab-On-Grade Edge Insulation
OFFICE
12 ft
0
132 ft2 ----
0
1
0
16SIab-On-Grade Edge Insulation
DINING
34ft
0
227.5ft2 ----
0
1
0
17SIab-On-Grade Edge Insulation
GALLERY.
1 ft
0
44 ft2 ----
0
1
0
18SIab-On-Grade Edge Insulation
FOYER
9 ft
0
138 ft2 ____
0
1
0
19SIab-On-Grade Edge Insulation
LIVING AREA
19 ft
0
527 ft2 ----
0
1
0
20SIab-On-Grade Edge Insulation
BEDROOM 2
22 ft
0
195.5 ft2 ----
0
1
0
21SIab-On-Grade Edge Insulation
CLOSET 5
1 ft
0
56 ft2 ----
0
1
0
22SIab-On-Grade Edge Insulation
BEDROOM
1 ft
0
202ft2 ----
0
1
0
23SIab-On-Grade Edge Insulation
BATH 5
10 ft
0
65 ft2 ----
0
1
0
24SIab-On-Grade Edge Insulation
BEDROOM 4
14 ft
0
198 ft2 ----
0
1
0
25SIab-On-Grade Edge Insulation
CLOSET3
, lit
0
28ft2 ----
0
1
0
26SIab-On-Grade Edge Insulation
CLOSET4
13ft
0
40ft2 ----
0
1
0
27SIab-On-Grade Edge Insulation
UTIITY
8ft
0
87ft2 ----
0
1
0
28SIab-On-Grade Edge Insulation
HALLWAY
1 ft
0
83 ft2 ----
0
1
0
29SIab-On-Grade Edge Insulation
A/C 3
1 ft
0
9 ft2 ----
0
1
0
30SIab-On-Grade Edge Insulation
BEDROOM 3
28 ft
0
251 ft2 ----
0
1
0
31SIab-On-Grade Edge Insulation
BATH 4
8ft
0
109 ft2 ----
0
1
0
32SIab-On-Grade Edge Insulation
BATH 3
1 ft
0
50 ft2 ----
0
1
0
33SIab-On-Grade Edge Insulation
MASTER BEDRO
60.3ft
0
465ft2 ----
0
1
0
34SIab-On-Grade Edge Insulation
MCLOSET
3.8ft
0
54ft2 ----
0
1
0
35SIab-On-Grade Edge Insulation
TOILET
7 ft
0
42 ft2 ----
0
1
0
36SIab-On-Grade Edge Insulation
M BATH
48ft
0
241 ft2 ----
0
1
0
37SIab-On-Grade Edge Insulation
M BATH GALLER
1 ft
0
80 ft2 ----
0
1
0
38SIab-On-Grade Edge Insulation
WIC 2
9ft
0
152 ft2 _---
0
1
0
39SIab-On-Grade Edge Insulation
WIC 1
1 ft
0
154ft2 ----
0
1
0
40SIab-On-Grade Edge Insulation
M GALLERY
10.2 ft
0
53 ft2 ----
0
1
0
4/22/2021 7:36 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 12
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
FloorType
Space
Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood Carpet
41SIab-On-Grade Edge Insulation EXERCISE ROO 1 ft
0
153.5ft'
----
0 1 0
ROOF
/
V #
Type
Materials
Roof
Area
Gable Roof
Area Color
Rad
Barr
Solar SA Emitt
Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip
Metal
6861 ft2
0 ft2 Unfinishe
N
0.5 No 0.7
No 20 18.43
ATTIC
/
V #
Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented
0 6509 ft2
N N
4/22/2021 7:36 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 12
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic(Unvented)
GUEST KIT/LIVIN
0
Blown
448ft2
0.1
Wood
2
UnderAttic(Unvented)
GUEST BEDROO
0
Blown
206 ft2
0.1
Wood
3
UnderAttic(Unvented)
GUEST BATH
0
Blown
45 ft2
0.1
Wood
4
UnderAttic(Unvented)
GUEST BEDROO
0
Blown
208 ft2
0.1
Wood
5
UnderAttic(Unvented)
A/C 1
0
Blown
21 ft2
0.1
Wood
6
UnderAttic(Unvented)
THEATER GAME
0
Blown
523ft2
0.1
Wood
7
UnderAttic(Unvented)
BATH
0
Blown
50ft2
0.1
Wood
8
UnderAttic(Unvented)
BONUS ROOM
0
Blown
85 ft2
0.1
Wood
9
UnderAttic(Unvented)
BATH
0
Blown
42 ft2
0.1
Wood
10
UnderAttic(Unvented)
FAMILY ROOM
0
Blown
288 ft2
0.1
Wood
11
Under Attic(Unvented)
GALLERY
0
Blown
120ft2
0.1
Wood
12
UnderAttic(Unvented)
BREAKFAST AR
0
Blown
269 ft2
0.1
Wood
13
UnderAttic(Unvented)
PANTRY
0
Blown
60ft2
0.1
Wood
14
UnderAttic(Unvented)
KITCHEN
0
Blown
306ft2
0.1
Wood
15
Under Attic(Unvented)
OFFICE
0
Blown
132 ft2
0.1
Wood
16
UnderAttic(Unvented)
DINING
0
Blown
228ft2
0.1
Wood
17
UnderAttic(Unvented)
GALLERY.
0
Blown
44ft2
0.1
Wood
18
UnderAttic(Unvented)
FOYER
0
Blown
138ft2
0.1
Wood
19
UnderAttic(Unvented)
LIVING AREA
0
Blown
527 ft2
0.1
Wood
20
UnderAttic(Unvented)
BEDROOM 2
0
Blown
196 ft2
0.1
Wood
21
UnderAttic(Unvented)
CLOSET 5
0
Blown
56 ft2
0.1
Wood
22
UnderAttic(Unvented)
BEDROOM 5
0
Blown
202 ft2
0.1
Wood
23
UnderAttic(Unvented)
BATH
0
Blown
65ft2
0.1
Wood
24
UnderAttic(Unvented)
BEDROOM 4
0
Blown
198 ft2
0.1
Wood
25
UnderAttic(Unvented)
CLOSET 3
0
Blown
28 ft2
0.1
Wood
26
UnderAttic(Unvented)
CLOSET4
0
Blown
40ft2
0.1
Wood
27
UnderAttic(Unvented)
UTIITY
0
Blown
87ft2
0.1
Wood
28
UnderAttic(Unvented)
HALLWAY
0
Blown
83 ft2
0.1
Wood
29
UnderAttic(Unvented)
A/C 3
0
Blown
9 ft2
0.1
Wood
30
UnderAttic(Unvented)
BEDROOM 3
0
Blown
251 ft2
0.1
Wood
31
UnderAttic(Unvented)
BATH 4
0
Blown
109 ft2
0.1
Wood
32
UnderAttic(Unvented)
BATH 3
0
Blown
50ft2
0.1
Wood
33
UnderAttic(Unvented)
MASTER BEDRO
0
Blown
465ft2
0.1
Wood
34
Under Attic(Unvented)
MCLOSET
0
Blown
54ft2
0.1
Wood
35
UnderAttic(Unvented)
TOILET
0
Blown
42 ft2
0.1
Wood
36
UnderAttic(Unvented)
M BATH
0
Blown
241 ft2
0.1
Wood
37
UnderAttic(Unvented)
M BATH GALLER
0
Blown
80 ft2
0.1
Wood
38
Under Attic(Unvented)
WIC
0
Blown
152ft2
0.1
Wood
39
UnderAttic(Unvented)
WIC 1
0
Blown
154ft2
0.1
Wood
40
UnderAttic(Unvented)
M GALLERY
0
Blown
53 ft2
0.1
Wood
41
UnderAttic(Unvented)
EXERCISE ROO
0
Blown
154 ft2
0.1
Wood
4/22/2021 7:36 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 12
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing
Solar
Below
1
NE
Exterior
Concrete Block- Int InsuGUEST KIT/L
4.1
15
0
10
0
150.0 ft2
0
0
0.4
0
2
SE
Exterior
Concrete Block- Int InsuGLIEST KIT/L
4.1
30
0
10
0
300.0 ft2
0
0
0.4
0
3
SW
Exterior
Concrete Block- Int InsuGUEST KIT/L
4.1
15
0
10
0
150.0 ft2
0
0
0.4
0
4
SW
Exterior
Concrete Block - Int InsuGUEST BED
4.1
16
0
10
0
160.0 ft2
0
0
0.4
0
5
NW
Exterior
Concrete Block - Int InsuGUEST BED
4.1
3
0
10
0
30.0 ft2
0
0
0.4
0
6
NE
Exterior
Concrete Block - Int InsuGUEST BED
4.1
13
0
10
0
130.0 ft2
0
0
0.4
0
7
NW
Exterior
Concrete Block- Int InsuGLIEST BED
4.1
16
0
10
0
160.0 ft2
0
0
0.4
0
8
NE
Exterior
Concrete Block- Int Insul A/C 1
4.1
3
0
10
0
30.0 ft2
0
0
0.4
0
9
NE
Exterior
Concrete Block - Int InsuffHEATER G
4.1
3
0
10
0
30.0 ft2
0
0
0.4
0
_ 10
SE
Exterior
Concrete Block- Int Insull-HEATER G
4.1
3
0
10
0
30.0 ft2
0
0
0.4
0
11
SW
Exterior
Concrete Block- Int InsuRHEATER G
4.1
19
0
10
0
190.0 ft2
0
0
0.4
0
12
NW
Exterior
Concrete Block- Int InsuirHEATER G
4.1
11
0
10
0
110.0 ft2
0
0
0.4
0
13
SW
Exterior
Concrete Block- Int Insul BATH 2
4.1
5
0
10
0
50.0 ft2
0
0
0.4
0
14
NW
Exterior
Concrete Block - Int Insul BATH 2
4.1
10
0
10
0
100.0 ft2
0
0
0.4
0
15
SE
Exterior
Concrete Block- Int lnsuBONUS ROO
4.1
11
0
10
0
110.0 ft2
0
0
0.4
0
16
W
Exterior
Concrete Block- Int InsuFAMILY ROO
4.1
14
0
10
0
140.0 ft2
0
0
0.4
0
17
NW
Exterior
Concrete Block - Int InsuFAMILY ROO
4.1
2
0
10
0
20.0 ft2
0
0
0.4
0
18
SE
Exterior
Concrete Block - Int Insul GALLERY
4.1
6
0
10
0
60.0 ft2
0
0
0.4
0
_ 19
NE
Exterior
Concrete Block - Int Insul GALLERY
4.1
18
0
10
0
180.0 ft2
0
0.4
0
20
SW
Exterior
Concrete Block- Int InsdBREAKFAST
4.1
7
0
10
0
70.0 ft2
0
0
0.4
0
21
W
Exterior
Concrete Block - Int InsLIBREAKFAST
4.1
7
10
10
0
78.3 ft2
0
0
0.4
0
22
NW
Exterior
Concrete Block - Int InsLIBREAKFAST
4.1
6
0
10
0
60.0 ft2
0
0
0.4
0
_23
NE
Exterior
Concrete Block - Int Insul OFFICE
4.1
12
0
12
0
144.0 ft2
0
0
0.4
0
_24
SE
Exterior
Concrete Block- Int Insul OFFICE
4.1
15
0
12
0
180.0 ft2
0
0
0.4
0
25
NE
Exterior
Concrete Block- Int Insul DINING
4.1
16
0
12
0
192.0 ft2
0
0
0.4
0
26
SE
Exterior
Concrete Block- Int Insul DINING
4.1
13
0
12
0
156.0 ft2
0
0
0.4
0
_27
NW
Exterior
Concrete Block- Int Insul DINING
4.1
5
0
12
0
60.0 ft2
0
0
0.4
0
_28
NE
Exterior
Concrete Block- Int Insul FOYER
4.1
9
0
14
0
126.0 ft2
0
0
0.4
0
_29
NW
Exterior
Concrete Block- Int Insul FOYER
4.1
7
0
14
0
98.0 ft2
0
0
0.4
0
30
SW
Exterior
Concrete Block - Int Insi1LIVING AREA
4.1
19
0
14
0
266.0 ft2
0
0
0.4
0
_31
NW
Exterior
Concrete Block - Int InsdLIVING AREA
4.1
4
0
14
0
56.0 ft2
0
0
0.4
0
_32
NW
Exterior
Concrete Block- Int InsLIIVING AREA
4.1
4
0
14
0
56.0 ft2
0
0
0.4
0
_33
SW
Exterior
Concrete Block- Int InsLEIVING AREA
4.1
2
0
14
0
28.0 ft2
0
0
0.4
0
_ 34
NW
Exterior
Concrete Block - Int InsLILIVING AREA
4.1
7
0
14
0
98.0 ft2
0
0
0.4
0
35
NW
Exterior
Concrete Block - Int InsiILIVING AREA
4.1
7
0
14
0
98.0 ft2
0
0
0.4
0
_36
NW
Exterior
Concrete Block- Int InsdLIVING AREA
4.1
5
0
14
0
70.0 ft2
0
0
0.4
0
37
NE
Exterior
Concrete Block - Int InSLILIVING AREA
4.1
2
0
14
0
28.0 ft2
0
0
0.4
0
38
NE
Exterior
Concrete Block - Int InsuBEDROOM 2
4.1
14
0
12
0
168.0 ft2
0
0
0.4
0
39
SE
Exterior
Concrete Block- Int InsuBEDROOM 2
4.1
4
0
12
0
48.0 ft2
0
0
0.4
0
_40
NW
Exterior
Concrete Block- Int InsuBEDROOM 2
4.1
4
0
12
0
48.0 ft2
0
0
0.4
0
_41
SW
Exterior
Concrete Block- Int Insul CLOSET 5
4.1
8
0
12
0
96.0 ft2
0
0
0.4
0
42
SW
Exterior
Concrete Block - Int InsuBEDROOM 5
4.1
3
0
12
0
36.0 ft2
0
0
0.4
0
_43
SW
Exterior
Concrete Block- Int InsuBEDROOM 5
4.1
11
0
12
0
132.0 ft2
0
0
0.4
0
4/22/2021 7:36 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 12
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
*
Ornt
Adjacent Space
To Wnll Type
Cavity
Width
Height
Sheathing Framing
Solar Below
_44
SW
Exterior
Concrete Block - Int InsuBEDROOM 5
4.1
4
0
12
0
48.0 ft2
0
0
0.4
0
_ 45
SW
Exterior
Concrete Block- Int Insul BATH 5
4.1
5
0
12
0
60.0 ft2
0
0
0.4
0
_46
NW
Exterior
Concrete Block- Int Insul BATH 5
4.1
5
0
12
0
60.0 ft2
0
0
0.4
0
_ 47
SW
Exterior
Concrete Block - Int Insul BATH 5
4.1
8
0
12
0
96.0 ft2
0
0
0.4
0
_48
NW
Exterior
Concrete Block- Int InsuBEDROOM 4
4.1
14
0
12
0
168.0 ft2
0
0
0.4
0
_49
NE
Exterior
Concrete Block - Int Insul CLOSET4
4.1
8
0
12
0
96.0 ft2
0
0
0.4
0
50
NW
Exterior
Concrete Block - Int Insul CLOSET4
4.1
5
0
12
0
60.0 ft2
0
0
0.4
0
_51
NE
Exterior
Concrete Block- Int Insul UTIITY
4.1
8
0
12
0
96.0 ft2
0
0
0.4
0
52
NE
Exterior
Concrete Block - Int InsuBEDROOM 3
4.1
16
0
12
0
192.0 ft2
0
0
0.4
0
53
SE
Exterior
Concrete Block - Int InsuBEDROOM 3
4.1
8
0
12
0
96.0 ft2
0
0
0.4
0
_54
NW
Exterior
Concrete Block- Int InsuBEDROOM 3
4.1
4
0
12
0
48.0 ft2
0
0
0.4
0
_55
NW
Exterior
Concrete Block- Int Insul BATH 4
4.1
8
0
12
0
96.0 ft2
0
0
0.4
0
56
N
Exterior
Concrete Block - Int InsuMASTER BE
4.1
9
11
12
0
119.0 ft2
0
0
0.4
0
57
SE
Exterior
Concrete Block - Int InsuMASTER BE
4.1
13
0
12
0
156.0 ft2
0
0
0.4
0
_58
S
Exterior
Concrete Block- Int InsuMASTER BE
4.1
19
10
12
0
238.0 ft2
0
0
0.4
0
59
W
Exterior
Concrete Block - Int InsuMASTER BE
4.1
1.7
8
12
0
212.0 ft2
0
0
0.4
0
60
W
Exterior
Concrete Block - Int Insul M CLOSET
4.1
2
10
12
0
34.0 ft2
0
0
0.4
0
_61
SW
Exterior
Concrete Block- Int Insul TOILET
4.1
7
0
12
0
84.0 ft2
0
0
0.4
0
62
NE
Exterior
Concrete Block - Int Insul M BATH
4.1
17
0
12
0
204.0 ft2
0
0
0.4
0
63
SW
Exterior
Concrete Block - Int Insul M BATH
4.1
16
0
12
0
192.0 ft2
0
0
0.4
0
64
NW
Exterior
Concrete Block - Int Insul M BATH
4.1
15
0
12
0
180.0 ft2
0
0
0.4
0
_65
NW
Exterior
Concrete Block- Int Insul WIC 2
4.1
9
0
12
0
108.0 ft2
0
0
0.4
0
_66
SE
Exterior
Concrete Block- Int InsuM GALLERY
4.1
1
0
12
0
12.0 ft2
0
0
0.4
0
_67
N
Garage
Frame -Wood GUEST KIT/L
11
35
12
420.0ft2
0
0.23
0.4
0
DOORS
#
Ornt
DoorType Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Wood GUEST KIT/L
None
.2
.1
.1
.1 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
# Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
IntShade
Screening
1
NE 1
Vinyl Low-ESingle Yes
0.32
0.22
Y
32.9 ft2
2 ft 0 in
1 ft 4 in
None
None
2
SW 3
Vinyl Low-ESingle Yes
0.32
0.22
Y
19.3 ft2
2 ft 0 in
1 ft 4 in
None
None
3
SW 4
Vinyl Low-ESingle Yes
0.32
0.22
Y
19.3 ft2
2 ft 0 in
1 ft 4 in
None
None
4
NW 7
Vinyl Low-ESingle Yes
0.32
0.22
Y
32.9 ft2
2 ft 0 in
1 ft 4 in
None
None
5
SE 24
Vinyl Low-ESingle Yes
0.32
0.22
N
37.4 ft2
6 ft 0 in
1 ft 4 in
None
None
6
NW 12
Vinyl Low-ESingle Yes
0.32
0.22
Y
46.7 ft2
12 ft 0 in
1 ft 4 in
None
None
7
SW 11
Vinyl Low-ESingle Yes
0.32
0.22
N
24.0 ft2
6 ft 0 in
1 ft 4 in
None
None
8
W 16
Vinyl Low-ESingle Yes
0.35
0.2
Y
96.0 ft2
8 ft 0 in
1 ft 4 in
None
None
9
W 16
Vinyl Low-ESingle Yes
0.32
0.22
Y
18.0 ft2
4 ft 0 in
1 ft 4 in
None
None
10
SE 26
Vinyl Low-ESingle Yes
0.29
0.23
Y
34.5 ft2
4 ft 0 in
1 ft 4 in
None
None
4/22/2021 7:36 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 8 of 12
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt
ID
Frame
Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
IntShade
Screening
11
SE
18
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
18.0 ft2
4 ft 0 in
1 ft 4 in
None
None
12
NE
19
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
24.0 ft2
2 ft 0 in
1 ft 4 in
None
None
13
SW
20
Vinyl
Low-ESingle
Yes
0.29
0.23
Y
35.0 ft2
2 ft 0 in
1 ft 4 in
None
None
14
SW
30
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
128.0 ft2
11 ft 0 in
1 ft 4 in
None
None
15
SE
24
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
36.0 ft2
2 ft 0 in
1 ft 4 in
None
None
16
NE
28
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
17
NW
29
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
15.0 ft2
2 ft 0 in
1 ft4 in
None
None
18
NW
31
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
18.0 ft2
2 ft 0 in
1 ft 4 in
None
None
19
NW
32
Vinyl
Low-E Single
Yes
0.32
0.22
Y
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
20
NW
35
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
21
NW
36
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
16.4 ft2
6 ft 0 in
1 ft 4 in
None
None
22
NW
29
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
46.7 ft2
6 ft 0 in
1 ft 4 in
None
None
23
NE
38
Vinyl
Low-ESingle
Yes
0.9
0.23
Y
17.6 ft2
6 ft 0 in
1 ft 4 in
None
None
24
NE
38
Vinyl
Low-E Single
Yes
0.29
0.23
Y
18.2 ft2
6 ft 0 in
1 ft 4 in
None
None
25
SE
39
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
10.0 ft2
2 ft 0 in
1 ft 4 in
None
None
26
SE
39
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
15.6 ft2
6 ft 0 in
1 ft 4 in
None
None
27
SE
39
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
16.4 ft2
6 ft 0 in
1 ft 4 in
None
None
28
SW
41
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
29
SW
42
Vinyl
Low-ESingle
Yes
0.29
0.23
Y
6.0 ft2
2 ft 0 in
1 ft 4 in
None
None
30
SW
42
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
4.2 ft2
2 ft 0 in
1 ft 4 in
None
None
31
SW
43
Vinyl
Low-ESingle
Yes
0.29
0.23
Y
5.0 ft2
2 ft 0 in
1 ft 4 in
None
None
32
SW
43
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
4.0 ft2
2 ft 0 in
1 ft 4 in
None
None
33
SW
44
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
24.0 ft2
2 ft 0 in
1 ft 4 in
None
None
34
SW
45
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
5.5 ft2
2 ft 0 in
1 ft 4 in
None
None
35
SW
47
Vinyl
Low-ESingle
Yes
0.32
0.22
Y
32.9 ft2
7 ft 0 in
1 ft 4 in
None
None
GARAGE
#
FloorArea
CeilingArea
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
864 ft2
864 ft2
64 ft
loft
11
INFILTRATION
# Scope
Method
SLA
CFM 50
ELA
EgLA
ACH
ACH 50
1 Wholehouse
ProposedACH(50) .000365
6234.2
342.03
642.11
.1043
5
4/22/2021 7:36 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 9 of 12
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1 17 kBtu/hr
1
sys#1
2
Electric Strip Heat/
None
COP:1 34 kBtu/hr
2
sys#2
3
Electric Strip Heat/
None
COP:1 17 kBtu/hr
3
sys#3
4
Electric Strip Heat/
None
COP:1 17 kBtu/hr
4
sys#4
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Single SEER:16 18.8 kBtu/hr cfm
0.7 1
sys#1
2
CentralUnit/
Split
Single SEER:16 41 kBtu/hr cfm
0.7 2
sys#2
3
Central Unit/
Split
Single SEER:16 24 kBtu/hr cfm
0.7 3
sys#3
4
Central Unit/
Split
Single SEER:16 24 kBtu/hr cfm
0.7 4
sys#4
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric None
GUEST KIT/LM196 50gal 60.9gal 120deg
None
2
Electric None
Garage
0.95 50gal 60.9gal 120deg
None
3
Electric None
A/C 3
0.95 50 gal 60.9 gal 120deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
CompanyName
System Model# CollectorModel# Area
Volume
FEF
None
None
ft2
DUCTS
— Supply----
--- Return ---- Air CFM 25 CFM25
HVAC #
#
Location R-Value Area
Location
Area LeakageType Handler TOT OUT
QN RLF
Heat Cool
1
Attic 6 125 ft2
Attic
65 ft2 Prop. Leak Free A/C 1 --- cfm 27.8 cfm 0.03 0.50
1 1
2
Attic 6 325 ft2
Attic
75 ft2 Prop. Leak Free Garage --- cfm 84.4 cfm 0.03 0.50
2 2
3
Attic 6 150 ft2
Attic
65 ft2 Prop. Leak Free A/C 3 --- cfm 41.2 cfm 0.03 0.50
3 3
4
Attic 6 150 ft2
Attic
65 ft2 Prop. Leak Free M CLOSET --- cfm 41.8 cfm 0.03 0.60
4 4
4/22/2021 7:36 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 10 of 12
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
ogramableThermostat:
Fcoolln
Y
Ceiling Fans:
Jan Feb
Heatng f X}Jan Feb
Mar
Mar
A r
f APr
f
Ma
May
X Jun
4 Jun
X Jul
Jul
i
Au�X�
rl Au
Se
SeP
Oct
f Oct MNOV
Nov
Dec
Dec
H
Ventin [ ] Jan
Feb
X
X Mar
[X] A r
[
Ma
[ Jun
Jul
Aug
Se
[ Oct Nov
Dec
ThermostatSchedule: HERS
2.00_6Reference
Hours
ScheduleType
1
2
3
4
5
6
7
8
9 10 11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80 80 80
80
PM
80
80
78
78
78
78
78
78
78 78 78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78 78 78
78
PM
78
78
78
78
78
78
78
78
78 78 78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68 68 68
68
PM
68
68
68
68
68
68
68
68
68 68 66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68 68 68
68
PM
68
68
68
68
68
68
68
68
68 68 66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8lbs/sq.ft.
0 ft2
0 ft
0.3
GUEST KIT/LIVING
Default(8lbs/sq.ft.
ft2
ft
0.3
GUEST BEDROOM
Default(8lbs/sq.ft.
ft2
ft
0.3
GUEST BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
GUEST BEDROOM
Default(81bs/sq.ft.
ft2
ft
0.3
A/C 1
Default(8lbs/sq.ft.
ft2
ft
0.3
THEATER GAME R
Default(8lbs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8lbs/sq.ft.
ft2
ft
0.3
BONUS ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
FAMILY ROOM
Default(8lbs/sq.ft.
ft2
ft
0.3
GALLERY
Default(8lbs/sq.ft.
ft2
ft
0.3
BREAKFAST AREA
Default(8lbs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8lbs/sq.ft.
ft2
ft
0.3
OFFICE
Default(81bs/sq.ft.
ft2
ft
0.3
DINING
Default(8lbs/sq.ft.
ft2
ft
0.3
GALLERY.
Default(8lbs/sq.ft.
ft2
ft
0.3
FOYER
Default(8lbs/sq.ft.
ft2
ft
0.3
LIVING AREA
Default(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8lbs/sq.ft.
ft2
ft
0.3
CLOSET 5
Default(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM 5
Default(8lbs/sq.ft.
ft2
ft
0.3
BATH 5
Default(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM 4
Default(8lbs/sq.ft.
ft2
ft
0.3
CLOSET 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLOSET4
Default(8lbs/sq.ft.
ft2
ft
0.3
UTIITY
Default(8lbs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8lbs/sq.ft.
ft2
ft
0.3
A/C 3
Default(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM 3
4/22/2021 7:36 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 11 of 12
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(81bs/sq.ft.
ft2
ft
0.3
BATH 4
Default(8lbs/sq.ft.
ft2
ft
0.3
BATH 3
Default(81bs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8lbs/sq.ft.
ft2
ft
0.3
M CLOSET
Default(8lbs/sq.ft.
ft2
ft
0.3
TOILET
Default(81bs/sq.ft.
ft2
ft
0.3
M BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
M BATH GALLERY
Default(8lbs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8lbs/sq.ft.
ft2
ft
0.3
WIC 1
Default(8lbs/sq.ft.
ft2
ft
0.3
M GALLERY
Default 8lbs/s .ft.
ft2
ft
0.3
EXERCISE ROOM
4/22/2021 7:36 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 12 of 12
N i
2020 —AIR BARRIER AND I ` ULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR134•�.oRl AND INSULATION INSPECTION COMPONENT CRITERIA
I
Project Name: RODOLFO VEGA Builder Name:
Street: 1950 BRCOKSMIT RD. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner: RODOLFO VEGA Jurisdiction: ST. LUCIE COUNTY
W
Design Location: FL, Fort Pierce
411BARRIER
COMPONENT
s I CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air bar er hall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal h lope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in th air arner shall be sealed.
Ceiling/attic
The. air barrier in anyIrop.ed ceiling/soffit shall be aligned with
.
insulation and 'in the barrier be
The insulation in an dro ed ceilin /soffit
y PP gthe
angap air shall sealed.shall
be aligned with the air barrier.
Access openingsdrdo stairs or knee wall doors to
unconditioned attic sc'es all be sealed.
Walls
The junction of the fou datilend sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top, slate rid the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sea'ied'.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between win w/dookambs and framing, and
and doors
skylights and framing sh I be sealed.
Rim joists
Rim joists shall include th' air'barner.
Rim joists shall be insulated.
Floors
The air barrier shall be ins al led at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
1
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind pul2ung and wiring-
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall.separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrfe�shall be installed behind electrical or communication
14
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealantslshallnot be used to fill voids
between fire snrinkler cover olates I d walls or ceml*nas,
a. in addition, inspection of log Waiis shall be In accordance to the provisions dr ICG-400.
4/22/2021 7:37 AM EnergyGauge® USA 7.0.00 - 'aRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows"
Description
a. U-Factor:
Sgl, U=0.32
SHGC:
SHGC=0.22
b. U-Factor:
Sgl, U=0.29
SHGC:
SHGC=0.23
c. U-Factor:
Sgl, U=0.35
SHGC:
SHGC=0.20
d. U-Factor:
other (see details)
SHGC:
other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
1950 BRCOKSMITH RD., FT. PIERCE, FL,
New (From Plans)
10. Wall Type and Insulation
Insulation Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 7177.30 ft2
b. Frame - Wood, Adjacent
R=11.0 420.00 ft2
1
c. N/A
R= ft2
7
d. N/A
R= ft2
11. Ceiling Type and insulation level
Insulation Area
No
a. Roof Deck (Unvented)
R=20.0 6509.00 ft2
6509
b. N/A
R= ft2
Area
c. N/A
R= ft2
711.04 ft2
12. Ducts, location & insulation level
R ft2
2 additional duct system(s)
6 125
b. Sup: Attic, Ret: Attic, AH: Garage
6 325
97.68 ft2
c. Sup: Attic, Ret: Attic, AH: A/C 3
(see detail
13. Cooling systems
kBtu/hr Efficiency
96.00 ft2
a. Central Unit
18.8 SEER:16.00
b. Central Unit
41.0 SEER:16.00
17.65 ft2
2 additional cooling systems
(see details)
14. Heating systems
kBtu/hr Efficiency
a. Electric Strip Heat
17.0 COP:1.00
5.545 ft.
b. Electric Strip Heat
34.0 COP:1.00
0.219
2 additional heating systems
(see details)
Area
15. Hot water systems
ft2
a. Electric
Cap: 50 gallons
EF: 0.95
b. Conservation features
Insulation
Area
None
R=0.0
6507.00 ft2
Credits (Performance method)
Pstat
R=
ft2
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: (,qw City/FL Zip:,E-7TR57r1-a.P-=
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/22/2021 7:36 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software rjlw l fi e 1 of 1