Loading...
HomeMy WebLinkAbouthealth dept approval 5810 TANGELO FASTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Adams Homes of Northwest Florida, Inc AGENT: Benjamin Drew"s Plumbing & Drain Services PROPERTY ADDRESS: 5810 Tanqelo Dr Fort Pierce, FL 34982 LOT: 17 BLOCK: 77 APPLICATION #:AP1450597 PERMIT #:56-SF-2012257 DOCUMENT #: F11660476 DATE PAID : 01 /28/2021 FEE PMD:55.00 RECEIPT #:56-PID-4865106 SUBDIVISION: Indian River Estates ID#: 3402-610-0202-000-2 CHECKED [XI ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION [ I [013 TANK SIZE [1I 1090.00 [2I 300.00 [ 3 [023 TANK MATERIAL Polypropylene [ 3 [031 OUTLET DEVICE [ I [043 MULTI -CHAMBERED [ L.11 N I [ 3 [05I OUTLET FILTER Polylok PL-68 [ I [06I LEGEND 1, 70-143-11DC4 2. 70-156-03SC3 [ 3 [07I WATERTIGHT [ 3 [08I LEVEL [ 3 [09I DEPTH TO LID DRAINFIELD INSTALLATION [ 3 [10I AREA Ill 504 [23 SQFT [ 3 [113 DISTRIBUTION BOX HEADER X [ I [123 NUMBER OF DRAINLINES 1. 4.00 2. [ 3 [13I DRAINLINE SEPARATION [ 3 [14I DRAINLINE SLOPE [ 3 [15I DEPTH OF COVER [ 3 [16I ELEVATION [ ABOVE / BELOW IBM 13.00 [ 3 [173 SYSTEM LOCATION [ 3 [18I DOSING PUMPS 1.00 [ 3 [19I AGGREGATE SIZE [ I [203 AGGREGATE EXCESSIVE FINES [ 3 [21I AGGREGATE DEPTH FILL / EXCAVATION MATERIAL [ 3 [22I FILL AMOUNT [ 3 [233 FILL TEXTURE [ 3 [243 EXCAVATION DEPTH [ 3 [25I AREA REPLACED [ I [263 REPLACEMENT MATERIAL Comments: Comments are on page 2. CONSTRUCTION L APPROVED / DISAPPROVED nvironmental SETBACKS [ 3 [27I SURFACE WATER FT [ 3 [28I DITCHES FT [ I [29I PRIVATE WELLS FT [ I [30I PUBLIC WELLS FT [ I [31I IRRIGATION WELLS 64 FT [ I [323 POTABLE WATER 44 FT [ 3 [333 BUILDING FOUNDATIONS 6 FT [ I [34I PROPERTY LINES 10.5 FT [ I [35I OTHER FT FILLED / MOUND SYSTEM [ I [36I DRAINFIELD COVER [ 3 [37I SHOULDERS [ I [383 SLOPES [ 3 [39I STABILIZATION 06/23/2021 ADDITIONAL INFORMATION [ I [40I UNOBSTRUCTED AREA [ I [413 STORMWATER RUNOFF [ 3 [42I ALARMS [ 3 [433 MAINTENANCE AGREEMENT [ I [44I BUILDING AREA [ 3 [45I LOCATION CONFORMS WITH SITE PLAN [ I [46I FINAL SITE GRADING [ 3 [471 CONTRACTOR (Reliable Septic & Services) [ 3 [48I OTHER ADS Septic Stack-9 (9 pipes - 2 tier) ABANDONMENT [ 3 [49I TANK PUMPED [ I [50I TANK CRUSHED & FILLED FINAL SYSTEM [ APPROVED / DISAPPROVED U Environmental Sp cialist II icol Mont (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be us Incorporated: 64E-6.003, PAC EH Database v 1.0.1 AP1450597 _J St. Lucie CHD (Florida Department of He Qt. Lucie CHD orida Department of He EID2012257 DATE: 03/05/2021 DATE: 06/23/2021 Page 2 of 3 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION # : AP 145059 7 PERMIT #:56-SF-2012257 DOCUMENT # : FI 1660476 DATE PAID : 01 /28/2021 FEE PAID:55.00 RECEIPT #:56-PID-4865106 The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400 gpd. New ST, filter, DT, liberty 1/3 hp pump, and 4X42 long Trench DF installed. No violation, system ok to cover. Contractor iotified onsite. Needs final inspection for mound system, alarm check, to verify that pump wires exit DT in conduit through the riser Nall, and final site grading. =inal inspection approved. Emailed copy to building department and contractor. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1450597 EID2012257