Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL WINDOWS SINGLE HUNG Florida Building Code Online https://floridabuflding.org/pr/pr_app_cltl.aspx?param=wGEVX QwtDqt... 3. I j L- BCIS Horre Log In User Registration Hot Topics Subnit Surcharge Stats &Facts Publications Contact Us BCISSkeMap Links SE Florida Product Approval Florida r4 USER:Public User P roduct pproval M e nu> P rodL]Ct or Application Se arch> Ap.p lication L is t> Appi i c at!on De tal I - -7 FL # FL14095-Rll LI, Application Type Affirmation I Code Version 2020 Application Status Approved Comments Archived Product Manufacturer JELD-WEN Address/Phone/Email 3737 Lakeport Blvd Klamath Falls, OR 97601 (800) 535-3936 fbcl@jeld-wen.com Authorized Signature Rylee Sumner Fricks fbcl@jeld-wen.com Technical Representative J E L D-WE N Corporate Customer Service 1 of 6 6/30/21, 14:17 Florida Building Code Online https://floridabuilding.orcVpr/pr_app_dtl.aspx?param=wGEVXQwtDgt... Address/Phone/Email 3737 Lakeport Blvd. Klamath Falls, OR 97601 (800) 535-3936 customerserviceagents@jeld-wen.com Quality Assurance Representative Ad d ress/Ph on e/E m ai I Categ ory Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By I affirm that there are no changes in the new Florida Buildii Code which affect my product(s) and my product(s) are in compliancewith the new Florida Building Code. 2of6 6/30/21, 14:17 Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt... Documentation from approved Evaluation or Validation Entity 'Yes ' No N/A Product Approval Method Method 1 Option A Date Submitted 07/29/2020 Date Val idated 07/29/2020 Date Pending FBC Approval Date Approved 07/31/2020 Summary of Products FL # Model, Description Number or Name 14095.1 Premium Single Hung (8100) 36"x 72" Insulated Glass(5/16 in PVB or SGP Lam - 1/8 out Annealec Atlantic Vinyl Limits of Use Certification Agency Certificate Approved for use in FL14095_R11_C CAC_N1011567.04-R3.pdf HVHZ: Yes Quality Assurance Contract Expiration Date Approved for use outside 04/30/2025 HVHZ: Yes Installation Instructions Impact Resistant: Yes F1_14095_R11_II_FL14095_R5_II_DP65-70 36x72_Impact_Installation_Instructions.pdf Design Pressure: +65/-70 FL14095_R11_II_N1011567.04-R3 Dwgs07252017.pdf Other: Laminated glazing Verified By: Hermes Norero, PE 73778 interlayer material Created by Independent Third Party: Yes requirements meet the current Evaluation Reports edition of the FBC in FL14095_R11_AE_PER3094.pdf accordancewith Miami-Dade Created by Independent Third Party: Yes NOA for DuPont SentryGlas and DuPont PVB interlayers. White PVC exterior extrusion meet the current edition of the FBC in accordance with 3 of 6 6/30/21, 14:17 1 Florida Building Code Online https://floridabuilding.orcVpr/pr_app_dtl.aspx?param=wGEVXQwtDgt... Miami-Dade NOA for Quanex. IG back bedded with Dow 995. Safety glazing required to the exterior at heights above 30 feet. 14095.2 Premium Single Hung (8100) 36"x 72" Insulated Glass(1/8 in - 1/8 out Annealed) Atlantic Vinyl Limits of Use Certification Agency Certificate Approved for use in FL14095_R11_C_CAC_N1011567.08-Ri.pdf HVHZ: Yes FL14095_R11_C_CAC 1\11011567.09-R2.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ: Yes 04/30/2025 Impact Resistant: No Installation Instructions Design Pressure: +651-70 FL14095_R11_II_N1011567.09-R2 Dwgs07252017.pdf Other: White PVC exterior FL14095_R11_II_PAV TSH FBC 36x72 SS 2017-06-26.pdf extrusion meet the current Verified By: Hermes Norero, PE 73778 edition of the FBC in Created by Independent Third Party: Yes accordance with Miami-Dade Evaluation Reports NOA for Quanex. IG back FL14095_R11_AE_PER4869 SS 2017-06-26.pdf bedded with Dow 995. Safety Created by Independent Third Party: Yes glazing required to the exterior at heights above 30 feet. 14095.3 Premium Single Hung (8100) 52 1/8"x 75" Insulated Glass(3/16 in -3/16 out Annealed) Atlantic Vinyl Limits of Use Certification Agency Certificate Approved for use in FL14095 R11 C CAC 1\11011567.06-R1.pdf HVHZ: Yes FL14095_R11_C_CAC_N1011567.07-R2.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ: Yes 04/30/2025 Impact Resistant: No Installation Instructions Design Pressure: +65/-70 FL14095_R11_II_N1011567.07-R2 Dwgs07252017.pdf Other: White PVC exterior FL14095_R11_II_PAV TSH FBC 52x75 SS 2017-06-26.pdf extrusion meet the current Verified By: Hermes Norero, PE 73778 edition of the FBC in Created by Independent Third Party: Yes accordance with Miami-Dade Evaluation Reports NOA for Quanex. IG back FL14095_R11_A_E_PER4870 SS 2017-06-26.pdf bedded with Dow 995. Created by Independent Third Party: Yes 4 of 6 6/30/21, 14:17 Florida Building Code Online https://floridabuilchng.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt... wider than 36" require setting blocks. Safety glazing required to the exterior at heights above 30 feet. 14095.4 Premium Single Hung (8100) 52 1/8"x 75" Insulated Glass(5/16 in PVB or SGP Lam - 1/8 out Atlantic Vinyl Annealed) Limits of Use Certification Agency Certificate Approved for use in FL14095_R11_C_CAC_N1011567.02-R2.pdf HVHZ: Yes Quality Assurance Contract Expiration Date Approved for use outside 04/30/2025 HVHZ: Yes Installation Instructions Impact Resistant: Yes FL14095_R11_II_FL14095_R5_II_DP50-60 52.125x75_Imp act_Installation_Instructions Design Pressure: +50/-60 FL14095_R11_1_I_NI011567.02-R2 Dwgs07252017.pdf Other: Laminated glazing Verified By: Hermes Norero, PE 73778 interlayer material Created by Independent Third Party: Yes requirements meet the current Evaluation Reports edition of the FBC in FL14095_R11_AE_PER3091.pdf accordance with Miami-Dade Created by Independent Third Party: Yes NOA for DuPont SentryGlas and DuPont PVB interlayers. White PVC exterior extrusion meet the current edition of the FBC in accordance with Miami-Dade NOA for Quanex. IG back bedded with Dow 995. Windowswith insulated glass wider than 36" require setting blocks. Safety glazing required to the exterior at heights above 30 feet. 14095.5 Premium Single Hung (8100) 52 1/8"x 75" Insulated Glass(5/16 in SGP Lam - 3/16 out Annealed) Atlantic Vinyl Limits of Use Certification Agency Certificate Approved for use in FL14095 R11 C CAC N1011567.01-R1.pdf HVHZ: Yes FL14095_R11_C_CAC_N1011567-R1.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ: Yes 04/30/2025 Impact Resistant: Yes Installation Instructions Design Pressure: +65/-75 FL14095_R11_II_FL14095_R5_11_DP65-75_52.125x75_Impact_lnstallation_Instructions 5 of 6 6/30/21, 14:17 1 Florida Building Code Online https://floridabuilding.orcVpr/pr_app_dtl.aspx?param=wGEVXQwtDgt... Other: Laminated glazing FL14095_R11_II_N1011567.01-R1 Dwgs07252017.pdf interlayer material Verified By: Hermes Norero, PE 73778 requirements meet the current Created by Independent Third Party: Yes edition of the FBC in Evaluation Reports accordance with Miami-Dade FL14095_R11_A_E_PER3095.pdf NOA for DuPont SentryGlas Created by Independent Third Party: Yes and DuPont PVB interlayers. White PVC exterior extrusion meet the current edition of the FBC in accordance with Miami- Dade NOA for Quanex. IG back bedded with Dow 995. Wndowswith insulated glass wider than 36" require setting blocks. Safety glazing required to the exterior at heights above 30 feet. Back Next Contact Us ::2601BlairStone Road,Talahassee FL 32399 Phone:850-487-1824 The State of Florida is anAA/EEO employer.Copyrfght2007-2013 State of Florida.::Privacy State rrent::Access biGty Statement::Refund Statement Under Florida law,a oral addresses are public records.If you do not want your a-nail addres s released in response to a public-re cords request,do not send electronic this entity.Instead,contactthe office by phone orby tradi[bnalrral.If you have any questions,please contact850.487.1395.*Pursuant to Section 455.275(1),Florid Statutes,effective October1,2012,licensees licensed underChapter455,F.S.rrust provide the Department with an email address if they have one.The en-ails; pro\, rray be used forofficialcomrunicatlonwith the licensee.H oweveremailaddresses are public record.If you do notwish to supply a personal address,please provid( Department with an emaladdress which can be rrade available to the public.To detemrine if you area licensee underChapter455,F.S.,please click here . Product Approval Accepts: MIMI W] ON Ed 1021 Credit Card Safe q 6of6 6/30/21, 14:17 NOTICE OF PRODUCT CERTIFICATION CERTIFICATION NO: NI011567.04-113 DATE: 05/23/2013 . 1 CERTIFICATION PROGRAM: Structural COMPANY: JELD-WEN CODE: 1822-1 ppoo REVISION DATE: 01/13/2017 To verily that the"Notice of'Product Certification"is valid,please visit www.NAivIICertification.con)to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION JELD-WEN "Premium Atlantic Vinyl Single Hung(8100)" 3737 Lakeport Boulevard Impact Rated Vinyl Single Hung Window Klamath Falls, OR 97601 (Fin or Flange Installation) Configuration:O/X Glazing: IG-1/8" Annealed GlassiLaminate- 1/8"Annealed Glass/0.090"PV13 Interlayer by DuPont/ I/S"Annealed Glass or IG-1/8"Annealed Glass/Laminate- I/S" annealedGlass/0.090"SentryGlas Plus by DuPont/ 1/8"Annealed Glass (mime: W-914tnm(36") 1-I-1829mm(72") Sash: W-845mn)(33.25") 11-483nurt(34.75") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: +65/-70 psf Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories Report No: NC'I'L-210-3875-1 Expiration Date: April 30, 2025 Date: 0o: 30014 BUILDING DROPS .g Report No: 94 ( A Perfect Solution in Every Drop Certificate of Authorization:29578 Manufacturer: JELD-WEN, Inc. Product Category: Windows Product Sub-Category: Single Hung Compliance Method: State Product Approval Method (1)(a) Product Name: Premium Atlantic Vinyl Single Hung—Impact (Impact) 36"x 72" (O/X) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WEN, Inc. based on Method la of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions NCTL210-3875-1-FBC, signed and sealed by Hermes F. Norero, P.E. (FL# 73778) for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current Florida Building Code and does not require an impact resistant covering. BUILDING DROPS Date: 0 : 30 4 Report No Date: : 94 A Perfect Solution in Every Drop Certificate of Authorization:29578 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization #: QUA 1789). Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories NW (FBC Organization# TST9341) Report#: NCTL-210-387S-1, Report Date: 4/18/2013 2. Certification Agency National Accreditation and Management Institute (FBC Organization #: CER 1773) 3. Material Certification Miami Dade RER—Product Control Section NOA E.I. DuPont De Nemours& Co., Inc.: PVB Interlayer 4. Material Certification Miami Dade RER—Product Control Section NOA Quanex Building Products: PVC Extrusions BUILDING DROPS Date: 08/11/2014 Report No: 3094 A Perfect Solution in Every Drop Certificate of Authorization:29578 Through Frame Installation: 1. Approved anchor types and substrates are as follows: A. For concrete (Min. fc= 3000 psi) or masonry substrate (Min. f c= 1500 psi) where one by(1X), non-structural, wood bucking is employed, use (1)3/16"diameterlTW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. B. For concrete (Min. fc= 3000 psi) or masonry substrate (Min. fc= 1500 psi)where wood bucking is NOT employed, use (1)3/16"diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For steel substrate, use (1)#8 Tek Screw type steel frame (min. 18ga.) anchors per location of sufficient length to achieve minimum three threads of penetration beyond steel structure. Nail Fin Installation (Where applicable): A. For wood substrates (Min. S.G. =0.42) use (1) #10 Wood Screw type installation anchors per location of sufficient length to achieve a minimum embedment of 1.50" into the wood su bstrate. Refer to Installation Instructions (NCTL210-3875-1-FBC)for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure Positive 65 PSF Negative _ 70 PSF BUILDING DROPS Date: 08/11/2014 Report No: 3094 A Perfect Solution in Every Drop Certificate of Authorization:29578 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization#: QUA 1789). Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories NW (FBC Organization# TST9341) Report#: NCTL-210-3875-1, Report Date: 4/18/2013 2. Certification Agency National Accreditation and Management Institute (FBC Organization #: CER 1773) 3. Material Certification Miami Dade RER—Product Control Section NOA E.I. DuPont De Nemours & Co., Inc.: PVB Interlayer 4. Material Certification Miami Dade RER—Product Control Section NOA Quanex Building Products: PVC Extrusions �rR MAX. w STEEL INSTALLATION CO RNERs 1 M CtST.a1, i ! FOR oR Eo6E.vz" i <� Fc.sr frame 1S• O.C. ! Id gauge min -MAX THRIJ Strel Stoll I JAMB Ii 19 gouge I ! 5tec SIUd 1!4"MAX I it SHIM SPACE I 1/4"MAX SHIM 5PACE 2Zmm I F1 1 i I MIN.DISTANCE `z i zm� FOR EDGE 1/2- mm 3n I — f t:�ll Mfn,embedment ! n o ! of Three threads n __T i Past frame s a ,•/ GI.3 6 SITE I i li Gmm i A,6; f GLAZING DETAIL JAMB SECTION(TYP) i I ( FRAME SECTION(TYP) HORIZONTAL SECTION VERTICAL 5ECTION A 1/4'MAX V I SHIM SPACE AST CmomORNERS i I 1>3 gauac n uin + PREMIUM ATLANTIC VINYL SH WINDOW i o';hrcefh'cadt Max Frame DP RATING IMPACT I WINDOW WIDTH(Da-WAX.) Past frame I ! 36 x 72 +65/-70 1 YES . I I MIN.UISTAN E I TYPICAL ELEVATION WITH FASTENER SPACING je FOR EDSE 1 z LARGE MISSILE IMPACT Installation Notes: General Notes: 1. Seal flangelframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. For anchoring into metal framing use#8 TEK Self Tapping screws with sufficient length to achieve a of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida minimum embedment of three threads past the frame thickness. Steel substrate min. 18ga.,fy=33 ksi. Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing is 3mm annealed-11 mm airspace-3mm annealed-2mm PVB Inlerlayer by DuPont-3mm annealed. project of installation. 4. Use structural or composite shims where required. This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does S� ,Q i� PRo)ECT ENGINEER: DATE. not address he sealing consideration that may arise in different wall �� Q` ••'' i� �i -- 08/13/2014 3737 Lakeport Blvd ••\ .• �$`' '\` i JELD Klarnath Falls, OR, 97601 conditions. For the complete installation procedure,see the instructions .r \, J;. DRA4\'N N'r: SCALE: packaged with the window or go to D. Vezo NTS Phone: (541)882-3451 Na, 7778` _ CHECKED by; HILL LE. tewnv.jeld wen.comlresourceslinslallation• = * * _ J. Kantola DISCLAIMER: 10 STATE / 1, ;' A_.r,,a,, dY Premium Atlantic Vinyl Impact Single Hung Window This drawing and Its contents are confidential and are not to be � 0,•'•.��OR�pP•' � � PAR lrrsac,=c t N: reproduced or copied in whole or in part or used or disclosed to others '�� "&P.E.,No-41L'o �" D008729except as authorized by JELD-INEN Inc. 398 e� lu�a. *- to 338 IDENTIFIER No. PLAN'. NAMEAND LOGAT1oN 1D DWC No.: RED': >t1EET3doa NCTL210-3875- -FBC 00 +OF 398 E. Dania Beach Blvd. BUILDING DROPS Suite338 A Perfect Solution in Every Drop Dania Beach, FL 33004 -j 954.399.8478 PH Certificate of Authorization:29578 954.744.4738 FX contact@buildingdrops.com Product El"valutation Report Of J ELD-WEN Inc. Premium Atlantic Vinyl Single Hung - Impact for Florida Product Approval Report No. 309 Current Florida Building Code Method: 1 — A ( erti cate) Category: Windows Sub — Category: Single Hung Product: Premium Atlantic Vinyl Single Hung - Impact Material: PVC Product Dimensions: 36"z 7219(0/X) Prepared For: lnc. Prepared by: BUILDING DROPS Date: 0 : 30 4 Report No Date: : 94 A Perfect Solution in Every Drop Certificate of Authorization:29578 Manufacturer: JELD-WEN, Inc. Product Category: Windows Product Sub-Category: Single Hung Compliance Method: State Product Approval Method (1)(a) Product Name: Premium Atlantic Vinyl Single Hung—Impact (Impact) 36" x 72" (O/X) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WEN, Inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions NCTL210-3875-1-FBC, signed and sealed by Hermes F. Norero, P.E. (FL# 73778) for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current Florida Building Code and does not require an impact resistant covering.