DESIGN PRESSURE CALCULATIONS
Property Information Owner:Carrie Mathias Address:425 S Naranja Ave Port Saint Lucie, FL 34983 Building Information Wind Zone:160 MPH. Exposure Category:C Minimum Building Dimension:30 ft. Mean Roof Height:12 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 73 61 7 31.0 -39.9 2 End 73 61 7 31.0 -39.9 3 End 73 61 7 31.0 -39.9 4 End 37 61 7 32.5 -42.9 5 End 144 80 7 29.0 -35.8 6 End 97 61 7 30.4 -38.7 7 End 73 61 7 31.0 -39.9 8 End 48 25 7 33.5 -44.8 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1