Loading...
HomeMy WebLinkAboutROOF FASTENING REQUIREMENTS JOSEPH W. SCHULKE, P.E. JODAH B. BITTLE, P.E. WILLIAM P. STODDARD, Ph.D., P.E. S CHULKE , B ITTLE & S TODDARD, L.L.C. CIVIL & STRUCTURAL ENGINEERING · LAND PLANNING · ENVIRONMENTAL PERMITTING 1717 INDIAN RIVER BLVD., SUITE 201 VERO BEACH, FLORIDA 32960 TEL 772 / 770-9622 FAX 772 / 770-9496 EMAIIL info@sbsengineers.com May 27, 2021 Mr. Douglas Harvey Building Supervisor / Building official St. Lucie County 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Flat Roof Fastening Requirements 4235 N. Highway A1A, Hutchinson Island, FL 34949 Permit # Dear Mr. Harvey: The roof areas for the building located at 4235 N. Highway A1A, will be covered in accordance with Florida Building Product Approval FL1654-R27. Component and cladding design wind pressures for the corner, perimeter, and interior zones for the roof section were calculated per ASCE 7-10 “Minimum Design Loads for Buildings and Other Structures” using the following criteria: Ultimate Design Wind Speed (3 second gust), Vult = 161 mph Nominal Design Wind Speed (3 second gust), Vasd = 125 mph Exposure Category D Risk Category II Enclosed Building Internal Pressure Coefficient, GCpi +/-0.18 Mean Roof Height, h =10.0 ft Roof Slope 0:12 Directionality Factor, Kd = 0.85 Effective Area = less than 10 sf The resultant component and cladding ultimate design uplift pressures are: Zone 1 -109.3 psf Zone 1’ -62.7 psf Zone 2 -144.2 psf Zone 3 -196.5 psf DocuSign Envelope ID: 13C328B5-8F5E-4975-A46F-50AF79353674 Page 2 of 3 The resultant component and cladding nominal design uplift pressures are: Zone 1 -65.6 psf Zone 1’ -37.6 psf Zone 2 -86.5 psf Zone 3 -117.9 psf Attached is a sketch showing the locations of Zones 1, 1’, 2 & 3 of the roof. On the attached product approval appendix 1, page 17 of 94 specifies allowable nominal design maximum pressures for new or re-roof wood decks using: system W-60 w/ Tapered ISO (H Shield) insulation and SBS-SA base ply. (maximum design pressure -67.5 psf). Zone 1 & 1’ design pressures meet as specified and shall be fastened in accordance with the Florida Product Approval FL1654-R27. The design pressures in Zone 2 exceeds the design limitations of Florida Product Approval FL1654-R27. Increased fastening density in this zone was calculated in accordance with RAS 117. The following are the requirements for the base sheet fastening to satisfy the component and cladding design pressures for this specific job: 1 fastener = 1 fastener 1.3 sf X sf 67.5 psf 86.5 psf 1 fastener = 1 fastener 1.3 sf(67.5 psf) X sf(86.5 psf) 1 fastener = 1 fastener 87.75 lbs X sf(86.5 psf) X =1.01 sf Zone 2 = 1 fastener per 1.01 sf DocuSign Envelope ID: 13C328B5-8F5E-4975-A46F-50AF79353674 Page 3 of 3 The design pressures in Zone 3 exceeds the design limitations of Florida Product Approval FL1654-R27. Increased fastening density in this zone was calculated in accordance with RAS 117. The following are the requirements for the base sheet fastening to satisfy the component and cladding design pressures for this specific job: 1 fastener = 1 fastener 1.3 sf X sf 67.5 psf 117.9 psf 1 fastener = 1 fastener 1.3 sf(67.5 psf) X sf(117.9 psf) 1 fastener = 1 fastener 87.75 lbs X sf(117.9 psf) X =0.74 sf Zone 3 = 1 fastener per 0.74 sf If you have any questions or require additional information, please feel free to contact me. Sincerely, Date: William P. Stoddard, Ph.D., P.E. FL. Reg. No. 57605 cc: HannaBri Services, Inc. DocuSign Envelope ID: 13C328B5-8F5E-4975-A46F-50AF79353674 5/27/2021