HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSProperty Information
Owner:Jamilah McPherson
Address:2901 Sheraton BLVD
Fort Pierce, FL 34946
Building Information
Wind Zone:160 MPH.
Exposure Category:D
Minimum Building Dimension:35 ft.
Mean Roof Height:10 ft.
Risk Category:II
Design Pressure Calculations
Opening
Number
Location
Zone
Device
Width (in)
Device
Height (in)
Device
Elevation (ft)
Max Positive
Pressure (psf)
Max Negative
Pressure (psf)
1 End 74 50 7 38.1 -49.4
2 End 80 63 7 37.3 -47.8
3 End 54 26 7 40.6 -54.4
4 End 37 38 7 40.6 -54.4
5 End 37 38 7 40.6 -54.4
6 End 74 80 7 36.9 -46.9
7 End 37 38 7 40.6 -54.4
8 End 35 44 7 40.5 -54.1
9 End 37 38 7 40.6 -54.4
10 End 26 38 7 40.6 -54.4
11 End 37 38 7 40.6 -54.4
12 End 54 38 7 39.7 -52.5
13 End 54 38 7 39.7 -52.5
Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code.