Loading...
HomeMy WebLinkAboutSurveyN 1 4 CORNER SEC 17, TWP 35S,RGE 39E O N LO 0 SYMBOLS: = GUY WIRE ANCHOR = CABLE TELEVISION BOX p = CATCH BASIN ® = CATCH BASIN INLET ® = CLEANOUT © = ELECTRIC BOX ❑T = TELEPHONE BOX v = SIGN = SANITARY MANHOLE = STORM MANHOLE 5 = NUMBER OF PARKING SPACES tf = FIRE HYDRANT = LIGHT POLE ❑ = CONCRETE POWER POLE ® = BACKFLOW PREVENTOR ® = MAIL BOX = IRRIGATION VALVE = GAS VALVE = SEWER VALVE © = WATER VALVE = WELL Fwj = WATER METER '0. = WOOD POWER POLE O = SET S CAP PM" IRON ROD WITH PLASTIC ABBREVIATIONS: (C) = CALCULATED CBS = CONCRETE BLOCK STRUCTURE CMB = COMMISSIONERS' MINUTES BOOK CONC = CONCRETE CLF = CHAIN LINK FENCE (D) - DEED DE = DRAINAGE EASEMENT DEP = DEPARTMENT OF ENVIRONMENTAL PROTECTION DB - DEED BOOK FFE = FINISHED FLOOR ELEVATION FND = FOUND FPL = FLORIDA POWER & LIGHT INV = INVERT IP = 3/4" IRON PIPE IR = 5/8" IRON REBAR IRC = IRON ROD WITH PLASTIC CAP LB = LICENSE BUSINESS LS = LICENSE SURVEY (M) = MEASURED MON = MONUMENT ORB = OFFICIAL RECORD BOOK (P) = PLAT PB = PLAT BOOK PG = PAGE PCOR = PROPERTY CORNER PL = PROPERTY LINE POB = POINT OF BEGINNING POC = POINT OF COMMENCEMENT PRM = PERMANENT REFERENCE MONUMENT R/W = RIGHT-OF-WAY RCP = REINFORCED CONCRETE PIPE RGE = RANGE SEC = SECTION TWP = TOWNSHIP UE = UTILITY EASEMENT PUDE = PUBLIC UTITLITY & DRAINAGE EASEMENT R = RADIUS OF CURVE L = LENGTH OF CURVE A - DELTA OF CURVE DWI LOLn 3 rnM 21. 2 07 a< V) FJ 2 + o 3 2J 1 I x U a_ x fq Cfm m< O Z x I w w 0 z_ z Ill J JQ P, z yo o:aOw 3I ". mFO� M 4n~U N � (=j0 0 O Ftm z z w 1 SEC 17, 1TWP?35S RGE 39E 1988 435. NOT PLATTED OCCUPIED WELL & SEPTIC >75' NO INTERFERENCE NOT PLATTED (BEARING BASE) 1290.94 N89038'23"E 1290.90 N 102.39' " EMITS BY OTHERS" \ BY OTHERS" \ BUILDING NOT PLATTED \ \ WETLAND EMITS \ 'BY OTHERS" I FpE7NgCE pCpORNER 3" x OF POOR B E I \ I\ h O I \ x a POND �I ON I I N I FND IRC INTERSEC�TINCE S89723"W 854. "PLS 017'E OFSP R.'E 854. NOT PLATTED LEGAL DESCRIPTION: x�x N ro NAIL & DISK "PLS 2391" 0.31'S, 0.23'E FND IRC PLS 2391" 0.11'S,0.11'E '0r 0 N N5TEENR�SEg�CTITIONN 0o'PCORo,W V P MrnM�'. P�G 8 N �U s 8.00' 30.00' o 35.00' n $ $ c 0 35.00' 'ram 10.5r c�id 4. .33' 7.3s PROPOSED' 1"" $ -g GARAGE m R ,gam 3FFE=21.707.er 25' 10.00' d o, 0 B.B3' { c 15.50' I: iV 18.67' .93' h o 4 �� 3.9 ' w WE . 67' '^ $ n do §Sm ,NnOM !� B m PROPOSED g'30 5.5r0 1 STORY m CBS RESIDENCE 30.84' FFE=23.70 5r W ^o ,p \ N 1 0 H WFg 2.75' r 0 o g O a 92' 12.50' m od oho a m 18.00' J a zz DETAIL: SCALE: 1"=30' COMMENCE AT THE SOUTHWEST CORNER OF THE SOUTHEAST 1/4 OF SECTION 17, TOWNSHIP 35 SOUTH, RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA, RUN NORTH 00-21-37" WEST, ALONG THE NORTH -SOUTH 1/4 SECTION LINE, A DISTANCE OF 1497.50 FEET TO A POINT 1155.92 FEET SOUTH OF THE NORTHWEST CORNER OF THE SOUTHEAST 1/4 OF SAID SECTION 17; THENCE RUN NORTH 89'38'23" EAST, A DISTANCE OF 43.50 FEET, TO THE EAST RIGHT-OF-WAY LINE OF BROCKSMITH ROAD AND THE POINT OF BEGINNING; THENCE RUN NORTH 00"21'37" WEST, ALONG THE SAID EAST RIGHT -OF WAY LINE, A DISTANCE OF 560.00 FEET; THENCE RUN NORTH 89'38'23" EAST, A DISTANCE OF 1290.94 FEET, TO THE 1/4-1/4 SECTION LINE; THENCE RUN SOUTH 00'16'46" EAST, ALONG THE SAID 1/4-1/4 SECTION LINE, A DISTANCE OF 760.00 FEET; THENCE RUN SOUTH 89'38'23" WEST A DISTANCE OF 854.27 FEET; THENCE RUN NORTH 00' 21'37" WEST, A DISTANCE OF 200.00 FEET; THENCE RUN SOUTH 89'38'23" WEST, A DISTANCE OF 435.60 FEET TO THE EAST RIGHT-OF-WAY LINE OF BROCKSMITH ROAD AND THE POINT OF BEGINNING; ALL LYING AND BEING IN SECTION 17, TOWNSHIP 35 SOUTH, RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA. CONTAINING 893,555 SQUARE FEET OR 20.5132 ACRES, MORE OR LESS. 7 T 8 18 17 n ri to N 3 fV M 0 z 4 0 N 3 N M 0 z N89'41'27"E 2678.29' N89'47'260E 2670.35' S89"56'58"W 2661.29' 4-I 06 It NI 3 001 N N N OI O z S89'42'00"E 2679.43' S89'50'24"E 2670.56' a 0' M F V N Y O 00 m N 0I. z N r; Tf - 9, S89 5352"W 2662.9 SECTIONAL BREAKDOWN SCALE: 1 "=800' 8 9 17 16 (O N w 0 O IEn a t� N W m O 0 1n 17 16 20 21 SURVEY REPORT: 1. THIS IS A BOUNDARY SURVEY AS DEFINED IN CHAPTER 5J-17.050(11), FLORIDA ADMINISTRATIVE CODE. 2. SURVEY BASED ON ST. LUCIE COUNTY SECTIONAL DATA AND EXISITNG MONUMENTATION. 3. LEGAL DESCRIPTION WAS FURNISHED BY CLIENT, 4. BEARING BASIS: A "GRID NORTH" BEARING OF N89'38'22"E ALONG THE NORTH PROPERTY LINE. 5. NO UNDERGROUND UTILITIES OR IMPROVEMENTS WERE LOCATED UNLESS OTHERWISE SHOWN. 5. THIS SITE LIES WITHIN FLOOD ZONE "X" ACCORDING TO THE FLOOD INSURANCE RATE MAP, COMMUNITY PANEL NO. 12111CO165 J, EFFECTIVE DATE 2-16-12. 7. FLOOD ZONE SHOWN HEREON IS AN INTERPRETATION BY THE SURVEYOR AND IS PROVIDED AS A COURTESY. THE FLOOD ZONE SHOULD BE VERIFIED BY A DETERMINATION AGENCY. 8. THERE MAY BE ADDITIONAL EASEMENTS AND/OR RESTRICTIONS NOT SHOWN ON THIS SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF ST. LUCIE COUNTY. NO SEARCH OF THE PUBLIC RECORDS HAS BEEN PERFORMED BY ALEXANDER J. PIAZZA PSM, INC. 9. THE EXPECTED USE OF THE SUBJECT PROPERTY IS FOR THE CONSTRUCTION OF A SINGLE FAMILY DETACHED RESIDENCE AND FALLS WITHIN THE SUBURBAN CATEGORY AS CLASSIFIED IN CHAPTER 5J-17.051(2) FLORIDA ADMINISTRATIVE CODE. ALL FIELD -MEASURED CONTROL MEASUREMENTS EXCEEDED 1:5000 FEET ACCURACY REQUIREMENTS FOR THIS CLASSIFICATION. ALL SURVEY MEASUREMENTS ARE IN ACCORDANCE WITH THE UNITED STATES STANDARD IN FEET. 10. ALL MAPPED FEATURES SHOWN HEREON ARE UNDER THE DIRECT SUPERVISION AND RESPONSIBILITY OF ALEXANDER J. PIAZZA PSM, INC. 11. SURVEY MAP AND REPORT OR THE COPIES THEREOF ARE NOT VALID WITHOUT THE ORIGINAL SIGNATURE AND SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 12. ADDITIONS OR DELETIONS TO THE SURVEY MAP OR REPORT BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES. 13. THE BEARINGS SHOWN HEREON ARE RELATIVE TO THE STATE PLANE COORDINATE SYSTEM OF THE NORTH AMERICAN DATUM OF 1983 (2007 ADJUSTMENT) AND THE ELEVATIONS SHOWN HEREON ARE BASED ON THE NORTH AMERICAN VERTICAL DATUM OF 1988 AND ARE REFERENCED TO THE LENGEMANN OF FLORIDA'S L-NET GPS NETWORK DEVELOPED WHICH MEETS OR EXCEEDS THE FEDERAL GEODETIC CONTROL COMMITTEE (FGCC) GUIDELINES FOR "GEOMETRIC GEODETIC ACCURACY STANDARDS AND SPECIFICATIONS FOR USING GPS RELATIVE POSITIONING TECHNIQUES" AS WELL AS THE STANDARDS OF PRACTICE SET FORTH BY THE FLORIDA BOARD OF LAND SURVEYORS IN CHAPTER 5J-17.051 FLORIDA ADMINISTRATIVE CODE, PURSUANT TO CHAPTER 472.027 FLORIDA STATUTES. BENCHMARKS SET OR FOUND FOR THIS SURVEY ARE NOTED ON THE SKETCH. 14. THIS SURVEY IS PREPARED ONLY FOR THE PARTIES LISTED BELOW AND IS NOT ASSIGNABLE. CERTIFIED TO: RODOLFO VEGA & CARMEN HERNANDEZ 15. @ COPYRIGHT 2021 BY ALEXANDER J. PIAZZA PSM, INC. HE SKETCH OF SURVEY AND SURVEY REPORT COMPRISE THE COMPLETE SURVEY. THIS SURVEY IS NOT VALID UNLESS THE SKETCH AND REPORT ACCOMPANY EACH OTHER. REPRODUCTIONS OF THIS SURVEY ARE NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER EMPLOYED BY ALEXANDER J. PIAZZA PSM, INC. ALEXANDER J. PIAZZA PSM, INC. n e L•� N,wp DATE OF FIELD SURVEY: DATE OF SURVEY: 1-25-21 SITE PLAN // ALEXANDIE PIZZA PROFESSIONAL SURVEYOR AND MAPPER FLORID CERTIFICATE N�v 330 ALEXANDER J. PIAZZA PSM, INC. Surveying Mapping Consulting 619 SW Biltmore Street ® Port St. Lucie, Florida 34983 Phone: (772) 340-7770 LB%7280 Fax: (772) 340-2250 BOUNDARY SURVEY 1950 SOUTH BROCKSMITH ROAD SEC 17, TWP 35S, RGE 39E AS PREPARED FOR RODOLFO VEGA & CARMEN HERNANDEZ CAD K:\13UILOERS\DWG2020\20-5963 REF K:\ FLO CJM / RP FB. PG. JOB 20-5963 OFF CJM/AJP DATE 2-11-21 DATE: REVISIONS: 8Y: CKD AJP SHEET 1 OF 1 DWG D-958