Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: Permit #: cr
Job Information
Builder: K Hovnanian Community: j �Lot:
Address: l Unit.
r ��
City: I L�C-�- State: FL Zip: FT��
House S.F. i � �� `
Avg. Ceiling Height: � � �y
Total Volume:
Air Leaksa Test Results Passing results must meet either the Performance, Prescriptive, or FRI Method
0 PRESCRIPTIVE METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate or not exceeding 7 air
change per hour at a pressure of 0.2-inch w,g. (50 pascals) in climate zones 1 and 2.
PERFORMANCE OR ERI METHOD � The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding the selected ACH(50) value, as shown on FORM R405FI J7 (Performance) or R406-2017 (ERI), section labeled as Infiltration, sub"
section ACH.
ACH(50) .specified on Form R405".2017"Energy Caic (Performance) or R406�20.17 (ERI):
Pressure & Flow Data (For Single Point)
Test #
House Pressure: Pascals
Flow: CFM (50)
Ring Used
- UFO
C 00.
ACHSO = CFM (50) x 60 / House Volume = / Method for calculating building volume;
0 Retrieved from architectural plans
12
PASS FAIL
Code Software calculated
❑ When ACH(50) is less than 3, Mechanical Ventilation installation must
0 Field measured and calculated
be verified by building department.
Testing. Testing shall be conducted in accordance with ANSI/RESNET/I[C 380 and reported at a pressure or 0.2 inch w.g. (50 pascals); testing shall be
conducted by dither individual as defined in Section 553.993(5) or (7), Florida Statues, or individuals licensed as set forth in Section 489.105(3)(f), (g), or (1) or
an approved third party, A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing
shall be performed of any time after creation of all penetrations of the building thermal envelope,
Testing Company
Company Name: RunBrook, LLC Phone: 561-510-5715
I hereby verify that the above Air Leakage esults are in accordance with the 2017 6t" Edition Florida Building Code
Energy Conservation requirement c ding to the compliance method selected above.
It
Signature of Tester. Date of Test: 7/o2//o)
Printed Name of Tester: Costagliola
License/Certification #: 3243649 Issuing Authority: RESNET
P UNBROOK
Duct Leakage Test Report
GREEN BUILDING & ENERGYTESTING
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
jurisdiction: Permit #: Qtng
Job Information
Builder: K Hovnanian Community. Lot.
Address: Unit:
City:-- ,� State: FL Zip: j 3
Duct Leakage Test Results
System 1 a Prescriptive Method cfm25 (Total)
cfm25
To qualify as "substantially leak free" Qn must be less than or equal to
System 2 cfm25 0.04 if air handler unit is installed. If air handler unit is not installed,
Qn Total must be less than or equal to 0,03. This testing method
System 3 meets the requirements in accordance with Section R403.3.3.
cfm25
Sum of any
additional systems cfm25
0 Performance / ERI Method cfm25 (Out or Total)
Total of all �i To qualify using this method, Qn must not be greater than the
systems cfm25 proposed duct leakage Qn specified on Form R405-2017 or R40&2017.
L4 - �� _ �� n
SEW Q Leakage Type selected on Form Qn specified on Form R405-2014
Total of all Total Conditioned
systems quare Footage R405-2017 (Energy Calc) or R406-2017 (Energy Calc) or 406-2017
PASS FAIL
14
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section
553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(01 (g) or (i), Florida Statutes,
Testing Company
RunBrook, LLC 561-510-5715
Company Name: Phone:
1 hereby verify that the above duct leakage testing results are in accordance with the 2017 6th Edition Florida Building Code Energy
Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
Frank Costagliola