HomeMy WebLinkAboutAPPROVED Carports Anywhere - W Timmerman - 302012 - Digital Sealed1
-0" 2'-0"8'-0"
a on
! on
—12'-0"
IN
ROLL-UP
----------------------------DOER---
SWINGING 0I
DOOR
I
Ln
1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM,
COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT
LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, FINISH FLOOR ELEVATION
AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS.
2. THIS STRUCTURE IS DESIGNED AS A NON —HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1)
CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS.
IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER
COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST, AND NOT PROVIDED AND INSTALLED
BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT
THE OWNER'S RISK. CARPORTS ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE
FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS.
3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2.
4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM
Al003/A1003M-15.
5.PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, AND/OR OTHER LOCAL CODE
REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER.
6. ROOF AND WALL SHEATHING SECURED WITH #12-14x3/4" SELF —DRILLING SCREWS WITH SEAL
WASHERS ® 6" O.C. MAX.
7. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF —DRILLING SCREWS.
8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DONE IN
SHOP BY A CERTIFIED WELDER.
9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,500LB TENSILE STRENGTH.
10. 14GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL.
4"x54" EXPANSION ANCHOR WITHIN 6"
OF EACH POST/TRUSS ALONG SIDES —
AND EVERY OTHER END —WALL POST
2" MIN.—IVABASE RAIL
_-III-II °
w 2,500 PSI 4" CONCRETE
SLAB WITH 10GA. W.W.F.
I
2" OR FIBER MESH
I-1
MINIMUM SOIL BEARING CON INUOUS WITH MINIMUM
CAPACITY 500 PSF(TYP.) 25" OVERLAP SPLICE
CONCRETE FOUNDATION/BASE RAIL
ANCHOR DETAIL
2 5" PLAN VIEW DOOR FRAMING
1 if" RECESS
4 --DOOR WIDTI '
ELEVATION VIEW
DOOR FRAMING
" RECESS
.75"T 1 4,> DOOR WIDTH
OPTIONAL ROLL -UP DOOR
CONCRETE SPLASH -GUARD RECESS
ROLL -UP
-------------------- DMFt----------------
-I SWINGING
DOOR
r_I(0
r
I
LO
NOTES:
SUB —GRADE SOILS:
—TO BE TERMITE TREATED AND COVERED WITH 6 MIL
VAPOR RETARDANT PER SECTION R318 AND 1816
OF THE 2020 FLORIDA BUILDING CODE, 7TH EDITION
—BOTTOM OF CONCRETE FOOTING SHALL BE MINIMUM
OF 12"BELOW UNDISTURBED OR ENGINEERED GRADE
CONCRETE:
—MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28
DAYS
—ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE
PROPOSED STRUCTURE SHALL BE DESIGNED TO
SLOPE AWAY FROM THE STRUCTURE
REINFORCING STEEL (REBAR) REQUIREMENTS:
—MINIMUM GRADE 40 STEEL
—REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED:
—THE REBAR IS BENT COLD
—THE DIAMETER OF THE BEND MEASURED ON
THE INSIDE DOES NOT EXCEED 6—BAR DIAMETERS:
AND
—REINFORCEMENT PARTIALLY EMBEDDED IN
CONCRETE SHALL NOT BE FIELD BENT EXCEPT
IN CASES WHERE DOWELS NEED TO BE BENT TO
ALIGN WITH A VERTICAL CELL. THESE REBAR
MAY BE BENT NOT TO EXCEED TO SLOPE OF 1"
HORIZONTALLY TO 6" VERTICALLY.
—COVER:
—3" COVER MINIMUM WHERE THE CONCRETE IS
CAST AGAINST AND PERMANENTLY IN CONTACT
WITH SOIL OR WEATHER, AND 11" ELSEWHERE.
REBAR EMBEDDED IN GROUTED CELLS SHALL
HAVE A MINIMUM CLEAR DISTANCE OF }" FOR
FINE GROUT, AND 4" FOR COARSE GROUT
BETWEEN REBAR AND ANY FACE OF A CELL.
REBAR USED IN MASONRY WALLS SHALL HAVE A
MASONRY COVER (INCLUDING GROUT) OF NOT
LESS THAN 2" FOR MASONRY UNITS WITH FACE
EXPOSED TO EARTH OR WEATHER, AND 11" FOR
MASONRY UNITS NOT EXPOSED TO EARTH OR
WEATHER.
GALVANIZATION:
—METAL ACCESSORIES FOR USE IN EXTERIOR WALL
CONSTRUCTION AND NOT DIRECTLY EXPOSED TO
WEATHER SHALL BE GALVANIZED IN ACCORDANCE
WITH ASTM A 153, CLASS B-2. METAL PLATE
CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED
DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL
OR HOT DIPPED GALVANIZED.
1 1 ■ 6 , r
CODE VERSION
FBC 2020 7th Edition,
ASCE-7-16
MANUFACTURER
CARPORTS ANYWHERE
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II-B
RISK CATEGORY
I
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
UTILITY, U
WIND SPEED
Vult-160mph
EXPOSURE
B
ENCLOSURE
ENCLOSED/OPEN
INTERNAL PRESSURE COEFF.
+/— 0.18/0.0
IMPORTANCE FACTOR
1.0
ROOF DEAD LOAD
1OPSF
ROOF LIVE LOAD
20PSF OR 3001b P.L.
FLOOR DEAD LOAD
10PSF
FLOOR LIVE LOAD
50PSF
"R"RATING OF WALLS, FLOOR, ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
1,320 SQ. FT.
REVISIONS
RFVI
DESCRIPTON
I DATE
I BY
MTB
4/21/21
S Indian River Dr, Jensen Beach
30'L X 44'W X 12'H
T 11
�,q
EN
NO.
NO. 64608 i 2
i 'n
STATE OF t•441
��iC�'••
FLORIDP '����
�/S/ONA��-4 �``
,
�
NNN
�//11111111��
Digitally signed
by Matthew
MIN. 2,500 PSI 4" CONCRETE SLAB WITH 10GA. W.W.F. (OR 3: Baldwin
FIBER MESH) AND 12"x12" REINFORCED FOOTER PERIMETER 12"x12" REINFORCED FOOTER
-------------------------------- R1L11 O-P---------------------------------------------------------------------------------------------------------------------------------- --------T -----ROI I =JJP-------------------------- ---- 1 Date: 2021.04.21
DOOR FRONT DOOR �
W 17.03.41-04'00'
3'-0" 8'-0"-11'-0' 20'-0" OPEN1'-0f' -0" '
z Matthew T. Baldwin P.E.
Florida License #64608
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND w Q
THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES Sheet: CA-1 OF 4
I
d
ROLL —UP
DOOR
mr
12
3'-112 3'-1
FRONT/REAR END WALL
SWINGING
DOOR
—3'-0"-
V-4"
LEFT/RIGHT(MIRRORED) SIDE WALL
CAR KM "
CODE INFOR ATION
CODE VERSION FBC 2020 7th Edition,
ASCE-7-16
MANUFACTURER CARPORTS ANYWHERE
BUILDING TYPE UTILITY STRUCTURE
CONSTRUCTION TYPE II-B
RISK CATEGORY I
FIRE PROTECTION NONE
ROLL —UP = FIRE SUPPRESSION SYSTEM NONE
DOOR of
OCCUPANCY UTILITY, U
w WIND SPEED Vult-160mph
J EXPOSURE B
ENCLOSURE ENCLOSED/OPEN
INTERNAL PRESSURE COEFF. +/— 0.18/0.0
IMPORTANCE FACTOR 1.0
3'-0" ROOF DEAD LOAD 10PSF
ROOF LIVE LOAD OPSF OR 3001b P.L.
} FLOOR DEAD LOAD 10PSF
-9`" FLOOR LIVE LOAD 50PSF
12'-0"
"R"RATING OF WALLS, FLOOR, ROOF N/A
MODULES PER BUILDING 1
HURRICANE PROTECTION USAGE NO
HURRICANE SHELTER USAGE NO
SQUARE FOOTAGE 1,320 SQ._FT.
REVISIONS
IREVI DESCRIPTON DATE BY
MTB
4/21/21
S Indian River Dr, Jensen Beach
301 X 44'W X 12'H
_W
C�
Z
Q
O.C. MAX.
0
Z
W
Matthew T. Baldwin P.E.
LEFT/RIGHT SIDE LEAN-TO WALL
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND w Florida License #64608
THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES Cn rShet: CA-2 OF 4
c�
w
J
0
1
2'
w
J
0
CD
J
O
FRONT/REAR END WALL
SWINGING
DOOR
30'-0"
LEFT/RIGHT(MIRRORED) SIDE WALL
=
w
x
U
w
0
CODE VERSION
`BC 2020 7th Edition,
ASCE-7-16
MANUFACTURER
CARPORTS ANYWHERE
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II—B
RISK CATEGORY
I
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
UTILITY, U
WIND SPEED
Vult-160mph
EXPOSURE
B
ENCLOSURE
ENCLOSED/OPEN
INTERNAL PRESSURE COEFF.
+/— 0.18/0.0
IMPORTANCE FACTOR
1.0
ROOF DEAD LOAD
1OPSF
ROOF LIVE LOAD
20PSF OR 3001b P.L.
FLOOR DEAD LOAD
1OPSF
FLOOR LIVE LOAD
50PSF
"R"RATING OF WALLS,FLOOR,ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
INO
SQUARE FOOTAGE
11,320 SQ. FT.
REVISIONS
RT
DESCRIPTON
DATE
I BY
w_
Z
W
30'-01,
w
LEFT/RIGHT SIDE LEAN-TO WALL PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND w
THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES (/) rSh,,t--
MTB
4/21/21
S Indian River Dr, Jensen Beach
30'L X 44'W X 12'H
Matthew T. Baldwin P.E.
Florida License #64608
CA-3 OF 4
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
(4)#12-14xj" SELF -DRILLING
SCREWS
NIPPLE TO
\BASE RAIL NIPPLE
BASE F
POST TO BASE RAIL
CONNECTION
2"x2"x2" 16 GA.
ANGLE CLIP
SECURED WITH (4)
#12-14xi"
SELF -DRILLING
SCREWS
NON-STRUCTURAL
HEADER OR WINDOW
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
(4)#12-14xi" SELF -DRILLING
SCREWS
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14xj"
SELF -DRILLING SCREWS
END POST TO BASE RAIL
CONNECTION
2"x2"x2" 16 GA. ANGLE CLIP SECURED
WITH (4) #12-14xi" SELF -DRILLING
SCREWS
-VARIES N
1.1 1.1 TO l
MAX. SPACIN
r3" MIN.
STD. MAX. SP*CING
VARIES
> SIDE WALL ROLL -UP
DOOR/FRAME OUT
HEADER DETAIL
It
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14xj"
SELF -DRILLING SCREWS
INTERMEDIATE POST TO
HEADER/BASE RAIL/OR
WINDOW RAIL DETAIL
MINIMUM 6" TS
NIPPLE. NIPPLE
SECURED TO WALL
POST WITH
(4)#12-14xi"
SELF -DRILLING
SCREWS
POST TO TRUSS
CONNECTION
NST LL PER NUF CTURERS INSTRUCTIONS 26 GAUGE ROOF SHEATHING SECURED WITH
(1)#12-14xi" SELF -DRILLING SCREWS
'2-1-2-1' (6" O.C. (9" O.C. MAX.))
#12-14xi"
SELF -DRILLING SCREWS
10" O.C. MAX., 3"
MAX. FROM CORNERS
HORIZONTALLY/ 4" MAX.
FROM CORNERS
VERTICALLY
18
#14x1"
SELF -DRILLING
SCREWS CAD 6" O.C.
MAX. & 6" MAX.
FROM CORNERS
EXTERIOR 16 GAUGE FURRING CHANNEL
2»�
48" O.C. MAX. SECURED WITH
n' (2)#12-14x1" SELF -DRILLING
' \! SCREWS TO EACH RAFTER.
DOOR FRAME TO POST
CONNECTION
ROLL -UP DOOR TO
POST CONNECTION
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14x4"
SELF -DRILLING SCREWS
SINGLE OR DOUBLETS
HEADER
HEADER CONNECTION
DETAIL OPTION 1
26 GAUGE ROOF SHEATHING
SECURED WITH (1)#12-14xi"
SELF -DRILLING SCREWS
'2-1-2-1' (6" O.C. (9" O.C. MAX.))
16 GAUGE FURRING CHANNEL
48" O.C. MAX. SECURED WITH
(2)#12-140" SELF -DRILLING
SCREWS TO EACH RAFTER.
ROOF PANEL CONNECTION
VERTICAL SHEATHING OPTION
EAVE & RIDGE REINFORCED ROOF P
(RIDGE 3r AND EAVE 3e)
Enclosed Design Pressures - 160 mph Basic Wind Speed
Zone
Roof
Wall
1
2n
2r
2e
3r
3e
4
5
13.0
15.0
9.6
9.6
15.0
15.0
15.0
18.1
-37.2
-54.4
-29.6
-11.6
-64.3
-54.4
-16.7
-22.8
Open Design Pressures - 160 mph Basic Wind Speed
Zone
Roof
Wall
1
2n
2r
2e
3r
3e
4
5
17.1
22.3
17.1
17.1
24.5
24.5
24.5
27.8
-20.8
-59.0
-40.2
-20.8
-77.9
-67.1
-26.3
-32.9
m
ilwwol►1o1xo11[o7
LE
: Ri
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
12-14xi" SELF -DRILLING
EWS
SINGLE OR DOUBLETS
HEADER
HEADER CONNECTION DETAIL
OPTION 2
2 - 2"x2"x2" 16 GA. ANGLE CLIPS
SECURED WITH (4) #12-14xi"
SELF -DRILLING SCREWS (PER CLIP)
LEAN-TO TO TRUSS
CONNECTION
TO
1 "x2j" 16 GA.
U-CHANNEL BRACE, MIN.
24" UP TO 7' POST, Mlr
48" OVER 7' POST. MIN.
45' TO MAX. 60' FROM
HORIZ. (EXCLUDE
END -WALLS). SECURED
WITH (4)#12-14x4"
SELF -DRILLING SCREWS.
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
(4)SCREWS #12-14xi" SELF -DRILLING
BOX EAVE RAFTER TO
POST CONNECTION DETAIL
APPROVED PRODUCTS
APPROVAL NO.
ROOF SHEATHING
Carports Anywhere
FL27402.1
Hampton Rib Roof Panel
WALL SHEATHING
Carports Anywhere
FL27403.1
Hampton Rib Wall Panel
SWINGING DOOR
ELIXER DOOR AND METAL COMPANY
FL17996.5
407 STEEL DOOR
ROLL -UP DOOR
JANUS INTERNATIONAL CORPORATION
FL21450.3
SERIES 3100
CODE VERSION
FBC 2020 7th Edition,
ASCE-7-16
MANUFACTURER
CARPORTS ANYWHERE
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II-B
RISK CATEGORY
I
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
JUTILITY, U
WIND SPEED
Vult-160mph
ENCLOSURE
ENCLOSED/OPEN
INTERNAL PRESSURE COEFF.
+/- 0.18/0.0
IMPORTANCE FACTOR
1.0
ROOF DEAD LOAD
1OPSF
ROOF LIVE LOAD
20PSF OR 3001b P.L.
FLOOR DEAD LOAD
1OPSF
FLOOR LIVE LOAD
50PSF
"R"RATING OF WALLS,FLOOR,ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
1,320 SQ. FT.
DATE
DRAWN BY: MTB
DATE` 4/21 /21
'cATl%55 S Indian River Dr, Jensen Beach
SIZE: 30'L X 44'W X 12'H
cn
J_
Q
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND w w
THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES � 0 Sheet:
Matthew T. Baldwin P.E.
Florida License #64608
CA-4 OF 4