Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Plot Plans
PROJECT DESCRIPTION: 24 xJINKO SOLARJKM320M-60HL MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 7.68 KW DC STC ARRAY AREA: ROOF #1 - 412.99 SQ. FT APPLICABLE CODES & STANDARDS: OCCUPANCY : it CONSTRUCTION : SINGLE-FAMILY ZONING RESIDENTIAL GROUND SNOW LOAD : 0 LB/SQFT WIND EXPOSURE B WIND SPEED 180 MPH PROPERTY LI v X O v m M r Z m AUTHORITIES HAVING JURISDICTION: BUILDING N/A ZONING RESIDENTIAL UTILITY FPL EQUIPMENT SUMMARY: 24 JINKO SOLARJKM32OM-60HL MODULES 24 ENPHASE IQ7-60-2-US MICROINVERTERS O 1-STORY HOUSE (E) DRIVEWAY ROOF #1 J (24) JINKO SOLAR JKM320M-60HL MODULES I t (N) MAIN SERVICE PANEL - (E) POLE 1 PLOT PLAN WITH VICINTY MAP PV 1 SCALE: 1/32" =1'4' 2741-1 111 APPLICABLE CODES & STANDARDS: 2015 NFPA 1(FIRE CODE) 2017 NATIONAL ELECTRIC CODE FLORIDA BUILDING CODE (7TH EDITION) 33'-11 (E) TREES (E) DETACH (TYP.) (E) FENCE Co V_ Pv-1 tiVUJt vt u I V SCALE: NTS PROJECT SITE .f =Vero -Beach �A1A 4 288 1 Ffia Rcl, Fort N • � ' �Pi'er • e, FL• 3'945, USA 70` P~ rt S Lucie PV-1 VICINITY MAP SCALE: NTS SHEETINDEX PV 1 PLOT PLAN WITH VICINTY MAP PV 2 ROOF PLAN & MODULES PV-2A STRING LAYOUT & BOM PV-3 ATTACHMENT DETAIL PV-4 ELECTRICAL LINE DIAGRAM PV-4A SPECIFICATIONS & CALCULATION PV-5 VRISE CALCULATIONS PV-6+ EQUIPMENT SPECIFICATIONS REVISIONS DESCRIPTION DATE REV REVISION 04130)2021 A Signature with Seal DATE: 04/30/2021 PROJECT NAME & ADDRESS U CD N O CO r LL T 5 Z W W LLLL. � j per. LL ti 5 _� Z F5 Z W E J LLJ j rN I- m w a Co O LL SHEET NAME COVER PAGE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-1 LU U LU 1) 0 n/ L<L- UO z z n/ UL W (24) JINK 1 ROOF PLAN & MODULES PV-2 SCALE: 1/4" = 1'-0" MODULE TYPE, DIMENSIONS & WEIGHT "UMBER OF MODULES: 24 MODULES IODULE TYPE: JINKO SOLAR JKM320M-60HL IODULE WEIGHT: 41.9 LEIS IODULE DIMENSIONS: 66.30" x 39.45"=18.16SF NIT WEIGHT OF AREA: 12.30 PSF ROOF DESCRIPTION ROOF RAFTER RAFTER 3OF �,. AZIMUTH .,..,.. , ROOF MATERIAL #1 1 20° 1 184' 1 METAL 1 48" O.C. I "' 1 ARRAY AREA & ROOF AREA CALC'S II ROOF # OF AREA AREA AREA COVERED MODULES (Sq. Ft.) (Sq. Ft.) BY ARRAY (% #1 1 24 412.99 1 532.00 78 !UNCTION BOX U z Q LU m/ LL U m LEGEND JB (N) JUNCTION BOX UM (E) UTILITY METER ® (N) MAIN SERVICE PANEL (MSP) ® (N) FUSED AC DISCONNECT CB (N) ENPHASE IO COMBINER 3 - VENT, ATTIC FAN (ROOF OBSTRUCTION) C❑ ROOF ATTACHMENT CONDUIT 3� 0 M CO JINKO SOLAR JKM320M-60HL MODULES �\111I I I11/// %���`\���T `N ��, v�GENSF�•�y���i i ` * No 89045 � 5 ' STATE OF `\.5126/zl (E) UTILITY METER (E) POLE w REVISIONS DESCRIPTION DATE REV REVISION 04/302021 A Signature with Seal DATE: 04/30/2021 PROJECT NAME 8 ADDRESS LO 14. CID O L1J cM i LL EL Z Co W n W LL .-. Z Z � W .� J Uj � W N H Q o a LL SHEET NAME ROOF PLAN & MODULES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-2 LU U Iz C fl Q LL IL STRING LAYOUT & BOM BILL OF MATERIALS EQUIPMENT QT DESCRIPTION SOLAR PV MODULE 24 JINKO SOLAR JKM320M-60HL INVERTER 24 ENPHASE IQ7-60-2-US JUNCTION BOX 1 JUNCTION BOX, NEMA 3R, UL LISTED COMBINER BOX 1 ENPHASE IQ COMBINER 3 W1IQ ENVOY (X-IQ-AM 1-240-3) AC DISCONNECT 1 60A FUSED AC DISCONNECT, (2) 60A FUSES, 240V, NEMA 3R, UL LISTED ATTACHMENT 100 S-5! PROTEA BRACKET ATTACHMENT 400 1" SELF TAPPING SCREW ENPHASE Q CABLE 26 ENPHASE Q CABLE 240V (PER CONNECTOR) BRANCH TERMINATOR 2 BRANCH TERMINATOR IQ WATER TIGHT CAP 2 IQ WATER TIGHT CAPS RAILS 20 IRONRIDGE XR-10 RAIL- 14 FEET (168") BONDED SPLICE 16 BONDED SPLICE CLAMP 40 UNIVERSAL FASTENING OBJECT (UFO) CLAMP 16 STOPPER SLEEVE GROUNDING LUG 4 IRONRIDGE GROUNDING LUG (12) BRANCH #1 W U Q LU �\\11Y 11111!I//� o. ��CENg •.rye// * No 89045 �'. STATE OF ::4: i G • .� i •o'•, A, S�oiv Ea N 7 AL REVISIONS DESCRIPTION DATE REV REVISION 04130=1 A Signature with Seal DATE: 04/30/2021 PROJECT NAME & ADDRESS NT co LU O LU Uj . m ILL ccoo 0- Z < W W LL N Z W Z Fo W co LU FL JW Q 0 a ILL SHEET NAME STRING LAYOUT & BOM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-2A S5I PROTEA BRACI 1 PV-3 2 PV-3 STRUCTURAL ATTACHMENT (SIDE VIE" S5IPROTEA BRACKET ATTACHMENT DETAIL (ENLARGED VIE" O\RT I SM �//�i No 89045 STATE OF s ONA' IDGE XR-10 RAIL 8MM HEX HEAD WMASHER 1" SELF TAPPING SCREW tRUGATED METAL REVISIONS DESCRIPTION DATE REV REVISION 04ld MI A Signature with Seal DATE: 04/30/2021 PROJECT NAME & ADDRESS ,qT CID Uj O Uj �jJ M 000 Q. Z 0LL W n LLI LaIL N m u- ti ZZ L J ... 00 a J Q� 04 2 a Q 0LIL SHEET NAME ATTACHMENT DETAIL SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-3 (24) ANKO SOLAR JKM320M-60HL MODULES (1) PV BRANCH OF 12 MODULES (1) PV BRANCH OF 12 MODULES 1■■■■■■■■■■� Imo■■■■■■■■■■� 1■■■■■■■■■■� 1■■■■■■■■■■� 1■■■■■■■■■■� 1■■■■■■■■■■� IMm■■■■■■■■� 1■■■■■■■■■■� 1■■■■■■■■■■I Imm■■■■■■■■I 1■■■■■■■■■■I Isom■■■■■■■1 Ems ■i Im■■■■■■■■■I Im■■■■■■■■■� 1■■■■■■■■■■� (24) ENPHASE IQ7-60-2-US MICROINVERTERS WARNING '01 PHOTOVOLTAIC POWER OUF LABEL LOCATION: CONDUIT, RACENP.Y, ENCLOSURES. COMBINER BOX& AC DISCONNECT (PER CODE: NEC2017, 1110.3111111141 • • • LABEL LOCATION: AC DISCONNECT/ BREAKER/ POINTS OF CONNECTION (PER CODE: NEC2017.690.13(B) 0 LABELLOCATwN: AC DISCONNECT (PER CODE: NEC2017.690.53) 7❑ LABELLOCATION: RAPID SHUTDO`AN (AC DISCONNECT) PER CODE: NEC 690.56 (CK3) 1 ELECTRICAL LINE DIAGRAM PV-4 I SCALE: NTS \�N0��G E NYTyF ��i� % No 89045 :4- ZZ ► ; STATE OF % i S-�LORIVP'v�����rj�26r2� NA' Q CABLE JUNCTION BOX 600 V, NEMA 3R, C 1 UL LISTED I LABEL LOCATION: POINT OF INTERCONNECTION (PER COS: NEC 2017.705.12(B) a SOLAR PV SYSTEIM EQUIP ED 1" RAPIDSHUTDO'IhN TURN RAft TO ShITCFI TO T4E VFF'P 110N TO SMUTDOMM PV W 6Y6TE.TEM AND REWCE SxOCKHAWtD N THE ARRAY NEC 2017. 690.56(C) I e ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD BIDS$ MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: COMBINER BOW EMT ENCLOSURES/ AC DISCONNECT/MAN SERVICE PANEL (PER CODE: NEC 2017, 690.13(B)) EQUIPMENT LAYOUT 10PV ELECTRICAL SERVICE INFO. UTILITY PROVIDER: FPL MAIN SERVICE VOLTAGE: 240V MAIN PANEL BRAND: N/A MAIN SERVICE PANEL: NIA CIRCUIT BREAKER RATING: 150A MAIN SERVICE LOCATION: SOUTH SERVICE FEED SOURCE: OVERHEAD 10A/2P 20A/2P POINTOF INTERCONNECTION SUPPLY SIDE TAP AC DISCONNECT: 240V, 60AMP FUSED NEMA 3R, UL LISTED --fir- — I LM — — — — - (N) ENPHASE IQ COMBINER 3 (X-IQ-AM1-240-3) LABEL LOCATION: ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (AC DISCONNECT, MSP) PER CODE. NEC 705.12(B)(2)(3)(C) c- (3 I WIRE LEGEND PV ARRAY +VE CONDUCTOR AND L1 PV ARRAY -VE CONDUCTOR AND L2 NEUTRAL CONDUCTOR ---- EGC&GEC TO UTILITY GRID DBI-DIRECTIONAL UTILITY METER# ACID1253 1-PH, 3-W, 120V/240V (E) MAIN BREAKER TO HOUSE 240 V, 150A/2P (N) MAIN SERVICE PANEL, 1-PH, 3-W, 240V REVISIONS DESCRIPTION DATE REV REVISION I m3wml A Signature with Seal 3 i c L_-J I DATE: 04/30/2021 PROJECT NAME & ADC EXISTING GROUND ELECTRODE CONDUCTOR LABELLOCATION: POINT -OF -INTERCONNECTION OR AT MAIN SERVICE DISCONNECT (MSP) PER CODE: NEC 705.12EX2p31(B) QTY CONDUCTOR INFORMATION CONDUIT TYPE CONDUIT SIZE (4) #12AWG PV WIRE/USE-2 N/A N/A BARE COPPER (1) #6AWG IN FREE AIR (4) #10AWG THWN-2 EMT OR FLEX IN ATTIC 3/4" (1) #6AWG BARE COPPER IN FREE AIR (3) #GAWG THWN-2 EMT OR FLEX IN ATTIC 3/4" (1) #10AWG THWN-2GND � LID 0) N LLJ LLJ M o z < L` LL W W 0 N tl- ti Z � X Z W N \/ .. J F- 2 aLL Q O SHEET NAME ELECTRICAL LINE & CALCS. SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-4 SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL JINKO SOLAR JKM320M-60HL VMP 33.4 V IMP 9.59 A VOC 40.9 V ISC 10.15 A TEMP. COEFF. VOC -0.28 %/°C PTC RATING 294.4 W MODULE DIMENSION 66.30" (L) x 39.45" (W) PANEL WATTAGE 320W INVERTER SPECIFICATIONS MANUFACTURER / MODEL ENPHASE IQ7-60-2-US MAX DC SHORT CIRCUIT CURRENT 15A CONTINUOUS OUTPUT CURRENT 1.OA (240V) AMBIENT TEMPERATURE SPECS RECORD LOW TEMP 30C AMBIENT TEMP (HIGH TEMP 2%) 330C CONDUIT HEIGHT 0.5" ROOF TOP TEMP 55°C ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY -IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE DC CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO JUNCTION BOX: EXPECTED WIRE TEMP 550C TEMP. CORRECTION PER NEC TABLE 310.15 (B)(2)(a) 0.76 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC TABLE 310.15(B)(3)(a) 0.8 CIRCUIT CONDUCTOR SIZE 12AWG CIRCUIT CONDUCTOR AMPACITY PER NEC TABLE 310.15(B)(16) N/A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 15A 1.25 x Imax DERATED AMPACITY OF CIRCUIT CONDUCTOR N/A TEMP. CORRECTION PER TABLE 310.15 (B)(2)(a) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY 310.15 (B)(16) Result should be greater than (15A) otherwise less the entry for circuit Conductor size and ampacity FROM JUNCTION BOX TO IQ COMBINER 3: EXPECTED WIRE TEMP 550C TEMP. CORRECTION PER NEC TABLE 310.15 (B)(2)(a) 0.76 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC TABLE 310.15(8)(3)(a) 0.8 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY PER NEC TABLE 310.15(B)(16) 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 15A 1.25 X I max DERATED AMPACITY OF CIRCUIT CONDUCTOR 24.3A TEMP. CORRECTION PER TABLE 310.15 (B)(2)(a) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY 310.15 (13)(16) Result should be greater than (15A) otherwise less the entry for circuit conductor size and ampacity AC CONDUCTOR AMPACITY CALCULATIONS IQ COMBINER 3 TO MSP: NO. OF INVERTER 24 EXPECTED WIRE TEMP 330C TEMP. CORRECTION PER NEC TABLE 310.15 (B)(2)(a) 0.96 NO. OF CURRENT CARRYING CONDUCTORS 3 CONDUIT FILL CORRECTION PER NEC TABLE 310.15(B)(3)(a) 1 CIRCUIT CONDUCTOR SIZE 6AWG CIRCUIT CONDUCTOR AMPACITY PER NEC TABLE 310.15(B)(16) 76A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 30A 1.25 x INVERTER OUTPUT CURRENT x NO. OF MICROINVERTER DERATED AMPACITY OF CIRCUIT CONDUCTOR 72q TEMP. CORRECTION PER TABLE 310.15 (B)(2)(a) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY 310.15 (B)(16) Result should be greater than (30A) otherwise less the entry for circuit conductor size and ampacity REVISIONS DESCRIPTION DATE REV REVISION 04f302021 A Signature with Seal DATE: 04/30/2021 PROJECT NAME & ADDRESS LO zt Lj O W M < a.Z - 000 � W U¢.. WLL N Z zFn W v Lu W 0000 a W N F 2 J Q 0 a ILL SHEET NAME SPECIFICATIONS & -CALC. SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-4A Calculating AC Line Voltage Rise for IQ-7 Micros with Q Cable: Voltage rise in Q Cable from the Microinverters to the Junction Box For branch circuit #1 of 12 IQ 7 Micros, the voltage rise on the 240 VAC Q Cable is 0.84% For branch circuit #2 of 12 IQ 7 Micros, the voltage rise on the 240 VAC Q Cable is 0.84% Voltage rise from the Junction Box to the IQ Combiner box VRise = (amps/inverter x number of inverters) x (resistance in 0/ft) x (2-way wire length in ft.) = (1 amp x12 ) x (0.00129 Wft) x (24 ft x 2) = 12 amps x 0.00129 0/ft x 48 ft = 0.74 volts %VRise = 0.74 volts _ 240 volts = 0.31 % The voltage rise from the Junction Box to the IQ Combiner Box is 0.31 % Voltage rise from the IQ Combiner box to AC Disconnect VRise = (amps/inverter x number of inverters) x (resistance in 0/ft.) x (2-way wire length in ft.) = (1 amp x 24) x (0.000491 0/ft) x (5 ft. x 2) = 24 amps x 0.000491 Wft x 10 ft. = 0.12 volts %VRise = 0.12 volts _ 240 volts = 0.05% The voltage rise from the IQ Combiner Box to the AC Disconnect is 0.05% Voltage rise from the AC Disconnect to the Main Service Panel VRise = (amps/inverter x number of inverters) x (resistance in 0/ft) x (2-way wire length in ft.) = (1 amp x 24) x (0.000491 0/ft) x (5 ft x 2) = 24 amps x 0.000491 .0/ft x 10 ft = 0.12 volts %VRise = 0.12 volts _ 240 volts = 0.05% The voltage rise from the AC Disconnect to the Main Service Panel is 0.05% Total system voltage rise for all three wire sections 0.84 % + 0.31 % + 0.05% + 0.05% = 1.25% REVISIONS DESCRIPTION DATE REV REVISION 04/30=21 A Signature with Seal DATE: 04/30/2021 PROJECT NAME & ADDRESS F— M N W W M O UL Q- Z OD U W :) W N ZW Z� w N of F °- Q o SHEET NAME VRISE CALCULATIONS SHEET SIZE ANSI B 1114 X 1711 SHEET NUMBER PV-5 jinkosofar.us.rnKC� - Diamond. Cell Technology Uniquely designed high performance 5 busbar mono PERC half cell Higher Module Power Decrease in current lossyields highermodule efficiency 'DO1�1ii�1 Shade Tolerance None shade tolerance due to Win arrays PID FREE sum. Reinforced Cell prevents potential induced degradation +�+ Strength and Durability -��i Certified for high snow (5400 Pal and Wnd (2400 Pal loads • IS090012008Quality Standards • IS0140012004 Environmental Standards • OHSAS18001 Occupational Health &Safety Standards • IEC61215,IEM730certifiedproducts �9 {� ' LINEAR �} F MFOR1P/Llk!! CE AR,R NT r • UL1703 certified products 10 Year Product Warranty e 25 Year Linear Power Warranty Nomenclature: JKM335M-60HBL T W Unearperfomnncewarranty Coos Cell Code Sacleheet Coda null FVJ null wNte null Cell Normal t00% ' 97% Stondardperforirmnceiaanonly H Halt B Flack L Diemorcl ✓7°I Y°41e frOr, J/11kp 90% . tih •., . Solgps . /fie°rw°sty uJ ww ¢ i< us E�1t. CE , LISTED 802% years w,n till �• ar.c� Current Voltage 8Powe n-Voltage Temperature Dependence HIM Ti lItIRIIIIIIIIIIIIIIIIII[I a Curves (31sw) of lsc,Voa,Pmax ,>w b f2 ,w 950 � ❑ to F140 JJJ 10 I I 4 y 100 SIJ.O J Yo5 +oog �k so 0 o s +0 s zo 0 20 2s m Js as Fnxa Side Belt s0 -s 0 25 so 75 1e0 Volrn9a(V) C•IITsmp—tumM n: m `{ell Type_` __Mono,PERCDIamondCall(158.7Sx158_75mm)_. �}1 $•i I��{II Half cells' "Dimensions 20 (6 .�2Y35 .3Ox 3945�1381nch), I ..... ------- _.-__. , Weight 19.0 kg (41.9 Ibs) a Front Glass 3'2inm Alit -Reflection feat ilqq, _ 1 High Transnxsslay Lou Iron Grass i .Tempered • a • + a • Frame Anodized Aluminum Alloy - - 1 Junction Box 1P67Rated (Two, pallets One stack) ✓ Output Cables 12AWG, Anode 1525mm (60.04 In), 30pc5/pallet 60pcs/stack 780pa/40 HQ Conta ner, Cathode 1525min (60.04 in) or Customized Length Type 1 SPECIFICATIONS Module Type JKM315W60HL JKM32CM-60HL JKM325M.60HL JKM33OM-60HL JKM3351A-60HL STCNOCT STC NOCT STC NOCT STD., NOCT., STC NOCT 1 Maximum Power(Pmax) 315Wp 235Wp 320Wp 239Wp 325Wp 242Wp 330Wp 246Wp 335Wp 250Wp Maxlmum.PcwerValtage(Vmpj 332V 3f.2V 93.4V 31AV 33:6V 31,6V 33.8V 31AV 34OV 3_ OV; Maxlmu m Power Current amp) 9 49A 7.56A 9.59A 7.62A 9.68A 7 66A 9 77A, 7 74A 9 87A 7 82A , Open arcult Voltage (Voc) . ' 40 7V 37.6V 40.9V 37.8V 41.1V 38 0V 413V- 38 2V 41.5V 38 4V I Short-circuit Current asc) 10 04A 8.33A 10.15A 8.44A 10.20A 8 54A 10.31A 8 65A 10 36A a 74A Module:EfficencySTC (%} - 18.67%, - 1886% , _1926% 4956%,_ .. - . _..,19.85%..., Operating Temperature (°C) 40 C +85°C Maxinuirll System Voltage, 1000VDC U, 1000VDC tEC Maxmtum Series Fuse Rating 20A Power Tolerance 0 +3% Temperature Coefficients of Pmax -0.36%PC Temperature Coefficients of Voe 0 28 NOfC Temperature Coefficients of Isc 0.048%PC IN filial 0peratmg-Cell Tempe ature (NOCT) STC: '.Irradiance 100OW/m2 [ Cell Temperature 25°C AM=1.5 NOCT: ;Irradiance800W/m' Ambient Temperature ZO•C� AM=1.5 41 Wind Speedlm/s • Power measurement tolerance: t 3% CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Q Jinko Solar Co., Ltd. All rights reserved. Specifications included in this datasheet are subject to change without notice. JKId1315-335M-60H L-A1-U S REVISIONS DESCRIPTION DATE REV REVISION 04/W2021 A Signature With Seal DATE: 04/30/2021 PROJECT NAME & ADDRESS F• LO N O cM < LL- (L Z 00 W W .-. ND L L LL Z Z W ... V! .. Ix CN J Q of 0 n. LL SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-6 Data Sheet Enphase Microinverters Region: AMERICAS Enphase 10 7 and IQ 7+ Microinverters. 9 To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready -Enphase IQ 7 Micro' and Enphase IQ 7+ Micro' dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'", Enphase IQ Battery'", and the Enphase Enlighten' monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell and 72-cell* modules More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell modules. v ENPHASE. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module,pairings' . 235 W - 350 W + 235 W - 440 W + Module compatibility 61 PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V '60 V Peak power tracking voltage 27 V- 37 V 27 V- 45 V Operating range 16 V • 48 V 16 V 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module [so) ' 15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L--L) voltage/rangez 240 V / .208 W' ' 240 'V /, 208 V / 211-264V 183-229V - 211-264V 183-229V•• Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles' 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit' 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC port lit ` Ilf AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.85leading .0.85lagging 0.85leading...0.85lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6 % 97.6 % 97.5 % 97.3 % CEC weighted efficiency 97.0 % 97.0 °i 97.0 % 97.0 % MECHANICAL DATA Ambient temperature' range -400C,to +65°C , Relative humidity range 4°i to 100°i (condensing) " c6nnectortype:(IQ7 60-2-US:& I07PLUS 72 LIS) ;MC4 (orAmphenol H4 UTX with additional Q-DCC•5 adapter) Dimensions (WXHXD) 212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.381bs) Cooling Natural convection - No fans Approved for wet locations Yes - Pollution degree PD3 Enclosure Class Il double' -insulated, corrosion resistant, polymeric enclosure . Environmental category 1 UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved, by-UL for use as the load -break disconnect required by NEC 690: Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class 8, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at https'Heriphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com 0" EN PH/4S E. 2019 Enphase Energy. All rights resewd. All trademarks or brands used are the property of Enphase Energy, Inc. 2019-3-26 REVISIONS DESCRIPTION DATE REV REVISION 04/30/2021 A Signature with Seal DATE: 04/30/2021 PROJECT NAME & ADDRESS 0) co W W M O ao a. ZLLJ 0 LL. W N LL U Z ZW 00 J LU CO F Q 0 la SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PW Data Sheet Enphase Networking Enphase 10 Combiner 3 (X-IQ-AM1-240-3) U� LISTED To learn more about Enphase offerings, visit enohase.com The Enphase IQ Combines 3"' with Enphase IQ Envoy'" consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart Includes IQ Envoy for communication and control Flexible networking supports Wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC bridge Provides production metering and optional consumption monitoring Simple Reduced size from previous combiner Centered mounting brackets support single stud mounting Supports back and side conduit entry Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) 80 A total PV or storage branch circuits Reliable Durable NRTL-certified NEMA type 3R enclosure Five-year limited warranty UL listed Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 1Q Combiner 3 with Enphase IQ Envoy' printed circuit board for integrated revenue grade PV X-IQ-AM1-240-3 , production metering (ANSI C12.20 +/- 0.5%) and optional* consumption monitoring (+/- 2.51/6). ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Enphase Mobile Connect' CELLMODEM-03 (4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G/5-year data plan) microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, CELLMODEM-M1 (4G based LTE-M/5- year data plan) where there is adequate cellular service in the installation area.) • Consumption Monitoring* CT Split core current transformers enable whole home consumption metering (+/- 2.5%). CT-200-SPLIT * consumption monitoring is required for Enphase Storage Systems Wireless USB adapter Installed at the IQ Envoy.. For communications with Enphase Encharge"' storage and Enphase COMMS-KIT-01 Enpower' smart switch. Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner'" and allows redundant wireless communication with Encharge and Enpower. . Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. BRK-10A-2-240 Circuit breaker, 2 pole, 10A, Eaton BR210 BRK-15A-2-240 Circuit breaker, 2 pole,15A, Eaton BR215 BRK-20A-2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power line carrier (communication bridge pair); quantity - one pair XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS 'Rating Continuous duty System voltage 1201240 VAC, 60 Hz 'Eaton BR series busbar rating 125 A Max. continuous current rating (output to grid) 65 A Max. fuse%circuit rating (output) 90 A Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. continuous current.rating (input from PV) 64 A Max. total branch circuit breaker rating (input) BOA of distributed generation / 90A with IQ Envoy breaker included . _ Production Metering,CT ... ,-. _b 200 A solid core pre -installed and wired to IQ Envoy , MECHANICAL DATA 'Dimensions (1WHxD) 49.5 x 37.5 x 16.8 cm (19.5" x 14.75" x 6 63"). Height 'is 21.06" (53.5'cm with mounting brackets).' Weight 7.5 kg (16.5 lbs) Ambient temperature range -400 C to +46q C (-400 to, 115* F) Cooling Natural convection, plus heat shield 'Enclosure environmental rating ' Outdoor, NRTL-certified, NEMAtype '3R, polycarbonate construction wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main tug combined output: 10 to 2/0 AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6;560,feet) : - INTERNET CONNECTION OPTIONS Integrated Wi-FP• 802.11b/g/n Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Cellular Optional,,CELLMOOEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-M1 (4G based LTE-M) (not included) COMPLIANCE Compliance, Combiner UL 1741, CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B; ICES 003 Production metering: ANSI C12.20 accuracyclass0:5 (PV:production) Compliance, IQ Envoy UL 60601-1/CANCSA 22.2 No. 61010-1 To learn more about Enphase offerings, visit enphase.corn ©2018 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 3, and other trademarks or service names are the trademarks of Enphase Energy, Inc. �� �• 2019-11-04 �,� REVISIONS DESCRIPTION DATE REV REVISION 04/30/2021 A Signature with Seal DATE: 04/30/2021 PROJECT NAME & ADDRESS LID 0) N W W M co a. 00 a. Z < iL OD D W LL W N Z Z fz C W Ll l Ll.l 00 IL J� N I_— 2 Q O d SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11rr X 17" SHEET NUMBER PV-8 Each ProteaBracket— comes with a factory -applied, i adhesive rubber sealant on the base. A structural A2 stainless steel bimetal attachment bracket, ProteaBracket is compatible with most common metal roofing materials. All four pre -punched holes must be used to achieve tested strength. Mounting hardware is furnished with the ProteaBracket. For design -assistance, ask your distributor, or visit www.5-5.com for the independent lab test data that can be used for load -critical designs and applications. Also, please visit our website for more: information including metallurgical compatibilities and specifications. S-510 holding strength is unmatched in the industry. Multiple'Attachment Options: Side Rail Option PP1 otea CSC li ary II eS " 2.27" 0.97" (57.66 mm)�f 124.64 mm) " )/ 1.00'�O� r (25.40 mm) 0.33" (8.38 mm) Factory Applb 0.33" (8.38 mm) Thru Hole 41c 0.27"l6,86 mm ,� `(991mm) 2.39" (60.71 m/3.93" mm) ` Please note: All measurements are rounded to the second decimal place. Example Applications Top-RailOption S-5-PV Kit demonstrated with a ProteaBracket on a trapezoidal profile. i Example Profile S-5-PV Kit Option S-51e Warningl Please use this product responsibly) Distributed by Products are protected by multiple U.S. and foreign patents. For published data regarding holding strength, bolt torque, patents, and trademarks, visit the S-SI website at www.S.S.com. Copyright2013,Meta)!oofimmation%LteLS-S!pmducts wepatentprotected. S-Siaggressivelypmtedsitspatems,trademarks,andmpydghtsversion 112513. REVISIONS DESCRIPTION DATE I REV REVISION 04/30=21 A Signature with Seal DATE: 04/30/2021 PROJECT NAME & ADDRESS 0) N V O � Q. U - a- Z � U_ aMD =w LaLW N Z Fn ZW W 00 CV IX 2 Q 0 a IL SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11"X 17" SHEET NUMBER PV-9 _AL,11ROWRIDGE Silrt PlIfi i1 C�+rgtxf ci'n [ r;- - pt C-i The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails. All system types that feature the UFO family —Flush Mount, Tilt Mount and Ground Mount —are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail,resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. j , Stopper Sleeve The Stopper Sleeve snaps onto the UFO, converting it into a bonded end clamp. lbct~ �1ef UFO Family of Components 4 Universal Fastening Object (UFO) The UFO securely bonds solar modules to XR' Rails. It comes assembled and lubricated, and can fit a wide range o(module heights. �qs T Qne System Diagram Q UFO C Stopper Sleeve a Grounding Lug m Bonded Splice Ground Wire 4 Approved Enphase microinverters can provide equipment grounding,of IronRidge systems, eliminating the need for grounding lugs and field installed equipment ground conductors (EGC). Aminimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL Certification The IronRidge Flush Mount, Tilt Mount, and Ground Mount b Bonded Splice Systems have been listed to UL & ` Each Bonded Splice uses fi 2703 by Intertek Group plc. self -drilling scfews to Form -_ a secure connection. No bonding strap needed -`t x''aG a L 2703 is the standard for evaluating solar mounting ` systems. It ensures these devices Grounding Lug will maintain strong electrical and mechanical connections over -. Asingle Grounding Lug Bonded Attachments connects an entire row The bonding bolt attaches an extended period of time in of PV modules to the and bonds the L foot to the extreme outdoor environments. i' grounding conductor. rail. It is installed with the same socket as the rest of the system. ,4'# 1t;0t'r1Aj.1.fl"..CgMVUr;I �;. , pi eWOWS M" XR Rails d XR1000 Only I' UFO/Stopper , d d d Bonded Splice N 4e N/A ;,Grounding Lugs 1 per Row 1 per Row 1 per Array Nrtcroinverters - ; Enphase - M250-72, M250-60, M215-60, C250-72 & Power Darfon - MIG240, MIG300, G320, G640 Optimizers SolarEdge - P300, P320, P400, P405, P600, P700, P730 Fire Rating Class A Class A N/A Modules Tested or Evaluated with over 400 Framed Modules Refer to installation manuals for a detailed list. 4� err C*X t "WA=". a /W Mftf vhss+.e j.e REVISIONS DESCRIPTION DATE REV REVISION 04/302021 A Signature with Seal DATE: 04/30/2021 PROJECT NAME & ADDRESS a LL � Z J Q 0) N U M o Z < � 0Mo IJ I.r, U LLU NLL Cl) W N w 2 a OLL SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV 10 A%� IRONRIDGE XR10 Rail See Descn Lion / Length .62 .46 1.67 Section Modulus X-axis 0.136 in al Weight Number Number XR-10-132A XR-10-1328 XR10, Rail 132" (11 Feet) 4.671bs. 6000-Series XR-10-168A XR-10-1686 XR10, Rail 168" 14 Feet 5.95 lbs. XR-10-204A XR-10-204B XR10, Rail 204" (17 Feet) Aluminum 7.22 lbs. 0LL REVISIONS DESCRIPTION DATE REVVIS REVISION 04l3W2021 A Signature with Seal DATE: 04l30/2021 PROJECT NAME 8 ADDRESS � � N � Z � � aMD W W W N Z fn z W W W 0000 J M N � _ Q a SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-11 REVISIONS DESCRIPTION DATE REVVIS REVISION 04l3W2021 A Signature with Seal DATE: 04l30/2021 PROJECT NAME 8 ADDRESS � � N � Z � � aMD W W W N Z fn z W W W 0000 J M N � _ Q a SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-11