HomeMy WebLinkAboutAPPROVED Prod Approv-Soprema Underlay.M:
BCIS Home Log In User Registration Hot Topics Submit Surrharge Stats & Facts Publications Contact Us $CIS Site Map Links Search
do Product Approval
USER: Public User
r
Frocvice G?^-0,a] X-Zu > Producz or c"Lca;io� Sea-& > Ano!`cation List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Rhone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration pate
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FL2569-R21
Revision
2020
Approved
Soprema, Inc. (Canada)
164D rue Haggarty
Drummondville, NON -US 00000
(819) 478-2400
m em ath ie u @soprema. ca
Marc -Etienne Mathieu
memath ieu @soprema. ca
Marc -Etienne Mathieu
1688 lean-eerchmans- Michaud
Drummondville, NON -US 00000
(819) 478-2400 Ext3327
memathieu@soprema.ca
Jean -Francois Cote, Ph.D.
1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Robert 3. M. Nieminen
PE-59166
UL LLC
12/21/2023
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL2569 R21 COI 2020 01 COI NIEMINEN. df
Standard
Year
ASTM 01970
2015
ASTM D4798
2011
ASTM D6163
2015
FM 4474
2011
FRSA/TRI Sixth Edition 2018
UL 1897 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Method 1 Option D
Date Submitted 12/16/2020
Date Validated 12/17/2020
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
Summary of Products
FL # Model, Number or Name Description
2569.1 Soprema Roof Undedayments I Self adhering roof underiayments
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-150
I. Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The
design pressure noted herein pertains to underlayment
systems used beneath adhesive -set tile systems. Refer to ER
Section 5.8.3 for details.
Installation Instructions
FL2569 R21 II 2020 12 16 FINAL ER SOPREMA FZ569
RZRZZ S.odf
Verified By: Robert Nieminen, P.E. PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL2569 R21 AE 2020 12 16 FINAL ER SOPREMA FL2569-
Created by Independent Third Party: Yes
pack Next'
Contact Us :: 2601 Blair stone Road. 'Tallahassee 39 Phone: 850-487-1824
The state of Honda is an AA/EEO employee Copyright 2007-2013 State of Florida :: P.ivaw Statement:: A2esaibility Statement:: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail acidness released in response to a public-racordc request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any Questions, please contact 850.487.1395. •Pursuant to section
455.275(1), Ronde statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish W supply a
personal address, please provide the Department with an email address which can be made available W the public To determine if you are a licensee under Chapter
455, F.S., please click hem_.
Product Approval Accepts:
M© ® 4n
Cretin Card
Safe
NEMO j etc.
Certificate ofAuthor zadon #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
I.LUATION RFPOR
Soprema, Inc. Evaluation Report S18010.06.09-1119
1640rue Haggerty FL2569-R21
Drummondville, Quebec.12C SP8 Canada Date of Issuance: 06/15/2009
(819) 478-2400 Revision 19:12/16/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 71' Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LAsEuNG: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPUANCE: This Evaluation Reportis valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADvERnsEMENT: The Florida Product Approval Number (FL#) preceded by the words 'NEMO Ietc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9
Prepared by:
..... .-
�,,, ...
Robert J.M. Nieminen, P.E.
The fwWmilesea[ appearing easanhorizedbyRooert
Florida Registration No, 59166 Florida DCA ANE1983
',`3„"�;•<•�`�--
.!,�„_.;_�E
Nieminen, P.E. on does not serve as
an electronically signed documetrt.
geed doourneft
CERTIRMON OF INDEPENDENCE
1. NEMO ETC, LLC does not have, nor does it intend to acquire orwill it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
®2019 NEMO ETC, LLC
ONEMOf etc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Soprema Roof Underlaymems, as produced by Soprema, have demonstrated compliance
with the following sections of the r Edition (2020) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use
set forth herein.
STANDARDS:2.
Section Property Standard Year
1SO4.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2015
1507.1.1, 1507.2.4,1507.2.9.2 Material standard ASTM D1970 2015
/ R905.1.1, R905.2.8.2
1507.33 / R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018
1507.11.2 / R905.11.2 Material standard ASTM D6163 2015
I AS 110 Accelerated Weathering ASTM D4798 2011
Enti Examination Reference Date
ERD (T576049) Wind Resistance 2778.07.05 07/15/2005
ERD (TST6049) ASTM D197C / TAS 110 (QC) S31370.03.10-1-R1 04/07/2010
ERD (TST6049) FRSA/TRI D4-12(OH) S11150.05.09-112 10/05/2010
ERD (TST6049) ASTM D1970 (OH) S37210.11.11 11/09/2011
ERD (TST6049) ASTM D1970 (MS) 537210.12A1 12/01/2011
ERD (TST6049) ASTM D1970 (MS) S40540.02.13-1 02/19/2013
ERD (TST6049) FRSA/TRI 04-12 (MS) S43530.02.14-1-R1 02/21/2014
ERD (TST6049) ASTM D1970 (BC) S44870.04.14-2 04/02/2014
ERD (TST6049) ASTM D1970 (QC) S44870.04.14-3 04/02/2014
ERD (TST6049) ASTM D1970 (OH) S44870.04.141 04/10/2014
ERD (TST6049) ASTM D1970 (MS) S44870.D4.14-4 04/10/2014
ERD (TST6049) ASTM D1970 (OH) S40540.10.14 10/31/2014
ERD (TST6049) Tensile Adhesion / Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD (TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015
ERD (TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018
ICC-ES (EVL2396) 201513C Compliance ESR-1524 03/01/2017
NEMO (TST6049) ASTM D1970 / TAS 110 (QC) SOPC SC8970.08.15-Rl 04/25/2018
NEMO (TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018
NEMO (TST6049) ASTM D4798/1)1970 (OH & MS) 4S-SOPC-16-002.05.19.A 05/31/2019
NEMO (TST6049) Tensile Adhesion/Long Term Aging 4p-DOW-I9-SSLAP-01.AR2 02/10/2020
NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020
NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-20-SSUDL-01 12/16/2020
PRI (TST5878) ASTM D1970 (MS) SOP-064-02-01 12/03/2013
Soprema, Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL, LLC (QUA9625) Quality Control MLA File No. R16814 12/10/2015
UL, LLC (QUA9625) Quality Control MLA File No. R27605 05/08/2019
UL, LLC (QUA9625) QualityControl Service Confirmation 06/29/2020
UL, LLC (QUA9625) Quality Control Florida BCIS Current
NEMO ETC, LLC Evaluation Report518010.06.09-R19
Cernfimre of Authonwvan#32455 7- EDITION(202D) FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19: 12/1512020
Page 2 of 9
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
ONEMOjetc.
Product
Material
Plant(s)
Description
Standard
Lastobond TU HT
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric
FRSA/TRI 09-18
surfaced, SBS modified bitumen roof
underlayment
Tri-Built S/A HT TU
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric
Underlayment
FRSA/TRI 09-18
surfaced, SBS modified bitumen roof
underlayment
Lastobond Shield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
RESISTO SA SMOOTH PLY
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
40
modified bitumen roof underlayment
Lastobond Shield HT
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
Lastobond Pro HT-N
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
Lastobond Pro HT-S
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
Enviro5hield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
Lastobond 195
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
Lastobond Eaves
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -
Protection Sheet
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
Lastobond Eco
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
Lastobond Smooth Seal
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
Tri-Built Smooth HT S/A
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film-
Underlayment
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
PrimeSource Grip -Rite
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
Smooth Seal HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
RESISTO LB1236
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
TRI-BUILT Sand-R SA
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Shingle Underlayment
Gulfport, MS
surfaced, SIBS modified bitumen roof
Wadsworth, OH
underlayment
NEMO ETC, LLC Evaluation R sport518010.06.09-R19
Certii lu of Aurhorfzadon #32455 7- EDMON (2020) FSC NON-HVHZ EVALUATION F1.2569-1121
Soprema Roof Underlayments Revision 19: 12/15/2020
Page 3 of 9
4.17
4.18
4.19
4.20
ONEMO
I etc.
Material
Product
Standard
Plant(s)
Description
PrimeSource Grip -Rite
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand-
Eave & Valley Protector
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
SRS TopShield ICE &
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
WATER DEFENDER
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
I underlayment
RESISTO LB1244
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
undedayment
Colphene FR GR
ASTM D6163
Gulfport, MS
self -adhering, fiberglass reinforced, granule -
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data forthe prepared roof covering.
5.6 Allowable Roof Covers:
TABLE I: ROOF COVER OPTIONS
FWSecdm:
1507.2
1S073
1 07.4& 1507.5
1 1507.7
1507.a& 1507.9
Clay and Concrete Tile
Metal
Slate or
Underlayment
Asphalt
Shingles
Slate -Type
Wood Shakes or
Mechanical
Adhesive-
Attach
Set
Panels
Shingles
Shingles
Shingles
Lastobond TU HT, Tri-Built S/A FIT TU
Yes
Yes
Underlayment
Yes
yes
See5.6.1
yes
yes
Yes
(ie�ntstrips,ssm.LLa/
Rsu.».s1
Lastobond Shield, Pro HT-N, RESISTO SA
Yes
SMOOTH PLY 40
Yes
No
No
No
No
Yes
(purcm;m tso7.1-1 1/
asos.LLs)
Yes
Lastobond Shield HT, Pro FITS
Yes
No
No
Yes
Yes
Yes
1in;,,tsmcs ssol LLa�
asns.Ltaj
EnviroShield
Yes
No
No
Yes
yes
Yes
Yes
6antstricr,tswst /
RMS-LL3)
Lastobond Eaves Protection Sheet,
Yes
Lastobond 195
Yes
No
No
No
No
Yes
pdixmips, 35W.133f
R9a5.L13)
NEMO ET, LC Evaluation Rep
ort 518010.06.09-R19
Ceitifirate of Authorization#32455 7-EDmON[2020) FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 4 of 9
ONEMOjetc.
TABLE 1: ROOF COVER OPTIONS
FBCSealon:
1507.2
1507.3
1507.4 & 1507.5
1507.7
1507.8 & 1507.9
Gay and Concrete Tile
Metal
Slate or
Underlayment
Asphalt
P
Slate -Type
Wood Shakes or
Mechanical
Adhesive-
Shingles
Attach
Set
Pawls
Shingles
Shingles
Shingles
Lastobond ECO, RESISTO L61236, TRI-
BUILT Sand-R SA Shingle Underlayment,.
yes
Grip -Rite Eave& Valley Protector,
Yes
No
No
No
No
Yes
�mmsncs. tsozu3/
TopShield ICE & WATER DEFENDER,
3sos.l.t3)
RESISTO LB1244
Lastobond Smooth Seal HT, Tri-Built
Yes
Smooth HTS/A Underlayment, Grip -Rite
Yes
No
No
Yes
Yes
Yes
�ointsuips, l5a).1.13/
Smooth Seal HT
asos.v31
Yes
Colphene FR GR
Yes
Yes
No
No
No
Yes
W. strip:, t .u3/
R905.1131
5.6.1 Adhesive -set tile is limited to use of the following Approved underlayment/tile-adhesive combinations.
TABLE 3A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS2
Underlayment
I Adhesive
Florida Product Approval
Lastobond TU HT, Tri-Built 5/A
HT TU Underlayment
Dupont "Tile Bond- Roof Tile Adhesive"
FL22525
ICP Adhesives and Sealants "Polysete AH-160"
FL6332
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment
Application
Substrates (designed to meet wind loads for project)
Type Primer Material(s)
Lastobond Shield, Lastobond Pro
(Optional) ASTM
FIT-N, RESISTO SA SMOOTH PLY
Deck /
D41, Elastocol Stick,
Plywood, OS8 or Southern Yellow Pine
40, Lastobond Shield HT,
sheathing
Elastocol Stick Zero
(SYP)
Lastobond Pro HT-S,
ASTM D41
structural concrete
Envri-Built S/A, Lastobond TU Fff,
Tri-Built S/A HT TU
Insulation
(Optional) Elastocol
Dens Deck Prime or SECUROCK Gypsum-
Underlayment, Lastobond Eaves
Stick Zero
Fiber Roof Board
Protection Sheet, Lastobond 195,
self-
Lastobond ECO, RESISTO LB1236,
TRI-BUILT Sand-R SA Shingle
adhering
Underlayment, Grip -Rite Eave &
Valley Protector, TopShield ICE &
Base Sheet
(Optional) Elastocol
ASTM D226, Type II felt or Modified Sopra-
WATER DEFENDER, RESISTO
Stick Zero
G
L61244, Lastobond Smooth Seal
HT, Tri-Built Smooth HT S/A
Underlayment or Grip -Rite
Smooth Seal HT
(Optional) ASTM
Deck/
D41
Plywood
sheathing
ASTM D41
structural concrete
self -
Insulation
(Optional) Elastocol
Dens Deck Prime or SECUROCK Gypsum -
Colphene FR GR
adhering
Stick Zeno
Fiber Roof Board
Base Sheet
(Optional) Elastocol
ASTM D226, Type II felt or Modified Sopra-
Stitk Zero
G
' Refer to Tile Manufacturer's orAdheslve Manufacturer's Florida ProductApproval for Overturning Moment Resistance Performance.
MEMO ETC, LLC Evaluation ReportS16010.06.09-R19
Cemficate ofAuthorization k32455 7- EDITION (20201 FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Undedayments Revision 19:12/15/2020
Page 5 of 9
ONEMOletc.
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates (designed to meet wind loads for project)
Underlayment
Application
Type Primer Material(s)
Lastobond TU HT, Tri-Built 5/A HT
TU Underlayment, RESISTO
LB1236, TRI-BUILT Sand-R SA
self-
Existing
RESISTO EXTERIOR
Existing sand -surfaced, glass -fiber surfaced,
Shin a
gl Underlayment, Grip -Rite
adhering
substrate
PRIMER
mineral -surfaced or film -surfaced roof
Eave &Valley Protector
r or
underlayment"
TopShield ICE & WATER
DEFENDER
*Final acceptance of any existing substrate in a reroof (tear-offJ installation is at the discretion of the installer and the Authority
Havinglurisdiction. Should a question arise as to the suitability of an existing substrate to receive Lastobond TU HT, Tri-Built S/A HT
TU Underlayment, RESISTO L81236, TRI-SUILTSond-RSA Shingle Underlayment Grip -Rite Eave & Valley Protector or TopShield ICE &
WATER DEFENDER self -adhering underlaymeriM contact RESI570 technical support.
5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB pdorto installation of the
self -adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachmentshall be in accordance with
the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets -not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but —for mechanically attached base sheets - not less than:
• FRSA/Ml Florida High Wind Concrete and Gay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1 (for Two -Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure =-45.Opsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, Tri-Built 5/A HT TU Underlayment, self -adhered.
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU FIT, Tri-Built S/A HT TU Underlayment, self -adhered.
NEMO ETC, LLC Evaluation Report S18010.06.09-R19
Cerfitr ofAuthorization#32455 7"EDMON(2020) FBC NON-FIVHZ EVALUATION FI2569-R21
Soprema Roof Underlayments Revision 19; 12/15/2020
Page 6 of 9
ONEMOletc.
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRER-DEIX TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
Lastobond TU HT, Tri-
Built 5/A HT TU
Underlayment
Lugged
Max. 10-tile stack (bottom 2-tile stack shall be inverted,
followed by 8 tiles high on slope, as shown below)
6:12
1
Colphene FR GR
Flat
Max. 10-tile stack
5:12
Lugged
Max. 10-tile stack
6:12
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.2.1 Installation of RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or
TopShield ICE & WATER DEFENDER self -adhering underlayment in a reroof (tear -off) application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE
& WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
6.3 Lastobond TU HT, Tri-Built S/A HT TU Underlayment, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA
SMOOTH PLY 40, Lastobond Shield HT, Lastabond Pro HT-S, EnviroShield, Lastobond Eaves Protection Sheet,
Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment, Grip -Rite
Smooth Seal HT, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley
Protector, TopShield ICE & WATER DEFENDER, RESISTO LB1244 or Colphene FR GR:
b.3.1 Non- I Ile AODIlcations,
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R90S.S.L3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.L1.
NEMO ETC, LLC Evaluation ReportS16010.06.09•Ri9
Cerrfffote of Autharization#32455 7- EDITION (2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/202D
Page 8 of 9
MEMO I etc.
6.3.2 Tile Applications:
Limited to Lastobond TU HT, Tri-Built S/A HT TU Underlayment or Colphene FIR GR.
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturers installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
.•. _".fro - _ '(s -�
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the named CA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
UL, LLC— QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
MEMO ETC, LLC Evaluation Report 518010.06.09-R19
Certftate ofAuthonmtion#32C55 7-EDMON(2(120)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19: 12/15/2020
Page 9 of 9
ONEMO I etc.
#3 Maximum Design Pressure = -120.0 osf:
Deck: Min. 15/32-inch APA-rated COX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered.
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
#4 Maximum Design Pressure=-150.0 osf:
Deck: Min. 15/32-inch APA-rated BC( plywood (may be installed C-side up) to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment, self -adhered.
#5 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of -45 psf.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Gay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
A)tematively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29, Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Design Pressure=-60.0 osf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-
inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be in accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
Prepared Roof Cover
Maximum
Installation Type
Exposure(days)
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO L81236, TRI-
BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE
Mechanically
30
& WATER DEFENDER or RESISTO LB1244
attached
Lastobond TU HT, Tri-Built S/A HT TU Underlayment
Adhesive -set file roof
30
system
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-5, Enviro5hie)d, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A
Mechanically
90
Underlayment or Grip -Rite Smooth Seal HT
attached
Lastoband TU HT, Tri-Built S/A HT TU Underlayment or Colphene FR GR
Mechanically
180
attached
NEMO ETC, LLC Evaluation Report 918010.06.09-R19
Cerdfione of Authorization#32455 7- EDMON (2020) FBC NON-HVHZ EVALUATION FL2969-R21
5oprema Roof Underlayments Revision 19:12/15/202D
Page 7 of 9