Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 28 Phase-3 Waterstone 2265 CRTGGR Builder Name: ADAMS HOMES Street: 8319 Amalfi Circle Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number. Owner: Jurisdiction: 661000 Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41994.2 sqft.) Insulation Area 2. Single family ormultiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1378.30 ftz b. Frame -Wood, Exterior R=13.0 407.83 ftz 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=13.0 208.00 ftz 4. Number of Bedrooms 4 d. N/A R= ftz 5. Is this a worst case? No 11. Ceiling Types (2357.0 sqft.) Insulation Area a. Under Attic (Vented). R=30.0 2277.00 ftz 6. Conditioned floor area above grade (ftz) 2277 b. Knee Wall (Vented) R=19.0 80.00 ftz ' Conditioned floor area below grade (ftz) 0 c. N/A R= ftz . 7. Windows(273.9 sqft.) Description Area 12: Ducts R ftz a. Sup: Attic, Ret: Main, AH: Main 6 456.2 a. U-Factor: Dbl, U=0.33 154.00 ftz SHGC: SHGCF0.23 ; b. U-Factor: DbI, U=. 3 66.00 ftz 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor. Dbl,.U=0.55 35.56ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 5.043 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.292 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ftz 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (2277.0 sqft.) Insulation Area EF:0.940 a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 16. Credits Pstat Glass/Floor Area: 0.120 Total Proposed Modified Loads: 65.48 PASS - Total Baseline Loads: 66.97 hereby certify that the plans ]cations covere Rev w of the plans. andZ>'s?�q?. this calculation are in comp n ]th the Flora rgy specifications covered by this Apt Code. _ calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 03-2Kenmany. this building will be inspected for compliance with Section 553.908 ;` I A a; I herebycertify that this building, as das' ned, is in com liance fY 9� p Florida Statutes. y: with the Florida ERe de- cOD��iFw'. .OWNER/AG BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH56 (R402.4.1.2). 3/23/2021 8:59 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 -FORM A405-2020 INPUT SUMMARY CHECKLIST RFPnRT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 28 Phase 3 Waterstone 2 Bedrooms: 4 User Conditioned Area: 2277 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Lot Information Lot # 28 Block/Subdivision: Waterstone PlatBook: Street: 8319 Amalfi Circle County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2277 20493 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2277 20493 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0 2277 ftZ ---- 0.35 0 0.65 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2546 ftZ 570 ftz Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2277 ftZ N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 2277 ftZ 0.11 Wood 80 ftz 0.11 Wood 3/23/2021 8:59 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 FURM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 N Exterior Frame - Wood Main 13 10 2 8 0 81.3 ft2 0 0.23 0.6 0 2 N Exterior Concrete Block - Int Insul Main 4.1 38 7 10 0 385.8 ft2 0 0 0.6 0 3 E Exterior Frame - Wood Main 13 4 6 10 0 45.0 ft2 0 0.23 0.6 0 4 E Exterior Concrete Block - Int Insul Main 4.1 28 6 10 0 285.0 ft2 0 0 0.6 0 5 S Exterior Frame - Wood Main 13 6 9 8 0 54.0 ft2 0 0.23 0.6 0 6 S Exterior Concrete Block - Int Insul Main 4.1 50 3 8 0 402.0 ft2 0 0 0.6 0 7 SW Exterior Frame - Wood Main 13 3 10 10 0 38.3 ft2 0 0.23 0.6 0 8 SW Exterior Concrete Block - Int Insul Main 4.1 0 5 10 0 4.2 ft2 0 0 0.6 0 9 W Exterior Frame - Wood Main 13 18 11 10 0 189.2 ft2 0 0.23 0.6 0 10 W Exterior Concrete Block - Int Insul Main 4.1 37 8 8 0 301.3 ft2 0 0 0.6 0 11 - Garage Frame - Wood Main 13 26 0 8 0 208.0 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated Main None .25 3 6 8 20 ft2 2 - Wood - Main None .25 2 8 6 8 . 17.8 f1:2 3 S Insulated Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 23 ft 0 in 0 ft 9 in Drapes/blinds None 2 N 2 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 3 E 3 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft2 7 ft 8 in 0 ft 6 in None None 4 E 4 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 7 ft 8 in 2 ft 10 in None None 5 E 4 Vinyl Low-E Double Yes 0.33 0.21 N 30.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 6 E 4 Vinyl Low-E Double Yes 0.33 0.21 N 36.0 ft2 1 ft 0 in 2 ft 10 in Drapes/blinds Exterior 5 7 S 6 Vinyl Low-E Double Yes 0.33 0.23 N 9.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 8 S 6 Vinyl Low-E Double Yes 0.33 0.23 N 15.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 9 SW 7 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft2 11 ft 0 in 0 ft 4 in Drapes/blinds Exterior 5 10 W 9 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 9 ft 4 in 0 ft 9 in Drapes/blinds None 11 W 9 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft2 6 ft 8 in 0 ft 4 in Drapes/blinds Exterior 5 12 W 9 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 9 ft 4 in 0 ft 4 in Drapes/blinds Exterior 5 13 W 10 Vinyl Low-E Double Yes 0.33 0.23 N 45.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 3/23/2021 8:59 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORMA405-2020 INPUT SUMMARY CHECKLIST RFPART GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 617 ft2 617 ft2 64 ft 9 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 2390.9 131.17 246.26 .1324 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS # - — Supply---- Location R-Value Area -- Return ---- Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 456.2 ft Main 114.05 Default Leakage Main (Default) (Default) 1 1 3/23/2021 8:59 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORMb405-2020 INPUT SUMMARY CI-IFCKI IST RFPART TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan HeatinJan r 1 Feb [X] Feb Mar Mar Apr E Apr f Ma I May Jun n Jun Jul rj Jul Au f Aug Se SeP ri Oct Oct Nov Nov Dec Dec Ventin Jan [[[[ ]]]] Feb Mar [X] A r [ Ma [[[ jjj Jun Jul [ Au Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 3/23/2021 8:59 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY- PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient :the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.21 c. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.70 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 8319 Amalfi Circle, Fort Pierce, FL, 34951 New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1378.30 ft2 b. Frame - Wood, Exterior R=13..0 407.83 ft2 1 c. Frame.- Wood, Adjacent R=13.0 208.00 ft2 4 d. N/A R= ft2 No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.6 2277.00 ft2 2277 b. Knee Wall (Vented) R=19.0 80.00 ft2 Area c. N/A R= ft2 154.00 ft2 12. Ducts, location &.insulation level R ft2 a. Sup: Attic, Ret' Main, AH: Main 6 456.2 66.00 ft2 13. Cooling -systems . kBtu/hr Efficiency 35.56 ft2 a. Central Unit 35.0 SEER:16.00 18.33 ft2 5.043 ft. 0.292 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ft2 b. N/A R= ft2 c. N/A R= ft2 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code corrinUanifeatures. Builder Signatur Date: Address of New Home: City/FL Zip: kBtu/hr Efficiency 34.6 HSPF:8.50 Cap: 40 gallons EF: 0.94 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/23/2021 8:59 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1