HomeMy WebLinkAboutAPPROVED A Plans REV G carlton GR PR I8'-1" T.O.B.
2 "
0'-0" = Finished Floor
12
4 1 SLOPE
Metal roofing and underlayment Intstalled per Product Approval
as shown on sheet I over COX decking - see roof sheeting
attachment diagram on roof plan.
5/8" thick x 8"w cut
coral finished stucco bands
LEFT ELEVATION
12 5/8" thick x 8"w cut
H- coral finished stucco bands
3
5/8" thick light textured
stucco on typical concrete
block construction
SCALE: 1/4" = 1'-0"
Metal roofing and underlayment Intstalled per Product Approval
as shown on sheet I over COX decking - see roof sheeting
attachment diagram on roof plan.
3
thick light textured
stucco on typical concrete
block construction
------------------------------------------------------------- 0'-01,
Finish Columns with
5/8" thick cut coral
finished stucco bands
Truss mfg to provide level -
return to be I" short of wall
Aluminum Drip
Edge il Fascia
2" x 4" Sub -Fascia
12"
Kaycan full o vent vinyl soffit installed
per product approval form on sheet I.
12
SLOPE]4
TYPICAL SOFFIT DETAIL
RIGHT ELEVATION
SCALE: 1/4' = I'-O'
Product Approval Submittal Affidavit
Opening Schedule Swing Doors. Overhead Doors, sliding Doors. Windows t Skylights
Opening
NOA/FL
Product
Model u
Manufacturer
Glass
Attachment method
TEST
Expiration
Design Pressure
Type
NUMBER
Date
of Approved Tests
PP
1.2.3
FLU 239.4
Single Hun
g g
SH-1�OOA
PGT
5/16"
1/4" dia. tapcons w/ min. 1 3/8" penetration to be
spaced per product approval. Contractor shall adhere to
+ 65.0/-80.0 PS
44
Impact
min. edge distances specified in Product approval
A
20-1005.08
Overhead
Model 82�4/811
1e'-2' max. width
p,qg
note x ue to concrete blockwith i filled callwit
U $5 bar vert. wing 3/8' x L' Hlti HLC Sleeve anchors at 8' o.c.
th 1.25' dia. we with min. 4' edge distance. Install track to buck
3-21-22
+40.0/-44.0 PSF
Garage Door
g
IL'-2" max height
g
Door C Om en
rig (1) 5/IL' x 1 5/8' full thread lag xrews,n each bracket maintaining
min. of 1.5' edge distance - GC to strictly adhere to product approval
rovide 1/IL' u nut washer on roller afts.
B
FLU 15213.1
Fiberglass
Smooth
Plast-Pro
1/4" dia. tapcon with min 1.25" embedment at L" max
from corners and 14.5" o.c. max. thereafter in jambs.
+65.0/-10.0
Fiberglass
C
F L 4 251.�4
Sliding Glass
Series -110
SGp
PGT
I" nom
1/4" dia. tapcons w/ min. 1 3/4" penetration to be
spaced per product approval. Contractor shall adhere to
+ 60.0 PSF
Door
Type GSA
min. 2 1/2" edge distances specified in Product approval
-
Product
NOA/FL
Model
Manufacturer
Attachment Method
TEST
Expiration
Design Pressure
9
NUMBER
Date
of Approved Tests
For CMU use (2) 1/4" x 2 3/4" tapcons with min 1 1/4" embedment
Mullions
FLU 15353.8
CM-18531
vertical mullion
MI Windows
and doors
penetration into each Mull Clip. Attach mull to clip using (4) 410 x 1.25"
self tapping screws per clip as shown in product approval.
+ 118.9 PSF
_
Roof
FLU 33818.2
5V Crim p
Metal Roofing
Gulf Coast Supply
2L a. 5v crimp metal roofing attached to plywood deck using #9-15 x 1.5"
HWH wood screws with self sealing washer at 12" o.c. max spacing per System
Roof Zone
1/2E/2R:
and manufacturing
g
no. 5V-Type I for max pressure -94.25 pat. Install per system 1( type 2
for
- q�f.25 PSF
max. pressure of -131.0 psf. Fasteners shall be installed through underlag-
ment and attached to/through wood sheeting attachment detail on roof
ppI per
plan. Plywood to be 19/32 G8X.
2N/3/3E/3R:
-131.0 PSF
Underla
FL 208�6.1
DuPont Protec 160
DuPont
Install two layers of Tyvek horizontal) in shingle style fashion using 4" and
g
L" overlaps. Install using I" dia. metal or plastic cap nails at 12" o.c. along
P g P P g
Tyvek
course and end laps an a single row 24" o.c. along middle line of the field
I.A.W. the product approval installation instructions. Stagger top layer using
24" to full
undercourse strip parallel eave edge and cover with sheet.
Overlapsuccessive sheets b 24" I.A.W. product approval installation instructiens.
Siding
Stucco on Block
Soffit
FLU 16503.1
„
12 Tripple 4
Instal using " x T battens attached to wall using 3/I6" dia.
with I" min. embedment into wall. Attach Soffit channel to wall using
Full-O-Vent Sin le
Kaycan LTD
0.091" dia. x 1.5" T-nails at 12" o.c. per detail C in P.A. Install J"
± 55.6 PSF
SPAN VINYL S_0FFI
channel to bottom of fascia using staples into soffit and same T-nails
at hem and in valle s ber detail A in P.A. (roduct a royal)
I have reviewed
the above and approved It bg mg
seal below. ( Architect or Engineer of Record )
5/8" thick x 8"w cL
coral finished stucco banc
I" x 'I" nailer attached to
level return with (2) 8d
ring shank nails with min. 1.5"
penetration into soffit framing
NTS
5/8" thick x 8"w cut
coral finished stucco bands
Finish Columns with
5/8" thick cut coral
finished stucco bands
SI.u0007 Vrl l.( pir_ai -1/ v ui
block construction finished stucco bands
REAR ELEVATION
Metal roofing and underlayment Intstalled per Product Approval
as shown on sheet I over COX decking - see roof sheeting
attachment diagram on roof plan.
5/8" thick light textured
stucco on typical concrete
block construction
FRONT ELEVATION
2" x 4" top plate 1/2" drywall ceiling on truss bottom cord
1/2" drywall on
2" x 4" studs at 16" o.c.
4" concrete slab with fibermesh OR
6 x(.410/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
base -board 2" x 4" P.T. bottom plate
Interior Non-Bearina Fartltlon
ELEVATION NOTES:
- RETURN ALL STUCCO BANDS TO WINDOW
OR DOOR.
nts
SCALE: 1/4' = 1'-0'
-1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using 8d nails. Substrate
to be 19/32" COX Plywood nailed at 6" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
12
SLOPE 14
--- 5/8" thick x 8"w cut
coral finished stucco bands
-0'-4" A.F.F.
SCALE: 1/4" = 1'-0"
PERMITTING INFORMATION (FORM 100)
2R I. 3E 2N R 2N
Florida Building Code Residential: 1TH Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Category II Wind Speed: 145 mph ultimate
Mean Roof Height: 13'-8" Roof Pitch: 4:12 11°-20°)
2E
- I 3E
Pressure Comae icient: ± 0.18
LLLLLLInternal
3E
Sub jectability to damage from: Weathering: Negligible Termites: Veru Heavu
2 2E 5
L
Width of Roof End Zone: 4'-0"
3 3E 4
Wind Exposure Classification: CLL
LL
Adjustment factor for Exposure Height Using Allowable Stress Design and
LL
LL
Load Combination per ASCE 1-10 Section 2.4 DL+LL; DL+O.4WL; 0.6DL+O.6WL
5
Exp Height Ad j Factor: 1.00 x Load Combo Factor 0.4 = 0.4 applied below
GABTC ROOFFROM
GABLE ROOF Components t Cladding Wind Pressure:
Zone: 2E +15.0/-39.0 psf
�N.
Zone: 2R. 3E +15.0/-51.0 psf
2R
Zone: 3R +15.0/-49.0 psf
I 3
2E 2E
HIP ROOF Components t Cladding Wind Pressure:
3
Zone: I +18.0/-31.0 psf
2R
Zone: 2E/3E +18.0/-41.0 psf
2EL 1.
Zone: 2R +18.0/-53.0 psf
Components t Cladding Wall End Zone Width: 3'-O"
LL 2E 5
3
WALL Components t Cladding Wind Pressure: Zone 4: + sf
p g 23.0/-25.0 p
4
Zone 5: +23.O/-31.0 psf
Components t Cladding Wind Pressure (NET) on Garage Door:
5
Zone 5: +32.0/-41.0 psf
HIP ROOF 2:12
Shear Walls Considered for Structure? Yes
To 8.12 PITCH
Continuous Load Path Provided? Yes
O = Roof Zone I
Are Components an Cladding Details Provided? Yes
Walls Zone 4
Minimum Soil Bearing Pressure: 2,500 psi, Presumptive: X By Test: psi
This Building Shall Have the Following:
p = REod ND ZONE
2E/2R
APPROVED SHUTTERS: IMPACT GLASS: X BOTH: NEITHER:
Walls Zone 5
CORNER ZONE
= Roof Zones 3/3E/3R
ROOF LIVE LOAD: 20 psf ROOF DEAD LOAD: 15 pet Attic w/out storage: 10 pet
FLOOR LIVE LOAD: 40 pat FLOOR DEAD LOAD: 1O sf Attic with storage: 20 sf
Roof Zone 2N
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
Digitally signed by
Daniel R. Braden
Date: 2021.06.10
14:53:13-04'00'
O
U �HL
O
�L z
Q < WO
-1 U
V
� U
z�
z < ,
Nl
w< C4
oc LU o 0
Ul =5 O
' Z Uj CD
00
< �' N N a' U
< 0000
F �t L <
I z Nci #
~ O Cr
� rt
aj UUJ
U
� LLI v�v �
L U lL N
fil IV a
�D '
n�co
f 10
SHEET NO:
1.
OF 5.
JoB NUMBER:
12-21 B
�. ��°° °oo
Koo °
0 gt Goo B ° aD�� %
0. o °
o Aft 97770