Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED 12-26B G Carlton GL PR I
Metal roofing and underlayment intstalled per Product Approval as shown on sheet I over COX decking - see roof sheeting 5/ d" thick cut coral coral finished stucco bands finished stucco bands RIGHT ELEVATION SCALE: 1/4" = 1'-0" Metal roofing and underlayment intstalled per Product Approval as shown on sheet I over CDX decking - see roof sheeting attachment diagram on roof plan. 12 4 1 SLOPE Truss mfg to provide level - return to be I" short of wall Aluminum Drip Edge t Fascia 2" x 4" Sub -Fascia Kaycan full o vent vinyl soffit installe per product approval form on sheet I. a01 2 " \�1" x 4" nailer attached to level return with (2) Sd ring shank nails with min. 1.5" penetration into soffit framing TYPICAL SOFFIT DETAIL NTS Metal roofing and underlayment intstalled per Product Approval - ..L.,,,,,,. .,,.. ..Lee+ I .,..a., rill! .1a.,6,,.... - - ... P .,Loa+,,,... ;;.7i v 1.1114-N L.ut L.L/1 cal SLUCCO On Ligpiczv conCrefLef finished stucco bands block construction 12" 2" ° H 5/8" thick x 8"w cut H 5/8" thick x 8"w cut 3 coral finished stucco bands coral finished stucco bands 3 5/8" thick light textured stucco on typical concrete block construction '-0" = Fin. Floor Gara a Finished Floor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -0-4 A.F.F. LEFT ELEVATION SCALE: 1/4" = 1'-0" Product Approval Submittal Affidavit Opening Schedule Swing Doors. Overhead Doors. Sliding Doors, Windows E Skylights Opening NOA/FL Product Model Manufacturer Glass Attachment method TEST Expiration Design Pressure Type NUMBER Date of Approved Tests 1.2.3 FLU 239A Single Hun g g SH-1�00A PGT 5/16" 1/4" dia, tapcons w/ min. 13/8" penetration to be spaced per product approval. Contractor shall adhere to + 65.0/-80.0 PS 44 Impact min. edge distances specified in Product approval A 20-1005.08 Overhead Model 824/811 18'-2" max. width DAB nets x uc to concrete blockwith i i e callwith I) u5 bar Vert. using 3/8' x L' Haiti HLC Sleeve anchors at 8' oc. th 1.25' din. washers uKh min. 4" edge distance. Install track to buck 3-21-22 +40.0/-44.0 PSF Garage Door g Ili'-O" max height g Door Com an ng (D 5/IL' x 1 5/8" full thread lag screws n each bracket maintaining min a 1.5' edge distance - GC to stnctlg adhere to product approval rovide 1/I6' u nut ua ar on railer tw B F L 4 15213.1 Fiberglass Smooth Plast-Pro 1/4" dia. tapcon with min 1.25" embedment at 6" max from corners and 14.5" o.c. max, thereafter in jambs. +65.0/-10.0 Fiberglass Sliding Glass Series 110 1" nom I/4" dia, tapcons w/ min. 13/4" penetration to be spaced per product approval. Contractor shall adhere to + 60.0 PSF Door Type G 5 A min. 2 1/2" edge distances specified in Product approval - Product NOA/FL Model u Manufacturer Attachment Method TEST Design Pressure NUMBER Date of Approved Tests For CMU use (2) 1/4" x 2 3/4" tapcons with min 1 1/4" embedment Mullions FLU 15353.8 CM-18531 vertical mullion Mi Windows and doors penetration into each Mull Clip. Attach mull to clip using (4) 410 x 1.25" self tapping screws per clip as shown in product approval. + 118.9 PSF _ Roof F L 4 33818.2 5V Crimp p Metal Roofing Gulf Coast Supply 26 a. 5v crimp metal roofing attached to plywood deck using 49-15 x 1.5" Hw1� wood screws with self sealing washer at 12" o.c. max spacing -per System Roof Zone 1/2E/2R: and manufacturing g no. 5V-Type I for max pressure -94.25 psf. Install per system V type 2 for max. pressure of -131.0 psf. Fasteners shall be installed through underla - - g4.25 PSF ment and attached to/through I wood per sheeting attachment detail on room plan. Plywood to be 19/32 2P xw! 2N/3/3E/3R: -131.0 PSF Underlay FLU 20814.1 DuPont Protec 140 DuPont Install two layers of Tyvek horizontally in shingle style fashion using 4" and 6" overlaps. Install using I" dia. metal or plastic cap nails at 12" o.c. along Tyvek course and end laps an a single row 24" o.c. along middle line of the field I.A.W. the product approval installation instructions. Stagger top layer using 24" undercourse strip parallel to eave edge and cover with full sheet. Overlap successive sheets by 26" I.A.W. product approval installation instructicris. Siding Stucco on Block Soffit FLU 16503.1 „ 12 Tripple 4 Install using " x T battens attached to wall using 3/16" dia. with I" min. embedment Into wall. Attach Soffit channel to wall us1ng Full-O-Vent Single Kaycan LTD 0.09�" dia. x 1.5" T-nails at 12" o.c, per detail C in P.A. Install X ± 55.6 PSF SPAN VINYL S_0FFI channel to bottom of fascia usin staples into soffit and same T-nails I have reviewed the above and approved It by mg seal below. ( Architect or Engineer of Record ) 2" x 4" top plate 4" concrete slab with fibermesh OR 6 x6 410/10 WWM on (. mil Visqueen over clean compacted termite treated fill base -board 12" ).H REAR ELEVATION SCALE: 1/4" = 1'-0" Metal roofing and underlayment intstalled per Product Approval as shown on sheet I over COX decking - see roof sheeting attachment diagram on roof plan. 12 4 1 SLOPE 171=71171=711MLM mj uraw 5/8" thick light textured stucco on typical concrete block construction FRONT ELEVATION 1/2" drywall ceiling on truss bottom cord 1/2" drywall on 2" x 4" studs at 16" o.c. 2" x 4" P.T. bottom plate Interior Non -Bearing Partition nts ELEVATION NOTES: - RETURN ALL STUCCO BANDS TO WINDOW OR DOOR. /8" thick X 8"w cut oral finished stucco bands 1/8" Thick cut coral stucco over paper backed wire lath nailed to substrate through one layer of 15 lb felt using 8d nails. Substrate to be 19/32" COX Plywood nailed at 6" o.c. in field and edges with IOd ring shank galvanized nails into truss webbing. SCALE: 1/4" = 1'-0" 5/8" thick x 8"w cut coral finished stucco bands Finish Columns with 5/8" thick cut coral finished stucco bands PERMITTING INFORMATION (FORM 100) R 2R I. 3E 2N 2N Florida Building Code Residential: 1TH Edition and ASCE 1-10 for Wind Loading Building Design is: Enclosed Risk Category II Wind Speed: 145 mph ultimate Mean Roof Height: IS' -a" Roof Pitch: 4:12 110-200) ` 2E _ 3E Internal Pressure CoCoee i�cient: ± 0.18 3EI'LL Subjectability to damage from: Weathering: Negligible Termites: Vero Heav4 2 �LLL" 2E 5 Width of Roof End Zone: 4`0" 3 '� 3E 4 Wind Exposure Classification: C Adjustment factor for Exposure Height Using Allowable Stress Design and Load Combination per ASCE 1-10 Section 2.4 DL+LL; DL+0.4WL; 0.6DL+O.6WL 5 Exp Height Adj Factor: 1.00 x Load Combo Factor 0.4 = 0.4 applied below GABLE12 TO ROOFFROM GABLE ROOF Components t Cladding Wind Pressure: 2E +15.O/-39.0 psf Zone: �N, Zone: 2R, 3E +15.0/-51.0 psf 2R Zone: 3R +15.0/-49.0 psf I 3 2E 2E HIP ROOF Components t Cladding Wind Pressure: 3 Zone: I +18.0/-31.0 psf 2R Zone: 2E/SE +18.0/-41.0 psf 2E Zone: 2R +18.0/-53.0 psf 3 - 12R Components t Cladding Wall End Zone Width: 3'-O" `LLL 2E 5 4 3 WALL Components t Cladding Wind Pressure: Zone 4: +23.0/-25.0 psf 4 Zone 5: +23.0/-31.0 psf Components t Cladding Wind Pressure (NET) on Garage Door: Zone 5: +32.0/-41.0 psf YIP ROOF 2.12 Shear Walls Considered for Structure? Yes 0 8.12 PITCH Continuous Load Path Provided? Yes O = Roof Zone I Are Components an Cladding Details Provided? Yes Walls Zone 4 Minimum Soil Bearing Pressure: 2,500 psi, Presumptive: X By Test: psi This Building Shall Have the Following: END p am Roo Goon 2E/2R APPROVED SHUTTERS: IMPACT GLASS: X BOTH: NEITHER: Walls Zone 5 CORNER ZONE = Roof Zones 3/3E/3R ROOF LIVE LOAD: 20 psf ROOF DEAD LOAD: 15 psf Attic w/out storage: 10 psf FLOOR LIVE LOAD: _±0___ psf FLOOR DEAD LOAD: 10 sf Attic with storage: 20 sf Roof Zone 2N 4LL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING DCCURS BETWEEN THE BUYER AND WY>\NE BUILDINGS CORD 4ND WILL CONTINUE FOR ONE YEAR FROM THAT DATE Digitally signed by / Daniel R. Braden Date:2021.06.10 14:50:05-04'00' LL Lis w< N 01 W o O LU = O .zW00cv°o <w< �� U -� ' Q- 000 L 0 r r < Z N N I-- #* I ~ O aj U ULU 1- LLI Q1 iaj U (a IL N 1L for < �D a` 3 as SHEET NO: I. OF S. JOB NUMBER: 12-2� B C: R. BRAD, O o o O o AR 977770 O ° ,nO PANEL "A" Poles BR Load Wire Description circa circa Description Wire Load BR Poles 1 20 1.2 kw #12 Refrigerator I Range #f. 12.0 kw 50 2 1 20 1.2 kw #12 Clothes Washer 3 1 20 1.5 kw #12 Kitchen S.A.C. 5 f. Driier #10 5.0 kw 30 2 1 20 1.5 kw #12 Kitchen S.A.C. 1 8 1 20 #12 Bathroom Recepts 4 10 Air Cond sor u10 5.0 kw 30 2 1 20 1.2 kw #12 Dishwasher 11 12 1 20 1.2 kw #12 Microwave 13 14 Air Handl r #10 5.0 kw 30 2 1 15 #14 General Lighting 15 I. I 15 #14 General Lighting IT 18 WH u10 5.0 kw 25 2 1 15 #14 General Lighting 19 20 I 15 #14 General Lighting 21 22 GDO #12 0.81 KW 20 1 1 15 #14 General Lighting 23 24 Spare Spare 25 2G Spare Spare 21 28 Spare Spare 29 30 Spare PANEL "A" LOAD CALCULATION SHEET Load Description Qt . Watts Total(Watts) General Lighting (3 watts sq. ft.) Small Appliance Circuit(s) Range Refrigerator Microwave Dish Washer Clothes Washer Clothes Dryer Water Heater Garage Door Opener 1135 3 5.205 2 1,500 3,000 1 12,000 12,000 1 1,200 1,200 1 1,500 1,500 1 1,200 1,200 1 1,200 1,200 1 5,000 5,000 1 4,500 4,500 I 1 810 1 810 Total Watts 35.615 First 10000 Watts 9100% 1 10,000 10,000 Remainder 25.615 °40% 1 0 10.246 Electric Heat or A/C 10,000 e65% 1 10,000 10,000 Calculated Load Watts 30.246 Voltage 240 Calculated Wattage Divided bg Voltage = Total Amps 126.02 Panel Size Required = 150 Amps Electricdl Sgmbol Legend S Single Pole Switch ® Recessed Can Light S3 Double Pole Switch ® Egeball Recessed P Push Button Switch Exhaust Fan Duplex Outlet Ceiling Mounted Light Special Receptacle Wall Mounted Light =-9 Waterproof ground fault circuit Light with Pull Chain (attic) ® Floor Duplex Outlet © Computer Connection Jack 0 Carbon Monoxide Detector '1& Flood Light TQ Thermostat m Electrical Panel ® Central Vac 8 Electrical Meter ® Smoke Detector Ceiling fan ® Television Jack ❑ 1 Telephone Jack AC DISC A/C Disconnect ® 1 x 4 Florescent Light ® 12 x 4 Florescent Light ® Speaker Hook -Up FB = JUNCTION BOX TO SUPPORT A FAN O = THERMOSTAT LOCATION B/A = BALANCED AIR Vent-tbru --- Soffit FIELD VERIFY SERVICE LOCATION RESPECIVE TO PANEL LOCATION AND USE APPROPRIATE RISER BELOW A/C disc. A/C disc. 42/0 AL SER Cable (3) #1 THHN Copper With UI Grnd 2" PVC Schedule 40 conduit 2" PVC Schedule 45M0 40 conduit sleeve AMP MCB into attic MCB PANEL AHU PANEL AHU 200a rated 200a rated meter can O meter can O METER METER Intersystem bonding Intersystem bonding 2" PVC ( FPL)-� Termination point 2" PVC ( FPL Termination point schedule 80 schedule 80 2" rigid service FPL 2" rigid service FPL GEC Bare 44 c per wire to (2) 8'-(9 Galvanzied GEC Bare ub c� per wire to (2) 8'-Galvanzied ground rods ground rods ELECTRICAL RISER ALTERNATE SERVICE ELECT. RISER - Contractor shall use AL-CU Landing lugs. NTS - Contractor shall use AL-CU Landing lugs. NTS - Contractor shall torque lugs I.A.W. - Contractor shall torque lugs I.A.W. manufacturers recommendations which manufacturers recommendations which shall be verified prior to construction shall be verified prior to construction - Verify AIC/KIC Rating prior to ordering equipment - Verify AIC/KIC Rating prior to ordering equipment ELECTRIC NOTES: I. Use copper wire only from panel to devices 2. Provide and wire all required smoke 4 Carbon Monoxide detectors. 3. Contractor to verify location of electrical service and provider. 4. ALL bath and kitchen receptacles to be GFCI protected S. ALL exterior outlets to be WP/GFCI protected. 6. Recessed cans to be installed per NFPA requirements. 1. Tamper resistant AFCI receptacles are required in ALL rooms. 8. A/C Return Air Balance Must comply w/ FBC RM1602 9. A/C Refricierant lines that are run thru slabs must be sleeved in -PVC 10. ALL A/C Equipment shall comply with energy calculation 11. All work shall be performed bg a licensed electrical contractor, the completed syLstem shall be fullg operative. 12. Contractor shall pay for all fees, permits, testing, and inspections including blower testing where required. 13. All work shall be coordinated with other trades to avoid interference with the progress of construction. 14. All required insurance shall be provided for protection against the public liability and property damage for the duration of the work. 15. Contractor shall guarantee all materials and workmanship free of defects for a period of not less than two years from the date of acceptance or certificate of occupancy, or one year from closing sale of house. Correction of defects shall be completed without additional charge and shall include replacements or repair of any other phase of installation that may have been damaged. 16. It is not the intent of these plans to show every minor detail of construction. The contractor shall furnish and install all items for a complete electrical system and provide all the requirements necessary for the equipment to be placed in proper working order. 1-1. All work shall be done in accordance with the N.E.C. and shall comply with all local codes and ordinances, and shall meet all standard requirements of the local electric utility and telephone company. 18. The electrical system shall be completely and effectively grounded as required bg the latest edition of the N.E.C. 19. All material shall be new and shall bear underwriters' labels where applicable. 20. All equipment and panel sizes shall be verified before ordering. The contractor shall provide circuit routings to suit the job conditions. 21. Furnish and install all fixtures as called for on the plans or as selected bg others. 22. All raceways and pipes placed in or through any concrete slab shall be spaced a minimum of three diameters of the largest conduit or pipe from any other service. 23. All exposed wire below 9'-1" shall be installed in metal EMT conduit. 24. Dryer Vents to be installed per FBC RM1502 I Exhaust Duct Thru Soffit -4" Exhaust Duct Thru W a I I WP GFCI Install oulet under disc. " H B not show'f n or clarity Vent thru v7 0 Meter T L OPTIONAL PATIO/SLAB ,'Covered Porch`,, MASTER BEDROOM WP GFCI \ 1 1 �$ IH 1TV1 I - - _ Smoke / Carbon G R A T i Monoxide Detector O M / Combo ol S I C Li - I I � I �I CLOSE I =E) I II I II DINING GFCI I I ROOM A�l I_ FC \\ \ I gm GFCI GFCI I / N � KITCHEN Smoke /Carbon L - Monoxide Detector ((JJ)) I '17-0mTo - -�+k:F I �24" 3'-2" 3'-2" GFCI 42" GFCI ll W.H. I 22' x 54' I, Attic Access 1 Nth light I �\ L_U--- 150 AMR 1C Optional P a n e l Pull chain panel location \ light in attic 42" GFCI GARAGE Garage Door -Opener ---------------- I I I I I I I I I I I I I I I I I I I I I I ELECTRICAL i PLAN 3l �^I j B T 5o CFM F N R-0 ;j �W , o Centel � C SE \ONE t ®s BEDROOM TV / WP GFCI ri 'COo��H� ' I SCALE: 1/4" = 1'-0" Attic Venting Calculations FBC 2309.1 Total Attic Space = 2124 sq, ft, Venting Ratio 1/1S0 = 14.1� sq, ft, required Provide A Continuous Vented Soffit Post Light with Photo cell I H.B. Exhaust Duc Thru Soffi Wire For Front Post Light Digitally signed by Daniel R. Braden e.. Date: 2021.06.10 14:52:52-04'00' N W o O LU p .zWLnO vo < �C4 U - (L <aoao L IF IF < Z 00 N #* I N ~ aj U >- I- W Ql Q) is '- �D 3 SHEET NO: E-1 OF S. JOB NUMBER: 12-2�B re" ° ° v R. 8���� � 0.1 o° AR 977770 o� p °��