Loading...
HomeMy WebLinkAboutAPPROVED A Plans REV G carlton GR PR I8'-1" T.O.B. 2 " 0'-0" = Finished Floor 12 4 1 SLOPE Metal roofing and underlayment Intstalled per Product Approval as shown on sheet I over COX decking - see roof sheeting attachment diagram on roof plan. 5/8" thick x 8"w cut coral finished stucco bands LEFT ELEVATION 12 5/8" thick x 8"w cut H- coral finished stucco bands 3 5/8" thick light textured stucco on typical concrete block construction SCALE: 1/4" = 1'-0" Metal roofing and underlayment Intstalled per Product Approval as shown on sheet I over COX decking - see roof sheeting attachment diagram on roof plan. 3 thick light textured stucco on typical concrete block construction ------------------------------------------------------------- 0'-01, Finish Columns with 5/8" thick cut coral finished stucco bands Truss mfg to provide level - return to be I" short of wall Aluminum Drip Edge il Fascia 2" x 4" Sub -Fascia 12" Kaycan full o vent vinyl soffit installed per product approval form on sheet I. 12 SLOPE]4 TYPICAL SOFFIT DETAIL RIGHT ELEVATION SCALE: 1/4' = I'-O' Product Approval Submittal Affidavit Opening Schedule Swing Doors. Overhead Doors, sliding Doors. Windows t Skylights Opening NOA/FL Product Model u Manufacturer Glass Attachment method TEST Expiration Design Pressure Type NUMBER Date of Approved Tests PP 1.2.3 FLU 239.4 Single Hun g g SH-1�OOA PGT 5/16" 1/4" dia. tapcons w/ min. 1 3/8" penetration to be spaced per product approval. Contractor shall adhere to + 65.0/-80.0 PS 44 Impact min. edge distances specified in Product approval A 20-1005.08 Overhead Model 82�4/811 1e'-2' max. width p,qg note x ue to concrete blockwith i filled callwit U $5 bar vert. wing 3/8' x L' Hlti HLC Sleeve anchors at 8' o.c. th 1.25' dia. we with min. 4' edge distance. Install track to buck 3-21-22 +40.0/-44.0 PSF Garage Door g IL'-2" max height g Door C Om en rig (1) 5/IL' x 1 5/8' full thread lag xrews,n each bracket maintaining min. of 1.5' edge distance - GC to strictly adhere to product approval rovide 1/IL' u nut washer on roller afts. B FLU 15213.1 Fiberglass Smooth Plast-Pro 1/4" dia. tapcon with min 1.25" embedment at L" max from corners and 14.5" o.c. max. thereafter in jambs. +65.0/-10.0 Fiberglass C F L 4 251.�4 Sliding Glass Series -110 SGp PGT I" nom 1/4" dia. tapcons w/ min. 1 3/4" penetration to be spaced per product approval. Contractor shall adhere to + 60.0 PSF Door Type GSA min. 2 1/2" edge distances specified in Product approval - Product NOA/FL Model Manufacturer Attachment Method TEST Expiration Design Pressure 9 NUMBER Date of Approved Tests For CMU use (2) 1/4" x 2 3/4" tapcons with min 1 1/4" embedment Mullions FLU 15353.8 CM-18531 vertical mullion MI Windows and doors penetration into each Mull Clip. Attach mull to clip using (4) 410 x 1.25" self tapping screws per clip as shown in product approval. + 118.9 PSF _ Roof FLU 33818.2 5V Crim p Metal Roofing Gulf Coast Supply 2L a. 5v crimp metal roofing attached to plywood deck using #9-15 x 1.5" HWH wood screws with self sealing washer at 12" o.c. max spacing per System Roof Zone 1/2E/2R: and manufacturing g no. 5V-Type I for max pressure -94.25 pat. Install per system 1( type 2 for - q�f.25 PSF max. pressure of -131.0 psf. Fasteners shall be installed through underlag- ment and attached to/through wood sheeting attachment detail on roof ppI per plan. Plywood to be 19/32 G8X. 2N/3/3E/3R: -131.0 PSF Underla FL 208�6.1 DuPont Protec 160 DuPont Install two layers of Tyvek horizontal) in shingle style fashion using 4" and g L" overlaps. Install using I" dia. metal or plastic cap nails at 12" o.c. along P g P P g Tyvek course and end laps an a single row 24" o.c. along middle line of the field I.A.W. the product approval installation instructions. Stagger top layer using 24" to full undercourse strip parallel eave edge and cover with sheet. Overlapsuccessive sheets b 24" I.A.W. product approval installation instructiens. Siding Stucco on Block Soffit FLU 16503.1 „ 12 Tripple 4 Instal using " x T battens attached to wall using 3/I6" dia. with I" min. embedment into wall. Attach Soffit channel to wall using Full-O-Vent Sin le Kaycan LTD 0.091" dia. x 1.5" T-nails at 12" o.c. per detail C in P.A. Install J" ± 55.6 PSF SPAN VINYL S_0FFI channel to bottom of fascia using staples into soffit and same T-nails at hem and in valle s ber detail A in P.A. (roduct a royal) I have reviewed the above and approved It bg mg seal below. ( Architect or Engineer of Record ) 5/8" thick x 8"w cL coral finished stucco banc I" x 'I" nailer attached to level return with (2) 8d ring shank nails with min. 1.5" penetration into soffit framing NTS 5/8" thick x 8"w cut coral finished stucco bands Finish Columns with 5/8" thick cut coral finished stucco bands SI.u0007 Vrl l.( pir_ai -1/ v ui block construction finished stucco bands REAR ELEVATION Metal roofing and underlayment Intstalled per Product Approval as shown on sheet I over COX decking - see roof sheeting attachment diagram on roof plan. 5/8" thick light textured stucco on typical concrete block construction FRONT ELEVATION 2" x 4" top plate 1/2" drywall ceiling on truss bottom cord 1/2" drywall on 2" x 4" studs at 16" o.c. 4" concrete slab with fibermesh OR 6 x(.410/10 WWM on 6 mil Visqueen over clean compacted termite treated fill base -board 2" x 4" P.T. bottom plate Interior Non-Bearina Fartltlon ELEVATION NOTES: - RETURN ALL STUCCO BANDS TO WINDOW OR DOOR. nts SCALE: 1/4' = 1'-0' -1/8" Thick cut coral stucco over paper backed wire lath nailed to substrate through one layer of 15 lb felt using 8d nails. Substrate to be 19/32" COX Plywood nailed at 6" o.c. in field and edges with IOd ring shank galvanized nails into truss webbing. 12 SLOPE 14 --- 5/8" thick x 8"w cut coral finished stucco bands -0'-4" A.F.F. SCALE: 1/4" = 1'-0" PERMITTING INFORMATION (FORM 100) 2R I. 3E 2N R 2N Florida Building Code Residential: 1TH Edition and ASCE 1-10 for Wind Loading Building Design is: Enclosed Risk Category II Wind Speed: 145 mph ultimate Mean Roof Height: 13'-8" Roof Pitch: 4:12 11°-20°) 2E - I 3E Pressure Comae icient: ± 0.18 LLLLLLInternal 3E Sub jectability to damage from: Weathering: Negligible Termites: Veru Heavu 2 2E 5 L Width of Roof End Zone: 4'-0" 3 3E 4 Wind Exposure Classification: CLL LL Adjustment factor for Exposure Height Using Allowable Stress Design and LL LL Load Combination per ASCE 1-10 Section 2.4 DL+LL; DL+O.4WL; 0.6DL+O.6WL 5 Exp Height Ad j Factor: 1.00 x Load Combo Factor 0.4 = 0.4 applied below GABTC ROOFFROM GABLE ROOF Components t Cladding Wind Pressure: Zone: 2E +15.0/-39.0 psf �N. Zone: 2R. 3E +15.0/-51.0 psf 2R Zone: 3R +15.0/-49.0 psf I 3 2E 2E HIP ROOF Components t Cladding Wind Pressure: 3 Zone: I +18.0/-31.0 psf 2R Zone: 2E/3E +18.0/-41.0 psf 2EL 1. Zone: 2R +18.0/-53.0 psf Components t Cladding Wall End Zone Width: 3'-O" LL 2E 5 3 WALL Components t Cladding Wind Pressure: Zone 4: + sf p g 23.0/-25.0 p 4 Zone 5: +23.O/-31.0 psf Components t Cladding Wind Pressure (NET) on Garage Door: 5 Zone 5: +32.0/-41.0 psf HIP ROOF 2:12 Shear Walls Considered for Structure? Yes To 8.12 PITCH Continuous Load Path Provided? Yes O = Roof Zone I Are Components an Cladding Details Provided? Yes Walls Zone 4 Minimum Soil Bearing Pressure: 2,500 psi, Presumptive: X By Test: psi This Building Shall Have the Following: p = REod ND ZONE 2E/2R APPROVED SHUTTERS: IMPACT GLASS: X BOTH: NEITHER: Walls Zone 5 CORNER ZONE = Roof Zones 3/3E/3R ROOF LIVE LOAD: 20 psf ROOF DEAD LOAD: 15 pet Attic w/out storage: 10 pet FLOOR LIVE LOAD: 40 pat FLOOR DEAD LOAD: 1O sf Attic with storage: 20 sf Roof Zone 2N ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP. AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE Digitally signed by Daniel R. Braden Date: 2021.06.10 14:53:13-04'00' O U �HL O �L z Q < WO -1 U V � U z� z < , Nl w< C4 oc LU o 0 Ul =5 O ' Z Uj CD 00 < �' N N a' U < 0000 F �t L < I z Nci # ~ O Cr � rt aj UUJ U � LLI v�v � L U lL N fil IV a �D ' n�co f 10 SHEET NO: 1. OF 5. JoB NUMBER: 12-21 B �. ��°° °oo Koo ° 0 gt Goo B ° aD�� % 0. o ° o Aft 97770