HomeMy WebLinkAboutProject Information ■ LUCi RECEIVED
FILE COPY JUN 2 b 2021
St.Lucie County
Section A(General Information) Permitting
Master Permit No. Process No.
Contractors Name: K� 0 ) License# Cw I✓�S_6'
Job-Address r v �l/UQ'd� �� DEL .3 341791
ROOF CATEGORY
0 Low Slope 13 Mechanically Fastened Tile 0 Mortar/Adhesive Set Tiles
•Asphaltic Shingles Metal Panel/Shingles Mood Shingles/Shakes
0 Prescriptive BUR-RAS 150
ROOF ROOF TYPE. /
0 e New roof 0 Repair 0 Maintenance /roofing ❑Recovering
-ROOF SYSTEM INFORMATION
Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) Total(SF)
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all, levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets.
o ST. L UCIE WORKS
l pz wo ° ^
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code-Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Required Sections of Attachments Required
Roof System the Permit Application See List Below
Form
Low Slope Application A,B,C 1,2,3 4,5,6,7
Prescriptive BUR-RAS 150 A,B,C 2,4,5,6,7
Asphaltic Shingles A,B,D 1 RA5 6,7
Concrete or Clay Tile A,B,D,E i;234,5;67
Metal Roofs A,B,D
Wood Shingles and A,B,D 1,2,45,6;7
Shakes
Other As Applicable 12;34,56,7
ATTACHMENTS REQUIRED As Applicable):
1. Fire Directory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128
4. Other Component of Product Approval
S. Municipal Permit Application
6. Owners Notification for Roofing Considerations(Reroofing Only)
7. Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18,2021
y '
LUCIE WORKS
Section C(Low Slope Roof) Surfacing:
Fill in spec\ed,oicdoen
ssembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
manufactuZone 1'• "oc @ Lap,#Rows 6 °oc
(If a compot used,identify as"NA") Zone 1' "oc @ Lap,#Rows 0—,. a W
System Ma ++
Zone 2:�. oc @Lap,#Rows 0; oc •
Zone 3:_..."oc @Lap,#Rows—
Number of Fasteners Pe nsulation Board:
Design Wires,From S 128 Or Calculations: Zone V, Zone Zone 2- Zone 3:
Zone 1': Zone 2. Zone 3: IllustrateCompo ents Noted and Details as Applicable:
Max. Desigre,from the sp ific product approval. Woodblockin Gutter, Edge Termination, Stripping,
system: Flashing, 'C tinuous Cleat, Cant Strip, Base Flashing,
Counterfl hing,Coping,Etc.,
Deck: Indicat Mean Roof Height,Parapet Height, Height of Base
Type: Flash' g,Component Material,Material'Thickness,Fastener
Typ ,Fastener Spacing or Submit Manufacturers Details that
Gauge Thickness: C mply with RAS 111 and Chapter 16..
Slope:
Anchor/Base Sheet&No.df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material: FT.
Insulation Base Layer:
Base Insultation Size and Thickness: Parapet
Base Insulation Fastener/Bonding Material: Height
Top Insulation Layer:
Top Insulation Size and Thickness: FT.
Top Insulation Fastener/Bonding Mat vial:
Mean
Base Sheet(s)&No.of Ply(s): Roof
Base Sheet Fastener/Bondingtrial: Height
1
Ply Sheet(s)'&No.of Ply(s):
Ply Sheet Fastener/Bondi g Material:
Top Ply:
Top Ply Fastener onding Material:
ST LUCIE WORKS
Section D (Steep Slope Roof System) LLc
Roof System Manufacturer:
Notice of Acceptance Number:
Minimum Design`Wind Pressures,If Applicable(From RAS 127 or Ca I, ull tions): q `39
Zone 1. Lone 2e:Qzone 2n:_Zone 2r 1 ozone 3e3 one.3r:
Deck T
yam: . p� 2 1 (,/00
Type::Undei'Caymen
Rpe..
'f 2
Insulation: ' Q✓�`�
Fire Barrier: �/�jy -
Rid` a Verifdaiaor?f Fastener T �e S.4dh c
�S yp p 9 X 1 W 0�1- Lb J 0
Adhesive Type; G.Al
Type,Cap:Sheet.
SUlean Of Height: Roof Covering:
Type B;Size Drip;
- Edge.
Z
Section E(Tile Calculations)
For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mf.If the Mf values
are greater than or equal to the Mrvalues,for each area of the roof,then the tile attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: x — _�.».Mg:, =Md. Product Approval M
(Zone 2e: xX - _ :—Mg:- -M� Product Approval f
(Zone 2n: x X - _�:.-Mg: ='Mm; Product Approv Mf
(Zone 2r: X=16 = _ =Mg: =Mrlr Product Appr al Mf
(Zone 3e: x71 _ __j.—Mg =M Product roval Mf
(Zone 3r: x k — a-:54- =.M� Produ pproval Mf
Method 2"Simplified Tile Calculations PerTa Below"
Required Mo ent of Resistance(Mr)From Table Below Product Appr al Mf
Mr required Moment Resistance*
Mean Roof Heigh Roof Slope 15' 20' 25' 30' 40'
2:12 34.4 36.5 38 39.7 42.2 .
3:12 32.2 34.4 6.0 37.4 39.8
4:12 30.4 32.2 33.8 35.1 37.3
5:12 28.4 30.1 31.6 32.8 34.9
6:12 26.4 28.0 29.4 30.5 32.4
7:12 � 24.4 25.9 27.1 28.2 30.0
*Must be used in conjunction with a ' t of moment ba d the systems
•For Uplift based tile systems use Meth d 34o�,t,n
Compar the values for F'with the values for Fr If the F'values are greater than or
equal to the Fr values,for each a the tile attachment method is acceptable.
Based Tile Calculations Per RAS 12T
(Zone 1: x L =x W:= os r =Fri Product Approval F'
(Zone 2e: x L =x W:= cos r =Frze Product Approval F'
(Zone 2n: x L =x W:= cos r =F�z" Product Approval F'
(Zone 2r: x L =x W:= c r =F�z� Product Approval F'
(Zone 3e: x L =x W:= cos =F�3e Product Approval F'
(Zone 3r: x L =x W:= cos r =Far Product Approval F'
Whereto Obtain In rmation
Description Symbol Where to find
Design Pressure Zones 1,2e,2n,2r,3e,3r From a licable table in RAS 127 or by an engineering analysis
prepared PE based on ASCE 7
Mean Roof Height H Job Site
Roof Slope 0 Job Site
Aerodynamic Multiplier a Product Approva
Restoring Moment due to Gravity Me Product Approval
Attachment Resistance Mf Product Approval
Required Moment Resistance Mg Calculated
Minimum Attachment Resistance F' Product Approval
Required Uplift Resistance F, Calculated
Average Tile Weight W Product Approval
Tile Dimensions L=length W=width Product Approval
All calculations must be submitted to the building official at the time of permit application.