HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 28 Phase-3 Waterstone 2265 CRTGGR
Builder Name: ADAMS HOMES
Street: 8319 Amalfi Circle
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number.
Owner:
Jurisdiction: 661000
Design Location: FL, ST LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type41994.2 sqft.)
Insulation Area
2. Single family ormultiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1378.30 ftz
b. Frame -Wood, Exterior
R=13.0 407.83 ftz
3. Number of units, if multiple family 1
c. Frame - Wood, Adjacent
R=13.0 208.00 ftz
4. Number of Bedrooms 4
d. N/A
R= ftz
5. Is this a worst case? No
11. Ceiling Types (2357.0 sqft.)
Insulation Area
a. Under Attic (Vented).
R=30.0 2277.00 ftz
6. Conditioned floor area above grade (ftz) 2277
b. Knee Wall (Vented)
R=19.0 80.00 ftz '
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz .
7. Windows(273.9 sqft.) Description Area
12: Ducts
R ftz
a. Sup: Attic, Ret: Main, AH: Main
6 456.2
a. U-Factor: Dbl, U=0.33 154.00 ftz
SHGC: SHGCF0.23
;
b. U-Factor: DbI, U=. 3 66.00 ftz
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor. Dbl,.U=0.55 35.56ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 5.043 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.292
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ftz
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2277.0 sqft.) Insulation Area
EF:0.940
a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
16. Credits
Pstat
Glass/Floor Area: 0.120 Total Proposed Modified Loads: 65.48
PASS
- Total Baseline Loads: 66.97
hereby certify that the plans ]cations covere
Rev w of the plans. andZ>'s?�q?.
this calculation are in comp n ]th the Flora rgy
specifications covered by this
Apt
Code. _
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 03-2Kenmany.
this building will be inspected for
compliance with Section 553.908
;` I A a;
I herebycertify that this building, as das' ned, is in com liance
fY 9� p
Florida Statutes.
y:
with the Florida ERe de-
cOD��iFw'.
.OWNER/AG
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH56 (R402.4.1.2).
3/23/2021 8:59 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5
-FORM A405-2020 INPUT SUMMARY CHECKLIST RFPnRT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 28 Phase 3 Waterstone 2 Bedrooms: 4
User Conditioned Area: 2277
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Lot Information
Lot # 28
Block/Subdivision: Waterstone
PlatBook:
Street: 8319 Amalfi Circle
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2277 20493
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2277 20493 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0
2277 ftZ ---- 0.35 0 0.65
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2546 ftZ 570 ftz Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2277 ftZ N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
2277 ftZ 0.11 Wood
80 ftz 0.11 Wood
3/23/2021 8:59 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
FURM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing
Solar Below
_ 1
N
Exterior
Frame - Wood
Main
13
10
2
8
0
81.3 ft2
0
0.23
0.6
0
2
N
Exterior
Concrete Block - Int Insul
Main
4.1
38
7
10
0
385.8 ft2
0
0
0.6
0
3
E
Exterior
Frame - Wood
Main
13
4
6
10
0
45.0 ft2
0
0.23
0.6
0
4
E
Exterior
Concrete Block - Int Insul
Main
4.1
28
6
10
0
285.0 ft2
0
0
0.6
0
5
S
Exterior
Frame - Wood
Main
13
6
9
8
0
54.0 ft2
0
0.23
0.6
0
6
S
Exterior
Concrete Block - Int Insul
Main
4.1
50
3
8
0
402.0 ft2
0
0
0.6
0
7
SW
Exterior
Frame - Wood
Main
13
3
10
10
0
38.3 ft2
0
0.23
0.6
0
8
SW
Exterior
Concrete Block - Int Insul
Main
4.1
0
5
10
0
4.2 ft2
0
0
0.6
0
9
W
Exterior
Frame - Wood
Main
13
18
11
10
0
189.2 ft2
0
0.23
0.6
0
10
W
Exterior
Concrete Block - Int Insul
Main
4.1
37
8
8
0
301.3 ft2
0
0
0.6
0
11
-
Garage
Frame - Wood
Main
13
26
0
8
0
208.0 ft2
0
0.23
0.01
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood -
Main
None
.25
2
8
6 8
. 17.8 f1:2
3
S
Insulated
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Omt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N
1
Vinyl
Low-E Double
Yes
0.55
0.7
N
17.8 ft2
23 ft 0 in
0 ft 9 in
Drapes/blinds
None
2
N
2
Vinyl
Low-E Double
Yes
0.33
0.23
N
30.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
3
E
3
Vinyl
Low-E Double
Yes
0.33
0.31
N
5.0 ft2
7 ft 8 in
0 ft 6 in
None
None
4
E
4
Vinyl
Low-E Double
Yes
0.33
0.31
N
13.3 ft2
7 ft 8 in
2 ft 10 in
None
None
5
E
4
Vinyl
Low-E Double
Yes
0.33
0.21
N
30.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
6
E
4
Vinyl
Low-E Double
Yes
0.33
0.21
N
36.0 ft2
1 ft 0 in
2 ft 10 in
Drapes/blinds
Exterior 5
7
S
6
Vinyl
Low-E Double
Yes
0.33
0.23
N
9.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
8
S
6
Vinyl
Low-E Double
Yes
0.33
0.23
N
15.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
9
SW
7
Vinyl
Low-E Double
Yes
0.33
0.23
N
12.5 ft2
11 ft 0 in
0 ft 4 in
Drapes/blinds
Exterior 5
10
W
9
Vinyl
Low-E Double
Yes
0.55
0.7
N
17.8 ft2
9 ft 4 in
0 ft 9 in
Drapes/blinds
None
11
W
9
Vinyl
Low-E Double
Yes
0.33
0.23
N
12.5 ft2
6 ft 8 in
0 ft 4 in
Drapes/blinds
Exterior 5
12
W
9
Vinyl
Low-E Double
Yes
0.33
0.23
N
30.0 ft2
9 ft 4 in
0 ft 4 in
Drapes/blinds
Exterior 5
13
W
10
Vinyl
Low-E Double
Yes
0.33
0.23
N
45.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
3/23/2021 8:59 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORMA405-2020 INPUT SUMMARY CHECKLIST RFPART
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
617 ft2
617 ft2
64 ft 9 ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.0004
2390.9 131.17 246.26 .1324 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Heat Pump/
Split
Singl HSPF:8.5 34.6 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 16 35 kBtu/hr cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert #
Company Name
Collector Storage
System Model # Collector Model # Area Volume FEF
None
None
ft2
DUCTS
#
- — Supply----
Location R-Value Area
-- Return ---- Air CFM 25 CFM25 HVAC #
Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1
Attic 6 456.2 ft
Main
114.05 Default Leakage Main (Default) (Default)
1 1
3/23/2021 8:59 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORMb405-2020 INPUT SUMMARY CI-IFCKI IST RFPART
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
HeatinJan
r 1 Feb
[X] Feb
Mar
Mar
Apr
E Apr
f
Ma
I May
Jun
n Jun
Jul
rj Jul
Au
f Aug
Se
SeP
ri
Oct
Oct
Nov
Nov
Dec
Dec
Ventin Jan
[[[[ ]]]] Feb
Mar
[X] A r
[
Ma
[[[ jjj Jun
Jul
[ Au
Se
[X] Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
3/23/2021 8:59 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY- PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient :the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.21
c. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.70
d. U-Factor: other (see details)
SHGC: other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
8319 Amalfi Circle, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1378.30 ft2
b. Frame - Wood, Exterior
R=13..0
407.83 ft2
1
c. Frame.- Wood, Adjacent
R=13.0
208.00 ft2
4
d. N/A
R=
ft2
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.6
2277.00 ft2
2277
b. Knee Wall (Vented)
R=19.0
80.00 ft2
Area
c. N/A
R=
ft2
154.00 ft2
12. Ducts, location &.insulation level
R ft2
a. Sup: Attic, Ret' Main, AH: Main
6 456.2
66.00 ft2
13. Cooling -systems .
kBtu/hr
Efficiency
35.56 ft2
a. Central Unit
35.0 SEER:16.00
18.33 ft2
5.043 ft.
0.292
Area
ft2
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ft2
b. N/A R= ft2
c. N/A R= ft2
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code corrinUanifeatures.
Builder Signatur Date:
Address of New Home:
City/FL Zip:
kBtu/hr Efficiency
34.6 HSPF:8.50
Cap: 40 gallons
EF: 0.94
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/23/2021 8:59 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1