HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: RODOLFO VEGA BuilderName: Street: 1950 BRCOKSMITH RD. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, PermitNumber: Owner: RODOLFO VEGA Jurisdiction: ST. LUCIE COUNTY DesignLocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Types(7597.3 sqft.) Insulation; Area 2. Single family or multiple family Detached a. Concrete Block- Int Insul, Exterior R=4.1 7177.30 ft2 b. Frame - Wood, Adjacent R=11.0 420.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 7 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (6509.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 6509.00 ftZ 6. Conditioned floorarea above grade (ft2) 6509 b. N/A R= ft2 Conditionedfloor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(922.4 sqft.) Description Area 12. Ducts 2 additional duct system(s) R ft2 6 125 a. U-Factor: Sgl, U=0.32 711.04 ft2 b. Sup: Attic, Ret: Attic, AH: Garage 6 325 SHGC: SHGC=0.22 c. Sup: Attic, Ret: Attic, AH: A/C 3 (seedetails b. U-Factor: Sgl, U=0.29 97.68 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.23 a. Central Unit 18.8 SEER:16.00 c. U-Factor: Sgl, U=0.35 96.00 ft2 b. Central Unit 41.0 SEER:16.00 SHGC: SHGC=0.20 2 additional cooling systems (seedetails) Area Weighted Average Overhang Depth: 5.545 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.219 a. Electric Strip Heat 17.0 COP:1.00 8. Skylights Area b. Electric Strip Heat 34.0 COP:1.00 2 additional heating systems (seedetails) c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (6507.0 sqft.) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 6507.00 ft2 b. Conservation features b. N/A R= ft2. None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.142 Total Proposed Modified Loads: 194.33 PASS Total Baseline Loads: 212.26 , I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this ��k1E;SxgT� p Code calculation indicates compliance with the Florida Energy Code. PREPARED BYQAC]�� Before construction is completed DATE: -22-2 3211 this building will be inspected for T , -- compliance with Section 553.908:' hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code.�'OD�. OWNER/AGENT: BUILDING OFFICIAL: DATE: ds^cZ DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. COO 4/22/2021 7:36 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Softwaree Page 1 of 12 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: RODOLFO VEGA Bedrooms: 7 Address Type: StreetAddress Building Type: User ConditionedArea: 6509 Lot# OwnerName: RODOLFO VEGA Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: BuilderName: RotateAngle: 0 Street: 1950 BRCOKSMITH RD Permit Office: ST. LUCIE COUNTY CrossVentilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp V DesignLocation TMY Site 97.5 % 2.5 % Winter Summer DegreeDays Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 UNIT#1 928 9280 2 UNIT #2 2812 32320 3 UNIT #3 1374 16470 4 UNIT #4 1395 16740 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 GUEST KIT/LIVING 448 4480 No 0 1 Yes Yes Yes 2 GUEST BEDROOM 206 2060 No 0 1 .1 Yes Yes Yes 3 GUEST BATH 45 450 No 0 1 No Yes Yes 4 GUEST BEDROOM 208 2080 No 0 1 1 Yes Yes Yes 5 A/C 1 21 210 No 0 1 Yes Yes Yes 6 THEATER GAME R 523 5230 No 0 1 Yes Yes Yes 7 BATH 2 50 500 No 0 1 Yes Yes Yes 8 BONUS ROOM 85 850 No 0 1 Yes Yes Yes 9 BATH 42 420 No 0 1 No Yes Yes 10 FAMILY ROOM 288 2880 No 0 1 Yes Yes Yes 11 GALLERY 120 1200 No 0 1 Yes Yes Yes 12 BREAKFAST AREA 269 2690 No 0 1 Yes Yes Yes 13 PANTRY 60 720 No 0 1 No Yes Yes 14 KITCHEN 306 3672 Yes 0 1 No Yes Yes 15 OFFICE 132 1584 No 0 1 Yes Yes Yes 16 DINING 228 2736 No 0 1 Yes Yes Yes 17 GALLERY. 44 528 No 0 1 No Yes Yes 18 FOYER 138 1932 No 0 1 Yes Yes Yes 19 LIVING AREA 527 7378 No 0 1 Yes Yes Yes 4/22/2021 7:36 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 12 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 20 BEDROOM 2 196 2352 No 2 1 1 Yes Yes Yes 21 CLOSET 5 56 672 No 0 1 No Yes Yes 22 BEDROOM 5 202 2424 No 2 1 1 No Yes Yes 23 BATH 5 65 780 No 0 1 Yes Yes Yes 24 BEDROOM 4 198 2376 No 2 1 1 Yes Yes Yes 25 CLOSET 3 28 336 No 0 1 No Yes Yes 26 CLOSET4 40 480 No 0 1 Yes Yes Yes 27 UTIITY 87 1044 No 0 1 Yes Yes Yes 28 HALLWAY 83 996 No 0 1 No Yes Yes 29 A/C 3 9 90 No 0 1 No Yes Yes 30 BEDROOM 3 251 3012 No 2 1 1 Yes Yes Yes 31 BATH 4 109 1308 No 0 1 Yes Yes Yes 32 BATH 3 50 600 No 0 1 No Yes Yes 33 MASTER BEDROO 465 5580 No 2 1 1 Yes Yes Yes 34 M CLOSET 54 648 No 0 1 Yes Yes Yes 35 TOILET 42 504 No 0 1 Yes Yes Yes 36 M BATH 241 2892 No 0 1 Yes Yes Yes 37 M BATH GALLERY 80 960 No 0 1 No Yes Yes 38 WIC 2 152 1824 No 0 1 Yes Yes Yes 39 WIC 1 154 1848 No 0 1 No Yes Yes 40 M GALLERY 53 636 No 0 1 Yes Yes Yes 41 EXERCISE ROOM 154 1848 No 0 1 No Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 1Slab-On-Grade Edge Insulation GUEST KIT/LIVIN 60ft 0 448ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulation GUEST BEDROO 19 ft 0 206 ft2 ---- 0 1 0 3Slab-On-Grade Edge Insulation GUEST BATH lift 0 45 ft2 ---- 0 1 0 4Slab-On-Grade Edge Insulation GUEST BEDROO 13ft 0 208ft2 ---- 0 1 0 5Slab-On-Grade Edge Insulation A/C 1 3 ft 0 21 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulation THEATER GAME 36 ft 0 522.5 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulation BATH 2 15 ft 0 50 ft2 ---- 0 1 0 8Slab-On-Grade Edge Insulation BONUS ROOM 11 ft 0 85ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulation BATH lift 0 42 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulation FAMILY ROOM 11.8 ft 0 288 ft2 ---- 0 1 0 11SIab-On-Grade Edge Insulation GALLERY 6 ft 0 120 ft2 ---- 0 1 0 4/22/2021 7:36 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 12 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 12SIab-On-Grade Edge Insulation BREAKFAST AR 20.8 ft 0 269 ft2 ---- 0 1 0 13SIab-On-Grade Edge Insulation PANTRY 1 ft 0 60ft2 ---- 0 1 0 14SIab-On-Grade Edge Insulation KITCHEN 1 ft 0 306ft2 ---- 0 1 0 15SIab-On-Grade Edge Insulation OFFICE 12 ft 0 132 ft2 ---- 0 1 0 16SIab-On-Grade Edge Insulation DINING 34ft 0 227.5ft2 ---- 0 1 0 17SIab-On-Grade Edge Insulation GALLERY. 1 ft 0 44 ft2 ---- 0 1 0 18SIab-On-Grade Edge Insulation FOYER 9 ft 0 138 ft2 ____ 0 1 0 19SIab-On-Grade Edge Insulation LIVING AREA 19 ft 0 527 ft2 ---- 0 1 0 20SIab-On-Grade Edge Insulation BEDROOM 2 22 ft 0 195.5 ft2 ---- 0 1 0 21SIab-On-Grade Edge Insulation CLOSET 5 1 ft 0 56 ft2 ---- 0 1 0 22SIab-On-Grade Edge Insulation BEDROOM 1 ft 0 202ft2 ---- 0 1 0 23SIab-On-Grade Edge Insulation BATH 5 10 ft 0 65 ft2 ---- 0 1 0 24SIab-On-Grade Edge Insulation BEDROOM 4 14 ft 0 198 ft2 ---- 0 1 0 25SIab-On-Grade Edge Insulation CLOSET3 , lit 0 28ft2 ---- 0 1 0 26SIab-On-Grade Edge Insulation CLOSET4 13ft 0 40ft2 ---- 0 1 0 27SIab-On-Grade Edge Insulation UTIITY 8ft 0 87ft2 ---- 0 1 0 28SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 83 ft2 ---- 0 1 0 29SIab-On-Grade Edge Insulation A/C 3 1 ft 0 9 ft2 ---- 0 1 0 30SIab-On-Grade Edge Insulation BEDROOM 3 28 ft 0 251 ft2 ---- 0 1 0 31SIab-On-Grade Edge Insulation BATH 4 8ft 0 109 ft2 ---- 0 1 0 32SIab-On-Grade Edge Insulation BATH 3 1 ft 0 50 ft2 ---- 0 1 0 33SIab-On-Grade Edge Insulation MASTER BEDRO 60.3ft 0 465ft2 ---- 0 1 0 34SIab-On-Grade Edge Insulation MCLOSET 3.8ft 0 54ft2 ---- 0 1 0 35SIab-On-Grade Edge Insulation TOILET 7 ft 0 42 ft2 ---- 0 1 0 36SIab-On-Grade Edge Insulation M BATH 48ft 0 241 ft2 ---- 0 1 0 37SIab-On-Grade Edge Insulation M BATH GALLER 1 ft 0 80 ft2 ---- 0 1 0 38SIab-On-Grade Edge Insulation WIC 2 9ft 0 152 ft2 _--- 0 1 0 39SIab-On-Grade Edge Insulation WIC 1 1 ft 0 154ft2 ---- 0 1 0 40SIab-On-Grade Edge Insulation M GALLERY 10.2 ft 0 53 ft2 ---- 0 1 0 4/22/2021 7:36 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 12 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 41SIab-On-Grade Edge Insulation EXERCISE ROO 1 ft 0 153.5ft' ---- 0 1 0 ROOF / V # Type Materials Roof Area Gable Roof Area Color Rad Barr Solar SA Emitt Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 6861 ft2 0 ft2 Unfinishe N 0.5 No 0.7 No 20 18.43 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 6509 ft2 N N 4/22/2021 7:36 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 12 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) GUEST KIT/LIVIN 0 Blown 448ft2 0.1 Wood 2 UnderAttic(Unvented) GUEST BEDROO 0 Blown 206 ft2 0.1 Wood 3 UnderAttic(Unvented) GUEST BATH 0 Blown 45 ft2 0.1 Wood 4 UnderAttic(Unvented) GUEST BEDROO 0 Blown 208 ft2 0.1 Wood 5 UnderAttic(Unvented) A/C 1 0 Blown 21 ft2 0.1 Wood 6 UnderAttic(Unvented) THEATER GAME 0 Blown 523ft2 0.1 Wood 7 UnderAttic(Unvented) BATH 0 Blown 50ft2 0.1 Wood 8 UnderAttic(Unvented) BONUS ROOM 0 Blown 85 ft2 0.1 Wood 9 UnderAttic(Unvented) BATH 0 Blown 42 ft2 0.1 Wood 10 UnderAttic(Unvented) FAMILY ROOM 0 Blown 288 ft2 0.1 Wood 11 Under Attic(Unvented) GALLERY 0 Blown 120ft2 0.1 Wood 12 UnderAttic(Unvented) BREAKFAST AR 0 Blown 269 ft2 0.1 Wood 13 UnderAttic(Unvented) PANTRY 0 Blown 60ft2 0.1 Wood 14 UnderAttic(Unvented) KITCHEN 0 Blown 306ft2 0.1 Wood 15 Under Attic(Unvented) OFFICE 0 Blown 132 ft2 0.1 Wood 16 UnderAttic(Unvented) DINING 0 Blown 228ft2 0.1 Wood 17 UnderAttic(Unvented) GALLERY. 0 Blown 44ft2 0.1 Wood 18 UnderAttic(Unvented) FOYER 0 Blown 138ft2 0.1 Wood 19 UnderAttic(Unvented) LIVING AREA 0 Blown 527 ft2 0.1 Wood 20 UnderAttic(Unvented) BEDROOM 2 0 Blown 196 ft2 0.1 Wood 21 UnderAttic(Unvented) CLOSET 5 0 Blown 56 ft2 0.1 Wood 22 UnderAttic(Unvented) BEDROOM 5 0 Blown 202 ft2 0.1 Wood 23 UnderAttic(Unvented) BATH 0 Blown 65ft2 0.1 Wood 24 UnderAttic(Unvented) BEDROOM 4 0 Blown 198 ft2 0.1 Wood 25 UnderAttic(Unvented) CLOSET 3 0 Blown 28 ft2 0.1 Wood 26 UnderAttic(Unvented) CLOSET4 0 Blown 40ft2 0.1 Wood 27 UnderAttic(Unvented) UTIITY 0 Blown 87ft2 0.1 Wood 28 UnderAttic(Unvented) HALLWAY 0 Blown 83 ft2 0.1 Wood 29 UnderAttic(Unvented) A/C 3 0 Blown 9 ft2 0.1 Wood 30 UnderAttic(Unvented) BEDROOM 3 0 Blown 251 ft2 0.1 Wood 31 UnderAttic(Unvented) BATH 4 0 Blown 109 ft2 0.1 Wood 32 UnderAttic(Unvented) BATH 3 0 Blown 50ft2 0.1 Wood 33 UnderAttic(Unvented) MASTER BEDRO 0 Blown 465ft2 0.1 Wood 34 Under Attic(Unvented) MCLOSET 0 Blown 54ft2 0.1 Wood 35 UnderAttic(Unvented) TOILET 0 Blown 42 ft2 0.1 Wood 36 UnderAttic(Unvented) M BATH 0 Blown 241 ft2 0.1 Wood 37 UnderAttic(Unvented) M BATH GALLER 0 Blown 80 ft2 0.1 Wood 38 Under Attic(Unvented) WIC 0 Blown 152ft2 0.1 Wood 39 UnderAttic(Unvented) WIC 1 0 Blown 154ft2 0.1 Wood 40 UnderAttic(Unvented) M GALLERY 0 Blown 53 ft2 0.1 Wood 41 UnderAttic(Unvented) EXERCISE ROO 0 Blown 154 ft2 0.1 Wood 4/22/2021 7:36 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 12 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE Exterior Concrete Block- Int InsuGUEST KIT/L 4.1 15 0 10 0 150.0 ft2 0 0 0.4 0 2 SE Exterior Concrete Block- Int InsuGLIEST KIT/L 4.1 30 0 10 0 300.0 ft2 0 0 0.4 0 3 SW Exterior Concrete Block- Int InsuGUEST KIT/L 4.1 15 0 10 0 150.0 ft2 0 0 0.4 0 4 SW Exterior Concrete Block - Int InsuGUEST BED 4.1 16 0 10 0 160.0 ft2 0 0 0.4 0 5 NW Exterior Concrete Block - Int InsuGUEST BED 4.1 3 0 10 0 30.0 ft2 0 0 0.4 0 6 NE Exterior Concrete Block - Int InsuGUEST BED 4.1 13 0 10 0 130.0 ft2 0 0 0.4 0 7 NW Exterior Concrete Block- Int InsuGLIEST BED 4.1 16 0 10 0 160.0 ft2 0 0 0.4 0 8 NE Exterior Concrete Block- Int Insul A/C 1 4.1 3 0 10 0 30.0 ft2 0 0 0.4 0 9 NE Exterior Concrete Block - Int InsuffHEATER G 4.1 3 0 10 0 30.0 ft2 0 0 0.4 0 _ 10 SE Exterior Concrete Block- Int Insull-HEATER G 4.1 3 0 10 0 30.0 ft2 0 0 0.4 0 11 SW Exterior Concrete Block- Int InsuRHEATER G 4.1 19 0 10 0 190.0 ft2 0 0 0.4 0 12 NW Exterior Concrete Block- Int InsuirHEATER G 4.1 11 0 10 0 110.0 ft2 0 0 0.4 0 13 SW Exterior Concrete Block- Int Insul BATH 2 4.1 5 0 10 0 50.0 ft2 0 0 0.4 0 14 NW Exterior Concrete Block - Int Insul BATH 2 4.1 10 0 10 0 100.0 ft2 0 0 0.4 0 15 SE Exterior Concrete Block- Int lnsuBONUS ROO 4.1 11 0 10 0 110.0 ft2 0 0 0.4 0 16 W Exterior Concrete Block- Int InsuFAMILY ROO 4.1 14 0 10 0 140.0 ft2 0 0 0.4 0 17 NW Exterior Concrete Block - Int InsuFAMILY ROO 4.1 2 0 10 0 20.0 ft2 0 0 0.4 0 18 SE Exterior Concrete Block - Int Insul GALLERY 4.1 6 0 10 0 60.0 ft2 0 0 0.4 0 _ 19 NE Exterior Concrete Block - Int Insul GALLERY 4.1 18 0 10 0 180.0 ft2 0 0.4 0 20 SW Exterior Concrete Block- Int InsdBREAKFAST 4.1 7 0 10 0 70.0 ft2 0 0 0.4 0 21 W Exterior Concrete Block - Int InsLIBREAKFAST 4.1 7 10 10 0 78.3 ft2 0 0 0.4 0 22 NW Exterior Concrete Block - Int InsLIBREAKFAST 4.1 6 0 10 0 60.0 ft2 0 0 0.4 0 _23 NE Exterior Concrete Block - Int Insul OFFICE 4.1 12 0 12 0 144.0 ft2 0 0 0.4 0 _24 SE Exterior Concrete Block- Int Insul OFFICE 4.1 15 0 12 0 180.0 ft2 0 0 0.4 0 25 NE Exterior Concrete Block- Int Insul DINING 4.1 16 0 12 0 192.0 ft2 0 0 0.4 0 26 SE Exterior Concrete Block- Int Insul DINING 4.1 13 0 12 0 156.0 ft2 0 0 0.4 0 _27 NW Exterior Concrete Block- Int Insul DINING 4.1 5 0 12 0 60.0 ft2 0 0 0.4 0 _28 NE Exterior Concrete Block- Int Insul FOYER 4.1 9 0 14 0 126.0 ft2 0 0 0.4 0 _29 NW Exterior Concrete Block- Int Insul FOYER 4.1 7 0 14 0 98.0 ft2 0 0 0.4 0 30 SW Exterior Concrete Block - Int Insi1LIVING AREA 4.1 19 0 14 0 266.0 ft2 0 0 0.4 0 _31 NW Exterior Concrete Block - Int InsdLIVING AREA 4.1 4 0 14 0 56.0 ft2 0 0 0.4 0 _32 NW Exterior Concrete Block- Int InsLIIVING AREA 4.1 4 0 14 0 56.0 ft2 0 0 0.4 0 _33 SW Exterior Concrete Block- Int InsLEIVING AREA 4.1 2 0 14 0 28.0 ft2 0 0 0.4 0 _ 34 NW Exterior Concrete Block - Int InsLILIVING AREA 4.1 7 0 14 0 98.0 ft2 0 0 0.4 0 35 NW Exterior Concrete Block - Int InsiILIVING AREA 4.1 7 0 14 0 98.0 ft2 0 0 0.4 0 _36 NW Exterior Concrete Block- Int InsdLIVING AREA 4.1 5 0 14 0 70.0 ft2 0 0 0.4 0 37 NE Exterior Concrete Block - Int InSLILIVING AREA 4.1 2 0 14 0 28.0 ft2 0 0 0.4 0 38 NE Exterior Concrete Block - Int InsuBEDROOM 2 4.1 14 0 12 0 168.0 ft2 0 0 0.4 0 39 SE Exterior Concrete Block- Int InsuBEDROOM 2 4.1 4 0 12 0 48.0 ft2 0 0 0.4 0 _40 NW Exterior Concrete Block- Int InsuBEDROOM 2 4.1 4 0 12 0 48.0 ft2 0 0 0.4 0 _41 SW Exterior Concrete Block- Int Insul CLOSET 5 4.1 8 0 12 0 96.0 ft2 0 0 0.4 0 42 SW Exterior Concrete Block - Int InsuBEDROOM 5 4.1 3 0 12 0 36.0 ft2 0 0 0.4 0 _43 SW Exterior Concrete Block- Int InsuBEDROOM 5 4.1 11 0 12 0 132.0 ft2 0 0 0.4 0 4/22/2021 7:36 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 12 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS * Ornt Adjacent Space To Wnll Type Cavity Width Height Sheathing Framing Solar Below _44 SW Exterior Concrete Block - Int InsuBEDROOM 5 4.1 4 0 12 0 48.0 ft2 0 0 0.4 0 _ 45 SW Exterior Concrete Block- Int Insul BATH 5 4.1 5 0 12 0 60.0 ft2 0 0 0.4 0 _46 NW Exterior Concrete Block- Int Insul BATH 5 4.1 5 0 12 0 60.0 ft2 0 0 0.4 0 _ 47 SW Exterior Concrete Block - Int Insul BATH 5 4.1 8 0 12 0 96.0 ft2 0 0 0.4 0 _48 NW Exterior Concrete Block- Int InsuBEDROOM 4 4.1 14 0 12 0 168.0 ft2 0 0 0.4 0 _49 NE Exterior Concrete Block - Int Insul CLOSET4 4.1 8 0 12 0 96.0 ft2 0 0 0.4 0 50 NW Exterior Concrete Block - Int Insul CLOSET4 4.1 5 0 12 0 60.0 ft2 0 0 0.4 0 _51 NE Exterior Concrete Block- Int Insul UTIITY 4.1 8 0 12 0 96.0 ft2 0 0 0.4 0 52 NE Exterior Concrete Block - Int InsuBEDROOM 3 4.1 16 0 12 0 192.0 ft2 0 0 0.4 0 53 SE Exterior Concrete Block - Int InsuBEDROOM 3 4.1 8 0 12 0 96.0 ft2 0 0 0.4 0 _54 NW Exterior Concrete Block- Int InsuBEDROOM 3 4.1 4 0 12 0 48.0 ft2 0 0 0.4 0 _55 NW Exterior Concrete Block- Int Insul BATH 4 4.1 8 0 12 0 96.0 ft2 0 0 0.4 0 56 N Exterior Concrete Block - Int InsuMASTER BE 4.1 9 11 12 0 119.0 ft2 0 0 0.4 0 57 SE Exterior Concrete Block - Int InsuMASTER BE 4.1 13 0 12 0 156.0 ft2 0 0 0.4 0 _58 S Exterior Concrete Block- Int InsuMASTER BE 4.1 19 10 12 0 238.0 ft2 0 0 0.4 0 59 W Exterior Concrete Block - Int InsuMASTER BE 4.1 1.7 8 12 0 212.0 ft2 0 0 0.4 0 60 W Exterior Concrete Block - Int Insul M CLOSET 4.1 2 10 12 0 34.0 ft2 0 0 0.4 0 _61 SW Exterior Concrete Block- Int Insul TOILET 4.1 7 0 12 0 84.0 ft2 0 0 0.4 0 62 NE Exterior Concrete Block - Int Insul M BATH 4.1 17 0 12 0 204.0 ft2 0 0 0.4 0 63 SW Exterior Concrete Block - Int Insul M BATH 4.1 16 0 12 0 192.0 ft2 0 0 0.4 0 64 NW Exterior Concrete Block - Int Insul M BATH 4.1 15 0 12 0 180.0 ft2 0 0 0.4 0 _65 NW Exterior Concrete Block- Int Insul WIC 2 4.1 9 0 12 0 108.0 ft2 0 0 0.4 0 _66 SE Exterior Concrete Block- Int InsuM GALLERY 4.1 1 0 12 0 12.0 ft2 0 0 0.4 0 _67 N Garage Frame -Wood GUEST KIT/L 11 35 12 420.0ft2 0 0.23 0.4 0 DOORS # Ornt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood GUEST KIT/L None .2 .1 .1 .1 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 NE 1 Vinyl Low-ESingle Yes 0.32 0.22 Y 32.9 ft2 2 ft 0 in 1 ft 4 in None None 2 SW 3 Vinyl Low-ESingle Yes 0.32 0.22 Y 19.3 ft2 2 ft 0 in 1 ft 4 in None None 3 SW 4 Vinyl Low-ESingle Yes 0.32 0.22 Y 19.3 ft2 2 ft 0 in 1 ft 4 in None None 4 NW 7 Vinyl Low-ESingle Yes 0.32 0.22 Y 32.9 ft2 2 ft 0 in 1 ft 4 in None None 5 SE 24 Vinyl Low-ESingle Yes 0.32 0.22 N 37.4 ft2 6 ft 0 in 1 ft 4 in None None 6 NW 12 Vinyl Low-ESingle Yes 0.32 0.22 Y 46.7 ft2 12 ft 0 in 1 ft 4 in None None 7 SW 11 Vinyl Low-ESingle Yes 0.32 0.22 N 24.0 ft2 6 ft 0 in 1 ft 4 in None None 8 W 16 Vinyl Low-ESingle Yes 0.35 0.2 Y 96.0 ft2 8 ft 0 in 1 ft 4 in None None 9 W 16 Vinyl Low-ESingle Yes 0.32 0.22 Y 18.0 ft2 4 ft 0 in 1 ft 4 in None None 10 SE 26 Vinyl Low-ESingle Yes 0.29 0.23 Y 34.5 ft2 4 ft 0 in 1 ft 4 in None None 4/22/2021 7:36 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 8 of 12 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 11 SE 18 Vinyl Low-ESingle Yes 0.32 0.22 Y 18.0 ft2 4 ft 0 in 1 ft 4 in None None 12 NE 19 Vinyl Low-ESingle Yes 0.32 0.22 Y 24.0 ft2 2 ft 0 in 1 ft 4 in None None 13 SW 20 Vinyl Low-ESingle Yes 0.29 0.23 Y 35.0 ft2 2 ft 0 in 1 ft 4 in None None 14 SW 30 Vinyl Low-ESingle Yes 0.32 0.22 Y 128.0 ft2 11 ft 0 in 1 ft 4 in None None 15 SE 24 Vinyl Low-ESingle Yes 0.32 0.22 Y 36.0 ft2 2 ft 0 in 1 ft 4 in None None 16 NE 28 Vinyl Low-ESingle Yes 0.32 0.22 Y 12.0 ft2 2 ft 0 in 1 ft 4 in None None 17 NW 29 Vinyl Low-ESingle Yes 0.32 0.22 Y 15.0 ft2 2 ft 0 in 1 ft4 in None None 18 NW 31 Vinyl Low-ESingle Yes 0.32 0.22 Y 18.0 ft2 2 ft 0 in 1 ft 4 in None None 19 NW 32 Vinyl Low-E Single Yes 0.32 0.22 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 20 NW 35 Vinyl Low-ESingle Yes 0.32 0.22 Y 12.0 ft2 2 ft 0 in 1 ft 4 in None None 21 NW 36 Vinyl Low-ESingle Yes 0.32 0.22 Y 16.4 ft2 6 ft 0 in 1 ft 4 in None None 22 NW 29 Vinyl Low-ESingle Yes 0.32 0.22 Y 46.7 ft2 6 ft 0 in 1 ft 4 in None None 23 NE 38 Vinyl Low-ESingle Yes 0.9 0.23 Y 17.6 ft2 6 ft 0 in 1 ft 4 in None None 24 NE 38 Vinyl Low-E Single Yes 0.29 0.23 Y 18.2 ft2 6 ft 0 in 1 ft 4 in None None 25 SE 39 Vinyl Low-ESingle Yes 0.32 0.22 Y 10.0 ft2 2 ft 0 in 1 ft 4 in None None 26 SE 39 Vinyl Low-ESingle Yes 0.32 0.22 Y 15.6 ft2 6 ft 0 in 1 ft 4 in None None 27 SE 39 Vinyl Low-ESingle Yes 0.32 0.22 Y 16.4 ft2 6 ft 0 in 1 ft 4 in None None 28 SW 41 Vinyl Low-ESingle Yes 0.32 0.22 Y 12.0 ft2 2 ft 0 in 1 ft 4 in None None 29 SW 42 Vinyl Low-ESingle Yes 0.29 0.23 Y 6.0 ft2 2 ft 0 in 1 ft 4 in None None 30 SW 42 Vinyl Low-ESingle Yes 0.32 0.22 Y 4.2 ft2 2 ft 0 in 1 ft 4 in None None 31 SW 43 Vinyl Low-ESingle Yes 0.29 0.23 Y 5.0 ft2 2 ft 0 in 1 ft 4 in None None 32 SW 43 Vinyl Low-ESingle Yes 0.32 0.22 Y 4.0 ft2 2 ft 0 in 1 ft 4 in None None 33 SW 44 Vinyl Low-ESingle Yes 0.32 0.22 Y 24.0 ft2 2 ft 0 in 1 ft 4 in None None 34 SW 45 Vinyl Low-ESingle Yes 0.32 0.22 Y 5.5 ft2 2 ft 0 in 1 ft 4 in None None 35 SW 47 Vinyl Low-ESingle Yes 0.32 0.22 Y 32.9 ft2 7 ft 0 in 1 ft 4 in None None GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 864 ft2 864 ft2 64 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000365 6234.2 342.03 642.11 .1043 5 4/22/2021 7:36 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 9 of 12 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 17 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COP:1 34 kBtu/hr 2 sys#2 3 Electric Strip Heat/ None COP:1 17 kBtu/hr 3 sys#3 4 Electric Strip Heat/ None COP:1 17 kBtu/hr 4 sys#4 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER:16 18.8 kBtu/hr cfm 0.7 1 sys#1 2 CentralUnit/ Split Single SEER:16 41 kBtu/hr cfm 0.7 2 sys#2 3 Central Unit/ Split Single SEER:16 24 kBtu/hr cfm 0.7 3 sys#3 4 Central Unit/ Split Single SEER:16 24 kBtu/hr cfm 0.7 4 sys#4 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None GUEST KIT/LM196 50gal 60.9gal 120deg None 2 Electric None Garage 0.95 50gal 60.9gal 120deg None 3 Electric None A/C 3 0.95 50 gal 60.9 gal 120deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # CompanyName System Model# CollectorModel# Area Volume FEF None None ft2 DUCTS — Supply---- --- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool 1 Attic 6 125 ft2 Attic 65 ft2 Prop. Leak Free A/C 1 --- cfm 27.8 cfm 0.03 0.50 1 1 2 Attic 6 325 ft2 Attic 75 ft2 Prop. Leak Free Garage --- cfm 84.4 cfm 0.03 0.50 2 2 3 Attic 6 150 ft2 Attic 65 ft2 Prop. Leak Free A/C 3 --- cfm 41.2 cfm 0.03 0.50 3 3 4 Attic 6 150 ft2 Attic 65 ft2 Prop. Leak Free M CLOSET --- cfm 41.8 cfm 0.03 0.60 4 4 4/22/2021 7:36 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 10 of 12 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES ogramableThermostat: Fcoolln Y Ceiling Fans: Jan Feb Heatng f X}Jan Feb Mar Mar A r f APr f Ma May X Jun 4 Jun X Jul Jul i Au�X� rl Au Se SeP Oct f Oct MNOV Nov Dec Dec H Ventin [ ] Jan Feb X X Mar [X] A r [ Ma [ Jun Jul Aug Se [ Oct Nov Dec ThermostatSchedule: HERS 2.00_6Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8lbs/sq.ft. 0 ft2 0 ft 0.3 GUEST KIT/LIVING Default(8lbs/sq.ft. ft2 ft 0.3 GUEST BEDROOM Default(8lbs/sq.ft. ft2 ft 0.3 GUEST BATH Default(8lbs/sq.ft. ft2 ft 0.3 GUEST BEDROOM Default(81bs/sq.ft. ft2 ft 0.3 A/C 1 Default(8lbs/sq.ft. ft2 ft 0.3 THEATER GAME R Default(8lbs/sq.ft. ft2 ft 0.3 BATH 2 Default(8lbs/sq.ft. ft2 ft 0.3 BONUS ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH Default(8lbs/sq.ft. ft2 ft 0.3 FAMILY ROOM Default(8lbs/sq.ft. ft2 ft 0.3 GALLERY Default(8lbs/sq.ft. ft2 ft 0.3 BREAKFAST AREA Default(8lbs/sq.ft. ft2 ft 0.3 PANTRY Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8lbs/sq.ft. ft2 ft 0.3 OFFICE Default(81bs/sq.ft. ft2 ft 0.3 DINING Default(8lbs/sq.ft. ft2 ft 0.3 GALLERY. Default(8lbs/sq.ft. ft2 ft 0.3 FOYER Default(8lbs/sq.ft. ft2 ft 0.3 LIVING AREA Default(8lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8lbs/sq.ft. ft2 ft 0.3 CLOSET 5 Default(8lbs/sq.ft. ft2 ft 0.3 BEDROOM 5 Default(8lbs/sq.ft. ft2 ft 0.3 BATH 5 Default(8lbs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8lbs/sq.ft. ft2 ft 0.3 CLOSET 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLOSET4 Default(8lbs/sq.ft. ft2 ft 0.3 UTIITY Default(8lbs/sq.ft. ft2 ft 0.3 HALLWAY Default(8lbs/sq.ft. ft2 ft 0.3 A/C 3 Default(8lbs/sq.ft. ft2 ft 0.3 BEDROOM 3 4/22/2021 7:36 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 11 of 12 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(81bs/sq.ft. ft2 ft 0.3 BATH 4 Default(8lbs/sq.ft. ft2 ft 0.3 BATH 3 Default(81bs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8lbs/sq.ft. ft2 ft 0.3 M CLOSET Default(8lbs/sq.ft. ft2 ft 0.3 TOILET Default(81bs/sq.ft. ft2 ft 0.3 M BATH Default(8lbs/sq.ft. ft2 ft 0.3 M BATH GALLERY Default(8lbs/sq.ft. ft2 ft 0.3 WIC 2 Default(8lbs/sq.ft. ft2 ft 0.3 WIC 1 Default(8lbs/sq.ft. ft2 ft 0.3 M GALLERY Default 8lbs/s .ft. ft2 ft 0.3 EXERCISE ROOM 4/22/2021 7:36 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 12 of 12 N i 2020 —AIR BARRIER AND I ` ULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR134•�.oRl AND INSULATION INSPECTION COMPONENT CRITERIA I Project Name: RODOLFO VEGA Builder Name: Street: 1950 BRCOKSMIT RD. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: RODOLFO VEGA Jurisdiction: ST. LUCIE COUNTY W Design Location: FL, Fort Pierce 411BARRIER COMPONENT s I CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air bar er hall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal h lope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in th air arner shall be sealed. Ceiling/attic The. air barrier in anyIrop.ed ceiling/soffit shall be aligned with . insulation and 'in the barrier be The insulation in an dro ed ceilin /soffit y PP gthe angap air shall sealed.shall be aligned with the air barrier. Access openingsdrdo stairs or knee wall doors to unconditioned attic sc'es all be sealed. Walls The junction of the fou datilend sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top, slate rid the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sea'ied'. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between win w/dookambs and framing, and and doors skylights and framing sh I be sealed. Rim joists Rim joists shall include th' air'barner. Rim joists shall be insulated. Floors The air barrier shall be ins al led at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing 1 members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pul2ung and wiring- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall.separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrfe�shall be installed behind electrical or communication 14 exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealantslshallnot be used to fill voids between fire snrinkler cover olates I d walls or ceml*nas, a. in addition, inspection of log Waiis shall be In accordance to the provisions dr ICG-400. 4/22/2021 7:37 AM EnergyGauge® USA 7.0.00 - 'aRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Sgl, U=0.32 SHGC: SHGC=0.22 b. U-Factor: Sgl, U=0.29 SHGC: SHGC=0.23 c. U-Factor: Sgl, U=0.35 SHGC: SHGC=0.20 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 1950 BRCOKSMITH RD., FT. PIERCE, FL, New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 7177.30 ft2 b. Frame - Wood, Adjacent R=11.0 420.00 ft2 1 c. N/A R= ft2 7 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area No a. Roof Deck (Unvented) R=20.0 6509.00 ft2 6509 b. N/A R= ft2 Area c. N/A R= ft2 711.04 ft2 12. Ducts, location & insulation level R ft2 2 additional duct system(s) 6 125 b. Sup: Attic, Ret: Attic, AH: Garage 6 325 97.68 ft2 c. Sup: Attic, Ret: Attic, AH: A/C 3 (see detail 13. Cooling systems kBtu/hr Efficiency 96.00 ft2 a. Central Unit 18.8 SEER:16.00 b. Central Unit 41.0 SEER:16.00 17.65 ft2 2 additional cooling systems (see details) 14. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 17.0 COP:1.00 5.545 ft. b. Electric Strip Heat 34.0 COP:1.00 0.219 2 additional heating systems (see details) Area 15. Hot water systems ft2 a. Electric Cap: 50 gallons EF: 0.95 b. Conservation features Insulation Area None R=0.0 6507.00 ft2 Credits (Performance method) Pstat R= ft2 R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: (,qw City/FL Zip:,E-7TR57r1-a.P-= *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/22/2021 7:36 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software rjlw l fi e 1 of 1