Loading...
HomeMy WebLinkAboutAPPROVED, Design Pressure Report (Uhland) - Master Craft Aluminum ProductsProperty Information Owner:Uhland Address:5782 Travelers Way Ft Pierce, Fl 34982 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 94 91 7 28.7 -31.5 2 Int 74 62 7 30.0 -32.8 3 Int 53 57 7 30.9 -33.7 4 Int 26 39 7 32.5 -35.2 5 Int 26 51 7 32.5 -35.2 6 Int 26 51 7 32.5 -35.2 7 Int 112 57 7 29.3 -32.1 8 End 324 89.5 7 25.7 -30.0 9 End 126 89 7 28.1 -34.8 10 Int 53 39 7 31.7 -34.5 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1