Loading...
HomeMy WebLinkAboutAPPROVED M ENERGY CALCS & MANUAL J - 50 HUARTEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: 5 0 ,1 � Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, ` \ Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 } 1. New construction or existing New (From Plans) % Wall Type�1442.0 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int. Insui, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c_ NIA R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 11. Ceiling Types (1476.0 sgft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade (ft2) 1446 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 7. Windows(141.3 sgft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 175 a. U-Factor. Sgl, U=1.04 101.25 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 13. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. 14. Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.284 a. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor.(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 50 gallons 9. Floor Types (1445.5 sgfL) Insulation Area EF:0,970 a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features b. NIA R= ft2 None c. NIA R= ft2 16. Credits None Total Proposed Modified Loads: 44.57 Glass/Floor Area: 0.098 PASS Jr� Total Baseline Loads: 45.19 1 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code - PR EPAR DJY'��* Before construction is completed ;Q DATE: this this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. , with the Florida Energy! �'{y OWNER/G`F�VT BUILDING OFFICIAL: DATE: ''11�� ��\ 1 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp IM Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft' _ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft- __- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' _ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' ___ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 fI2 _ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' ___ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft- _ 0 1 0 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft- _ 0 1 0 9SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' - 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft- 240 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC V# Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft- N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 IF 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft- 0.1 Wood 6 Under Attic (Vented) BEDROOM 30 Blown 204 ft- 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488ft2 .1 Wood 10 Knee Wall (Vented) GREAT/DINING 19 Blown 30 ft' 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 NE=>SW Exterior Concrete Block - IM InsuBEDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 _.2 SW=>NE Exterior Concrete Block- Int InsuBEDROOM 4.1 28 0 8 0 224.0 IF 0 0 0.4 0 3 NW=>SE Exterior Concrete Block - Int InsrBEDR00M 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 _ 5 NE=>SW Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 6 NE=>SW Exterior Concrete Block - Int InsBIEDROOM 2 4.1 16 0 8 0 128.0 ft- 0 0 0.4 0 _ 7 SE=>NW Exterior Concrete Block - Int Ins8EDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 _ 8 S=>N Exterior Concrete Block - Int InsBEDROOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.4 0 _ 9 SW=>NE Exterior Concrete Block - Int Ins®EDROOM 2 4.1 2 0 8 0 16.0 ft- 0 0 0.4 0 _10 SE=>NW Exterior Concrete Block- Int Insul ENTRY 4.1 6 0 8 0 48.0 IF 0 0 0.4 0 11 SW=>NE Exterior Concrete Block - Int Insul ENTRY 4.1 1 0 8 0 8.0 IF 0 0 0.4 0 12 SW=>NE Exterior Concrete Block - Int InsuLAUNDRY 4.1 6 0 8 0 48.0 ft- 0 0 0.4 0 _13 NE=>SW Exterior Concrete Block- Int Ins6REAT/DINI 4.1 26 0 8 0 208.0 ft' 0 0 0.4 0 14 NW=>SE Exterior Concrete Block - Int InstOREAT/DINI 4.1 20 0 8 0 160.0 ft- 0 0 0.4 0 1/12/2021 12:02 PM ErergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft- 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6ft WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. Wall V # Omt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 1.04 0.29 Y 32.9 ft- 1 It 0 in 1 It 5 in Drapes/blinds 1.04 0.29 Y 6.9 ft- 1 It 0 in 1 ft 5 in None 1.04 0.29 Y 24.0 it= 6 It 0 in 1 It 5 in None 1.04 0.29 Y 37.5 T 1 ft 0 in 1 ft 5 in None 1.11 0.27 Y 40.01? 8 ft 0 in 1 ft 5 in Drapestblinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.04 139.01 .1263 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys41 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kBtuthr ofm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPM Conservation _ 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None 1 /12/2021 12:02 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply — — Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 175 ft- Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablee Ceiling Fans: ]Thermosta[[t:]]N Heating H Jan [XI Feb rx�]' Mar ] E ] E J �Cl [ ] Jun [X] [ ]Jul Aug [JC] [) Sep [ ] L 1 Doc rD(,� Dec Venting [[ 11 Jan [[ II Feb [Jg Mar tXl [x) Apr [) May [ 1 Jun [ 1 Jul Aug [ 1 Sep lxl Occtt X Nov [ j Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) 78 78 78 78 78 78 78 78 PAM M 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) 68 PM 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 It 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 It 0.3 WIC Default(8 lbs/sq.ft. ft2 It 0.3 M. BATH Default(8 lbs/sq.ft. ft2 It 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Defauft(8 lbs/sq.ft. ft2 it 0.3 ENTRY Defauft(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default 8 Itu/s .ft. ft2 ft 0.3 GREAT/DINING 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: x Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w Design Location: FL, Fort Pierce S � COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be with alignedThe insulation in any dropped ceiling/ soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind noni ( i and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box oi The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids an frm sprinkler cover PlAtes and wells or milinns ,., ,,vy mans >uan ue m aworaarnz corm ure provisions of iC ;-4uo. 1/12/2021 12:02 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Sgl, U=1.04 SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 SHGC: SHGC=0.27 c. U-Factor. WA SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-FactogAVG): N/A SHGC(AVG): WA FT. PIERCE, FL, New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft- 1 c. N/A R= fts 2 d. N/A R= ft2 Yes 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft2 1446 b. Knee Wall (Vented) R=19.0 30.00 ft2 Area c. N/A R= ft2 101.25 1`12 12. Ducts, location & insulation level R ft2 a. Sup: Attic. Rat Attic, AH: Attic 6 175 40.00 ft2 13. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 34.8 SEER:15.00 fP 3.832 ft. 0.284 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. N/A R= ft2 c. N/A R= ft2 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card Will be completed based on installed Code compliant features. _ Builder Signature: -- Date: ��- Address of New Home: y/FL Zip: kBtu/hr Efficiency 34.8 HSPF:8.50 Cap: 50 gallons EF: 0.97 None *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 - wrightsoft® Project Summary o ta, Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Kum 772-466-6799 Fa c 772466-6796 Email: OUICKC4LCS@AOL.COM For. WYNNE DEVELOPMENT CARLTON III, FT. PIERCE, FL Notes: So 0"C D- Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19691 Btuh Structure 16785 Btuh Ducts 5900 Btuh Duds 8919 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 25591 Btuh Use manufacturers data n Rate/swing multiplier Equipment 0.95 Infiltration sensible load 24418 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2065 Btuh Ducts 2429 Btuh Central vent (0 cfm) 0 Btuh Heatingg Area Cool' In (none) (T) 1602 1602 Equipment latent load 4493 Btuh Volume (ft') 14827 14827 Airchanges/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 28912 Bluh EquivAVF(crm) 94 49 Req.total capacity at0.70SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536XO30 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 34 OF 8.5 HSPF 34600 Btuh@47-F 27 OF 1160 Dim 0.045 cfm/Btuh 0 in H2O Backup: Input=7kW, Output= 23009 Btuh, 100 AFUE Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536XO30 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Sensiblecooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow, 1160 cfin Airflow factor 0.045 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.35 Calculations approved byACCAto meet all requirements of Manual J 8th Ed w�ighZsoft- 2C21-Jan1212A496 ,em Ri911-SuL@Urrversa1201919.021 RS1.08101 Pagel ...rfs1WrigrtvoRHVACIWYNNE-THE GRAND CARLTONnp Calc=MIB Frord Doorfiems: N wrighttsoft Right-M Worksheet Jab: Entire House per QUICK CALCS, INC. By. 317 ST. LUCIE LN., FLPIERCE, FL 34946 P1ore:772-465-6799 Faz T2466.6796 Emil: OUICKCALCS@40L.COM 1 Room name Entre House BEDROOM 2 EVosedmdl 1762 ft + 41.0 ft 3 Room height 93 It d 8A ft heaVcoN 4 Room dimensions 14.0 x 18.0 It I 5 Room area 16015 ff 252.0 fF Ty Construction U-value Or HTM Area (ft') Load Area Load number (BWh4P2F) (BtuhRF) or perimeter (ft) (BWh) I or perimeter (ft) (BWh) Heat Cool Gross NFP/S Heat Cool Gross NIP/S Heat Cool 6 VI/ 13A4o s 0.143 ne 4.00 255 551 513 2055 1306 72 72 288 183 _G tActom 1270 ne 3556 70.43 38 0 1344 2662 0 0 0 0 13A4ocs 0.143 se 4.00 2.55 128 87 348 221 0 0 0 0 1Aclom 1270 se 35.56 70.95 20 0 711 1419 0 0 0 0 11 11DO 0.390 se 10.92 11.31 21 21 229 238 0 0 0 0 w 13A-0as 0.143 s 4.00 2.55 34 34 136 86 0 0 0 0 13A4ocs 0.143 six 4.00 2.55 416 390 1562 993 144 144 577 367 1Ac1cm 1270 sw 3556 70.95 6 0 213 426 0 0 0 0 1Aclom 1270 sv 35.5E 70.95 20 0 711 1419 0 0 0 0 13A4as 0.143 nw 4.00 2.55 352 288 1151 732 112 88 354 225 1Ac1cm 1270 nw 3556 4524 12 0 415 528 12 0 415 528 IA-cicm 1270 nw 355E 4524 12 0 427 543 12 0 427 543 4A5.2omd 0.770 nw 2156 36.90 41 0 880 1505 0 0 0 0 P 12(3-0sw 0.091 2.56 128 120 120 306 164 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 1602 1602 1435 3715 252 252 226 585 F 22A-ml 0.989 - 27.69 0.00 16112 176 41178 0 252 41 1135 0 6 c)AEDe=rsion 2: 197 Envelope loss/gain 16802 1597C 3421 2627 12 a) Infiltration 2890 815 640 180 b) Roomventilation 0 0 0 0 13 internal gains: O=pants@ 230 0 1 0 0 0 Appliancesrbther 0 0 Subtrrtal(lines6to 13) 19691 16785 4061 2807 LessWarnalload 0 0 0 0 Lesstransfer 0 0 0 0 Radistribufion 0 0 0 0 74 Subtotal 19691 16785 4061 2807 15 Dud loads 30% 63% 5900 8919 30% 53% 1217 1491 Total room load 25591 25704 1 5278 4298 Airrequired (c1m) 1160 1160 239 194 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrigFstsoTt* 2021-.kM212.04:36 RigkSute®UriwmI 201919.021 RSU08101 .4r ...rtAWdg[Roft HVAMWYNNE-THE GRAND CARLMl 70N.rup Calc=8 Fror0.Doorfares: N Page 1 writsoft Right-J® Worksheet 'Oa Entire House Date: QUICK CALCS, INC. BY 317STLUC4ELN.,Fr.PIERCE,FL34946Phora:772-466-6799Fax772-46"796 EMi1:QU1G(CALCS@ADL.COM 1 Room name WIC NNSTER BATH 2 E*�pOsedwall 0 it 170 it 3 Room height 80 It healkool 8.0 It heattool 4 Roomdimensons 70 x 90 ft 70 x 17D It 5 Roorr m 63.0 iF 119.0 fl' Ty CortMdon U-1 Iue Or HTM Area Load number (Bblh@z'F) (Btuh4n or perimeter (to (Bluh) or perimeter (ft) (BWh) Hea[ Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 Y--G1ACIom 13AAors 0.143 ne 4AD 210 0 0 0 0 0 - 0 0 0 1270 ne 3556 70.43 0 0 0 0 0 0 0 0 V+/ 13A-4= 0.143 se 4A0 2.55 0 0 0 0 0 0 0 0 L� DC 1At1an 12M w 3556 70.95 0 0 0 0 0 0 0 0 11 11DO 0390 se 1092 1131 0 0 0 0 0 0 0 0 w 13AA= 0.143 s 4.00 255 0 0 0 0 0 0 0 0 yl 13A-0as 0.143 w4A0 255 0 0 0 0 136 130 521 331 {L—fG 1Aciom 12M w 3556 70.95 0 0 0 0 6 0 213 425 1Aclom 12M sw 3556 70.95 0 0 0 0 0 0 0 0 13A-4= - Q143 rw 4A0 2.55 0 0 0 0 0 0 - 0 0 1Ac1om 1270 nw 3556 4524 0 0 0 0 0 0 - 0 0 1Ac1on 1270 my 3556 4524 0 0 0 0 0 0 - '. 0 0 4A5-2omd 0.770 rw 2156 36M 0 0 0 0 0 0 0 0 P 12C-Ow OA91 2.55 120 0 0 0 0 0 0 0 0 C 16A-30md OA32 - 090 232 63 63 56 146 119 119 - 107 276 F 22A4p1 0989 - 27.69 0.00 63 0 0 i 0 119 17 471 0 6 o)Amex w -13 55 Ernebpelosslgain 56 133 1311 1087 12 a) IMtlbaton 0 0 265 75 b) Rocmwntilation 0 0 0 0 13 hiamal gains: Oovpanb@ 230 0 0 0 0 Applianceslotl 0 0 SubbW(lines6ta13) 56 133 1577 1162 LesseAemalload 0 0 0 0 LesstansLr 0 0 0 0 RedWbtAon 0 0 0 0 14 Subtotal 56 133 15" 1162 15 Durtloads 30% 539/6 17 71 30%1 53% 472 618 ToW room bad 73 204 2049 7780 Air required(dm) 3 9 93 80 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2021JarF12120436 AM E GRA DCARLONnp 1919.021B FrortD1 Paget ..,rOiWrighSoft HVAG\WYNNE-TILE GRANDG4RLTONnp GaIc=NUB Fror¢Ooorfaoes: N wdghtsoft RighWO Worksheet Job. Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN.,FT.PIERCE, FL 34946 Plow 772-466-6799 Fax: 772466-6796 Email: OUICKCALCS@(JOL.COM 1 Room name K-FCHEN BATH 2 EVosadwall 0 a 5.0 tt 3 Room height 8.0 It heel/cool 9.4 ft heaVmol 4 Room dimensors 1.0 x 192D ft 9.0 x 5.0 ft 5 Roomarea 192.0 ft= 45.0 IF Ty Construction U-value Or HTM Area (� Load Area (� Load number (BNW2F) fth4F) or perimeter It) (Btuh) or perimeter (ft) (BNh) Heat Cool Gross N/P/S Heat Cool Gras WP/S Heat Cool 6 Vy 13A-0ar 0.143 ne 4.00 2S5 0 0 0 0 47 47 188 120 �G to-dw 1270 ne 3556 70.43 0 0 0 0 0 0 0 0 VL 13A400s 0.143 se 4.00 2.65 0 0 01 0 0 0 0 0 1Acicm 1270 se 3556 70.95 0 0 01 0 0 0 0 0 11 11DO 0.390 s 10.92 11.31 0 0 0 0 0 0 0 0 w 13A4ors 0.143 s 4.00 2.55 0 0 OI 0 0 0 0 0 VII 13AAors 0.143 sw 4.00 2.55 0 0 OII 0 0 0 0 0 1Aclom 1270 sw 3556 70.95 0 0 0 0 0 0 0 0 I�-GG tAclorn 1270 sw 3556 70.95 0 0 Oi 0 0 0 0 0 134-0ors 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 1Aclom 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 4AS2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P 12C-Ow 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 0.90 2,32 192 192 172 445 45 45 40 104 F 22A-tr>I 0.989 - 27.69 0.00 192 0 I 0 0 45 5 138 0 6 c)AMe=rsion -39 Envelope loss/gain 172 406 367 202 12 a) Infiltrafion 0 0 92 26 b) Room ventilation 0 0 0 0 13 Intemal gain Oocupanls@ 230 0 0 0 0 ApplianceVother p 0 Subtotal(lines6to 13) 172 406 459 228 Lesexdemal load 0 0 0 0 Lestrarder OI 0 0 0 Redistribution I I 14 SubIl161 1721 459 228 15 Duct loads 30% 53% 52 216 216 30% 53% 137 121 Tot3I room load 224 622 596 349 Airrequired(dm) 10 28 27 16 Calculations approved byACCAto meet all reauirements of Manual J 8th Ed 2021Jarvl 212.0436 RigI SuteO Uriversl 201919.021 RSU08101 Page 3 ...rislWrigllsoft HVADWYNNE-THE GRAND CARLTON.np Caic=MJ8 Frord Doorfaces: N t wrightsofr Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. ay. 317 ST. LUCIE LN., FT.PIERCE, FL 34946 PhDre: 772.466-6799 Fax T72466-6795 Email: OUICKCALCS@40LCOM 1 Room name BEDROOM2 ENTRY 2 Elposd wall 302 It 6.0 It 3 Room height 8.0 ft hea%col 8.0 ft heaVcool 4 Room dimensions 1.0 x 1905 ft 6.0 x 10.0 ft 5 Room area 190.5 a, 60.0 fF Ty Construction U-value Or HTM Area (fly Load rea A(ftF) Load number (BalhFK-'F) (BWhAf� or perimeter (t) (BWh) or perimeter (ft) (Bll Heat Cool Gross N/P/S Heat Cool Gros NANS Heat Cool 6 t 1344ors 0.143 ne 4.00 2.55 120 120 480I 305 0 0 0 0 —G 1AtNom 1270 ne 3556 70.43 0 0 0 0 0 0 0 0 13A-0as 0.143 re 4.00 255 80 60 240 153 48 27 108 69 1Ac1cm 1270 se 3556 70.95 20 0 711 1419 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 01 0 21 21 229 238 W 13A-4= 0.143 s 4.00 2.55 34 34 136! 86 0 0 0 0 v+/ 13A4o s 0.143 w 4.00 2.55 8 8 32 20 0 0 0 0 IA-dw 1270 sv 35.56 7095 0 0 0 0 0 0 0 0 1Aclom 1270 w 3556 70.95 0 0 0 0 0 0 0 0 13A4o s 0.143 nw 4.00 255 0 0 0 0 0 0 0 0 1Ao1= 1270 nw 3556 4524 0 0 0 0 0 0 0 0 1Aclom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 4A5.2omd 0.770 nw 2156 36.90 0 0 0 0 0 0 0 0 P 12C-Ow 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 0.90 2,32 191 191 171 442 60 60 54 139 F 2MADI 0.989 - 27.69 0.00 191 30 835 0 60 6 166 0 6 c)AED exarrsim 209 41 Envelope losstgain 2606 2635 557 4D4 12 a) Infiltration 472 133 94 26 b) Roomventlafion 0 0 0 0 13 Intemalgaim Oaupants@ 230 0 I 0 0 0 Applianoesrolher 0 0 Sublotal (lines 6 to 13) 3078 2768 651 430 LessexL-malload 0 0 0 0 Lestansfer 0 0 0 0 Redistribution i 0 0 0 0 14 Subtotal 3078 2768 651 430 15 Durtloads 30% 53%1 922 1471 30% 53A 195 229 Total room load 4000 4239 846 659 Air required (dm) 181 191 38 30 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed 2021-Jarv121294:36 Rigit-Sute®Uriversai 201919.021 RSU08101 ...rlslWdgrisoft HJACrWVNNE-THE GRAND CARLTON.np Calc=MB Fror Doorfaces: N Pa9 eta wrightSOW RightJ@ Worksheet Job: Entire House Dom; QUICK CALCS, INC. By. 317 ST LUCIE LN.,Fr.. PIERCE, FL 34946 Phore: 772-466-6799 Fas 772-4666796 Email: OUICKCALCS@AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 Exposed wall 6.0 It 46.0 ft 3 Room height 8.0 ft heatlwol 1 12.0 ft heat6wal 4 Room dimensons 7.0 x 6.0 it 1.0 x 488.0 It5 Room area 42.0 1F 488.0 11 Ty Construction U-value Or HTM Area (ft') Load F Area (ft') Load number (BtuW--'F) (BWhMF) or perimeter (ft) (B1uh) or perimeter (R) (BWh) Hea[ Cool Gras; N/PIS Heat Cool Gross NIP/S Heat Cool 6 Yrl 13A-4= 0.143 ne 4.00 2.55 0 0 0 0 312 274 1098 698 _G 1Ac1om 1270 ne 35.56 70.43 0 0 0 0 38 0 1344 2662 13A-0as 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 se 35.56 70.95 0 01 0 0 0 0 0 0 11 11DO 0.390 s 10.92 11.31 0 01 0 0 0 0 0 0 w 13A,4= 0.143 s 4.00 2,55 0 0 0 0 0 0 0 0 13A4= 0.143 w 4.00 2,55 48 46 192 122 0 0 0 0 1A lom 1270 sw 35.56 70.95 0 0 0 0 0 0 0 0 1Attom 1270 sw 35.56 70.95 0 0 0 0 0 0 0 0 13A4ors 0.143 rw 4.00 2.55 0 0 0 0 240 199 798 507 1Ac1om 1270 nw 3556 4524 0 0 0 0 0 0 0 0 1A-dwn 1270 nw 3556 4524 0 0 0 0 0 0 0 0 4A5.2cmd 0.770 nw 2156 36.90 0 0 0 0 41 0 880 1505 P 12C-0sw 0.091 2.55 128 0 0 0 0 0 0 0 0 C 16A60md 0.032 - 0.90 2.32 42 42 38 97 488 488 437 1132 F 22A-ml 0.%9 - 27.69 0.00 42 6 166 0 4811 46 1274 0 6 c)AEDe=rson -22 -597 Envelope loWgain 396 198 5830 5908 12 a) Infiltration 94 26 1077 304 b) Roomventilation 0 0 0 0 13 Internal gains: O=pant@ 230 0 0 0 0 Applianoesbther f 0 0 Sublotal(lines6 to 13) 490 224 6907 6212 Lesextamal load 01 0 1 0 0 Lesfransfer 0 0 0 0 RediWbutian 0 0 0 0 14 Subtotal 490 224 6907 6212 15 Ductloads 30% 539/6 147 119 30% 53% 2070 3301 Total room load 636 344 1 8977 9512 Air required(dm) 29 16 407 429 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed wVssft�o 2021-JarF1212:04:36 .9CfA -^ Riga-SUL@Uriv rml20l9l9.02I RSU08W1 Pages ...r,,\W,dghlsot HVAQWYNNE-THE GRAND CARLTDN.np Calc=M76 Frorli DoOffams: V 1 wrightsoft' RighW@ Worksheet Jcb. Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone: 772-466.6799 FaK 772<66£796 Email: QUICKC4LCS@pOLCOM 1 Room name BEDROOM3 2 Bposedwall 25.0 It 3 Room height 8.0 It heat/cool 4 Room dimensions 15.0 x 10.0 ft 5 Room area 150.0 ft' Ty Construction U-value Or HTM Area (IF) Load Area Load number (BWhdft -Fj (BWh/M or perimeter(ft) (BNh) ' or perimeter Heat Cool Gross NIPS Heat Cool Gross NP5 Heat Cool 6 W 13A4ocs 0.143 ne 4.00 2S5 0 0 0 0 �C IA-clom 1270 ne 35.56 70.43 0 0 0 0 13A-0acs 0.143 se 4.00 2S5 0 0 0 0 1Aclon 1270 se 3556 70.95 0 0 0 0 11 11DO 0.390 se 1092 11.31 0 0 0 0 w 13A4o s 0.143 s 4.00 2.65 0 00 0 13A4ocs 0.143 sw 4.00 2.55 80 60I 240 153 1Actom 1270 sw 3556 70.95 0 0 00 1Ac1cm 1344ocs 1270 0.143 sw nw 35.56 4.00 7095 2.55 20 0 a 0 711 0 1419 0 1Aclom 1270 nw 3556 4524 0 0 0 0 IA-ctom 1270 nw 35.56 4524 0 0 0 0 4A5-2omd 0.770 nw 2156 3690 0 0 0 0 P 12C-O w 0.091 - 2.55 128 120 120 306 154 C 16A-30md 0.032 - 0.90 2.32 150 150 134 348 F 22A-tpl 0.989 27.69 0.00 150 25 692 0 6 c)AEDexnlcson 296 Envelope losscgain 0084 2369 12 a) Irfilhadon 156 44 b) Rcomvendlation 0 0 13 Internal gains: O—parl 230 0 0 Applie rosslother 0 SubWal(linestito13) 2240 2413 Le Vernal load 0 0 I-MlIansfer 0 0 Redistribution 0 0 14 Sublotal 2240 2413I 15 Ductloads 30% 533/6 671 12821 Total room load 2911 3695 Airrequired (Cm) 132 167 Calculations approved byACCAto meet all reeuirements of Manual J 8th Ed 'PW wWxgft soTC� 202EJar-121204:36 �`A Rigtt-SLiL@Uriwe 1201919.021RSU08101 Page ...rts\Wngtboft HVAMWYNNE-THE GRAND CARL7ONncp Clc=MJ8 Fronk Doorfaoas:N