DESIGN PRESSURE CALCULATIONS
"Building Our Quality Reputation One Customer At A Time" SCC131150472 Property Wom F Building Information wner': --- - JUAN-GALLEGOS - -- ---Wind one: 170 MPH, Address: 7401 PENNY LN Exposure Category: C FORT PIERCE, FL 34951 Minimum Building Dimension: 24 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations m- Opening Location Device Device Max Positive Max Negative Number Zone Width (in)Height(in) LDevicc vation ($) Pressure {psl) Pressure {psi 1 Int 72 49 7 35.6 -38.8 2 Int 72 36 7 36.4 -39.6 3 End 72 - 37 7 36.3 -47.6 4 End 35 36 7 37.8 -50.6 5 Int 35 36 7 37.8 -41.0 6 End 35 36 7 37.8 -50.6 7 End 72 36 7 36.4 47.7 8 Int 35 24 7 37.8 -41.0 9 End 35 49 7 37.4 -49.7 10 End 110 61 7 34.0 -43.0 -- Prepared in accordance with. dSCE 7-16 Chapter 30. Wind Goads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of I