Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 5305 DEER RUN DRIVE,FT. PIERCE,FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft2) Conditioned floor area below grade (ft2) 7. Windows" Description a. U-Factor. Sgl, U=0.65 SHGC: SHGC=0.25 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description U-Factor:(AVG) N/A SHGC(AVG): N/A 9. Floor Types Insulation a. Slab -On -Grade Edge Insulation R= 0.0 b. N/A R= c. N/A R= Addition 10. Wall Types(310.0 sqft.) Insulation Area Detached a. Concrete Block - Int Insul, .ExteriorR=4.1 310.00 ft2 1 b. N/A R= ft2 c. N/A R= ft2 0 d. N/A R= ft2 No 11. Ceiling Types(269.0 sgft.) Insulation Area 269 a. Under Attic (Vented) R=30.0 269.00 ft2 0 b. N/A R= ' ft2 _ c. N/A R= ft2 Area 12. Ducts, location & insulation level R ft2 20.00 ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 53 b. ft2 C. 13. Cooling Systems kBtu/hr Efficiency ft2 a. Central Unit 57.0 SEER:16.00 2.000 ft 0.250 14. Heating Systems kBtu/hr Efficiency Area a. Electric Strip Heat 34.0 COP:1.00 N/A ft2 15. Hot Water Systems - None required Area 269.00 ft2 a. @ U vp- Cap: N/A €- - 600t ft2 b. Conservation features ft2 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: 5 2 2 Address of New Home: 5305 DEER RUN DRIVE City/FL Zip: FT. PIERCE,FL, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/24/2021 11:56:49 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: NOELKE ADDITION Builder Name: M G/nbl a*N', Street: 5305 DEER RUN DRIVE Permit Office: City, State, Zip: FT. PIERCE, FL, Permit Number: $(C - 205' Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing Addition 10. Wall Types(310.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 310.00 ft2 3. Number of units, if multiple family 1 b. N/A R= fe 4. Number of Bedrooms 0 c. N/A R= ft2 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types(269.0 sqft.) Insulation Area 6. Conditioned floor area above grade (ft2) 269 a. Under Attic (Vented) R=30.0 269.00 ft2 Conditioned floor area below grade (ftz) 0 b. N/A R= ft2 7. Windows(20.0 sqft.) Description Area c. N/A R= ft2 12. Ducts, location & insulation level R ft2 a. U-Factor: Sgl, U=0.65 20.00 ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 53 SHGC: SHGC=0.25 b. b. U-Factor: N/A ft2 C. SHGC: c. U-Factor: N/A ft2 13. Cooling Systems kBtu/hr Efficiency SHGC: a. Central Unit 57.0 SEER:16.00 Area Weighted Average Overhang Depth: 2.000 ft Area Weighted Average SHGC: 0.250 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a.'Electric Strip Heat 34.0 COP:1.00 U-Factor:(AVG) N/A N/A ft2 SHGC(AVG): N/A 9. Floor Types Insulation Area 15. Hot Water Systems - None required a. Slab -On -Grade Edge Insulation R= 0.0 b. N/A 269.00 ft2 a. Cap: N/A @ U vp- R= c. N/A R= ft2 ft2 b. Conservation features 16. Credits None Glass/Floor Area: 0.074 Total Proposed Modified Loads: 9.62 Total Baseline Loads: 9.78, PASS I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this 9p8 Code. oelms calculation indicates compliance r PREPARED BY: c{�On with the Florida Energy Code. ���� ' . , `'; ;,.�°, Before construction is completed .. DATE: 5-24-2�21 this building will be inspected for compliance with Section 553.908 q I hereby certify that this building, as desig ed, 's i ompliance Florida Statutes. � with the Florida Energy Code. 0;7 yqg l¢�� OWNER/AGEN 4 BUILDING OFFICIAL: DATE: $� DATE: -• •r. W'1111%.auvn Uy Lne air nanaier umi manufacturer that the air handier enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402'.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 5/24/2021 11:56:43 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT 0 PROJECT Title: NOELKE ADDITION Building Type: User Bedrooms: 0 Owner: Conditioned Area: 269 Total Stories: 1 Builder Name: Worst Case: No Permit Office: Rotate Angle: 0 Jurisdiction: Cross Ventilation: Family Type: Detached Whole House Fan: New/Existing: Addition Terrain: Suburban Year Construct: Shielding: Suburban Comment: Address type: Street Address Lot M — Block/SubDivislon: — PlatBook: — Street: 5305 DEER RUN DRIVE County: St. Lucie City, State, Zip: FT. PIERCE, FL, F CLIMATE V Design Location Design Temp Tmy Site 97.5% 2.5% Int Design Temp Heating Design Daily temp tinter Summer Degree Days Moisture Range _ FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 269 2690 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _ 1 ADDITION 269 2690 No 1 Yes Yes Yes FLOORS (Total Exposed Area = 269 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Ins ADDITION 62 0 269 ft 0.304 — 0.00 0.00 1.00 IV# ROOF Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) _ 1 Hip Composition shingles 291 ft' 0 ft' Medium N 0.6 No 0.9 No 0 22.62 ATTIC # Type Ventilation Vent Ratio (1 In) Area RBS IRCC 1 Full attic Vented 150 269 ft' N N CEILING (Total Exposed Area = 269 sq.ft.) # Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type _ 1 Under Attic(Vented) ADDITION 30.0 Blown 269.0ft' 0.030 0.11 Wood 5/24/2021 11:56:43 AM EnergyGauge® USA 7.0.00 - F16Res202O FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS (Total Exposed Area = 310 sq.ft.) rOrnt# djacent Cavity Width Height Area U- Sheath Frm. Solar Below To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade Exterior Conc. Blk - Int Ins ADDITION 4.1 18.0 0 10.0 0 180.0 0.149 0 0.75 0 % _ 2 N Exterior Conc. Blk - Int.lns ADDITION 4.1 13.0 0 10.0 0 130:0 0.149 0 0.75 0 % DOORS (Total Exposed Area = 24 sq.ft.) # Omt Adjacent To Door Type Space Storms Width Height U-Value Ft In Ft In Area 1 N Exterior Insulated ADDITION None 0.46 3.00 0 8.00 0 24.0ft2 WINDOWS (Total Exposed Area = 20 sq.ft.) Wall V# Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area -Overhang-- Depth Separation Interior Shade Screening -1 N 2 Metal Low-E Single Yes 0.65 0.25 N N 20.0ft2 2.0 ft 0 in 1.0 ft 41n Drapes/blinds None F#Scpe INFILTRATION . Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00032 224 12.30 23.09 0.0987 5.0 All MASS # Mass Type Area Thickness Furniture Fraction Space _ 1 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 ADDITION HEATING SYSTEM # System Type/FI. Addition Subtype AHRI # Efficiency Capacity -Geothermal HeatPump-- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Strip Heat/Existing/co None COP: 1.00 34.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type/Fl. Addition Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block kBtu/hr drn _ 1 Central Unit/Existing/co None/Single SEER:16.0 57.0 1710 0.75 sys#1 1 HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length Recirculation Recirc Control System Type Loop Branch Pump DWHR length length power Facilities Equal DWHR Other Credits Connected Flow Eff 5/24/2021 11:56:43 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 I FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT DUCTS ion R-Value Retum---- Area Location R-Value Area Leakage Type Air Handler CTOTFM S COUTFM S HVAC ON RLF Hat Cool PDSupply--- 6.0 53 ft2 Attic 6.0 15 ftz Default Leakage Attic (Default) (Default)TEMPERATURES Thermostat: N Ceiling Fans: N Jan g]Jan [ ] Feb [X] Feb [ ] Mar [X] Mar [ ] Apr [I Apr [ ] May [X] Jun [I May Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov ]Dec Venting [ ]Jan [ ]Feb [X] Mar [X] Apr [ ] [I May [ ]Jun []Jul[ ]Jul []Jul []Aug[ ]Aug [ ] Aug [ ]Sep [ ] Sep [ ]Oct [X] Oct [X] Nov [X] Nov [X] Dec (] Dec / Thermostat Schedule: HERS 2006 Reference , V Schedule Type 1 2 3 4 5 6 Hours 7 8 9 10 11 12 ,— Cooling (WD) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 _ Heating (WD) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 ,— Heating (WEH) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 .68 68 68 5/24/2021 11:56:43 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 Project Summary Job: wrightsof® DEnf re House QUICK CALCS, INC. 317 ST. LUCIE LANE, Fr. PIERCE, FL 34946 Phone: 772-166-6799 Email: QUICKCALCS@AOL.COM For. NOELIEADDITION 5305 DEER RUN DRIVE, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db Inside db 42 OF 70 OF Outside db 90 OF OF Design TD 28 OF Inside db Design TD 75 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure Ducts 30569 Btuh Structure 25332 Btuh Central vent (0 cfm) 11071 Btuh 0 Btuh Ducts Central vent (0 dm) 13678 Btuh 0 Btuh (gone) 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 41641 Btuh Use manufacturer's data n Infiltration Rate/swin multiplier Equipmeni 0.95 sensible load 37060 Btuh Method Construction quality Simplified Average Latent CoolingEquipment Load Sizing g Fireplaces 0 Structure 3177 Btuh Duds 4448 Btuh Central vent (0 cfm) 0 Btuh Area (fl?) Heatingg Cooling 2852 2852 (none) Equipment latent load 7625 Btuh Volume (fN) 28520 28520 Airchanges/hour Equiv.AVF (cfm) 0.32 0.16 152 76 Equipment Total Load (Sen+Lat) 44685 Btuh Req. total capacity at 0.70 SHR 4A ton Heating Equipment Summary Cooling Equipment Summary Make Trade Make Carrier Model Trade CARRIER AHRI ref Cond 24ACB760ABO32 Coil FV4CNB006L Efficiency Heating input 100 EFF 11.3 AHRI ref 9119431 Efficiency 12.5 EER,16SEER Heating output kW 38534 Btuh Sensible cooling Latent cooling 39900 Btuh 17100 Btuh Temperature rise Actual airflow 18 OF 1900 cfrn Total cooling Actual airflow 57000 Btuh 1900 cfrn Airflowfador Static pressure 0.046 cfm/Btuh 0.50 in H2O Airflowfador Static pressure 0.049 cfm/Btuh 0.50 in H2O Space thermostat Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrigt•tsoft^ 2021-May2411:55:35 ACCK -• ^^ RighFSUie®Uriversal202121.0.07 RSU08101 Page 1 K1Doamer6WdghtsoftWACWOELKEADDMON.nip Calc=MJ8 FrortDoorfaces: E - wrightsoft' RighW@ Worksheet Jab: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, Fr. PIERCE, FL 34946 Phona:772-466-6799 Email:OUICKCALCS ,AOL.COM 1 Room name Entire House EXISTING HOUSE 2 wall 290.0 ft 256.0 It 3 Room height 10.0 It 10.0 ft heaVaool 4 Room dimensions 1.0 x 2590.0 ft 5 Room area 2852.0 ft2 2590.0 ft2 Ty Construction U-value Or HTM Area Load Area number (BtuhKe-9 (BtuhAP) or perimeter M (Bhih) (it) (Ebh) Heat Cod Gross NIPS Heat Cool Gross NPS Heat Cool 6 13Jk4oas 0.143 no 4.00 ,�- 119 . - 600 _.-- 564 - ` ,2256 ---- -.1234 510 495 '. 1982 1063 10t2ow 0.570 ne 15.96 4621 15 0, 239, 704 15 0 239 704 0.390 no - •10.92 10.34 21 21 .. - 229 '_. ..217 .. _ 0 ; . 0 0 .: ' U 11 13A-4ocs 113t2ow 113t2ow 0.1,u 0.570 0.570 se se 4.00 15.96 2.19 470 47.30 25 374 0 1497 -399 818 470 1182 25 374 0 1497 399 818 1182 se 15.96 2029 50 50 798 1015 50 50 798 1015 11D0_,_. 13A 4as : , 1A- low- _n_ 0390._se 0143 1270 sw sw __10.92 4.00 .35.56 10.34 21 , :219 740 70.95 41 21 :- 681 0 229 2726 1451 217 21 �- W1490 740 41 21 681 229 2726 217 1490 1Di2aw.. - 0.570 ;.'sw ,.: m:15.96 ,_ 2029 _, nr :..18 _ .._ 18 ." .:.,:.. -287 .: .2895 ;. -_ 18 0 18 1451 ;,_ : 287 2895 365 y/ F-G 13A-4ocs 1D-c2ow ID-t2ow 0.143 0.570 nw, nw' 4.00 15.96 2.19 710 46.91 25 595 0 2382 399 _- 1302 460 1173 0 370 0 1481 0 .. 810 0 0.570 nw 15.96 46.91 30 0 479 1407 30 0 479 1407 P . _ - » ID-c2ow -12C-0sw -. _. _. 0.570 _ 0.091 _nw " -" _ 15.96 255 �4621 60 _ :, 1i06 _ _ _ 0 958 -. _. 2815 60 401 0 _ 958. - _. _.. 2815 461. C ., F 16B 30md_ 22AapI ------__0.032 .�.» ____.090 1.60 2852 -- -- 2852 .----.-2555 4563 --__._2590 -. -- _ ._2590 _.. -2321_ 4144 ` ..., .. .'._,. ,.:. .., _.._._0969. -._ :.. _2769 ._, .__000 ...__ 2852 . ,,._,._290 .: .-.8031 .0 2590 7089 0 6 c)AEDexausion 2280 1788 Envelopelosslgain 25889 24078 22907 21134 12 a) Infiltration 4681 1254 4049 1085 b) Room ventilation 0 0 0 0 13 Internal 230 0 9d aoes/ot 0 0 0 er 0 0 Subtotal (lines 6 to 13) 30569 25332 26956 22219 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 30569 25332 269M 22219 15 Ductloads 36% 54% 11071 13678 36% 54% 9763 11997 Total room load 41641 39010 36719 34216 Airrequired (dm) 1900 1900 1675 1666 Calculations approved byACCA to meet all requirements of Manual J 8th Ed Aa-uA wrightsoft- 2021-May-2411:55:35 Riglt SuteV�lUriversal 2021 21.0.07 RSU08101 Page 1 KlDoamerts%WrightsoftWACWOELKEADDMON.rLp CaIc=W8 FrortDoorfaces: E -► wrightsoft° Right-M Worksheet Job: Entire House Date: By. QUICK CALCS, INC. 317 ST. LUCIE LANE, Fr.. PIERCE, FL 34946 Phore:772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name DEN STORAGE 2 E)posed Hell 27.0 ft 7.0 ft 3 Room height 10.0 It heakool 10D ft heaV000l 4 Room dimensions 18.0 x 13.0 ft 7.0 x 4D ft 5 Room area 234D ft 28.0 iP Ty Construction U-value Or HTM Area Load Area (fl?) Load number (Bfuhfij2_-M (lihihAP) or perimeter (ft) (131uh) a perimeter (ft) (Stuh) Hit C001 Gross NIPS Heat Cool Gross NIPS Heat I Cool 6 219 .. _ 278 _a__ _ 151 _0_..._ 0 ___ _ _ _ U ___ ... . 0 ID-c2ow 0.570 'no 15.96 4691 0 0 .'0 •0 0 0 0 0 11100 _. -... . _.:. 0390 -.no-. 92 70 1034 .. 27 229 :. 0 0 0 ' 0 11 13A-0as 1D-c2ow 0.143 0.570 se se 4.00 1596 2.19 47.30 _., _' 0 0 0 0 0 0 ._ .217 .0 0 0 0 0 0 .. .. _ 0 0 _ ._" . 0 0 10-c2ow 0.670 se 15.96 2029 0 0 0 0 0 0 0 0 11DO 0.390 se 10,92 10.34 0 0 0 0 0 0 0 0 13A�as 1A-clomd r 0.143 1270 sw sw 4.00 35.56 -219 7025 0 0 0 0 o 0 _- _..W0 '; :0 ._ _ .0 0 -0 _ 6 . 0 1D c1ow , •_ -_ .:..05I0 sw.:._ .. 1596 < 2029 :_ ..._; 0 ,.:_ .. 0......- '-0.._... 0 0...... 0 0 0 0 0 13A•40rs ID-c2ow 1D-c2ow 0.143 0.570 nw nw 4.00 15.96 2.19 4621 180 25 155 0 621 399 339 1173 ..' .. 70 0 _ 70 0 _ ... 280 0 .• :: .0 153 0 0.570 nw 1596 4621 0 0 0 0 0 0 0 0 1D-c2aw_ _. _. _ 0.570 nw_ , 1596 4691 0_ 0 0 0 0 0_ 0 0 P 12C0sw A.091 "_ _ : _..255 :1:06 0 0 _ 0 s_� __U __ . _ __0 _ _...._..0 _ . ___l _. 0 _ ._ ... 0 C _... _168 30md_ _.. _ ._. _.--- 0.032 -._ _ _T 0.90 1.60 234 234 210 28 25 F. 22A 0.989 _ --- .;27.69 .' .OAO ., 234 ' ._ 27 _ :._ __ ,7A8 __374 _ M ,0 ._ _._. _. _28 .. 28 � : 7 _ _.._.._ _ _ 19.4 ..._.._ ... _45 6 c) AED emersion 492 0 Envelope loss/gain 2483 2746 499 198 12 a Infiltration 501 134 130 35 b) Rcomventilation 0 0 0 0 13 Internal gains Ooarpants @ 230 0 0 0 0 Appliances/other 01 0 Subhotal(llnes6to'13) 2984 28W 629 233 Less eAwnal load 0 0 0 0 Lesstrarsliar 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2984 2880 629 233 15 Duct loads 36% 54% 1081 1555 360/6 54% 228 126 Total room load �85 424 8 57 31578 Air required (dm) 18514065 6 9 Calculations approved byACCAto meet all requirements of Manual J 8th Ed �- wr•igFrrtsoft° 2021-May-2411:55:35 19 L' Paget RighlSuii @Uriversa1202121.0.07RSU08101 KlDoamerts\WrightsaftWACWOELKEADDMON.rp Calc=WB FrortDoerfaces: E -- wrightsoft® Duct System Summary o: Entire House By QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phors:772-466-6799 Email: QUICKCALCS AOL.COM Project• • For. NOELIEADDrrION 5305 DEER RUN DRIVE, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply/ return available pressure Lowestfriction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.388 in/10011 1900 cfm 129 Supply Branch Detail Table Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.388 in/10011 1900 6M Design Htg Gg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (dm) FR (in) (in) Mal Ln (ft) Ln (ft) Trunk DEN c 4436 185 216 0.388 8 0 Ox 0 VIFx 34.0 95.0 EXISTING HOUSE h 34216 1675 1666 0 0 Ox 0 VI Fx 0 0 STORAGE h 358 39 17 0 0 ox0 VIFx 0 0 Return Branch Detail Table Name Grille Size (in) Htg (Clm) Gg (cim) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb1 ox0 1900 1900 0 0 0 0 Ox 0 VIFx Bord/da6c vahres have been manuafly ovenkkfen t -0 rF wrightsoft- 2021-May-2411:55:36 �� �M*• •��•• -qw •, Rigtt Sute®Uriversa1202121.0.07 RSUOB101 Page 1 ��...K1Doamerb\WdghlsoftWACWOELKEADDMON.np Calc=MJB FrortDoorfaces: E 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: NOELKE ADDITION Builder Name: Street: 5305 DEER RUN DRIVE Permit Office: City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Y U Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _ U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking,or floor framing cavity g insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wirint Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall on exterior wall and tubs shall separate them from the showers and tubs. be insulated. Electrical/phone bo The air barrier shall be installed behind electrical or on exterior walls communication boxes or air -sealed boxes shall be installed. HVAC register booti HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 5/24/2021 11:57:01 AM EnergyGauge® USA 7.0 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1