DESIGN PRESSURE CALCULATIONS
Property Information Building Information Owner: John DiFrancesco Wind Zone: 160 MPH. Address: 4712 Sunset Blvd Exposure Category: B Ft Pierce,F134982 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: 11 Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 25 62 7 32.3 -35.1 2 Int 25 62 7 32.3 -35.1 3 Int 25 62 7 32.3 -35.1 4 Int 25 62 7 32.3 -35.1 5 Int '25 62 7 32.3 -35.1 6 Int 25 62 7 32.3 -35.1 7 Int 25 62 7 32.3 -35.1 8 --- Int 25 49 —�— -7 - 32.5 -35.2 9 Int 25 49 7 32.5 -35.2 10 Int 25 25 7 32.5 -35.2 11 Int 25 62 7 32.3 _ -35.1 12 Int 25 62 7 �32.3 -35.1 13 - Int 25 62 7 32.3 -35.1 Qto Copy. Prepared in accordance with:ASCE 746.Chapter 30.Wind Loads-Components and Cladding.7th Edition(2020)Florida Building Cade. Page 1 of 1