DESIGN PRESSURE CALCULATIONS
Property Information Owner:Jamilah McPherson Address:2901 Sheraton BLVD Fort Pierce, FL 34946 Building Information Wind Zone:160 MPH. Exposure Category:D Minimum Building Dimension:35 ft. Mean Roof Height:10 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 74 50 7 38.1 -49.4 2 End 80 63 7 37.3 -47.8 3 End 54 26 7 40.6 -54.4 4 End 37 38 7 40.6 -54.4 5 End 37 38 7 40.6 -54.4 6 End 74 80 7 36.9 -46.9 7 End 37 38 7 40.6 -54.4 8 End 35 44 7 40.5 -54.1 9 End 37 38 7 40.6 -54.4 10 End 26 38 7 40.6 -54.4 11 End 37 38 7 40.6 -54.4 12 End 54 38 7 39.7 -52.5 13 End 54 38 7 39.7 -52.5 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1