Date:
Contractor:
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
Phone:772-462-2165 Fax:772-462-6443
BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
2 t ( Permit #: 'L o
'7,-_Q_j
Job Address: > LI S'4 K, , � d'. 1:11,-, r ( , �1 V r e- --- 1 h- 3 �- 4 S I
Construction: (\_A New Construction — Complete ( ) Existing — After Addition
House Infiltration Test Results SLC Climate Zone 2 f
CFM (50) = S 3 Test Date: C
Volume = L 1 3
ACH (50) = CFM (50) x 60 / Volume = S 2 Mechanical Ventilation required less than 3 ACH
Passing results must be & ACH (50) or less (Vrpass ( ) Fail
FCC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3,
Testing Company
Company Name: Pro -Duct Services
Address: 1915 Rio Vista Drive, Ft. Pierce, FL 3490
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2,
Signature
Printed Name: Martin Klein
License/Certification #: 5061633
COUNTY
r t Q R'1 D A
Planning & Development Services
Building 8 Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Plerce, FL 34982
772-462-2165 Fax 772462-6443
FBC ENERGY CONSERVATION CODE
Duct Sealing CertHicatlon
Prescriptive and Performance Method
Date: Permit #: _ Z t) 1 ( - O ; t ` Lot:
Contractor: f d wn l"I 7 Address: 3 �- J -"A J twj GT'C
Construcbm: %05ost Construction Test Li Roughan Test
Test Conditions: '
Date: Floor Area (ft2):
Time: tK Primary Location of Supply Ductwork AL d2
Indoor Temperature (F): Primary Location of Return Ductwork
Outdoor Temperature (F):
TOW Leakage Test (Outside)
Dud Leakage: Default ❑ Prop. Leak Free ,bfroposed On = < J 1
Test Pressure: 'L i (Pa)
Baseline Dud Pressure (optional) 0.( (Pa)
Dud Press. (Pa) Fbw Ring Fan Press Flow (cfm) Results: X"ass o Fail
InstaAed a
L S Total Leakage (cfm): e
Total Leakage per 100 sgft: C - v 7--)
CFM25 x 100 divided by the CFA = Duct Leakage CAM/100 sgfL
Testing Cornpany
Company Name: Pro -Duct Services
Address: 191 r
I hereby certify that the above Duct Sealing Leakage results demonstrate comoWm with Sr' EdIbon FBC Er gy ConservaWn requim m ent5 in aecordiltm W&
Section IZ4032.2.
i
pMW Name: Martin Klein _ ____ Lk:enselCertific:ate N: 6081833