Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 15 Block 3 Waterstone 2265 CRTGGL Builder Name: ADAMS HOMES Street: 8340 Amalfi Circle Permit Office: City, State, Zip: Fort Pierce, FL, 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type42018.2 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1378.30 ftZ 3. Number of units, if multiple family 1 b. Frame - Wood, Exterior R=13.0 407.83 ftZ c. Frame - Wood, Adjacent R=13.0 232.00 ftZ 4. Number of Bedrooms 4 d. N/A R= ftZ 5. Is this a worst case? No 11. Ceiling Types (2357.0 sqft.) Insulation Area 6. Conditioned floor area above grade (ftZ) 2277 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 2277.00 ftZ R=19.0 80.00 ftZ Conditioned floor area below grade (ftZ) 0 c. N/A R= ftZ 7. Windows(293.9 sqft.) Description Area 12. Ducts R ftZ a. U-Factor: Dbl, U=0.33 166.06 ftZ a. Sup: Attic, Ret: Main, AH: Main 6 456.2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 70.92 ftZ 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.55 35.56 ftZ SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 4.849 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.288 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ftZ 15. Hot water systems SHGC(AVG): N/A 9. Floor Types (2277.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ftZ b. Conservation features EF: 0.940 b. N/A R= ftZ None c. N/A R= ftZ 16. Credits Pstat Glass/Floor Area: 0.129 Total Proposed Modified Loads: 67.31 PASS Total Baseline Loads: 67.76 I hereby certify that the plans s cations covered this Revi of the plans and T:ST ��8.' calculation are in compl' a on a rgy Code. specifications covered by this calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 08-n.1-2071IA/inn Keo nany this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. ,S . .• with the Florida Ener' OWNER/AGENT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). J 6/3/2021 10:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Lot 15 Block 3 Waterstone 2 Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2277 Lot # 15-3 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 8340 Amalfi Circle Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce Family Type: Detached , New/Existing: New (From Plans) FL, 34951 Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2277 20493 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2277 20493 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0 2277 ftz ---- 0.35 0 0.65 ROOF / V # Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2546 ftz 570 ft' Medium N 0.85 N 0.85 No 0 26.57 ATTIC ` / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2277 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2277 ft' 0.11 Wood 2 Knee Wall (Vented) Main 19 Batt 80 ft2 0.11 Wood �j 6/3/2021 10:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 rvruvl :Y 1 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NW Exterior Frame - Wood Main 13 10 2 8 0 81.3 ft2 0 0.23 0.6 0 0 2 NW Exterior Concrete Block - Int Insul Main 4.1 38 7 10 0 385.8 ft2 0 0 0.6 0 f _ 3 SW Exterior Frame - Wood Main 13 4 6 10 0 45.0 ft2 0 0.23 0.6 0 4 SW Exterior Concrete Block - Int Insul Main 4.1 28 6 10 0 285.0 ft2 0 0 0.6 0 5 SE Exterior Frame - Wood Main 13 6 9 8 0 54.0 ft2 0 0.23 0.6 0 6 SE Exterior Concrete Block - Int Insul Main 4.1 50 3 8 0 402.0 ft2 0 0 0.6 0 7 8 9 _10 11 E E NE NE - Exterior Exterior Exterior Exterior Garage Frame - Wood Concrete Block - Int Insul Frame - Wood Concrete Block- Int Insul Frame - Wood Main Main Main Main Main 13 3 4.1 0 13 18 4.1 37 13 29 10 5 11 8 0 10 10 10 8 8 0 0 0 0 0 38.3 ft2 4.2 ft2 189.2 ft2 301.3 ft2 232.0 ft2 0 0 0 0 0 0.23 0 0.23 0 0.23 0.6 0.6 0.6 0.6 0.01 0 0 0 0 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 - Wood Main None .25 2 8 6 8 17.8 ft2 2 SE Insulated Main None .25 3 6 8 20 ft2 WINDOWS Orientation shown is the entered. Prnnncprl nripnrarinn / V/ # Ornt Wall ID Frame Panes NFRC U-Factor SHGC Imp Area Overhang Depth Separation Int Shade Screening 1 NW 1 Vinyl Law-E Double Yes 0.55 0.7 N 17.8 ft2 23 ft 0 in 0 ft 9 in Drapes/blinds None 2 NW 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 3 SW 3 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft2 7 ft 8 in 0 ft 6 in None None 4 SW 4 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 7 ft 8 in 2 ft 10 in None None 5 SW 4 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 6 SW 4 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ft2 1 ft 0 in 2 ft 10 in Drapes/blinds Exterior 5 7 SE 6 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 0 in Oft 10 in Drapes/blinds Exterior 5 8 SE 6 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 9 E 7 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft2 11 ft 0 in 0 ft 4 in Drapes/blinds Exterior 5 10 NE 9 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 9 ft 4 in 0 ft 9 in Drapes/blinds None 11 NE 9 Vinyl Low-E Double Yes 0.33 0.23 N 16.7 ft' 6 ft 8 in 0 ft 4 in Drapes/blinds Exterior 5 12 NE 9 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 9 ft 4 in 0 ft 4 in Drapes/blinds Exterior 5 13 NE 9 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 14 SW 4 Vinyl Low-E Double Yes 0.33 0.31 N 3.0 ft2 1 ft 0 in 1 ft 8 in Drapes/blinds None ti .J, 6/3/2021 10:32 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5 .A: FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 617ft2 617ft2 64ft 8ft 1 INFILTRATION y # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 Y 1 Wholehouse ff Proposed ACH(50) .0004 2390.9 131.17 246.26 .1324 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing] SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / # ---- Supply ---- Location R-Value Area ---- Return --- Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 456.2 ft Main 114.05 Default Leakage Main (Default) (Default) 1 1 6/3/2021 10:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling an Heating f X] Jan Venting Feb f X Feb Mar Mar A r f APr May f May X Jun f Jun Jul Jul ri X Au Au I lAugSe [X Se Sep Oct Oct Nov Nov Dec Dec [ ]Jan [ Feb X Mar [X] A r [ Ma [ Jun Jul E [X] Oct X Nov Dec r Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main 6/3/2021 10:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 8340 Amalfi Circle, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1378.30 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Exterior R=13.0 407.83 ft2 c. Frame - Wood, Adjacent R=13.0 232.00 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area 6. Conditioned floor area (ft2) 2277 a. Under Attic (Vented) b. Knee Wall R=30.0 2277.00 ft2 (Vented) R=19.0 80.00 ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.33 166.06 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.23 a. Sup: Attic, Ret: Main, AH: Main 6 456.2 b. U-Factor: Dbl, U=0.33 70.92 ft2 SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 35.56 ft2 a. Central Unit 35.0 SEER:16.00 SHGC: SHGC=0.70 d. U-Factor: other (see details) 21.33 ft2 SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 4.849 ft. a. Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average SHGC: 0.288 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.94 9. Floor Types Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ft2 None b. N/A R= ft2 Credits (Performance method) Pstat c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: N w- Date: City/FL Zip: "Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. ""Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/3/2021 10:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1