Loading...
HomeMy WebLinkAboutTruss0 I N N N 21'-4" 14'—O" 39'-9' TNrs is A TRIGS PIAmQ(T PLAN ITS MENDED M Am IN'nE D(STALLATM)t OF TRISSES. ENaDE= TRUSS DRAVDW AND ARpRCOCII "SIPMCEM THM D0mwff. ESIE 6 UI RAN DE rn rr.r.tir TRUSS ESTA DZ7 MO PARA ATUDAR Q( LA UWALACUM DE TR=ES, LDS DIDO.US T ARMTECRIPa BE DKOCERCA DE Di[OMM ='ERMC FSTE DDMNEX O. tam P21MMT rta®1 c 0MMM ALL RD2 flltll. E PAiiEaa 1�71ar IIAA Ma m i;;tm aR L M Reg Tames smlorr OMO" or TIQ W la]t VLL ADr AL�IaD wnI i Tamtmt Af{TBVN. n � M M WM13 N E AII AMY MF TO fNatf THE 181R ow >�la b GMaM =aiE Mlr lG3 6 A/HJm Ret T AT Gfi411R1 maR1CIpR R A/We1, Da: Da® >Y M T main Ata MaT E 1RMZ Mal RI vWx luum TIE Taa=7 AM fR A a®1 TO AM PaWn IefmCOfl E MA 1aLma GITAs mmt wimp JMMT aaamam, t1A11em T R M.Tw 1Dl tA� m d m®Dom/m E OrA TMm1As w PMaIIi IE 19WMCM aaN aTt VZOW s A=VZM M Aw Macs a u DarAVQMI r MIip�E APLQYA alaY®t waA Inca s ssameA ---� �rM@t CAR= AMmaEi M AIItIM MI FE PM! EiO810 m rNratmt aaaaAama tr F" u m w emmaT arrpTM M lID TatRa ZIP T7 � wTM�mtv�� Mttes E aE Im TMrs� a LL REFER TO PAOC FOR CONNECCICN. 0 ti TYPICAL 7' SETBACK CORNERSET LABELING AND SPACING PLUM SHINGLE ROOF Reviewed for Code Compliance f r f Universal Engineering Sciences 0 Total Truss Quantity = 75 Labeled End Mark General Notes 1) gNFdaa AaNd 8ia ma M trt� ald AR m a ird '1rP dda Pater 9� 2) Al to a m a Slageat HI578 Nato vtlatslM 3) Idea DU Al Vmkq Is 24' O.C. asls 4) Pr Tm Pad , 'n , 8C51-81 tamnm�daUon pamlmMA 2-hmht2 =riladd M Waad at a IslmdrtMn apacFq Ts o.C. aaam 8r avm. to bs repwW d a K m . of 2W btI ea h tafa• m *w md�O 1for aW addVoW by ft debAL ROOF LOADING SCHEDULE TCLL CCLL O PSF B7PSF BCDL 10 PSF TOTAL = 37 PSF DURATION = 1.26 X HIND SPD/TYP[= 160 ENCLOSED BLDG EXPOSURE — C USAGE -RESIDENTIAL CAT H HIND IMPORTANCE FACTOR= 1 UPLIFTS BASED ON= 9.2 PSF DESIGN CRITERIA FBC 2020 TPI 2014 Trussmrnsber SCR &connectorplates m dosigned forACE 7-lOand maximum forces W m both compoaeats and claddmp end mein wiud fosse resisting systems. " These trusses have been reviewed to cany an, ndditioval lOY psfvon-co u"ent bottom chonllrve load. FLOOR LOADING SCHEDUL TCLL = PSF TCDL = PSF BCDL = PSF TOTAL = PSF ROOF DESIGNED FOR SHINGLE AM RUCnONS AND UPLTETS ARE SHOW ON ENGINEERING WALL KEY tea' -a" mm ® 0 DESCRIPTION INIT. DATE tau .= eat wn Rn TAE Lau INr TAM 's 1 1 l CARPENTER CONTRACTORS OF AMERICA 3900 AVEME Cn N. W. WINTER HAVEN FLORIDA 33880 PHONEr(800) 959-8806 FAXr (863) 294-2488 BUILDER D.R. HORTON SPATERIDE PROJECTCRE]WIDE MODEL 1828/CALT/4EBD / CCA PROJ/MODEL/ALT 7A6/ 320/182ED,F/ 02 ALT DESGM UMM 800K T/10 ID COT UN OTC 9516 POTOMAC DRM/ — LOT 119 d BLOCK DESIGNER RES 1 1 l CARPENTER CONTRACTORS OF AMERICA 3900 AVEME Cn N. W. WINTER HAVEN FLORIDA 33880 PHONEr(800) 959-8806 FAXr (863) 294-2488 BUILDER D.R. HORTON SPATERIDE PROJECTCRE]WIDE MODEL 1828/CALT/4EBD / CCA PROJ/MODEL/ALT 7A6/ 320/182ED,F/ 02 ALT DESGM UMM 800K T/10 ID COT UN OTC 9516 POTOMAC DRM/ — LOT 119 d BLOCK DESIGNER RES PAGE 1 3 17 1 pp31 NSCALE 334504L 1 4 "=1' Builder: Project: Model/Building: Lot Alt: ENGINEERING PACKAGE �DR HORTON /STATEWIDE _ 1 L7A5/329_ CREEKS IDE 182ED,F 0 2 G ...._. Lot: [119 � Block: Unit: L� Address: ;.. JobNumber: �1\1334504 Revision Date: New Load #: RI0°1 Reviewed for Code Compliance CARPENTER COBVTRACTORS OF AMERICA, INC Universal Engineering Sciences 3900 AVENUE G. N.W. WINTER HAVEN, FLORIDA 33880 PH (800) 959-8806 FAX (941) 294-7934 ALPINE Mardi 13,20.19 ANrrWc&iPt-Nv M. r. Bob Michaelis 6ht0r'Co.n'tr6ctO'it6f Amdricia., Inic- -390P Avenue 0.,. Northwest Water Haven,. FL 33880-6201 Re: Alt.Ornat.M ihstdllatjons-.for 6 single ply+ carried Miss with a width less than the, hanger width, .9n . .and wood.blocking lachieve full design load val)60 for face -mounted: hanger ment �6`n, a- one ply' .i;uoportin:'g"'g*irder.'(,R*Eife'r6*'n'd'd detail WMM2).. Dear Bob, :F&-a single Ply carried truss "with 'a width dth less than the harigee. width -yod'. prefabricated jack sob truss for wood filler blp'c;kihgi. The, chord: sites-:,ch cd.gratles, and Alpine:-;Obh '6 t pf (s) to n �b or. ate be - the. same :as the single: ply.carried truss. The prefabricated jack't6db'truss have a. minim M Jengit of 4W and will.have a. minimum plt6h-:of.V12... The single ply carr I ied,, truss shall have.a rea aon of 3,.500#orless. Attach oref9bdcate Jack:scab,truss. witlI two. (2-) rows of 0.1 28"x3,07' GUn Nails atT Q..:q.-.pqe_rpW,.stagger6d 1*"._(q Figure' I b616W). P16�se'-.refbr to the' Simpson Strong -Tie Catafog C.-C ..2­4i­ . �,.. . .- _­___ _1 � - _­ - . ­_ ­ Q ppg.p P.Pigpre.'.8 .-for more information:. J Figmre I Fora single, ply'', gied e-r'that requires wood blocking to.6chieveftill design load Value for face -mounted hangers one wood; block to the back face of thesingle ply girder with the same size: and grade as the bottom. bh&d.. Ofthe. single. -ply girder. The. -Wood: block length to be sUbh that 'the wood blodkifig-extends to each adjacent panel points ;(Wbbs`.Afid bo%om.ch6rd intersections). Attach wood 1 28° x3. 0" Gun Nails dt. 0'. O.C.per; TOA. staggered 3.0p* applied W the 'f6766Forum 'Drive Suite 305, Q.Orlando;. nd. o; FL. .. 372821-(800)-621-9790-_. ' " 4227885 -www.al*PIneitw_,com r / , ALPINE .AN fM COIWM. single ply -girder face, with.man additional (20) 0,128x&W C3un.NW!s j4t.each pgin. I r-g--'-^'`�.'—V—'---'--'--- _ _.... ............ ......... ________________________________ __________________________________________ _ The of-pt&bbricaited hack 'scab ttd�mfor Wood fi0e'rL8ocki' 'orvmood t0fitd| design koad'vakuefor ' Must the. hardware m4nufac I ^ ' d ��d��hd �Md '_ |��U �bnU���� t� - of -- _"- - . . ~` .� -','--`° If|can.bxeofany further assistance, or if. you �have anyq ' me a cal ' Ghief Engineer, mpony O�Iandoj FL � 6750 FdrbnhDhvLaGuit6'385'Ddobd�.FL32821-[OOO).6a1-.979O-(863)422'8686 WWW I om ALPINE %iwcOM_1MY April 26,2019- Mr. Bob Michaelis Carpehter Cobtraidtors -of Arne rib,4, Ind. Avenue 0, Npr.thWipst Winter Hav6n, FL 33880,6201� Dear. Bob, Rd' Str6noback bridgih4.6h tbbftrusset. I understand -there. is'some. concern over our feddibinendab6m f6rstrdhg.back- bridging on. rooftrusses;. 8fra*Ack- bridging roof trusses is not.a ..requirement of:ANSVTPI 2014 npris it a requirementofthe Building Component -S Safety information i on .t st ron gback. bridging Li orY roof- :trusses is recompie .'ar hter Contract rs,.Of. rnerica'§tfqn'gb6dk. bOdOMg .serVeA wipg..two._.- functions: One, bridging aligns the bottom chords lafter they: are- set so.. the are uniform, along the ceiling lin6 and heio*kwth"c, ei Ii n-g 'sorvi o-eabi lity. Twoj brid ing reduces f6lativ6 deflection .of. adjabdntlhuss6s:, Strongback Mdging'.do6s: not: --prevent or reduceoverallindividual deflection, etpecially any rooiftrusise's, " than 1/4" inch. ..........._......_.deflect _ng . .. ..... ---- — ------ Si bridging in roof.. trusses doves 'not serve as �eirmaifiehtw bracing �and is not. rongoaqk- bri( g .intended to .distribute. or share, design loads, beNveah trusses. Consequently, no design load'* have .1peen accounted for With thig.bletail an . d dohtihLibLis-str6hgback*bddgirid -s�hduId;hotb6:Attaic'hed between m . p. common . and :girder fnisses-.- The use :of strongback. i9 . bridging shall not.'interfere with other- design considerations as specified .by the EMgihabr*.*O.f R6c&d or the Building: Desi Ign6r. The outer ends of 'giroq&ack-bridging shall be.-afto.chedjo a. wall or anpther:secure end. restraint.; or ap..specifled:.py the Engineer of Rebord&Ahd Building..136sigh6r. Stron'g*b4ck- bridging'shall. be �a. minimum of 2X6 nominal tumib0r. oriented with th the depth Verticaf .. . Attach with - . - _. co n 1 (3) 1:8d :common nails (0j6Tx&*5.-) nails 'at: each intersecting 'rhembet. Whe -extending the .Strongbadk bridging overlap by -at. a.minimpm of. two trusses. The.jocatioq offha.strongioacik": 6ddging. maybe: specified . b he. Truss . MahUfadVr'.'er-,. Ehbihe&r of Record, or Building Designer: Please ref& --to e Alpin.iinformation. The'. graphid CS Strongbacking Provisions" or:to :$TROR-18.Ripf detail for more. information. ,§hoWh (FidUr'ie-1) is for Alu&dti e only. illustrative purpos n F.6rum DriveSuite 305, O.Mndo, FL 32821*- (800) 521-5790i.- (8631,422­8685 ALPINEA"alven-AkIv Figured. If I: can b6 of any further assistance' or -if you ,have :-.any questions; please; give. me a call. Williath. H,,Knck- P.E. phief-.Eng-peer Alphe an !TW.:.Co.mp8ny Engineering 'Department -Odtfri.do- . FL V821. 15760 - Forum Drive Suite.365k, Cr(6n'db,- FL 32821 - (800) 521-9,790'- (8153)-.422-18685' wwwA piri.e.1 .com S . TRON .. (33ACK: 'BRIDGING BUT.T.STRONGBACK :BRIDGING TOGETHER 'ATTACH SCAR WITH'10d:BOX/GUN. 4t * 'x3.0'!i NAILS 'X�2 ROWS`AT ;SCAB' .6o D.C. NOTE, -.*IN LIEU.*UF SPLICING AS, SHOWN, LAP'STRONGBACK 'BRIDGING MEMBERS Fllk:AT'LEAST ONE -TR=,,SPACING ST.RIINGBACK BRIDGIN15 'SPLICE DETAIL RECOMMENDATIONS I Oil- All scab -.on blocks s:hail, ble:,a minimum. 2x4. 'stress orqcIed lumb.e.t,-,:' P---All str-ongback bridging .and bracing -shall .be :a. h MInWM 2X6 'stress' graded' . I. u ri b eq; 0ii-.Tie purpose of sirondb.ack :brld6lhg-is. to develop load sharing bietwe?n` IndlVidu61' trusses,: resUtIng In, dn :b-�,6rqLL']h&6a;qe- In',Ahip- stiOnessr of,'�-.the.'ftoor systeft st"ngback brldglng, pbsitldhod 6sj'.sKaw' In cletalls, Is recommended at 101 =Oi'.&C. Kmax;) 0—Th0- terms 'Vribit9Ind' and :'b*t;-*cidnq-1' :are- some -times .- mistakenly: �u ' seci:*:In.tL-t-changie;obty.** Is an fmp0*rt6n*t structural teguIrehent of:any" f oar or roof sys.tem, Refe-theTruss. Resloh (TDD) -fdr, "the: brgdng r4quW,.-'6P.1ent - s f6r , a h In*d1VIcIC4 I. .tr uss russ component, 'Brldgl* g* particularly recommendation'for "a' truss'system to, help contr*oL v 16raAlor.). Irs: addition; -to- aiding.. In the distr1b.UtIon of point Abads loetw.eieh adjacent -, trusssk bridging, servest �o reduce -strongbac :N(;. , qTS ; td i EiiC /3 vc�is) a *As) Pounce. or res-IqUat vlbraiitlph. resulting, frog, moving pQ.tn..t Ibqclsj:such pt-s footsteps. The performance of all . floor ems - are �syst enhanced by. the. Inst-allatId.h bf, -s+r61ng6aitk brIcIgInb and -t-hereforeJi strongly recommended by Alpine. 1 For additional Infdi-matloh rebqrdlhg strongback b4-Ic1b1ng,. refer to%SI'-(Budding '. Component Safety Information). follow V* lolks:11 edtlon 30CUSE (Mlift CoQl�t Saftij lrlfo,,Atior,.T;y Tpt Qw:fvc Fet 47. Ahl'sw A . kktkn' Imtoklars shoji oroyAw A$ For I Fe NO. 70861. sholt hovi. a, proWly ottacht d 0opqr4y-cit-kadwal x=— po Will. vach:' 9 Al 51o. JAtr Dttals, =$go no .0 S of tr=rll� Post LF vktln* 1`4 E F AN MWMfANY w"Tivio; baldVw Amax-ki conf J'Ith A41/71`11: 1. f�mw V.; . kwiafttlon L. braeke of. irvasom WIWI". whook .A se04on.ihlt:ekfNip or•Kovrr peps wkh oft Simko hdcatez-accip profetzsciAl 10 W &�.*v - Y -Thv.PA%lAKy-*rd —Ofl.-t it - A&M, :M*U'D!sVr pw V stcz I —� X11 8010 WO moiftm FAIgIltsi. M9 ihose v6 -stligza tf.74rl" NO "Viclisar"ra .L L: PSF I iDL. :PSF I WL PSF- 1. E 'LL.. .. - PSF' - /ILD, PSF FAC.. V :-FJ� �0,0# ,A� . x� BE R AIOO - . d ...0 9C NMIATE kr i QtJ :`Td:'�1F�E? ' - PLO oag..S��0a "It�N, �•Sr�:TERIAL.- AT .iLeAST 2- TRUSS ROM,' s'E �i �11�i���lk��,'Yi.�+,����-,tn1��r%IS. F0ri:.L.UMVRI1 Pi Sxl�'.ru ARtiS7-OTHER 0 TA a, aTO. BE SURPLIC ar rt �i,. , 11 �i'si 1 ��"&!►_ Z �x'f 1'oA.. k� t uy o; .r bi:fek 38-jp fi( , ;._:... ' .'e•."^'�'v � c i.• .r{ps ^I!IIRI,s'+ v'ii ' �,,.,�.nriu'sn4,.-,..�:J. 12 AXA+j�j,�+r�• POI STS- I 77 ... ' J-PL fi p.VAL ... rll CE7 •4 C " 7 f! t3 . : .ram. ate, _ . � 'ems. I ;. .:L. . ' ..' - .. • red �-,,;. f,AP LP UP xvw a O'trZ JNIOddS are'y9saa5AAA uv/Sgmpuags'kaM y]¢S faro';1ud;aA fuoi'a;lau rANld,r lsa;Is qaoalM as.tt}(Opt19 1 a se;ou lvrauaE s,qo(' a14Lvaax uq;oltuvJ4 Rj*weM roJ Stagg ow'40 3 ':vat I IJUjtky .aad rsV"sa $Vpm ay} /e A;{ygauodwa sf a.ryan.gs Atry ro/ Oyraep rN} /o asn o Ri"R*%pe s41 VAQW WOOF :f %- avI AIMS UIITWA f• aY+�+e anp0 Wvye>le, E9ECl • lvuofsr+lo'ra ,fa awKdr av xnvN �t 'aiawF s144 &AW Mvd u1Aoa x 6*94P T4. W rox y inyej Aue 'Ottddi a AAN .+e/ •+o 't Edl/]Sky t�4a aauvuro�uvv W ssn+} +4}�IV+4 v4 TuupgevipvsM: uaJ/ uq}a�nap Aug Ja/ alglsuodear aq }v nv4S 'nut ore s4mauodue2 ulpyn[ ALI yv uolhWa v 4l{dIY MYJ'YO] A&U NY ' 5 'rug141rgd /ygld prapu9;s rot i.ya9t �u1A9Jp a} ryt.11 + Vspuiy}o p+3?U .sal1vo Issusir }uler a4i. ue pue sAoo4 go uAs sg uo�;lsod Pug ssnr}o �I f11 I I anvd tinge a4 ";.vid A y algviaadv a •al[ ro L, 'Ct swtt u 1S�H rrd p+ll-ut 04a9rq SA94 IMP 4ujYaa Alradord .._. U KOTQ?JH3d32J JM21Q sgaA 40 }4w}1er Iveyol }uauvwad .lod uav4s suepwv� pg' paypn%.v v 8n9t1 11+4s p4a4a ua}}vq pug "va4s 19.At M4x pagiv;;v Alrsdadd BA94 II94s prelim do; IsgAratgv pe}vu salon 01, 'suvµnunl eu�ura,dad oL +qrd saat}i i Inc red 44 rgrgdua}f .RAvrd k941 sd.119;sui aa4} Aiales 40/ (Wet Pug M A %040-ry utt A}a mS puaueduoa &APITD Inn Jo uol;pA }sa}9 ay} Aelly/ pug *4 radaa oulavaq pug �Ilv"ul '�ddW '04"4 '04921r494 4 arvi soar}Na a.gnba,i sassruL ti T/TO/OT 31bQ sa3„vtstrt IDKIA�MtIIHH11 w sa m+1N°,rf AQIn W aaVU BFRL DH1IMNON 1>l1dlWao NIdd3N N3EW3W d3N e aiw NM' i� .. 1!,0�-a(1 6ul:radS 1!'ON #0999 #S609 #0829 #S919 • gxz p,4090 .ao qaM #9"V #OL•OV ##096 6xz p.4093 JO qaM. #SZLS #SzzS #OOSt? #S6E# .ztr gxZ paot,18 .4o qaM #SE8E #SOSE #SbOE #SL6Z Vxz p,40NO .40 qaM #St�Lt� #S6�tr #SE9£ #SES£ a9E 9x2 pjo�j '40 qam #OTZ£ #0662 #OESZ #OL- 2 bx8 p•40t;1e AO qaM #SLS£ #SITE #99£2 #OE28 .OE 9x8 P,40gO uo qaM #SS28 #STEZ 0096T #0W trxz p'+o�3 jo qaM #0298 #SbzZ #9891 #S9IFI .bz 9xz pjo�. ao qaM #SfrLT #96K #SSOT #SL6 jxz p,40140 'to qaM #STbl #S621 #SSOT #9L6 .8T bxa �1u0 o1aM 4008 #0£L #S£9 #029 121 Vxz Alu8 qaM dAS -1-AI dH 3--id S -1 azlS ;.aagwaW an,40-1 l-01xy .Aagwaw wnwlxvW p•oo-1 jo uola.lo.An(r �o,4 pas„aaoul aq A'ow sao�lo j .4agwaW %0 = ual4,v.,mCj pno-1 1�-o�-aC[ .�inda� .�ac�waw aaa tiffs mod a lul' - .4agwaW 9xZ ;.Aa06nq.s MON algod - ,AaclwaW trxa aaod }uo,Ad = O 15TON (ulw "E x .82T'O) xog poi ao+od >{avg = ,4a66n� S + O + O + O + O 0 +" O + O + O + looldAj • � i - 1 •r spool u -a17' Awo �.aoddns q-ou Avw pjoLp ua>jojjj oa ao al.v)d .aoa.:Iauuo:) aNq. uIN}�m eul a,an��o suol� roes qam Jo p.1oq= pa8owop x f pasn aq }ou ow llv}ap Ilroda.a s141 'saDllds lauvd—plw ;.v al. -old ,ao) nauuoo uano.aq ,ao,+ pasty aq stow 11m:pp Alloda,A slNl f0S91 aproa0 NSW puv. ilk apv A8 1onsIA ol• paq Iwll sl 11nT•ap sINl• y;.lm asn•.4o.4 ap-ojo iagwnl pag4lw.lad wnwixow aqj �,aagwaw apls: t{:5va o}ul (ulw ',gx,BEI'0) sllvu un8 .ao xoq p0[ 6ulsn 1loN 'palaa88ro}s smog "VO av a.v smo,a (g) aa,aq:l 8u1sn s Iagwaw 9xZ o#.ul WON �a.la88o}s smoi "Vo h Vo smo a (B) oml� Bulsn sJagwaw M2 o4.ul 11-ON 'laved ua).{o,aq aLJ4. ul4glm aq }snw (S) yq_8ual Aagwaw q•oaS (E) + (Mp,) = (s)q;.Bual iagwaw apls wnwlu�W azlo3 Aad gv5s auo iddy '.aagwaw pa8owop so salsa s puv rapv.48 razls awns 's.aagwaw apls gxa CM;. 40 yxZ oml = (S) (g) oa.ao pa8owop 4o apls tpoa uo anuo}sip Bulllou wnwiulw = (-I) uola.-zas pa8owop 3o ya.8ual xow ,-al; roa.ro paBvwo(I= (g) llvl-ap sIWq' Nl•Im Aldwoo lou op ;.m4l. s aloda,a .Awv ,Io j J"n}oroJnurow ssn.aa. ay} a.00q.uoa pamo lv a.ao ssn,aa. isd sMva4q om} uvgq. a.aow ou pun lauvd p.aog:) 4ad >Iua.aq auo uv4 a.aow oil s-4agwaw ua>lo,aq gxZ jo yx0 Lla.1m sassn.a} Ald alBuls JO f Aluo pllvA sl u(3lsap slNl '.aagwaw qaM .ao p.aogn uas{o aq 4g1m ssnj5, o .toj s.aloda.a sa13loads Ggwo,ap s141 ua>10ja j0 10a>j:)n.A3 gpdg BOARD (2xi) RA VALLEYF: -umber Size and drade: Minum,um Requirements. -R V -F TRUSS UNDE ALLEY !~BANE VbNLLE[� RA MiP..OR RII)CiE Purwn.sjl�rml "dot +1;rJppIeb,41-V`1dr-36 psf -26 P9f (.TDJ Max. Spa f".th4,vwlvys brGlooParr. pte (ocatic ns are ....... .. .. . -(Ty�) b" O.C. BEAM,AVERV InORCL RAFTERS -(Ylfwrq VLt 'AL 'JkoA v cr-thr.bu§N'.`; d by-vihem) mails, 46 rafter, .njalls are lo.P'LA Kogulvenent N qlLeR A 1Q,tdi-siglu. W 'fiii. fiAide -diredtly 7- drY&i!ffl'djd:. 4 x6dlo"ills '416dtoemaIN Airig 3. t�V XV-notch In ShQ2thlng . . i 4. Raftiefd _41dipaf4'Vbckift. 5 g5ft&;t6-.two 7x6 sleepers.' 4 1 6d toe -nabs S. -sldepdi tki-btfi' 4'1:6d W&WIs .f slaepe s. .:Eudge:bohr4ia-T.onfbIdck 416d toe-nkills 4 3,%-Wipy4Jts - 3 .-Frumni to. (Tvpj, 7" 4*16d,toc-OWI$ 10. 1 Truss-tdiOlpptv: 4-164.-toenajli 4-16.d.toertidlb USED) .13. Veana tb� xaftdt . 4 lodu!!-nalls. NAILS .Plei 5,4!" fd 0,4":lob( ffiimebVV1vtflddJ1d.fl1i(. k-p . fiss raftur i(steopem.are.not y;q4,. -Sans tnw6eewhear�y.opi # iop GhdYds•and. ii�"-V.allay halg[ft; 14'-0' 0NDS AimmRnis; -Max[muM rfi0A 'tqbf helght. 30-toet 4plaabo. niae�XsArtby oyy Woph vid mphi.Enclosed, Cat It, AHk .M 'A. . vaw­ -WA o: lw=:q- w*Nt 'VittP! A . md, SVW, for_-!Wr TC DL- I ti 2,10 7 DATE 10/91/1'4 V. kiHkOna. pev, -0 om Lr 4, 0 0 0 DRW..G V. QW1801015 pW P..j 411.4pir -,qTAT. - I. hwC 4k- Be L tiVTrii• •.0 0 0 MON r ii f<r fW­ .-Mai 100wik: W�i­bi,-,dc�' WX -d PAtt P.- ttv &Adw 6.vQh�•-Y' e1i 'TbT. LD 7 61 ttc'tm&s'h cWorhKmir AN G­;o P-w� shag no?. be rutpar"dW9. e—.. c' VTF1 -L or for' pW WAV *q4& *K6)*1- 71 1 L 5� P, Azm. - . . 1.•b i43ABOVE L im.:..azrafraro Face -Mount Hangers - I -Joists, Glulam and SCL ' � 6 ................... .... _...._.._...................................... __............... __._................. _..................... ................ _.......... _._._._............ ' ED These products are available with additional corrosion protection. For more information, see p.15. Codes: See p.12 for Code Reference Key Chart. ism am Carded Dimensions q Fasteners Member (m:} {m) AlldwaUle Loads ` size 'NO w weo Max Species Header ( Species Header Ref:- (m.) SUff W H ,. B ; - Face Joist - Uplift floor Snow [ Roof i Floor Snow Roof , r (160) (100) (115}, {125) ;(i00) `(115} (125) Min. (14) 0.148 x 3 - 70 11,660 1,805 11,805 1,425 1,555 1.5J5 IUS2.56/16 • - 25/6 16 2 Max. (16) 0.148 x 3 - 70 1,805 1,805 1 1,805 ' 555 1,555 1,555 2Yz x 16 MIU2.56/16 • - 29/16 157/16 21h - (24) 0.162 x 31h (2) 0.148 x 1'/z 230 3,455 3,920 4,045 2,970 3,370 3,480 U314 ✓ 29l76 101h 2 - (16) 0.162 x 31/z" (6) 0.148 x 11h" 970 1,945 2,205 2,375 1,675 1,895 2,045 HU316 / HUG316 • ✓ 29/,6 14% 21/z - (20) 0.162 x 31/z (8) 0148 x 11/z 1,515 2,975 3,360 3,610 2,565 2,895 3,110 IBC, "x MIU2 56/ 8 2"Xx, '- ;(26) 0162 x 31/2, (2) 0:148 x 1?h.` 23Q 3 745 4';045 4 045,:3 220 j 3,480 3,480, LA 21/z 18 ' �HU316 % HUG316 ' •' '✓. 29ir. 14Ya _21/z" `- `{20).:0162 x 3Y' , , (8) 0.7`AS x 1'1h"�' 1515 :2 975 3,360 i 3,610:� 2565,! 2;895 3110�: 21/z x 20 MIU2.56/20 - 29/16 19�'16 21/z - (28) 0.162 x 31/z (2) 0.148 x 11/z 230 4,030 4,060 4,060 3,465 3,495 13,495 2Yz x 22MIU2 t2 z6 56120 ✓ 2%6 1915 21/z -- (28) 0162 x 31/z �(2) 0.1`48 x 1'/z ". 230. 4,030 4 O60 4 060 3;465 3;495 3 495; 29A6 x 91/4 to 26 29h6" wide joists use the same hangers as 21/z" wide joists and have the same bads. "MIU3121in - . 3". ,l o .�y/,. , 1 � 1 1/4 1� �1 4 h, 9 ,(6)0.,62x3,r (2).0. 8x /z 230: ,305 2,6 5(2820 ;980 2,2 5 2425 3x91h HU210 2 MUC210 2 ✓ 13Ya-, " 81fc 2.1h tax. -: {18)0162 x 31Iz ., (10) Q148 x 3 5 2,680, 3,020, 3 250 2,305: 2,605 2,800; IBC, MIU3.12/11 1-1 131A 111% 21/z - (20) 0.162 x 31/z (2) 0.148 x 11/z 230 2,880 3,135 3,135 2,475 2,695 2,695 FL, 3 x 11'/6 HU212,27HUG212=2� " 41 '-31/6 '" 1N9 ' -21/z Max: - (22) 0.162x3'/z' - `(1%-9.i48x`3",' 1 79E 3,275 3,695- 3,970 2;820�3;t80 3,425 i'A= HU3.25/12/HUC3.25i12 3'!ai 1131a 21Jz .- '(24)`0:162x3'Iz (2}4748x3, 1 r :3570; 4;03044,335 3075 3,470 3,735; HU3.25/16 / HUC3.25/16 ! 3'la f 131ia 2Yz Min Max (20) 0,162.x 31/a (26pQ 162X 31/z (8) 0148 x 3 .. ':(12) 0.148 x3 1,516 '2,975 3;870 3;360 € 3 610 14,865. 4;695 2;560 j•3;330l 2' 8,755 3,105, 4,040= - 31/a fllulam HUCO210=2 SDS °F- 3'1a. 9 °: 3 - (12),1I4' x 211z' SDS (6)1/4' X 2Yz' SDS 25 4„S1ar 15 315 3tfCiOl 8,71t3 3;71 n FL HGUS3:25/10 85/s'. A _ ' (46)01620"%a (16) 0,162 x 31h 4 095 9;100' 9,100';:9:100 7825, 7,825 7,825'I IBC, HGUS3.25/12 • � 3?/4 I ,105/a. 4 -. .{56)11,162 x 3'/z ; . (20) 0,162 x^311z 5,040 9;400 9'400 (9,400 �8 685 i�8;085 8485` FL LGU3.25;SDS - "' - ,3?Ia 8 to-30 ° 41/z-' {j6)1/4' x2?%z'"SDS. (12)`la' S( 21h" SDS 5;555 6;720 7 ;1;) stn, , 4840 HHUS46 - 3% 51/8 3 - (14) 0.162 x 31/z (6) 0.162 x 31/z 1,320 2,785 3,155:3,405 2,395 12,715 2,930 31h x 51/a HGUS46 - 3% Or, 4 - (20) 0.162 x 31/z (8) 0.162 x 31/z 2,155 4,360 4,885 j 5,230 3,750 4,200 4,500 "'<HUS48 j • • . �= � 3?I6 6lY+e 2 = - °j6} 0.162 z 31h (6) 0:1'62 x 311z' .1, 3'20 J 595 1,8-1 1 960 _1"(365 1;555 1 31/ x 71/4;;' HHUS48 ; `" - . - 3$/6 7�Is',; 3:.. ,= ',(22)'0162`x31h : °(8) 0.162 x 31/z a 4;210 4 770' 5140. 3 615 9,095 4,415 HGUS48 ` - t3 .. 734s 4: - (36) 0162 x 31h', {12);0.162 x 3'h ' 3,235 7,460 7,460;u7 460 j 6 41516.415 6 415 IUS3.56/9.5 - 3-1/1 91/z 2 - (10) 0.148 x 3 - 70 1,185 11,345 11,455 1,020 1,160 11,250 MIU3.56/9 - 39h6 813/"6 21h - (16) 0.162 x 31/z (2) 0.148 x 11/z 210 2,305 2,615 2,820 1,980 2,245 2,425 U410 • • • ✓ 39/6 83/6 2 - (14) 0.162 x 31/z (6) 0.148 x 3 9,10 2,015 2,285 2,465 1,735 1,965 2,120 HUS410 - 39f 6 815A6 2 - (8) 0.162 x 31h (8) 0.162 x 31/z 2,990 2,125 2,420 2,615 1,820 2,070 2,240 HHUS410 • • - 3% 9 3 - (30) 0.162 x 31/z (10) 0.162 x 31/z 3,5C5 5,635 6,380 6,445 4,845 5,486 5,545 31/z x 91/z HU410/HUC410 • • ✓ 39/i6 8% 21h - (36) 0.162 x 31/z (12) 0.162 x 31h 3,235 7,460 7,460 7,460 6,4151 6,415 6,415 HUC0410 SDS • • - 39/16 9 3 - (12)1/4" x 21/2" SDS (6)1/4" x 21/z" SDS 2,265 4,500 4,500 4,500 3,240 3,240 13,240 HGUS410 • • - 35/6 91/i6 4 - (46) 0.162 x 31/z (16) 0.162 x 31/z 4,095 9,100 9,100 9,100 17,825 17,825 7,825 IBC, LGU3.63-SDS • • - 3% 8 to 30 41/z - (16)114" x 21/2" SDS (12)1/4" x 21/2" SDS 5,555 6,720 6,720 6,720 4,840 4,840 4,840 Lp MGU3.63-SDS • • - 35/a 91/4 to 30 41/z - (24)1/4" x 21/z" SDS (16)1/4" x 21/z" SDS 7,260 9,450 9,450 9,450 6,805 6,805 6,805 JUS3.56/11.88 '� 35/6 i 11'/8; 2 ; _ , (12),0.148 x 3 _: - it 1,A20 1,615 1745;`�1220 1 390 1;485i MIU3.56111 - j 39fi6 :11?!s 21h ''- ::(20) 0,162 x 31lz', , (2) 0.148 x 111zf `. 21fl" 2,880 .3,135';j 3,135' 2475 } 2,fi95 2,695 U414 •. • • ` ✓ 3sti6 16"- 2 ; .- . -(16}; 0.1.62 x 31h (6) 0148 X 3 `;' °7?3 , 2 305i .2,615';1.2,820"f,1980 2;245, 2.425; HHUS410 �' • 3$/s 9:.a . 0.162x3i/z A62 x3Iz h55, 5;356, a 4A 'W',3 , 5 HUS412 ! 13,461 10?/z; , 2 -(10) 0'.162 x 31h'-_ (10) 0.162 z 3Y 3,4365, 2 660` 3,025 3;265 )2' 275 12,590 2;795` .31hx11W " j HU412/HUC412 "� -Ns I ), 10 16 21/z Mm (16) 0162 x 31h (6) 0.148 x 3 : 1,135' 2,38uZ685 2 890' 2�50° 2,315 2`490 Max. , -(22) 0.162 x 311s (19), 4$ x 3 , , r 5 3,275' 3,695 3j97012,820, 3,180 3,425- ',HUCQ412 SD5�` 39j+6 11�,`. w .,(1.4)1/4' x 2'/i' SDS (6) �4':x2'/z'.' SDS ��26 5,04 1o1 u,045, °,G�E30 i � HGUS4f 2 , ." - 35A " 107,6 4 -' .,(56)A 162 x 31F�',, _ (20) 0 762 x 31/z„ .6 9,900 9,404 9,400 8 085 �'8,085 i 8,085. LGU3.63` SDS • 316, a,8 to 30 ', �41. ` = (16) Ya" x 2Yz; SD'S (12) �/i'; 21/z, SDS 5,555 6,720 6,720 ,6,720, 4j84014,8 40� 4,840 �'.MGU3.63 SDS , ! _' - } 31a. 9'/ato.30 41h - (24)1%a'. x'21/z" SDS (16)14, -;> 21N' SDS 7,260 9,450 9,450` 9,Q50 6',805 6;80516,$05: HC?U3.63aSDS , ; „ !e ! - _.t,3ls '11'to 30 , ,41Iz =, (36)'%q X 2'h�SDS (24)1/d' x 21h" SDS 4 40G1 46 See footnotes on p.150. SIMPSON THA/THAC - Adjustable Truss Hangers This product is preferable to similar connectors because of (a) easier installation, (b) higher loads, (c) lower installed cost, or a combination of these features. The THA series have extra long straps that can be field -formed to give height adjustability and top -flange hanger convenience. THA hangers can be installed as top -flange or face -mount hangers. THA4x and THA2x-2 models feature a dense nail pattern in the straps, which provides more installation options and allows for easy top -flange installation. Material: See table N Finish: Galvanized. Some products available in ZMAX® coating. �- See Corrosion Information, pp.13-15. 0 U Installation: m Use all specified fasteners; see General Notes. ci C The following installation methods may be used: N • Top -Flange Installation — The straps must be field formed. 3 over the header — see table for minimum top -flange requirements. H Install top and face nails according to the table. Top nails shall dnot be within 1/4" from the edge of the top -flange members. For ^thaTHA29; nails used for joist attachmert•nwst•b&-driven-titan d angle so that they penetrate through the corner of the joist and into the header. For all other top -flange installations, straighten the double -shear nailing tabs and install the nails straight into Fz. the joist. • Face -Mount (Min.) Installation — Install face nails according to the table, with at least half of the required fasteners in the top half of the header.'Not all nail holes in the straps will be filled. Nails must have a minimum 1/2" edge distance. Stralghten the double -shear nailing tabs and install the joist nails straight into 'the joist. The face -mount (min.) installation option accommodates conditions where the supported member hangs either partially or entirely below the header. • Face -Mount (Max.) Installation — Install face nails according to the table. Not all nail holes in the straps will be filled except for the following models: THA29, THA213, THA218 and THA413. For all other models with more nail holes than required, the straps may be installed straight or wrapped over the header, with the tabulated . quantity of face nails installed into the face and top of the header. The lowest four face holes must be filled. Nails used for the joist attachment must be driven at an angle so that they penetrate through the corner of the joist into the header. • Uplift — Lowest face nails must be filled to achieve uplift loads. Options: • THA hangers available with the header flanges turned in for 35/a" (except THA413) and larger, with no load reduction — order THAC hanger. Codes: See p.12 for Code Reference Key Chart for A22 for 122.2 126-2 THAC422 13/i typical 2Vz' for THA422-2 and THA426-2 THA418 2h«='I a- r� . c THA29 Double 42 - 2 face nails Use full table value (total) Single 4x2 �a 4 top nails IsS table (totaQ nailertable . %' Straighten the double shear nailing tabs and install nails straight into the joist Typical THA Top Flange Installation on a Nailer (except THA29) THA422 Face -Mount (Max.) Installation Straps maybe installed straight or wrapped over with tabulated face nails installed into top and face of headE ® Double -Shear Double i Nailing Dome Double -Shear Shear Side View; Nailing Side View I; Nailing Do not (Available on Top View bend tabs, ' some models) Top Flange Installation on a 4x2 Floor Truss THA44 Face -Mount (Min.) Installation rypluai 111�v Top Flange Installation 'er to tnote 5 p.187 86 THA/THAC Adjustable Truss Hangers (cont.) ® These products are available with additional corrosion protection. For more information, see p.15. a P 1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 2. Wind (160) is a download rating. 3. Min. top flange refers to the minimum length of strap that must be field -formed over the header. The tabulated bads for the THA29 with 1112" min. top flange are based on a single 2x carrying member; all other top -flange installation loads are based on a minimum 2-ply 2x carrying member. For 4x2 truss carrying members with double top chords, use the specified fasteners for full tabulated values. For single 4x2 top chord or nailer applications, refer to the Nailer Table. 4. Face -mount installation bads are based on a two -pry 2x carrying member minimum. For single 2x carrying members, use 0.148" x 11h" nails in the carrying member and tabulated fasteners in the carried member, and use 0.80 of the table value for 18 gauge, and 0.68 of the table value for 16 gauge and 14 gauge. 5. For the THA 2x models, one strap may be installed vertically according to the face -mount nailing requirements and the other strap wrapped over the truss chord according to the top -flange nailing requirements (see drawing on p. 186) and achieve full tabulated top -flange installation loads. 6. Refer to installation instructions regarding fastener installation into carried hoist) member. Based on the installation condition, nails will be installed either straight with straighted double -shear nailing tabs or slanted. 7. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. 18 LUS/MUS/HUS/HHUS/HGUS Face -Mount Joist Hangers �G This product is preferable to similar connectors because of a) easier installation, b) higher loads, c) lower installed cost, or a combination of these features. T he double -shear hanger series, ranging from the light -capacity LUS hangers to the highest -capacity HGUS ^angers, feature innovative double -shear nailing that distributes the load through two points on each ;gist nail for greeter strength. This allows for fewer nails, faster installation and the use of all common nails for the same connection. For medium -load truss applications, the MUS offers a lower -cost alternative and easier installation than the HUS or THA hangers, while providing greater load capacity and bearing than the LUS. Material: See tables on pp. 194-195 Finish: Galvanized. Some products available in stainless steel or ZKWO coating. See Corrosion Information, pp.13-15. Installation: • Use all specified fasteners; see General Notes. • Nails must be driven at an angle through the joist or truss into the header to achieve the table loads. `- "-`--'� `f�7oT'�sigriecTfor werdetl'or naife'r'applications. - "-" '" Options: • LUS and MUS hangers cannot be modified • Concealed flanges are not available for HGUS and HHUS • Other sizes available; consult your Simpson Strong -Tie representative Codes: See p.12 for Code Reference Key Chart Double -Shear Nailing Top Mew -Shear Nailing CDouble Side Mew Do not bend tab Dome Double -Shear Nailing Side View (Available on some models) 1' for 2Xs t'tis' for 4x's� H i< • G� W B LUS28 HHUS210-2 HGUS28-2 MUS28 Typical HUS26 Installation with Reduced Heel Height (multiple member fastening by Designer) 19 Simpson Strong-TieO Wood Construction Connectors ............. . . . . . .. . .... . ................... . .. . . .......... ­­­­ ................................................ . . ................ . ... . . ...... . ................................ I ...... . .............. . . .... . .. .. . .. ................................ ......................................... I .......... Face --Mount Joist Hangers (cont.) Mm.', Model He No Height,,.el -Member Ga Dimensions (in:) ~Fasteners W --- H B Carrying:-": Carried', Member Single 2x Sizes iWS24` " 25/s` f8 " i•�/ ` ' 3'11s ='.y /a 4J 0148 x 3 {2) 0.148,x I.- LUS26"" 4Vaa 195a ''04..� 1Ya 'e(4);0.148x3 : «(4)014$x3 '- MUS26 41t/ia 18 11/a 53Ar, 2 (6). 0.148 x 3 (6) 0.148 x 3 HUS26 45A6 16 15/a 53A 3 (14) 0.162 x 31h (6) 0.162 x 31/2 HGUS26'', ,r: 4lis- 15/8 • ;!5'/a (20j�;0762.x3?lz �{8)0.1$Sx3112.� LUS28; '',: 43A6 18 19tia 651a 1 !a MUS28 I 65AG 18 19A6 6131a 2 (8) 0.148 x 3 (8) 0.148 x 3 HUS28 i 61/2 16 15/e 7 3 (22) 0.162 x 31/2 (8) 0.162 x 31/2 HGUS28 6-A6 12 15/a 71/a 5 (36) 0.162 x 31/2 (12) 0.162 x 31/2 OK10 '- ;. 4Ile,, " , . 18 :'. " bslia -71�e -� =;1-N ;(8 0:148 ?C3 'HUS210 11; '83w, 16 ' .15/a° 9 3- "(30):0.162x,31/2 1 (10)0.162x'3,1/z' H6US210 891a . 12, 1 sy _` " 911a `5 (46j'0,1, 62x 31/z , ..(16) 0,162 x 3'/z V1. See table below for allowable bads. W fA 3 i� a m c>s a � m These products are available with additional corrosion protection. For more information, see p.15. For stainless -steel fasteners, see p. 21. Many of these products are approved for installation (I with Strong -Drive® SD Connector screws. See pp. 335-337 for more information. -- LUS26 1,165 1 865 990 1 1,070 1,355 1 1,165 1 935 1,070 1 1,150 1,475 1 865 635 725 785 1 1,000 IBC, FL, MUS26' 0 x 1;295 :.1,480>" � 1,560 ' " -1,,560 :'i 930., ' Ij405 , 1;560 . ; , 7 -: :560 -; 'lsivt 955 ' ` 1;090., .1,180 su LA HUS26 1,320 2,735 3,095 3,235 3,235 1,320 2,960 31280 3:280 3,280 1,150 2,350 2,660 21780 2,780 HGUS2i3 . " 8i - j 4,340 4'1§50 ! ., 5,170 "; 5,390. 8+ " `; 4,690 5 220 -„5 390 , 5',390 ;. z 8C7 -. 3,225 „ 3,610 3;87,0 , ,3; 85 IBC, FL LUS28 1,165 1,100 1,260 1,350 1,725 1,165 1,195 1,360 1,465 1,730 865 810 925 1,000 1,270 ,. 1; 1;730" : hvUS28 ,i50 1, - ,d57 ' IBC FL, LA HUS28 1,760 4,095 4,095 4,095 4 O95 1,760 4,095 4 095 4.095 4,095 MIN . 3,520 3,520 3,520 3,520 'HGUS28 1,6 tl 7,275 ", 7;2?5 7,275 `; 7275' 1 650 7,275° ;7?7i-: _ 7275 7275 " 1.3c'5 3610" 3,820 ..'3,915` 4,250 `' IBC, FL LUS210 1,165 1,335 1,530 1,640 2,090 1,165 1,450 1,655 1,775 2,270 865 985 1,120 1,215 1,500 IBC, FL, HUS210; 2 °&4�0 5. ;, 9x£ Z830 53 °zw , ';, a4�9,5` 3 7ut , 83v r t ^0 ` Z 22i1 •• ,.2 33? 2 {5 2;.5215 J 2,825; •; LA HGUS210 2,090 9,100 9,100 G:100 9,100 2,090 9:100 ON 9, 01") 9,1O0 r ^ G �• 0,3 40 6,730 7 Fi,.30 -' •!1 6,.� hC; L 1. For dimensions and fastener information, see table above. See table footnotes on p. 195. HHUS/HGUS See Hanger Options information on pp. 98-99. HHUS - Sloped and/or Skewed Seat HHUS hangers can be skewed to a maximum of 45' and/or sloped to a maximum of 45' • For skew only, maximum allowable download is 0.85 of the table load£ - For sloped on or sloped and skewed hangers, the maximum allowable download P N P 9 is 0.65 of the table load �Y , • Uplift loads for sloped/skewed conditions are 0.72 of the table load, not to exceed 2,475 lb. • The joist must be bevel -cut to allow for double shear nailing JAcute side HGUS - Skewed Seat • HGUS hangers can be skewed only to a maximum of 45°. Allowable loads are: 00 HGUS Seat Width Joist Down Load Uplift Specify angle W < 2" Square cut 0.62 of table load 0.46 of table load Top View HHUS Hanger W < 2" Bevel cut 0.72 of table load 0.46 of table load Skewed Right 2" < W < 6" Bevel cut 0.85 of table load 0.41 of table load (joist must be bevel cut) 2" < W < 6" Square cut 0.46 of table load 0.41 of table load All joist nails installed the outside angle (non -acute side). W > 6" Bevel cut 0.85 of table load 0.41 of table load 94 LUS/MUS/HUS/HHUS/HGUS These products are available with For stainless Many of these products are approved for installation additional corrosion protection. ED steel fasteners, t with Strong -Drive° SD Connector screws. For more information, see p.15. see p. 21. See pp. 335-337 for more information. Double 2x Sizes LUS24-2 21%4' 18" - ° 3'/a, '3'/e , 2 • ' (4)°0:1'',6'2 X 3'Yz (2) 0.162'X ' 410 800: j .905' , 1980 " 11245 `355-"' -690 780 :'845 1,070 LUS26 2 -- ;4!fs 18 3 A 4 /s 2 ' - 4 0.162 x 3'h r) 4 0,162 X 3'/z O I,� �� 1 030: t 1701 11;265= (,595 - 910;. _- 885 " 1005 1,D9Q 1�,37Q' HHUS26-2 4% 14 3-516 53/a 3 (14) 0.162 x 31/2 (6) 0.162 x 31h 1,320 2,830 3,190 3,415 4,250 1,135 2,435 2,745 2,935 3,655 HGUS26-2 4s/ie 12 35A6 57AG 4 (20) 0.162 x 31/2 (8) 0.162 x 31/z 2,155 4,340 .4,850 5,170 5,575 1,855 3,730 .4,170 4,445 4,795 LUS28-2, - ' 49/6 18, "'31/a ° ° 7 2 (6) 0,162 x 31h - (4)'0.162 X 31h 560 1;315„ 1,49(7 .1 610 2,030 910', ':1,130 "1280 1,385 1,745 HHUM- ..1. 691a' 3 14" '3%, 71/4 `3 •(22J 0°162 x 3112;. (8) 6.162,x 31/2 - ,'i t60 4,265. 4,810' 5,155 5;980 't515 1670 A135 A.435 5J45 LUS210-2 6316 18 31/a 9 2 (8) 0.162 x 31/2 (6) 0.162 x 31/2 1,445 1,830 2,075 2,245 2,830 1:245 11,575 11,785 1,930 2,435 HHUS210-2 83/s 14 35/is 87A 3 (30) 0.162 x 31/2 (10) 0.162 x 3112.3:550 5,705 6,435 6,485 6.485 3,335 4,905 5,340 5060 5,190 HGUS210-2 8a/is 12 35fis 93/is 4 (46) 0.162 x 31h (16) 0.162 x 31/z 1 4,095 9,100 9,100 9,100 9,100 3,520 1 7,460 1 7,825 7,825 7,825 Triple 2x Sizes IBC, FL, LA rIUuJP073" 4k"IM J I IL !f ILUJ'�abLx"3'l2 i ttl�'UabL:X313 G;i�J, 434V.' 4n�U' J,I/U =�,.9,(� ,I,2fJD%'.,3,73U -4,1,/U !{,94 sF,1`JJ_I IBC,FL, HOUS28-3 'r � 6'% _ 12 415A 71/a 4 (36) 62.x 3f/ : (12)'0.162x31h- 3,235 .7,460 7,460" 7,460 .7,460 2,780 6,415 , 6,415 6,415 6,415 LA HHUS210-3 83/8 14 4111A6 87/a 3 (30) 0.162 x 31/2 (10) 0.162 x 3'h 3,405 5,630 6,375 6,485 16,485 2,930 4,840 5,485 5,575 5,575 FL HGUS210-3 81IA6 12 415A6 91/4 4 (46) 0.162 x 31/2 (16) 0.162 x 31/z 4,095 9,100 9,100 9,100 9,100 3,52#7,825 7,825 7,825 7,825 HGUS212=3"€ j ;105/n , ;' 12'" 4" 5/ig 1031d`" ,% (t.162 x 311z `:(20),0.162'�x 31/z 'S,59r ATV .5', , u �51 S �;9U � , p 0 x f72 _r �A1251e; 12 = :4i5fc 123%a' -,4 (66)0,162x3 h, (22) 0.162 x 31h 5695 10125 10,125 10,125 10;125 4,90 8;190 8;190 8,190' Quadruple 2x Sizes HGUS26 4' S'h ° 12 69As 57/1s 4 ` _ (20) 0162 x 31h 8) 0,162 X 31h , 2,155 4,340; 4,850. 5,170 .:5;575 1 855: If 3,730 , 4;770 4,445 4;795 IBC,. FL, HGUS28-4 71/4 12 6% 73/is 4 (36) 0.162 x 31h (12) 0.162 x 31/2 3,235 7,460 7,460 7,460 7,460 2,780 6,415 6,415 6,415 6,415 LA HHUS210-4 83/a 14 61A 87/a 3 (30) 0.162 x 31/2 (10) 0.162 x 31/2 3,405 15,630 6,375 6,485 6,485 2,930 4,840 5,485 5,575 15,575 1 FL 4x Sizes FAI IBC, FL, LA IBC, FL HHUS45 _" -' 016 14 3 ✓a '[5a 6 3=: (14),0.1621t 31/z ° i ,(6);0,162 X 31/z Q, , 3 f.2 830� 3190Y � 415': • 4;250 I 1 � n� 2 435, '�2 745 2,935, ;3,635� LUS48 43/a 18 39A6 63/4 2 (6) 0.162 x 31h (4) 0.162 x 31/2 1,060 1,315 1,490 1,610 2,030 910 1,130 1,280 1,385 1,745 IBC, FL, HUS48 6'/a 14 3afis 7 2 (6) 0.162 x 31h (6) 0.162 x 3Yz 1,320 1,580 1,790' 1,930 2,415 1;135 1,360 1,540 1,660 2,075 LA HHUS48 61/z 14 3% 71/a 3 (22) 0.162 x 31/2 (8) 0.162 x 31/2 1,760 4,265 4,810 5,155 5,980 1,5'(5 3,670 4,135 4,435 5,145 HGUS48 67/a 12 3% 71fs 4 (36) 0.162 x 31/z (12) 0.162 x 3'/2 3,235 7,460 7,460 7,460 7,460 2,780 6,415 6,415 6,415 6,415 L11S410 -.� 61/4 .! 18 �39A6 83/4 2 ; (8) 0.162 x'311i' (6)-0.162'x 31/: 4 . 1,830` 2 07,5' :2,245 2,830 1,245.' 1 575 =1,785 1,930 2,435' IS HHUS410'' 'i' 83/ ;: 14' 35/ 1 9 8t ,(30)'0.762x3'h,•{1b).0.162x31/z 15.s{ "5;705 6,435 e 485 O,48 '1 E�5",'4,905 `5535 u7� 3.575. HGUS410,. $7hs' ' 12" - 35/a 9tie 4 (46) 0.162 x 3'h . (16) 0162x 31h 4,0H5 9100 9100 9100 ,9,100 3,520 7,825 7,$25" 7,825 7,825- FL IB LA HGUS412 106 12 35/a 10346 4 (56) 0.162 x 31/2 (20) 0.162 x 31/2 5,695 9;045 9,045 9,045 9:045 4.900 7,780 ?,78^v f �80 7 780 HGUS414 11 % 12 3% 12346 4 (66) 0.162 x 31h (22) 0.162 x "' 5,695 10,125 10,125 10,125 10,125 4,900 8,190 8,190 8,190 8,190 Double 4x Sizes "WGIIC7,7-mn I Q74, '< 19. -73J: ,F9L. 'iA•: fA gvn 1 go v z 14r1 11 gi n'1 A9 v q 1/d gAQfI 1,61IOr o.nog I -a no4l ohor .9 oFni7 f19r1 iR7n- HGUS7.37/12-1 107ha > 12 73/a, 109is 4 . •(56}`0�162 k.3;t%i l (20),0162'k 31/a P3,835 9 295; 9 2950 9, 295,� 9,295 3,300 ;7995_, 7, 95 7,995 7,995 FL 'HGUS7.37/.14' �11 tis 1 12 -73/a' 12A. 4 ; {66),0.162 x'3?h' (22) 0:162 is 31h 5,080 10,50010 50010,50010,500 .4,370 9 030 9;030 9,030 9,036 1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 2. Wind (160) is a download rating. 3. Minimum heel height shown is required to achieve full table loads. For less than minimum heel height, see technical bulletin T-C-REDHEEL at strongtie.com 4. Truss chord cross -grain tension may limit allowable loads in accordance with ANSVTPI 1-2014. Simpson Strong -Tie® Connector Selector", software includes the evaluation of cross -grain tension in its hanger aflowable bads. For additional information, contact Simpson Strong -Tie. 5. Loads shown are based on a two-ply 2x carrying member minimum for nailed hangers. With 3x carrying members, use 0.162" x 21/2" nails in the header and 0.162' x 31h° in the joist, with no bad reduction. With single 2x carrying members, use 0.148" x 11/2" nails in the header and 0.148" x 3" in the joist, and reduce the load to 0.64 of the table value. 6. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. F= 19 Simpson Strong-TieO Wood Construction Connectors: Face -Mount Truss Hanger The HTU face -mount truss hanger has nail patterns designed specifically for shallow heel heights, so that full allowable loads (with minimum nailing) apply to heel heights as low as 37/a". Minimum and maximum nailing options provide solutions for varying heel heights and end conditions. Alternate allowable loads are provided for gaps between the end of the truss and the carrying member up to 1/2° max. to allow for greater construction tolerances (maximum gap for standard allowable loads is '/s" per ASTM D1761 and D7147). See technical bulletin T C-HANGERGAP at strongtie.com for more information. Material: 16 gauge i Finish: Galvanized ,0.. Installation: v • Use all specified fasteners; see General Notes • Can be installed filling round holes only, or filling U round and triangle holes for maximum values N • See alternate installation for applications L using the HTU26 on a 2x4 carrying member or HTU28 or HTU210 on a 2x6 carrying member for additional uplift capacity ca , d • HTU may be skewed up to 671/z°. See Hanger . Options on pp. 98-99 for allowable loads. • See engineering letter L-C-HTUSD at strongtie.com for installation with Strong -Drive® SD fasteners. Codes: See p.12 for Code Reference Key Chart Min. heel height per table Many of these products are approved for installation with Strong -Drive' SD Connector screws. See pp. 335-337 for more information. -7 HTU26 truss and carrying HTU Installation for Standard Allowable Loads (for 112° maximum gap, use Alternate Allowable Loads.) Standard Allowable Loads (1/8" Maximum Hanqer Gap) 2x Sizes SIMPSON St, fir. Typical HTU26 Minimum Nailing Installation Alternate Installation - HTU28 Installed on 2x6 Carrying Member (HTU210 similar) HTU28 (Min.) 37/s 15/a 7'A6 31/z (26) 0.162 x 31/z (14) 0.148 x 11h 1,235 3,820 3,895 3,895 3,895 1,00u., 1,060 ;.c uou. 2,865 I. f w wa° 2,920 : aE n t 2,920 .v ao�: 2,920 IBC, FL, HTU28 (Max.) 71/4 15/a 71f 6 31/z (26) 0.162 x 31h (26) 0.148 x 11h 2,020 3,820 4,315 4,655 5,435 1,735 3,285 3,710 4,005 4,675 LA HTt121b:(Min.). 371s;" 15/a,;alA6 ;31h° (32}"Oi62,x31h (1„4)fl148x1!W J,330';. ,300'=.'4,303 00 '- , of • 11453,22u;'J 225"i"3,225.! HTl)210 {Max;); , 9T/a °''; • 1.5/s ,9,1hs 3'Iz "(32)_Q f62 X 9Th ° .:{32) 014ax 1 3,31�,g 47Q5 ', �F�?1t} f 10 "5,�95, f 2 850° 4i1�5 ' nelf„^4,f3 Double 2x Sizes HTU26=2 (Min.) 37/a.: 35i6: 53ic ".31%z ,j(20}'0162 x 31/z (14) 0148'.x.3 1;515,,' �, 2,'940'. 0 `3,a1tC) `3;910 1;305 1,$50'' ,2,090 2,255 , p2 465;= 'HTU262(Mait;) ° 51Iz.,, .3 6"°°5?Is ,31h;-(20)0,162 t311z... ;(20)6.148.x3 2776 2,940;m3 2€ 3 BQ 4.48 . '1,870 2,534.-T2,Et ;Ofu3a'"3;855' HTU28-2 (Min.) 37/a 36/is 71f s 31/z (26) 0.162 x 31/z (14) 0.148 x 3 1,530 13,485 3,820 4,310 4,310 4,310 1,315 2,865 3,235 3,235, 3,235 IBC, HTU28-2 (Ma11 x.) 71/4 35/is 71ti6 31/z (26) 0.162 x 3Yz (26) 0.148 x 3 3,820 4,315 4,655 5,825 2,995 3,285 u '10 :4 fl5, t j0:; FL, LA 1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member. 2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch. 3. Uplift bads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 4. Wind (160) is a download rating. 5. For hanger gaps between 1h" and 1h", use the Alternate Allowable Loads. 6. Truss chord cross -grain tension may Emit allowable bads in accordance with ANSVTPI 1-2014. Simpson Strong-Tie`s Connector Selector° software includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong Tie. 7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148' x 1 W nails in the header and reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the tabb bad. ' 96 8. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. Z a 0 0 0 w F7 c5 z 0 cc r z 0 C. U) 0 rn 0 U Simpson Strong-TieO Wood Construction Connectors 01; L Face -Mount Truss Hanger (cont.) Many of these products are approved for installation with Strong -Drive® SD Connector screws. See pp. 335-337 for more information. Installation lable for 2x4 and Zxb Uarrying Member HTU26 (Min.) 37/a (2) 2x4 (10) 0.162 x 31/z (14) 0.148 x 11/z 925 1 1,470 1 1,660 1,790 1,875 795 1,265 1,430 1,540 1,615 HTU26 (Max.) 51/2 (2) 2x4 (10) 0.162 x 31h (20) 0.148 x 11/z 1,240 1,470 : 860 1,790, 2,220 1065 1,265 1,430 1,540 1,910 IBC, HTll2$ fMax.l 71/a 1212xF 'f f11 n 1R� x 1/ '(�Fi14h,14R x 1 �l 1 47(0' 9" 4dn - =3 _,>Ct rA6 ` ' ,q = 1,FQ ''� Fin I . n i n -'Z �Rfl FL, LA 1. See table above for dimensions and additional footnotes. 2. Maximum hanger gap for the alternative installation is'h". 3. Wind (160) is a download rating. 4. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. Alternative Allowable Loacls (112" Maximum Hanger U Single 2x Sizes HTU28 (Min.) 37/a 15/a 71A6 31/z (26) 0.162 x 31/2 (14) 0.148 x 1'/z 1,110 �,.- 3,770 3,770 3,770 3,770 955 2,825 I _,, 2,825 2,825 2,825 IBC, FL, HTU28 (Max.) 71A 15/s 7'fe 3'/z (26) 0.162 x 31/z (26) 0.148 x 11/2 1,920 3,820 3i5 4,655 5,015 1,695 2,865 3,235 3,49v 3,765 LA HT62i6(Mm`) '"' 77777 371s` "-7 5/a 9% 3'/z (32) 0162 x<3'/s '(1Aj�0��148 X , IW, 1250 3,600 ' 1075 �2 700' - 2,700 27a4 2 700' -,1 -4 9'fis 3'h-- (32} 0162-x 3?W (32} -148 x 1'h 3 255 4 705 'S,"02D 5,020. 5,020 2,800 ,3 53D 3,765 , 3 765 3 7W,' Double 2x Sizes HTU26 2 (Min' },' 3'/a 3�i6 5'h6 31h (20) 0162 x 3'%z {14} 0148 x3, ` 1515 , 2 940 I�Cs 3;500 3,500 1305 ; 2,205 2205 2 205 2 205 HTU26';2 (Max.):S 5'Iz 3 a 5Ttis 31W (20) 0162 x'31/z (20}10148 x 3 1,910 ,2 940 (, 3,5011 3 500 1645- "2 205 2,205 2 2,45 2 205 HTU28-2 (Min.) 31A 3-51. 71/ia 3'/z (26) 0.162 x 3'/z (14) 0.148 x 3 1,490 3,820 3,980 3,980 3,980 1,280 2,865 2,985 2,985 2,985 IBC, HTU28-2 (Max.) 71/4 35/ia 71/ia 31/z 1 (26) 0.162 x 31/z (26) 0.148 x 3 3,035 3,820 4,315 4,655 5,520 2,610 2,865 3,235 3,490 4:140 FL, LA 1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member. 2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch. 3. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 4. Wind (160) is a download rating. 5. For hanger gaps between 'A' and'W", use the Alternate Allowable Loads. 6. Truss chord cross -grain tension may Emit allowable bads in accordance with ANSUTPI 1-2014. Simpson Strong -Tie® Connector Selector° software includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie. 7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 11h" nails in the header and reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table bad. 8. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. HU/HUC/HSUR/L Medium -Duty Face -Mount Hangers HU/HUC hangers may be installed on a masonry/concrete wall as described below. Additionally, HU hangers with one flange concealed may be installed similarly. HU and HUG products are heavy-duty face -mount joist hangers made from 14-gauge galvanized steel. • The HUC is a concealed flange (face flanges turned in) version of the HU. • HU is available with both flanges concealed, provided the W dimension is 25/16" or greater, at 100% of the table load. Specify HUG. • HU is available with one flange concealed when the W dimension is less than 25/,6" at 100% of the table load. Specify as an `X' version and specify flange to conceal. • For any HU or HUG shown in this catalog, the user may substitute all face nails with 1/4" x 13/4" Titen® 2 screws (Model TTN2-25134H) for concrete and 3 4" x 2W' Titer) 2 screws (Model 71TN2-25234H1 for GFCMU. Follow all installation instructions and use the loads from tine sawn lumber or BNP sections. Material: 14 gauge Finish: Galvanized; ZMAX® and stainless steel available Installation: - - • Attach the hangers to concrete or GFCMU walls using hex -head Titen 2 screws. Titen screws for GFCMU (1/4" x 23/4" — Model TTN2-25234H) and for concrete (1/4" x 1 3/4' — Model TTN2-25134H) are not provided with the hangers. • Drill the 3/6"-diameter hole to the specified embedment depth plus 1/2". • Alternatively, drill the 3/,6"-diameter hole to the specified embedment depth and blow it clean using compressed air. • Caution: Oversized -diameter holes in the base material will reduce or eliminate the mechanical interlock of the threads with the base material and will reduce the anchor's . load capacity. • Titen Installation Tool Kts are available. They include a 3/,6" drill bit and hex -head driver bit (Model TTNT01-RC); a 3/16" x 41/2" drill bit is also available (Model MDB18412). • A minimum edge distance of 11/2" and minimum end distance of 37/e" is required as shown in Figure 1 for full uplift load. • VV'here no uplift load is required, a minimum end distance of 11/2" is permitted. Codes: See p.12 for Code Reference Key Chart Concealed flanges HUC410 SIMPSON ,: HU214 Figure 1 — HUC410 Installed on Masonry Block End Wall Figure 2 — HUC410 Installed on Masonry Block End Wall 23 HU/HUC/HSUR/L . ........... . . ........ . ..... . .... . .......................................... ............................................ ..................................... ............................... . . ........................ . . . .. . . . .. . ......................... .. . ............................................. Medium -Duty Face -Mount Hangers (cont.) - •J* These products are available with additional corrosion protection. For more information, see p. 15. .............. .... . Stantlard Concealed' GFCMU' Concrete.',,.' Tilen" 2 Joist 'Apli ,�160) (too.. Uplift "(16 01, Down . (1001 2 HU26 HU26X (4) 1/4 x 2 3/4 (4)1/4 x 13/4 (2) 0.148 x 11/2 335 1,000 335 1,545 ,HU28 X ,545_ (6 '/� xI 1/2­ - 54 5, i5OD " P �",��7601 �2,400 HU24-2 HUG24-2 (4)1/4 x 2 3/4 I (4)1/4 x 13/4 (2) 0.148 x 3 380 1,000 380 1,545 HU26-3 (Min.) HUC26-3 (Min.) (8) 1/4 x 2 3/4 (8) 1/4 x 13/4 (4) 0.148 x 3 760 2,000 760 3,200 HU26-3 (Max.) HUC26-3 (Max.) (12) 1/4 x 2 3/4 (12) 114 x 13/4 (6) 0.148 x 3 1,135 3,000 1,135 3,950 ­HO �ii-`2, Oin'.,)' HUC287 -2 X 23/4 (10), 114 X 13/4 500 -7M� 5""' 2 H 2,�2�(Max U 8 H q?8- x 8, -,A 920 HU210 HU210X (8) 1/4 x 2 3/4 (8) 1/4 x 1 (4) 0.148 x 1112 545 2,000 760 2,415 HU210-3 (Min.) HUC210-3 (Min.) (14) 1/4 x 2 3/4 (14) 1/4 x 13/4 (6) 0.148 x 3 1,135 3,500 1,135 4,920 HU210-3 (Max.) HUC210-3 (Max.) (18) 1/4 x 2 3/4 I (18) 1/4 x 13,4 (10) 0.148 x 3 1,800 4,500 1,800 5,085 MXI. "I I 3 x i 1. , , j HU212-2 (Min.) HU0212-2 (Min.) (16) 1/4 x 2 3/4 (16) 1/4 x 13/4 (6) 0.148 x 3 1,135 4,000 1,135 4,920 HU212-2 (Max.) HUC212-2 (Max.) (22) 1/4 x 23/4 (2 2) 114 x 13/4 (10) 0.148 x 3 1,350 5,085 1,350 5.085 H lz_�fflMax 17�� -j A1UtZIZ_.J,t[va�.) ' ­J��),��X�'14,_ K4) X-, 174 1 ­I�j k UY"j, '01 Z),kTjI'I HU214 HU214X (12) 114 x 21/4 (12) 114 x 13/4 (6) 0.148 x 11/2 1,135 2,665 11135 2,665 T-2 (Min' (18) 1/4 x `2' 1/4 '15 5 F HU214' 2 (Max.),, jM - ax (2�) 1/4 4 005, 2, 'Q1P_ 085 f" HU214-3 (Min.) HUC214-3 (Min.) (18) 1/4 x 2 3/4 (18) 114 x 13/4 (8) 0.148 x 3 1,515 4,500 1,515 5,085 HU214-3 (Max.) HUC214-3 (Max.) (2 4) 1/4 x 2 3/4 (2 4) 1/4 x 13/4 (12) 0.148 x 3 2,015 5,085 2,015 5,085 HU2161 = -HU216X x 23/4 (18)1/4 1- 1;1h 515 :�_2162'0 HU216-2 (Min.) HUC216-2 (Min.) (2 0) 1/4 x 2 3/4 (2 0) 1/4 x 13/4 (8) 0.148 x 3 1,515 4,920 1,515 4,920 HU216-2 (Max.) HUC216-2 (Max.) (26) 1/4 x 2 3/4 (2 6) 1/4 x 13/4 (12) 0.148 x 3 2,015 5,085 2,015 5,085 HU7 (Min.) (Not available) HU7 (Max.) (Not available) (12) 114 x 2 3/4 (12)1/4x1314 (4)0.148xll/2 545 1 2,980 1 760 2,980 (16) 1/4 x 2 3/4. I (16)1/4xl3/4 (8)0.14801/2 1,085 1 3,485 1 1,085 3,485 T,' dLJ9 {Max) (Notavailable)x 2�/, 4) 1 HU11 (Min.) (Not available) (2 2) 1/4 x 13/4 (6) 0.148 x 11/2 1,135 3,230 1,135 3,230 HU11 (Max.) (Not available) (3 0) 1/4 x 2 �14 1 (3 0) 1/4 x 1 -/, 1 (10)0.14801/2 1 1,445 3,735 1,445 3,735 38 fl STAGGER JOINTS - TYP. RAISED HEEL ROOF TRUSSES B/SKIfT LAN UPLIFT/SHEAR ANC r i IBBON BOARD- SEE CHEDULE FOR SPACING t ASTENING TO TRUSSES WALL - EACH TRUSS -SEE 5/SKI SEE SEE PLAN PLAN NOTE: ADVL FRAMING NOT SHOWN FOR CLARITY RAISED HEEL TRUSS BEARING A SCALE: NTS SKI ' I' i, ` r ■I_I■■I.I a�a�aa�a�aa� ROOF SHEATHING- SEE 6OFFIT/FA5CIA- SEE ARO RAISED HEEL ROOF TRUSSES -SEE PLAN W N RIBBON BOARD - SEE SCHEDULE, FOR SPACING d FASTENING TO w N TRUSSES WALL SHEATHING -SEE PLAN MIN. 15/32' CDX PLYWOOD OR i 1/I6' OSB WITH 8d GUN NAILS (0.131' X 2 1/2') 0 6' O.C. TO UPLIFT/SHEAR GYP. CEILING - RIBBON BOARDS ANCHOR EACH SEE PLAN a TRU55- SEE PLAN SCHEDULE DO NOT FASTEN RIBBON BOARD INTOWALL INTO END GRAIN OF ROOF TRUSS - BOTTOM CHORD SEE PLAN RAISED HEEL TRUSS BEARING B SCALE: NTS SKI RIBBON 5GHE[DULEc DESIGN CRITERIA RIBS N MATERIAL RIBBON SPACING RIBBON ATTACHMENT vult=165 MPH (2).12d GUN (0.131' X 31) (Vasd=125 MPH) 2-'4 SPF02 24' TO EACH TRUSS, (4) EXP. B, ENCLOSED ! NAILS AT JOINTS VUIL=180 MPH I 12112d GUN ( (Vasd=139 MPH) 2 �4 5PF�1 Ib' (S, 4) TO EACH TRUSS, EXP. C; ENCLOSED NAILS AT JOINTS rd� wa54.B SK.1 January,l.,Q,,2'ff2O- .0 . atpoiftet.Ccintractiort dA, rh&fica-, Inc... 3900 Avenue G, NW Wiriter...B06n, FL,338,86,:-62°QA Dear Mafia; It"has mOlt6myattention -:ihatsomequestions were raised; concerning . ]8,," didiriet&r ho!46sifl- t3h' fti- t'h*&,c.'h:o:f&'(W.-'id& fiwEi) of sy.s,Q ga,bleend trusses o gllow for, threaded tbd§ ii8ed fdr If' hese:kable,endsare over continuous s,!Apppw, face aglng".,any connector phit&s, "or -wrtical ,webs thep: n ,rep -a. rj�peq_jr truss pbrrts;.-��; f, - t- -f q-1 -."j;: . d'. o, i required e�e 0, .00.r ca! san dddftioinal load.. If you, ha"ve", any questions;, please give me a;.call �,�``�,�1NW�1tr�rf���f Q 0750 Forum .Drive, Syite, Orlando, P,nd,pl, FL 3282.1'- (OQQ) 521 -Q7QO,--{863),422-,8O85 eitw-.com. m"'004, , n, I il. - I 7hs dxurent hfabeen dectronicaW sJWwd and seated using a Uigft SweUs. fltintod copies ioviftiA an on and siW�atro nwst by Yefilledusing" original elecT mc1fersfon. COA #0 278 03/10/2021 Sao. 70M 1 ,. SATE ALPINE AW aw coMPANY Alpine, an ITW Company 6750 Forum Drive, Suite 305 Orlando, FL 32821 Phone: (800)755-6001 www.alpineitw.com F x Custorrieri Carpenter -Contractors of America Job Number. N334504 Job Description: 7A5/320 ,182ED,F ,02G ,Rl01 / 1828/CAL114EBB ELEV.D/F Address Jdh'ia ineErdn Criteax . Nr , Design Code: FBC 7th Ed. 2020 Res Inte1/iVIEW Version: 20.02.00A JRef'#° 1 XX89750176 Wind Standard: ASCE 7-1.6 Wind Speed (mph): 160 Design Loading (pso. 37.00 Building Type: Closed This ,package contains general notes pages, 29 truss drawing(s) and 5 detail(s);, 1 069.21.1632,52209 Al 3 069.21.1632.52741 A3 5 069.21.1632.52180 A5 7 069.21.1632.52444 A6' 9 069.21.1632.52569 A10 11 069.21.1632.52554 A14G 13 069.21.1632.52803 B2GE 15 069.21,1632,52631 C2G'E 17 069.21.1632.52820 D2 19 069.21.1632 52600 V4 2.1 069.21.1632.52538 EJ7 23 069.21.1632.52882 EJ3 25 069.21.1632.52898 CJ5 27 069.21.1632..52743 CA 29 06921.1632.52709 HJ3A '.i1 GBLLETIN011'8 33 VAL1`80160118 2; 069.21.1682.52492 AM 4 069.21,1632.52242 A4 6 069.21.1632,52632 A5GE 8 069.21.1632.52194 A8 10 069.21.1632.52459 Al2 12' 069.21,1632.52210 131 14 069.21.1632.52241 C1'. 16 069,21.1632.53054 D1 18 069.211632.52944 D3G 20 069,21.1632.52975 V8 22 069.21.1632.52867 EJ7A 24 069.21.1632.52195 EJ2 26 069.21.1632.52928 CJ3 28 069,21.1632.52522 HJ7 30 A16015ENC160118 32 CNNAILSP1014 34 VALTNI60118 Florida Certificate of Product Approval #FL1999 Printed 3/10/2021 4:3527 PM T General Notes Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities: The design responsibilities assumed in the preparation of these design drawings are those specified in ANSI/TPI 1, Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design Specification for Wood Construction by AWC. The truss component designs are based on the specified loading and dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to independently verify the accuracy or completeness of the information provided by others and may rely on that information without liability. The responsibility for verification of that information remains with others neither employed nor controlled by the Truss Design Engineer. The Truss Design Engineer's seal and signature on the attached drawings, or cover page listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component designs and not for the technical information furnished by others which technical information and consequences thereof remain their sole responsibility. The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and loads for each truss component match those required by the plans and by the actual use of the individual component, and for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any additional factors required in the particular application. Truss components using metal connector plates with integral teeth shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to exceed 19% and/or cause corrosion of connector plates and other metal fasteners. The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted work set forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss component design loads, inspection of the truss components before or after installation, the design of temporary or permanent bracing and their attachment required in the roof and/or floor systems, the design of diaphragms or shear walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports, installation of the truss components, observation of the truss component installation process, review of truss assembly procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in the installation of the truss components and/or its connections. This document may be a high quality facsimile of the original engineering document which is a digitally signed electronic file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request. Temporary Lateral Restraint and Bracing: Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2, B7 and/or B10 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to and may not be relied upon for the temporary stability of the truss components during their installation. Permanent Lateral Restraint and Bracing: The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of BCSI chapters B3, B7 and/or B10, or as specified by the Building Designer or other Registered Design Professional. These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building stability bracing which are parts of the overall building design to be specified, designed and detailed by the Building Designer. Connector Plate Information: Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel with the following designations, gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; S=Super Strength, 18ga, grade 60. Information on model code compliance is contained in the ICC Evaluation Service report ESR-1118, available on-line at www.icc-es.org. Fire Retardant Treated Lumber: Fire retardant treated lumber must be properly re -dried and maintained below 19% or less moisture level through all stages of construction and usage. Fire retardant treated lumber may be more brittle than untreated lumber. Special handling care must be taken to prevent breakage during all handling activities. Page 1 of 3 General Notes (continued) Key to Terms: Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be found in calculation sheets available upon written request. BCDL = Bottom Chord standard design Dead Load in pounds per square foot. BCLL = Bottom Chord standard design Live Load in pounds per square foot. CL = Certified lumber. Des Ld = total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot. FRT = Fire Retardant Treated lumber. FRT-DB = D-Blaze Fire Retardant Treated lumber. FRT-DC = Dricon Fire Retardant Treated lumber. FRT-FP = FirePRO Fire Retardant Treated lumber. FRT-FL = FlamePRO Fire Retardant Treated lumber. FRT-FT = FlameTech Fire Retardant Treated lumber. FRT-PG = PYRO-GUARD Fire Retardant Treated lumber. g = green lumber. HORZ(LL) = maximum Horizontal panel point deflection due to Live Load, in inches. HORZ(TL) = maximum Horizontal panel point long term deflection in inches, due to Total Load, including creep adjustment. HPL = additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds. Ic = Incised lumber. FJ = Finger Jointed lumber. L/# = user specified divisor for limiting span/deflection ratio for evaluation of actual Udefl value. L/defl = ratio of Length between bearings, in inches, divided by the vertical Deflection due to creep, in inches, at the referenced panel point. Reported as 999 if greater than or equal to 999. Loc = Location, starting location of left end of bearing or panel point (joint) location of deflection. Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for of all load cases. Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for of all load cases. Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for of all load cases. NCBCLL = Non -Concurrent Bottom Chord design Live Load in pounds per square foot. PL = additional Load applied at a user specified angle on a truss Piece in pounds per linear foot or pounds. PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or pounds PLT = additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds. PP = Panel Point. R = maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc). -R = maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc). Rh = maximum horizontal design Reaction in either direction, in pounds, from all specified gravity load cases, at the indicated location (Loc). RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). Rw = maximum downward design Reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the identified location (Loc). TCDL = Top Chord standard design Dead Load in pounds per square foot. TCLL = Top Chord standard design Live Load in pounds per square foot. U = maximum Upward design reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in inches. VERT(CTL) = maximum Vertical panel point deflection ratios due to Live Load and Creep Component of Dead Load, and maximum long term Vertical panel point deflection in inches due to Total load, including creep adjustment. VERT(LL) = maximum Vertical panel point deflection in inches due to Live Load. VERT(TL) = maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment. W = Width of non -hanger bearing, in inches. Refer to ASCE-7 for Wind and Seismic abbreviations. Uppercase Acronyms not explained above are as defined in TPI 1. Page 2 of 3 References: 1. AWC: American Wood Council; 222 Catoctin Circle SE, Suite 201; Leesburg, VA 20175; www.awc.org. 2. ICC: International Code Council; www.iccsafe.org. 3. Alpine, a division of ITW Building Components Group Inc.: 514 Earth City Expressway, Suite 242, Earth City, MO 63045; www.alpineitw.com. 4. TPI: Truss Plate Institute, 2670 Crain Highway, Suite 203, Waldorf, MD 20601; www.tpinst.org. 5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719; www.sbcindust[y.com. Page 3 of 3 SEQN: 250001 / COMN Ply: 1 FROM: RWM Qty: 16 6'1"7 6'1"7 Job Number: N334504 ,7A5/320 ,182ED;F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F Truss Label: Al 12'1115 i 19,10" 26'8"1 W1,08 6'10"1 + 6'10"1 = 5X5 E �'T 10' 10' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.97 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W4,W5 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 47-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 39'8" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020.Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): 0 9'10" 29'8" Cust:R8975 JRef:1X3L89750176 T10 DrwNo: 069.21.1632.52209 TCE / YK 03/10/2021 33'69 39'8" 6'10"8 6'17 Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.222 K 999 240 VERT(CL): 0.385 K 999 240 HORZ(LL): 0.081 J - - HORZ(TL): 0.140 J Creep Factor: 2.0 Max TC CSI: 0.617 Max BC CSI: 0.882 Max Web CSI: 0.457 VIEW Ver: 20.02.00A.1020.20 ,� r .� w• `r i► �°� �t 03/10/2021 10, 1' 39-13" ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 1711 /- /- /961 /309 /444 H 1711 /- /- /961 /309 /- Wind reactions based on MWFRS ,B Brg Width = 8.0 Min Req = 2.0 H Brg Width = 8.0 Min Req = 2.0 Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1490 - 3155 E - F 1130 - 2029 C - D 1366 - 2875 F - G 1366 - 2875 D - E 1130 - 2029 G - H 1490 - 3155 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - L 2759 -1207 K - J 2278 - 858 L - K 2278 - 879 J - H 2759 -1186 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. L - D 541 -134 K - F 530 - 745 D - K 530 - 745 F - J 541 -134 E - K 1362 - 605 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Joint9Details, unless noted otherwise. f�efer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not. be responsible for any deviation from this drawing, any. failure to build the ANMCOWAW truss in conformance with ANSI/TPI 1, or for handling, shipping,. installation and bracing of trusses: A seal on this drawn or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of professional en sneering responsibility solely -for the design shown. The suitabilioy and use of This Suite Fos drawing for any sfructure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN:250030/ COMN Ply: 1 Job Number: N334504 Cust:R8975 JRef:1X3L89750176 T25 / FROM: ALS Qty: 1 , A5/320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52492 Truss Label: A1A �TCE / YK 03/10/2021 7'11 "2 T11"2 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.97 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; T1 2x4 SP #1; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; W3,W6,W9,W11 2x4 SP #2 N; Bracing (a) 1 X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.1280" gun nails @ 6" oc. Plating Notes All plates are 2X4 except as noted. (1) - plates so marked were sized using 0% Fabrication Tolerance, 0 degrees Rotational Tolerance, and/or zero Positioning Tolerance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. * The 5-0-0 section of Bottom Chord at 8-8-0 elevation between panel points R and N may be field -removed as required provided that all remaining plate/wood contact areas stay intact and undisturbed. 12' 17'1"12 19'8"410"i 23'8" 4'0„14 f 51"12 2'310" 3,9"3 1 2'1"12 3' 11'10"4 14' 17' Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): =6X6 F 39'8" 31'814 39'8" 8'0"14 7'11"2 68" + 80"11 23'8" 31'8"11 Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.386 O 999 240 VERT(CL): 0.669 O 706 240 HORZ(LL): 0.168 K - - HORZ(TL): 0.314 K Creep Factor: 2.0 Max TC CSI: 0.791 Max BC CSI: 0.896 Max Web CSI: 0.765 JE. HS (VIEW Ver: 20.02.00AA020.20 Laterally brace Bottom Chord above filler at 24" oc, including a lateral brace at chord ends (Not required if 5-0-0 section of lower Bottom Chord is removed as noted (*)). " •F l ♦ �+mm®aoae r� °°"r 03/10/2021 7'11"5 1' ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 1556 /- /- /961 /309 /444 1 1556 /- /- /961 /309 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 2.2 1 Brg Width = 8.0 Min Req = 2.2 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1410 - 2745 F - G 1410 - 2068 C - D 2144 - 4245 G - H 1218 - 2103 D - E 1499 - 2794 H - 1 1423 - 2777 E - F 1658 - 2771 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - S 2371 -1107 L - K 2402 -1107 Q - M 3738 -1614 K - 1 2406 -1106 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C - S 814 -1523 M - F 2007 -1008 C - Q 1476 - 551 M - L 1864 - 604 S - Q 2850 -1327 F - L 492 - 506 Q - D 1271 - 562 L - G 452 - 368 D - M 825 -1539 L - H 475 - 688 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for of lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or 1310, as applicab-le. Apply plates to each face. o truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to A LPI N E drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing, any. failure to build the ANnW COMVANY truss in conformance with ANSI 1, or for handling, shipping,. installation. and bracinqqof trusses. A seal on this drawin or cover pa a 675o Forum Drive listing this drawing indicates acceptance of professional engineering responsibilitty� solely -for the design shown. The suitability and use of This drawing for any structure is the responsibility of the Building Designer per ANSI/TP1 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.cr ; SBCA: sbcindust .com; ICC: iccsafe,or ; AWC: awc.org Orlando FL, 32821 SEQN: 250031 / COMN Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1X3L89750176 T2 / FROM: RWM Qty: 1 7A5/320 ,182ED,F ,02G ,RIO1 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52741 Truss Label: A3 1 YK 03/10/2021 6'1"7 121115 19'10" 244" 33'6"9 6'1"7 610"8 6'10"1 4'6" 9'2"9 6'1"7 =5X5 E Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.97 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wnd Duration: 1.60 Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #1; B3,B4 2x4 SP #2 N; Webs: 2x4 SP #3; W3,W4,W5,W7 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. B3 1114X4 20'8" i5181,i 13'4" 9110.. 4'6" 5'4" 19'10" 24'4" + 29'8" Snow Criteria' (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.033 M 999 240 VERT(CL): 0.082 M 999 240 HORZ(LL): 0.011 L - - HORZ(TL): 0.024 C - Creep Factor: 2.0 Max TC CSI: 0.961 Max BC CSI: 0.737 Max Web CSI: 0.420 Ver: 20.02.00A.1020.20 COA summoN 03/10/2021 u> o 10, 1' 39'8" ♦Maximum Reactions (Ibs), or*=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 871 /- /- /610 /172 /444 N* 247 /- /- /156 /73 /- H 508 /- /- /427 /147 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 N Brg Width = 68.0 Min Req = - H Brg Width = 8.0 Min Req = 1.5 Bearings B, N, & H are a rigid surface. Bearings B & H require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 606 -1330 G - H 246 - 579 C - D 479 -1037 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - M 1138 - 532 K - J 952 - 498 M - L 691 - 320 J - H 484 -143 L-K 967 -518 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C - M 375 - 360 K - F 885 -1188 M - D 558 -150 F - J 573 - 255 D - L 559 - 715 J - G 495 - 484 L - F 769 - 272 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of SCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper!v attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10 as applicable. Apply piates to each face oT truss and position as shown above and on the Join Details, unless noted otherwise. Defer to A L Adkhk, N E drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin$Components Group Inc. shall not,be responsible for any deviation from this drawing, any failure to build the ANMCCWA truss in conformance with ANSI/l PI 1, or for handling, shipping,. Installation and bracing of trusses. A seal on this drawing or cover page 6750 Forum Drive listing this drawingg indicates acceptance of professional en Ineering responsibili(t�� solely -for the design shown. The suitability and use of This drawing for any sfr'ucture is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com• ICC: iccsafe.org; AWC: awc.org Orlando FL, 32821 SEQN: 250032 / HIPS Ply: 1 Job Number: N334504 Cust: R 8976 JRef:1X3L89750176 T9 / FROM: RWM Qty: 1 ,7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F Dnallo: 069.21.1632.52242 Truss Label: A4 SSB / WHK 03/10/2021 6-1 "7 12'615 + 19, 6'S"8 6'5"1 � 10 10' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.97 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Sot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W4,W5,W6 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. :5X5=5X5 E F 39'8" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/l 0(0) Plate Type(s): WAVE 27'1"1 6'S"1 9.10" Defl/CSI Criteria PP Deflection in ]cc L/defl U# VERT(LL): 0.172 L 999 240 VERT(CL): 0.321 L 999 240 HORZ(LL): 0.066 K - - HORZ(TL): 0.123 K - Creep Factor: 2.0 Max TC CSI: 0.480 Max BC CSI: 0.747 Max Web CSI: 0.625 VIEW Ver: 20.02.00A.1020.20 �..,.- o i � ••yr%P Bd�lA�fdfPl �y gpawaamss��' 6j^�f ''r�� ®® o.70$ I 0 s a a °a a „ a®,T 0 a ZYe�Oem�ia, CON IONA 03/10/2021 33'6"9 39'8" 6'5"8 6'1'7 10' 1' 39'"8+ ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 1556 /- A /963 /310 /427 1 1556 /- /- /963 /310 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.8 I Brg Width = 8.0 Min Req = 1.8 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1542 - 2800 F - G 1182 -1779 C - D 1425 - 2521 G - H 1425 - 2521 D - E 1182 -1779 H - 1 1542 - 2800 E - F 1159 -1559 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - M 2444 -1262 L - K 2030 - 937 M - L 2030 - 957 K - 1 2444 -1241 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M - D 508 -119 L - F 548 - 356 D - L 521 - 683 ' L - G 521 - 683 E - L 548 - 356 G - K 508 -119 *`WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS sses require extreme care in fabricating, -handling shipping, installing and bracing.. Refer to and follow the latest edition of BCSI (Building nponent Safety Information, by TPI an 'SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary ing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly ched rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10. applicabge. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to Brings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ine, a division of ITW Build inj Components Group Inc. shall not. be responsible for any deviation from this drawing, any, failure to build the s in conformance with ANSI/ PI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawing or cover page ng this drawing indicates acceptance of professional engiineenng responsibili�v solely -for the design shown. The suitabiliff' and use of This ,ving for any structure is the responsibility of the Building -Designer per ANSI/T 11 Sec.2. more information see these web sites: Alpine: aloineitw.com: TPI: toinst.oro: SBCA: shcindustrv.com: ICC: iccsafe.oro: AWC: awc ora LAME COWAW - 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN:250033! HIPS Ply: 1 Job Number: N334504 Cust:R8975 JRef:1X3L89750176 T8 / FROM: RWM City: 1 ,7A5l320 ,182ED,F ,02G ,RI01 / 1828/CAL1/4EBB ELEV.D/F DrwNo: 069.21.1632.52180 Truss Label: A5 �SSB / WHK 03/10/2021 7'10"14 1 17' ')' 22'6" 7'10"14 9'1"2 5'8" :5X5 =5X5 D E 39'8" 10: 1' 9.10" I' r 1019,10" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) TCLL: 20.00 Wind Sid: ASCE 7-16 Pg: NA Ct: NA CAT: NA TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA BCLL: . 0.00 Enclosure: Closed Lu: NA Cs: NA BCDL: 10.00 Risk Category: II Snow Duration: NA - EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Building Code: Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): Wind Duration: 1.60 WAVE Lumber Top chord: 2x4 SP #2 N; T2,T4 2x4 SP 2400f-2.OE; Bot chord: 2x4 SP #1; Webs: 2x4 SP #2 N; W1,W6 2x4 SP #3; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 31'9"2 + 39'8" 9'1"2 7'10"14 9.10" 29'8" Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0:149 J 999 240 VERT(CL): 0.279 J 999 240 HORZ(LL): 0.060 1 - - HORZ(TL): 0.112 1 Creep Factor: 2.0 Max TC CSI: 0.760 Max BC CSI: 0.755 Max Web CSI: 0.989 VIEW Ver: 20.02.00A.1020.20 . 'y4 C 0. 708 1 i D ° 0 Q q S 0 C0A%7�rQ�- ��,• 03/10/2021 i 10' 1' ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 1552 /- /- /965 /318 /386 G 1552 /- /- /965 /318 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.8 G Brg Width = 8.0 Min Req = 1.8 Bearings B & G are a rigid surface. Bearings B & G require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1673 - 2755 E - F 1699 - 2561 C - D 1698 - 2561 F - G 1674 - 2755 D - E 1352 -1728 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - K 2393 -1373 J - 1 1695 - 842 K - J 1695 - 863 I - G 2393 -1352 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - K 498 -448 E - 1 770 -435 K - D 770 - 435 I - F 498 - 448 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r satPety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have propersv attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply Oates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildingc� Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the AN mvmAmANv truss in conformance with ANSI PI -1, or for handling, shipping,. installation and bracing of trusses. A seal.on this drawin or cover page 675o Forum -Drive listing this drawing indicates acceptance of professional enc�meenng responsibilittyy solely -for the design shown. The suitability and use of This drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: aloineilw.com: TPI: toinst.oro: SBCA: sbcindustrv.com: ICC: iccsafe.ora: AWC: awc.cra Orlando FL, 32821 SEQN: 250065 / COMN Ply: 1 1 Job Number: N334504 Cust: R 8975 JRef:1X3L89750176 T11 ! FROM: RDP Qty: 1 7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52632 Truss Label: A5GE / YK 03/10/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " �1711'15 11'4 "H�'6'2 .3'15 4 ' 1 2 517 9'10' 1 '3' 1910' 21' 31'10'7 3'9' 39'0' 9 r� 1 t 2 2 ;) 7aT91� �1rrj ,= 10'8' r7-I 05K9 K F7' 10' 111'4 1712 5' 3'9' T 10' 19'9'4 27 25' Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.97 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W7,W14,W15,W16 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2ff%min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 56 plf at -1.00 to 56 plf at 10.67 TC: From 76 plf at 10.67 to 76 plf at 32.67 TC: From 56 plf at 32.67 to 56 plf at 40.67 BC: From 20 plf at 0.00 to 20 plf at 39.67 BC: 128 lb Conc. Load at 23.21,23.79 PL: 136 lb Conc. Load at (23.27, 9.98), (23.80.9.98) Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS with additional C&C •member design. Wind loading based on both gable and hip roof types. 21'11"12 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:20(0)/10(0) Plate Type(s): -! 13712 -I Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.106 AE 999 2, VERT(CL): 0.211 AE 999 2, HORZ(LL): 0.044 1 HORZ(TL): 0.088 1 - Creep Factor: 2.0 Max TC CSI: 0.646 Max BC CSI: 0.645 Max Web CSI: 0.957 Ver: 20.02.00A.1020.20 a a e h � s y w COA 03/10/2021 ♦Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 769 /- /- /504 /323 /444 AS 2335 /- /- /945 /990 /- Z 1079 /- !- /484 /352 A T 519 /- A /398 /219 A Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 AS Brg Width = 8.0 Min Req = 2.8 Z Brg Width = 8.0 Min Req = 1.5 T Brg Width = 8.0 Min Req = 1.5 Bearings B, AB, Z, & T are a rigid surface. Bearings B, AB, Z, & T require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C . 465 -1090 I - J 391 -195 C - D 335 - 815 J - K 390 -199 D - E 399 - 762 K - L 536 - 262 E - F 411 - 759 L - M 608 - 296 F - G 397 - 678 M - N 506 - 244 H - 1 377 -185 S - T 228 - 610 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B -AH 922 -479 AA- Z 375 -227 AH-AG 486 -261 Z - Y 388 - 286 AG-AF 486 -261 Y - X 388 - 286 AF-AE 486 -261 X - W 491 -156 AE-AD 486 -261 W - V 491 -156 AD -AC 486 -261 V - T 491 -156 AC -AB 479 -325 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. AH-AI 518 -256 AB -AR 304 -482 AI-AJ 555 -273 AR -AS 445 -568 AJ-G 519 -269 AW-Z 272 -747 G -AL 514 - 933 AW- N 237 - 676 AL -AN 498 -920 N -AX 683 -357 AN -AP 519 -955 AX-X 690 -352 AP -AC 540 - 984 X -AZ 301 - 478 AC- K 792 -505 AZ -BB 275 -472 K -AB 546 -1366 BB- S 326 - 457 **WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections 83, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildinlComponents Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the ANRWCOMVANV truss in conformance with ANSI/I PI 1, or for handling, shipping,, Installation and bracing4 of trusses. A seal on this drawin or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional encLmeering responsibility solely -for the design shown. The suitability and use of This drawing for any s9r'ucture is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250035 / HIPS Ply: 1 Job Number: N334504 Cust: R 8975 JRefAX3L89750176 T7 / FROM: RWM Qty: 1 ,7A5/320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52444 Truss Label: A6 �SSB / WHK 03/10/2021 7'10"14 15, 24'8" 31'9"2 39'8" 7'10"14 7'1 "2 9'8" Tl "2 7'1014 6X6 = 6X6 D T3 E 10, 10, 91101, 19,10" 39'8" 10, 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.159 J 999 240 Loc R+ / R- / Rh / Rw / U / RL B 1562 /- /- /962 /328 /346 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.298 J 999 240 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.061 1 - - G 1552 A /- /962 /328 /- Des Ld: 37.00 EXP: C Kzt: NA Mean Height: 15.00 ft HORZ(TL): 0.115 I - - Wind reactions based on MWFRS NCBCLL: 10.00 TCDL: 4.2 psf Building Code: Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.913 G Brg Width = 8.0 Min Req = 1.8 Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Sid: 2014 Max BC CSI: 0.760 Bearings B & G are a rigid surface. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.474 Bearings B & G require a seat plate.Members Loc. from endwall: not in 9.00 ft FTlRT:20(0)/10(0) not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 20.02.00A.1020.20 Wind Duration: 1.60 WAVE o n "unwer C - D 1826 - 2538 F - G 1807 - 2729 Top chord: 2x4 SP #2 N; T3 2x4 SP 2400f-2.OE; D - E 1539 -1910 Bot chord: 2x4 SP #1; Webs: 2x4 SP #2 N; W1,W6 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Wind Chords Tens.Comp. Chords Tens. Comp. Wind loads based on MWFRS with additional C&C B - K 2363 -1483 J -1 1847 -1110 member design. K - J 1847 -1131 I - G 2363 -1462 Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - K 394 - 358 E - 1 628 - 300 K - D 628 - 300 1 - F 394 - 358 ��gyts►staurarrrr/a % e � r 9 A. COAb;910'NsumnioOee'/7`. 03/10/2021 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply Oates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the ANMCOW— truss in conformance with ANSI/l PI 1, or for handling, shipping,. Installation and bracingof trusses. A seal on this drawin or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibilit�yy solely -for the design shown. The suitability and use of this drawing for any s9r'ucture is the responsibility of the Building -Designer per ANSI/Tr 11 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.orq Orlando FL, 32821 SEQN: 250036/ HIPS Ply: 1 Job Number: N334504 Cust: R8975 JRef:1X3L89750176 T6 / FROM: RWM Qty: 1 7A5/320 ,182ED,F ,02G ,RIO1 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52194 �SSB Truss Label: A8 / WHK 03/10/2021 6'9"4 13' 19'10"32'10"12 39'8" 6'9"4 6'2"12 6'10" 6'10" 6'2"12 6'9"4 :5X5 1112X4 ; 5X5 D E F 12 6 'k2X4 W C 62X4 o, o_ G Un 'O W3 B A H I �88 4X6(A2) -5X5 =5X8 =5X5=4X6(A2) 39'8" 10' 9'10" 9110.. 10, 1'. 10' 19,10" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.191 E 999 240 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.357 E 999 240 B 1556 A A /953 /716 1305 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.065 J - - H 1556 A A /953 /716 /- EXP: C Kzt: NA Des Ld: 37.00 HORZ(TL): 0.121 J - - Wind reactions based on MWFRS Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Building Code: Creep Factor: 2.0 B Br g Width = 8.0 Min Req = 1.8 Soffit: 0.00 BCDL: 5.0 FBC 7th Ed. 2020 Res. Max TC CSI: 0.543 psf H Brg Width = 8.0 Min Req = 1.8 Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.754 Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.687 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 2014 -2780 E - F 1973 -2289 Top chord: 2x4 SP #2 N; C - D 1925 - 2523 F - G 1925 - 2523 Bot chord: 2x4 SP #1; D - E 1973 - 2289 G - H 2O14 - 2780 Webs: 2x4 SP #3; W3,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Wind Chords Tens.Comp. Chords Tens. Comp. Wind loads based on MWFRS with additional C&C B - L 2421 -1686 K - J 1982 -1323 member design. L - K 1982 -1344 J - H 2421 -1665 Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - L 381 - 339 K - F 425 - 401 L - D 535 -183 F - J 535 -183 D - K 425 - 401 J - G 381 - 339 yytts►satslssvrtrarytrrof E - K 585 -391 0 $ 4 0. US 1 S s Y s o �1qy. �gpgg� }per] .� Ri :ilIONAL ` COA# (3/10/2021 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI andSBCA) r safety to these functions. Installers temporary practices prior performing shall provide bracing per BCSL Unless noted otherwise, top chord shall have propeg attached structural sheathing and bottom chord shall have a properly attached rigid ceilin Locations shown for lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, of as applicable. App�y plates to each face o truss and position as shown above and on the Join Details, unless noted otherwise. Refer to drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW Buildin$gComponents Group Inc. shall not, be responsible for any deviation from this drawing,.any failure to build the ANMCOMVANV truss in -shipping,, conformance with ANSI 1, or for handling, lnstallatlon and bracin of trusses. A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional encLmeering responsibility solely -for the design shown. The suitability and use of This drawing for any structure is the responsibility of the Building -Designer per ANSI/TXI 1 Sec.2. Suite 305 For more information see these.web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250037 / HIPS Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1X3L89750176 T5 / FROM: RWM Qty: 1 7A51320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52569 Truss Label: A10 SS I / WHK 03/10/2021 5'9"4 11' 19' 28'8" 33'10"12 39,8" 5'94 5'2 -12 8' 9'8" 5'2"12 5'9"4 _5X5 =5ET35 �5X5 D F T 12 6 ,2C4 W 2X4 b (a) (a) G u7 rn W3 io io B A H 3� I 4X6(A2) _ L _ K =5X5 =5X8 =5X5 J 4X6(A2) 39'8" 10' 9'10" 9'10" 10 1 10' 19'10" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.213 E 999 240 LOC R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.399 E 999 240 B 1556 /- !- /940 1718 l264 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.068 J - - H 1556 A /- /940 f718 A EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft HORZ(TL): 0.127 J - - Wind reactions based on MWFRS NCBCLL: 10.00 Building Code: Creep Factor: 2.0 TCDL: 4.2 psf B Brg Width = 8.0 Min Req = 1.8 Soffit: 0.00 FBC 7th Ed. 2020 Res. Max TC CSI: 0.934 BCDL: 5.0 psf H Br Width = 8.0 Min Re 9 q = 1.8 Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.752 Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.751 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/l0(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 2194 -2804 E - F 2386 -2693 Top chord: 2x4 SP #2 N; T3 2x4 SP 2400f-2.OE; C - D 2057 - 2533 F - G 2066 - 2539 D - E 2502 -2773 G - H 2184 -2797 Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Bracing Chords Tens.Comp. Chords Tens. Comp. (a) 1X4 #3SRB or better continuous lateral restraint to B - L 2448 -1855 K - J 2163 -1578 be equally spaced. Attach with (2) 8d Box or Gun L - K 2147 -1575 J - H 2440 -1822 nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. Maximum Web Forces Per Ply (Ibs) (a) or scab reinforcement may be used in lieu of CLR Webs Tens.Comp. Webs Tens. Comp. restraint. substitute (1) scab for (1) CLR and (2) scabs L - D 470 -71 K - F 626 -612 for (2) CLR'S where shown. Scab reinforcement to be D - K 739 -778 F - J 466 - 52 same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. E - K 789 -534 �y�t{{t{{t{{t411f11{ 11 w` Wind H. `���i Wind loads based on MWFRS with additional C&C •s�pO"4 °Ae,/°� member design.$°��°;E• Wind loading based on both gable and hip roof types. C3. �� •m a S f i6 0 a S m ®����eatoaufl o•P00 ��1� ' COA f# dAL �•`'` t041no ,0 03/10/2021 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. • Refer to and follow the latest edition Component Safety Information, by TPI and SBCA) for safety to these functions. Installers of BCSI (Building temporary practices prior performing shall provide bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attache,. ri id ceiling Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicabgle. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW Buildin$Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the ANR CCWAW truss in conformance with ANSI 1, or for handling, shipping,, installation bracin trusses. A this drawing and of seal on or cover pa a 675o Forum Drive listing this drawing indicates acceptance of professional en meering responsibility solely or the design shown. The suitability and use of0 is -- drawing for any structure is the responsibility of the Building -Designer per ANSVTP1 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250038 / HIPS Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1X3L89750176 T4 / FROM: RWM Qty: 1 7A5/320 ,182ED,F ,02G ,RI01 / 1828/CALIl4EB6 ELEV.D/F DrwNo: 069.21.1632.52459 Truss Label: Al2 SSB / WHK 03/10/2021 30'8" 39'8" 9' i 6X6 T2 5D5 —4E4 T3 =6X6 F ,2 6 T T b (a) W (a) W5 B T A G In T3 H 4X6(A2) = 6X6 = 6X6 = 6X6 = 4X6(A2) 39'8" 10' 9'10" 10, 10' 19'10" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.251 J 999 240 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.469 J 999 240 B 1556 /- /- /921 l720 /223 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.081 1 - - G 1556 /- /- /921 /720 /- Des Ld: 37.00 EXP: C Kzt: NA Mean Height: 15.00 ft HORZ(TL): 0.150 1 Wind reactions based on MWFRS NCBCLL: 10.00 Building Code: Creep Factor: 2.0 TCDL: 4.2 psf B Brg Width = 8.0 Min Req = 1.8 Soffit: 0.00 FBC 7th Ed. 2020 Res. Max TC CSI: 0.939 BCDL: 5.0 psf G Br Width = 8.0 Min Re 1.8 g q = Load Duration: 1.25 MWFRS Parallel Dist: hl2 to h TPI Std: 2014 Max BC CSI: 0.834 Bearings B & G are a rigid surface. Bearings B & G require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.306 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 2250 -2705 E - F 2239 -2478 C - D 2238 - 2478 F - G 2250 - 2704 Top chord: 2x4 SP #1; T2,T3 2x4 SP #2 N; D - E 2906 -3233 Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W2,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Bracing Chords Tens.Comp. Chords Tens. Comp. (a) 1X4 #3SRB or better continuous lateral restraint to B - K 2330 -1856 J - 1 3176 - 2629 be equally spaced. Attach with (2) 8d Box or Gun K - J 3174 -2647 I - G 2329 -1835 nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. Maximum Web Forces Per Ply (Ibs) (a) or scab reinforcement may be used in lieu of CLR Webs Tens.Comp. Webs Tens. Comp. restraint. substitute (1) scab for (1) CLR and (2) scabs C - K 718 -428 E - I 944 -834 for (2) CLR'S where shown. Scab reinforcement to be K - D 940 - 832 1 - F 718 -430 same size, species, grade, and 80% length of web member. Attach with Oil28x3" gun nails @ 6" oc. yi tit48ttip►//@1rtty Wind�� Wind loads based on MWFRS with additional C&C member design. ,°'��®e ✓ yr " Wind loading based on both gable and hip roof types. 4• o s o. T08 1 ° s ® r ' n � a� Ai 000A ,ON fit, f14'+��� gamutN 1 03/10/2021 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING **IMPORTANT*' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing.. Refer to and follow the latest edition Component Safety Information, by TPI SBCA) fo'r of BCSI (Building and safety practices prior to performing these functions. Installers shall provide bracing BCSI. Unless noted otherwise, top chord shall have and bottom temporary have per propery attached structural sheathing chord shall a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed BCSI sections B3, B7 or B10. per as applicable. Apply Oates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW BuildingQ Components Group Inc. shall not be responsible for any deviation from this drawing, any, failure to build the ANMCOWA- in truss conformance with ANSI/TPI--1, or for handling, shipping,, installation. and bracing of trusses. A seal on this drawin or cover pacle 675o Forum Drive listing this drawing indicates acceptance of professional engineering responsibilittyy solely -for the design shown. The suitability and use of This Suite Fos drawing for is the the Building -Designer ANS1141 1 Sec.2. any structure responsibility of per For more information see these web sites: Alpine: al ineilw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250056 / HIPS Ply: 2 Job Number: N334504 Cust: R 8975 JRef:1X3L89750176 T12 / FROM: LPM Qty: 1 7A51320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52554 Truss Label: A14G SSB / WHK 03110/2021 2 Complete Trusses Required 7' 17' 22'8" 32'8" 39'B.. 7 10, 5'8" 10' 7 =6X6 =8X8 =8X8 12 C T2 D T3 E T4 =_6X6 F Tiv) 6� o T io B G v 3� A H 4X6(A1) =8X8 =8X8 =8X8=4X6(A1) 1 39'8" �1' 10' 91101.9.10" 10, 10' 19,10" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Sid: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.295 J 999 240 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.555 J 850 240 B 3135 /- /- /- /1427 /- BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.064 1 - - G 3136 /- /- /- /1428 /- Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.121 1 Wind reactions based on MWFRS Mean Height: 10.51 ft NCBCLL: 0.00 TCDL: 4.2 psf Building Code: Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.676 G Br Width = 8.0 Min Re 1.8 g q = Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.507 Bearings B & G are rigid surface. Bearings B & G require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: No Max Web CSI: 0.760 Members not listed have forces less than 375# Loc. from endwall: NA FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 1424 - 3094 E - F 1534 - 3602 C - D 1533 - 3601 F - G 1425 - 3094 Top chord: 2x4 SP #2 N; T2,T4 2x6 SP SS; D - E 2128 -4831 T3 2x6 SP #2 N; Bot chord: 2x6 SP SS; Webs: 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Nailnote B - K 2752 -1257 J -1 4769 - 2187 Nail Schedule:0.128"x3", min. nails K - J 4768 -2187 I - G 2753 -1258 Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @12.00" o.c. Webs : 1 Row @ 4" o.c. Maximum Web Forces Per Ply (Ibs) Use equal spacing between rows and stagger nails Webs Tens.Comp. Webs Tens. Comp. in each row to avoid splitting. C - K 1287 -417 E - I 727 -1297 Loading K - D 727 -1298 1 - F 1287 -417 #1 hip supports 7-0-0 jacks with no webs.tg�ts4strnrtatru� r� Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. 1 a * 7.0ia {� 1 s $ i1. Y « ® Y e P ¢ • er+ pW�g ° dYi m ,ON A COA tar �a�a?s�rlro�s 03/10/2021 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling shipping, installing and bracing.. Refer to and follow the latest edition Component Safety of BCSI (Building Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracingp installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW Buildinc Components Group Inc. shall not. be responsible for any deviation from this drawing, any, failure to build the ANRWCOMFANV truss in conformance with ANSI 1, or for handling, shipping,, installs ion and bracin of trusses. A seal on this drawn or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibili(� solely -for the design shown. The suitability and use of this Suite Fos -Designer drawing for any structure is the responsibility of the Building per ANSI/T1 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250039 / FROM: RWM P CD 4'3 Loading Criteria (psi) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " COMN Ply: 1 Job Number: N334504 Qty: 1 7A5/320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F Truss Label: 131 5'7"4 10'8" 15'8"12 5'7"4 + 5'0"12 60"12 8' Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. =-4X4 D Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): 21'4" 5'4" 13'4" Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.047 H 999 240 VERT(CL): 0.088 H 999 240 HORZ(LL): 0.020 G - - HORZ(TL): 0.037 G Creep Factor: 2.0 Max TC CSI: 0.371 Max BC CSI: 0.611 Max Web CSI: 0.232 VIEW Ver: 20.02.00A.1020.20 g o o , P 0 "0% t +4t XA. oOsrm OatHf�p Pm9,�,�4�`` COA 03/10/2021 Cust:R8975 JRef:1X3L89750176 T20 / DrwNo: 069.21.1632.52210 SSB / WHK 03/10/2021 21'4" 5'7"4 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 864 /- /- 1529 1397 /229 F 805 /- /- /464 /361 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 F Brg Width = 8.0 Min Req = 1.5 Bearings B & F are a rigid surface. Bearings B & F require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-C 1190-1344 D-E 1113 -1152 C-D 1104 -1146 E-F 1201 -1351 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - H 1152 - 993 G - F 1161 - 955 H - G 795 - 539 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - H 471 - 284 D - G 394 - 335 H - D 383 - 322 G - E 479 - 289 —IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling,shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary. r BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly aid ceilingg Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 1310, le. AppTy plates to each face of truss and position as shown above and on the Joinf`Details, unless noted otherwise. Refer to 60A-Z for sandard plate positions. Refer to job's General Notes page for additional information. ivision of ITW BuildinlComponents Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the iformance with ANSI PI 1, or for handling, shipping,, installation and bracing of trusses. A seal on this drawln or cover pale lrawing indicates acceptance of professional engrneenng responsibility solely -for the design shown. The suitability and use of This any structure is the responsibility of the Building -Designer per ANSIFr 11 Sec.2. formation see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org ALPINEAN MCOMPANY 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 250059 / GABL Ply: 1 Job Number: N334504 Cust: R 8975 JRO:1X3L89750176 T3 / FROM: HMT Qty: 1 7A5/320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52803 Truss Label: 82GE / YK 03/10/2021 10'8" 10'8" �— 4-8" 1 2' (TYP) =4X4 F m rN 43 / Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: C Kzt: NA Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 96 plf at -1.00 to 96 plf at 22.33 BC: From 20 pit at 0.00 to 20 plf at 21.33 Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes See DWGS A16015ENC160118 & GBLLETIN0118 for gable wind bracing and other requirements. WIND LOAD CASE MODIFIED! 21'4" 21'4" 21'4" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:20(0)/10(0) Plate Type(s): 21'4" Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or *=PLF PP Deflection in loc Udefl U# Gravity Non -Gravity VERT(LL): 0.005 R 999 240 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): 0.011 R 999 240 B* 125 /- /- /39 148 /11 HORZ(LL): 0.004 L - - Wind reactions based on MWFRS HORZ(TL): 0.006 R - - B Brg Width = 256 Min Req = - Creep Factor: 2.0 Bearing B is a rigid surface. Max TC CSI: 0.323 Members not listed have forces less than 375# Max BC CSI: 0.197 Max Web CSI: 0.091 V e r: 20.02.00A.1020.20 H. 4'•�°OD0°e• o f `d Y� ,IYIA • CV • 09 4�Q'9°®OAPosa.�na®'ag COA 4(i'+�77 yQ 0 AL 3#dt9868N��� 03/10/2021 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building _ Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.. Unless noted otherwise, top chord shall have proper)y attached structural sheathing and bottom chord shall have a properly • attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10 as applicable. Apply plates to each face. of truss -and position as shown above and on the Join Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildingg Components Group Inc. shall not, be responsible for -any deviation from this drawing, any. failure to build the truss in conformance with ANSI 1, or for handling, shipping,, installation and bracingp of -trusses. A seal on this drawing or cover pa e listing this drawing indicates acceptance of professional engineering responsibilitty� solely for the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.or ALPINE AN fIW COMPANY 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 250041 / COMN Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1X3L89750176 T19 ! FROM: RWM Qty: 1 ,7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52241 Truss Label: C1 SSB / WHK 03/10/2021 T 7' 5X5 C 14' 14' 7' 7' T 7' 14' Loading Criteria (psi) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.014 E 999 240 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.025 E 999 240 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.008 E - - Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.013 E Building Code: NCBCLL: 10.00 Mean Height: 15.00 ft TCDL: 4.2 psf Creep Factor: 2.0 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.767 Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.503 Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Fac: Yes Max Web CSI: 0.119 Loc. from endwall: Any FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): IVIEW Ver: 20.02.00A.1020.20 Wind Duration: 1.60 WAVE Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types p s O (� �p�q 0. 7,08 1 ° i a °��Oam°u nr0®4�°.,��� ♦'�� 03/10/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 588 /- /- /371 /272 /158 D - 527 !- /- /305 /234 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 8.0 Min Req = 1.5 Bearings B & D are a rigid surface. Bearings B & D require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 805 -740 C - D 807 -739 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - E 598 - 542 E - D 598 - 542 **WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigqid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Efefer to ALPINE drawings 16OA-Z for standard plate positions. Refer to jobs General Notes page for additional information. Alpine, a division of ITW BuildinccLLComponents Group Inc. shall not be responsible for any deviation from this drawing, any. failure to build the nN nwco nvnNr truss in conformance with ANSI 1, or for handling, shipping,. installation, and bracing of trusses. A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibilittyv solely -for the design shown. The suitability and use of This Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANS11TP1 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com: TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or AWC: awc.org Orlando FL, 32821 SEQN: 250061 / GABL Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1X3L89750176 71 ! FROM: RWM Qty: 1 ,7A5l320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.DlF DrwNo: 069.21.1632.52631 Truss Label: C2GE / YK 03/10/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Special Loads -----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 96 plf at -1.00 to 96 plf at 15.00 BC: From 20 plf at 0.00 to 20 plf at 14.00 Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes See DWGS A16015ENC160118 & GBLLETIN0118 for gable wind bracing and other requirements. WIND LOAD CASE MODIFIED! T 7' 5' -f - 2' (TYP) =4X4 D 14' 14' 14' Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:20(0)/10(0) Plate Type(s): 14' 7' Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.007 J 999 240 VERT(CL): 0.014 J 999 240 HORZ(LL): -0.004 H - - HORZ(TL): 0.009 H Creep Factor: 2.0 Max TC CSI: 0.392 Max BC CSI: 0.242 Max Web CSI: 0.142 ♦ Maximum Reactions (Ibs), or'=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B* 129 /- A /40 /50 /12 Wind reactions based on MWFRS B Brg Width = 168 Min Req = - Bearing B is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. C - D 376 -199 D - E 377 -199 Ver: 20.02.00A.1020.20 I Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. C - J 511 - 403 H - E 511 - 403 e�a® o.70$ I s m • S� 000A • e -a �� � nar��rr•®Igp 17�t+� 03/10/2021 **WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildingq�Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the M—COWA. truss in conformance with ANSI/TPI 1, or for handling, shipping,Installation and bracinq of trusses. A seal on this drawing or cover pa a listing this drawing indicates acceptance of professional engineering responsibilittyy solely -for 6750 Forum Drive or the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite Fos For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ]CC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250043 / COMN Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1X3L89750176 T13 / FROM: LPM city: 1 ,7A5/320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.53054 Truss Label: D1 / WHK 03/10/2021 5' 5' =4X4 C 10, 5' 12 6 (`7 B D in A E 8'8" F 2X4(A1) III2X4 = 2X4(A1) 10, 1'51 5- 5' 10, 1 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.007 F 999 240 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.013 F 999 240 B 434 /- /- /286 /202 /134 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.003 F - - D 434 /- /- /286 /202 /- EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft HORZ(TL): 0.006 F Wind reactions based on MWFRS NCBCLL: 10.00 Building Code: Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.5 TCDL: 4.2 psf D Br Width = 8.0 Min Re 1.5 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.345 g q = Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.257 Bearings B & D are a rigid surface. Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Fac: Yes Max Web CSI: 0.081 Bearings B & D require a seat plate. Loc. from endwall: not in 4.50 ft FT/RT:20(0)/10(0) Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords TenS.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 522 -494 C - D 521 -494 Top chord: 2x4 SP #2 N;Bot Maximum Bot Chord Forces Per PI Ibs We chord: 2x4 3; #2 N; Chords Tens.Com Chords Tens. Coin Webs: 2x4 SP #3; P• P. Wind B - F 396 -293 F - D 396 -293 Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. �gy�trauorg�,t�ua frt�rr�,,,�r �y9P � ra® f% psi � ° w o 7,08 1 ° r i . �4 AT 0 - �r°®Jilt, V osY COA Q$/ OVA ftfiamanL lll 03/10/2021 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have brac.•inq installed per BCSI sections B3, B7 or B10, —. as applicable. Apply plates to each face o truss and position. as shown above and on the JointDetails, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of.ITW BuildinlComponents Group Inc. shall not be responsible for any deviation from this drawing, any. failure to build the ANMCCWAW truss in conformance with ANSI/) PI 1, or for handling, shipping,. installation and braciin4 of trusses., A seal on this drawn or cover pa a 675o Forum Drive listing this drawin indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.or • AWC: awc.org Orlando FL, 32821 SEQN: 250044 / COMN Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1X3La9750176 T26 / FROM: LPM Qty: 1 , A5/320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52820 Truss Label: D2 / WHK 03/10/2021 5, 5' =4X4 C 10, 5' 12 6 cM B D q Et— 88 F 1112X4 =2X4(A1)=2X4(A1) 10, 5, 5' 1 5' 10, Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria - TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.007 F 999 240 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.013 F 999 240 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.003 F - - Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.006 F Building Code: NCBCLL: 10.00 Mean Height: 15.00 ft TCDL: 4.2 psf Creep Factor: 2.0 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.345 Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.257 Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Fac: Yes Max Web CSI: 0.081 Loc. from endwall: not in 4.50 ft FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): VIEW Ver: 20.02.00A.1020.20 Wind Duration: 1.60 WAVE Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types 03/10/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 434 /- /- /286 /202 /134 D 434 /- /- /286 /202 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 8.0 Min Req = 1.5 Bearings B & D are a rigid surface. Bearings B & D require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 522 - 494 C - D 521 - 494 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - F 396 - 293 F - D 396 - 293 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, hand ling shipping, installing and bracing.. -Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an c7 SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary. — bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached riccttid ceiling Locations shown for of lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face, o truss and position as shown above and on the Join f Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing, any, failure to build the ANMCOWAW truss in conformance with ANSI 1, or for handling, shipping,. installation and bracingg of trusses. A seal on this drawing or cover page 675o Forum Drive listing this drawing indicates acceptance of professional engineering responsibilitty� solely -for the design shown. The suitabil!fy and use of This Suite Fos drawing for any structure is the responsibility of the Building -Designer per ANSVTPI 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Odando FL, 32821 SEQN: 250057 / HIPS Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1X3L89750176 T18 / FROM: LPM City: 1 7A51320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52944 Truss Label: D3G I / WHK 03/10/2021 T _o 4 3' I 7' 10, i I 3' r 4' T 3' �1 4X6 = 4X6 12 C D 6� T LO B E ALiF 8'8" H G 2X4(A1) 1112X4 1112X4 =2X4(A1) Im 3'1 "12 318118 3'1 "12 1 - 3112 + 610"4 10, 1 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.022 H 999 240 Loc R+ ! R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.044 H 999 240 B 625 /- /- /- /316 /- BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.008 C - - E 625 1- /- /- /316 /- Des Ld: 37.00 EXP: C KZt: NA HORZ(TL): 0.016 C Wind reactions based on MWFRS ei Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Building Code: Creep Factor: 2.0 B Br g Width = 8.0 Min Req = 1.5 Soffit: 0.00 BCDL: 5.0 f ps FBC 7th Ed. 2020 Res. Max TC CSI: 0.288 E Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.365 Bearings B & E are a rigid surface. Bearings B & E require a seat plate. Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Fac: Varies by Ld Case Max Web CSI: 0.059 Members not listed have forces less than 375# Loc. from endwall: Any FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 467 - 962 D - E 467 - 962 C - D 389 - 842 Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Special Loads B - H 829 - 394 G - E 829 - 394 -----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) H - G 842 -389 TC: From 56 plf at -1.00 to 56 plf at 3.00 TC: From 28 plf at 3.00 to 28 plf at 7.00 TC: From 56 plf at 7.00 to 56 plf at 11.00 BC: From 20 plf at 0.00 to 20 plf at 3.03 BC: From 10 plf at 3.03 to 10 plf at 6.97 BC: From 20 plf at 6.97 to 20 pif at 10.00 TC: 129 lb Conc. Load at 3.03, 6.97 TC: 65 lb Conc. Load at 5.00 BC: 80 lb Conc. Load at 3.03, 6.97 ytgesta9altfaattara htr;�J�or BC: 52 lb Conc. Load at 5.00 e Wind �����^ �v®,Mp+aaa••aiy6 Wind loads and reactions based on MWFRS.+ Wind loading based on both gable and hip roof types. V •° py •/;°� 0 p� • S A9 0 • o COa r&lrvasnsKes�� 03/10/2021 **WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, hand lin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigqid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply Oates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE. Alpine, a division of ITW Buildin$QComponents Group Inc. shall not. be responsible for any deviation from this drawing, any, failure to build the ANMCOWANY truss in conformance with ANSI/TPI 1, or for handling, shipping,, installation and bracin4of trusses. A seal on this drawing, or cover pa a 675o Forum Drive listing this drawing indicates acceptance of professional en sneering responsibili%�rsolely-for the design shown. The suitabili y and use of this Suite Fos Drive - drawing for any structure is the responsibility of the Building -Designer per ANSI/T 1 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250045 / VAL Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1X3L89750176 T14 / FROM: LPM Qty: 1 7A5/320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52600 Truss Label: V4 / WHK 03/10/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Valley truss connection to truss below shall be designed and furnished by others . 1'11"8 I 3-11" 1111,18 1'11 "8 12 6 = 4X4 B A4X4(D1) =4X4(D1) C 0- 10'6"3 D 3'11" `h 3'11" Snow Criteria (Pg,Pf in PSF) - Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.004 999 240 VERT(CL): 0.007 999 240 HORZ(LL): -0.001 - - HORZ(TL): 0.003 Creep Factor: 2.0 Max TC CSI: 0.070 Max BC CSI: 0.098 Max Web CSI: 0.000 Ver: 20.02.00A.1020.20 03/10/2021 •'WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS the latest edition of BCSI (Building Installers shall provide temporary bottom chord shall have a properly )er BCSI sections B3, B7 or B10 mess noted otherwise. f,efer to ♦ Maximum Reactions (Ibs), or'=PLF Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL D' 75 /- A /32 /18 /6 Wind reactions based on MWFRS D Brg Width = 47.0 Min Req = - Bearing A is a rigid surface. Members not listed have forces less than 375# Alpine, a division of ITW BuildinlgComponents Group Inc. shall not.be responsible for.any deviation from this drawing, any. failure to build the truss in conformance with ANSI 1, or for handling; shipping,, installation and bracin4 of trusses. A seal on this drawing or cover page listing this drawing indicates acceptance of professional engineering responsibilitty�r solely4or the design shown. The suitability and use of this drawing for any s9r'ucture is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. ALPINE 7COMPANY 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 250046! VAL Ply: 1 Job Number: N334504 Cust: R8975 JRef1X3L89750176 T16 / FROM: LPM Qty: 1 ,7A5/320 ,162ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52975 Truss Label: VS KD / WHK 03/10/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " 311"8 7-11" 3'11'T 3'11 "8 =4X64 12 6 N 1 =4X4(D1) A D 1112X4 7'11" Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wnd Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SIP #2 N; Webs: 2x4 SIP #3; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Valley truss connection to truss below shall be designed and furnished by others . 9'6"3 3'11"8 3'11"8 3'11"8 7-11" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (lbs), or'=PLF Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity Pf: NA Ce: NA VERT(LL): 0.007 D 999 240 Loc R+ / R- / Rh / Rw / U / RL E' 75 A A /35 /26 /8 Lu: NA Cs: NA VERT(CL): 0.014 D 999 240 Snow Duration: NA HORZ(LL): -0.003 D - - Wind reactions based on MWFRS HORZ(TL): 0.006 D E Brg Width = 95.0 Min Req = - Building Code: Creep Factor: 2.0 Bearing A is a rigid surface. FBC 7th Ed. 2020 Res. Max TC CSI: 0.266 Members not listed have forces less than 375# TPI Std: 2014 Rep Fac: Yes Max BC CSI: 0.192 Max Web CSI: 0.142 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. FT/RT:20(0)/l 0(0) B - D 478 - 315 Plate Type(s): VIEW Ver: 20.02.00A.1020.20 WAVE n._ t a • ..,rrr 'b e Q, /� fg # M ®b 0, 08 t P ipq� w 1tl9' S® AN ONA 4®$ + a tl q �4�rr•rr.arP r��,t,�`s� 03/10/2021 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an c7 SBCA) for saty practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attache. rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, �.._ as applicable. Apply plates to each face of truss and position as shown above and on the Joinf Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildincLComponents Group -Inc. shall not, be responsible for any deviation from this drawing, any failure to build the ANMCOWANV truss in conformance with ANSI 1, or for handling, shipping,, installation. and bracing of trusses. A seal on this drawing or cover paWe 6750 Forum Drive listing this drawing indicates acceptance of professional en sneering responsibility solely -for the design shown. The suitabiliffy and use of this drawing for any s9ructure is the responsibility of the Building -Designer per ANSI/TP1 1 Sec.2. Suite 305 For more information see these web sites: Alpine: alpineitw.com: TPI: tpinst.oro: SBCA: sbcindustrv.com: ICC: iccsafe.cra: AWC: awc.ora Orlando FL, 32821 SEQN: 250047 / EJAC Ply: 1 Job Number: N334504 Cust: R 8975 JRef,.1X3L89750176 T15 / FROM: HMT Qty: 8 7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52538 Truss Label: EJ7 KD / WHK 03/1012021 C 12711 12 6 O LID co M V' B A $,$„ D Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1,25 MWFRS Parallel Dist: h/2 to h Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #1; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. 7 7' Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.015 D HORZ(TL): 0.028 D Creep Factor: 2.0 Max TC CSI: 0.720 Max BC CSI: 0.507 Max Web CSI: 0.000 VIEW Ver: 20.02.00A.1020.20 , H� r4i/j �4• \aBiOp o.708 I ♦ Maximum Reactions (lbs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 331 /- /- /249 /108 /208 D 125 /- /- /73 /- /- C 174 /- /- 1128 /169 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# COAL ((( �ri ®NA 03/10/2021 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing.. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10. as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Pefer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildincLComponents Group Inc. shall not, be responsible for any deviation from this drawipg, any, failure to build the �,,,,�,CO,� W truss in conformance with ANSI 1, or for handling, shipping,, installation. and bracing of trusses. A seal on this drawing or cover pa a 675o Forum Drive listing this drawing indicates acceptance of professional engiineering responsibility solely -for the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; -TPI: t inst.or • SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250048 / EJAC Ply: 1 Job Number: N334504 Cust: R 8975 JRO:1X3L89750176 T21 I FROM: HMT Qty: 6 7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52867 Truss Label: EJ7A / WHK 03/10/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Sid: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wnd Duration: 1.60 Lumber Top chord: 2x4 SP #1; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. 7' 7' Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Sid: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): B Defl/CSI Criteria PP Deflection in loc Udell U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.016 C HORZ(TL): 0.030 C Creep Factor: 2.0 Max TC CSI: 0.738 Max BC CSI: 0.513 Max Web CSI: 0.000 0V Ver: 20.02.00A.1020.20 A� W a ,� s , ` coo >N AL �' 03/10/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL A 270 /- /- /179 /71 /186 C 126 /- /- /76 /- /- B 177 /- /- /132 /171 /- Wind reactions based on MWFRS A Brg Width = 8.0 Min Req = 1.5 C Brg Width = 1.5 Min Req = - B Brg Width = 1.5 Min Req = - Bearing A is a rigid surface. Bearing A requires a seat plate. Members not listed have forces less than 3759 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS require extreme care in fabricating, handlin shipping, installing,and bracing. Refer to and follow the latest edition of BCSI (Building nent Safety Information, by TPI and SBCA) fo'r sa shipping, practices prior to performing these functions. Installers shall provide temporary. Crakper BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly d rigid ceiling Locations shown for ermanent lateral restraint of webs shall have bracing -installed per BCSI sections B3, B7 or B10, e. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to Is 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing, any, failure to build the conformance with ANSI fI PI 1, or for handling, shipping,. installation and bracingqof trusses. A seal on this drawing, or cover pa4e 1is drawing indicates acceptance of professional enQneering responsibility solely -for the design shown. The suitability and use of This 1 for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. 10111161111111 ALPINE 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 250049 / EJAC Ply: 1 Job Number: N334504 Cusl: R 8975 JRef:1X3L89750176 T24 / FROM: LPM city: 3 7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52882 Truss Label: EJ3 / WHK 03/10/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " 4P Wind Criteria Wind Sid: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. 31 31 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): N T SO O Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): -0.001 D HORZ(TL): 0.002 D Creep Factor: 2.0 Max TC CSI: 0.248 Max BC CSI: 0.112 Max Web CSI: 0.000 VIEW Ver: 20.02.00A.1020.20 03/10/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 188 !- /- /157 f71 /100 D 52 /- /- /28 /- /- C 65 /- /- /45 /66 A Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly attached rigqid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildingComponents Group Inc. shall not be responsible for any deviation from this drawing, any, failure to build the n+"Nrconw�wN truss in conformance with ANSIITPI 1, or for handling, shipping,, installation and bracinaof trusses. A seal on this drawing or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibility solely -for the design shown. The suitabilify and use of this drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250050 / JACK Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1X3L89750176 T23 / FROM: RWM Qty: 2 ,7A5/320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52195 Truss Label: EJ2 KD / WHK 03/10/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " V Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wnd Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min, toe -nails at bottom chord. 12 2X4(A1) 21 21 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): C T& 918114 cM T 818" Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.000 D HORZ(TL): 0.001 D Creep Factor: 2.0 Max TC CSI: 0.137 Max BC CSI: 0.026 Max Web CSI: 0.000 Ver: 20.02.00A.1020.20 ,'P... a e 0.708 1 0 r 4. COAL 03/10/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 157 /- !- /140 /54 /52 D 32 /- /- /18 /- A C 34 /- /- /20 /26 A Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearings B, D. & C require a seat plate. Members not listed have forces less than 375# "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have �roperr attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for ermanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face o?truss and position as shown above and on the JoinoDetails, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not. be responsible for -any deviation from this drawing, any, failure to build the truss in conformance with ANSI Q PI 1, or for handling, shipping,, installation and bracin44 of trusses. A seal on this drawingor cover page listing this drawing indicates acceptance of professional engiineenng responsibili(�r solely -for the design shown. The suitability and use Nis drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: al ineilw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.or ALPINE AN nW COWAW 6750 Forum Drive Suite 305 Odando FL, 32821 SEQN: 2500511 JACK Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1X3L89750176 T34 1 FROM: JRH City: 4 7A5/320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52898 Truss Label: CJ5 KD / YK 03/10/2021 C 11'2"5 12 6 co T CV c'M cM B A $'8" D 2X4(A1) 1,1 4'11"4 I 411 "4 Loading Criteria (psi) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): NA Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): NA B 256 /- /- /200 /88 1152 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.005 D D 89 /- A /51/- EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft HORZ(TL): 0.010 D C 118 A A /85 /116 /- NCBCLL: 10.00 Building Code: Creep Factor: 2.0 Wind reactions based on MWFRS TCDL: 4.0 psf B Br Width = 8.0 Min Re 1.5 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.549 g q = Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Sid: 2014 Max BC CSI: 0.257 D Brg Width = 1.5 Min Req = - Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Fac: Yes Max Web CSI: 0.000 C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Loc. from endwall: not in 4.50 ft FT/RT:20(0)/10(0) Bearing B requires a seat plate. GCpi: 0.18 Plate Type(s): Members not listed have forces less than 375# Wind Duration: 1.60 WAVE IVIEW Ver: 20.02.00A.1020.20 Lumber Top chord: 2x4 SP #2 N; Sot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. �tti18P11tP81tra�rrrrr �' ry�rfi $�P "ggmesaoaaa�o°" 4�,r,�fr'i�i o.748 i ' 4 � ! s SAT 0 �. r � s •o'®��®O •IIpA. �p'tl �lt COA NNAIL ktr14"1116"401�4�a�` 03/10/2021 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r. safety practices prior to performing these functions. Installers shall provide temporary bracing per SCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attachetl rigid ceiling Locations shown for Permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicabgle. Apply plates to each face o truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildinccLLComponents-Group Inc. shall not.be responsible for any deviation from this drawing, any failure to build the Mi co~ truss m conformance with ANSI PI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawing or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of professional encLineenng responsibilitty� solely or the design shown. The suitabilify and use of this drawing for any sgructure is the responsibility of the Building -Designer per ANSIlTPI 1 Sec.2: Suite 305 For more information see these web sites: Alpine: al ineilw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250052/ JACK Ply: 1 Job Number: N334504 Cust: R8975 JRef1X3L89750176 T33 / FROM: LPM Qty: 4 7A, 320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52928 Truss Label: CJ3 / WHK 03/10/2021 n 4"3 2' 11 "4 2' 11 "4 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 185 /- A /156 /71 /99 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): -0.001 D D 50 /- /- /27 A /- Des Ld: 37.00 EXP: C KZt: NA 0.001 D - - C 63 /- /- /44 /64 /- Building Code: NCBCLL: 10.00 Mean Height: 15.00 It TCDL: TCDL: 4.2 psf Creep Factor: 2.0 Wind reactions based on MWFRS Soffit: 0.00 BCDL: 5.psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.234 B Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.105 D Brg Width = 1.5 Min Req = - Spacing: 24.0 " C&C Dist a: 3.00 ItRep Fac: Yes Max Web CSI: 0.000 C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Loc. from endwall: Any FT/RT:20(0)/10(0) Bearing B requires a seat plate. GCpi: 0.18 Plate Type(s): Members not listed have forces less than 375# Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lurnoer Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. as a .pllc drawings Alpine, a truss in c listing thi: drawing t For more �+,0"��1 �*®woos•°es" 6jW a p �0. 7►08 1 p 0 ,,,� •., S OAT® ,. It ........•°o• COAKAIONAL 1� waHa�st�1�' 03/10/2021 'WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI.an fabricating, fo'r safety practices pnor to performing these functions. Installers shall provide temporary. r BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly id ceiling Locations shown for permanent lateral restraint of webs shall haw bracin installed per BCSI sections B3, B7 or B10, e. AppTy. plates to each face, of truss and position as shown above and on t�re Join Details,- unless noted otherwise. Refer to 60A-Z for standard plate positions. Refer to job's General Notes page for additional information. ivision of ITW BuildinlgComponents Group Inc. shall not,be responsible for any deviation from this drawing, any failure to build the lformance with ANSIITPI 1, or for handling, shipping,, installation and bracing of trusses. A seal on this drawing or cover page Jrawing indicates acceptance of professional engineering responsibility solely -for the design shown. The suitability and use of this any s ructure is the responsibility of the Building -Designer per ANSI/T 11 Sec.2. formation see these web sites: Alpine: alpineilw.com: TPI: tpinst.ora: SBCA: sbcindustrv.com: ]CC: iccsafe.ora: AWC: awc.ora AL NE mmco uury 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 250053 / JACK Ply: 1 Job Number: N334504 Cust: R 8975 JRef1X3L89750176 T29 I FROM: LPM Qty: 8 ,7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52743 Truss Label: CA / YK 03/10/2021 12 6 � C 4 3 1 If 11,r4 1 M 9'2"5 M. . Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 143 /- /- /145 f76 /45 BCDL: 10.00 Risk Category: 11 Snow Duration: NA HORZ(LL): -0.000 D D 11 /-2 /- /14 /10 /- Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.000 D - - C - /-15 /- /29 /33 /- Building Code: NCBCLL: 10.00 Mean Height: 15.00 ft TCDL: 4.2 psf Creep Factor: 2.0 Wind reactions based on MWFRS Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.183 B Big Width = 8.0 Min Re 1.5 g q = Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.022 D Big Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Fac: Yes Max Web CSI: 0.000 Bearing B is a rigid surface. Loc. from endwall: Any FTlRT:20(0)/10(0) Bearing B requires a seat plate. GCpi: 0.18 Plate Type(s): Members not listed have forces less than 375# Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumoer Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. H. /,,,,,, S s 0. Z08 i e � r A a � O Y SAT 0 ° COA (�;�Iemu 1 °orris rr0 ��{'rt�y`� QIYAIL 03/10/2021 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attacheU ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections 53, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Build n,,$Components Group Inc. shall not, be responsible for any deviation from this drawing, any, failure to build the �N mvm�m�Nr truss in conformance with ANSI PI 1, or for handling, shipping,, installapon,and bracing of trusses. A seal on this drawing, or cover pa!Me 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibilit�r solely -for the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSIrrPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbc!ndust .com; ICC: iccsafe.or ; AWC: awc.org Odando FL, 32821 SEON: 250054 / HIP_ Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1X3L89750176 T22 / FROM: HMT Oty: 2 , A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EB8 ELEV.D/F DrwNo: 069.21.1632.52522 Truss Label: HJ7 �TCE / YK 03/10/2021 5'3"5 5'3"5 9'10"1 4'6"11 Jol 12'2"3 12 4.24 a 2X4 C v n M � "v B T 4L33 A 8,8„ FE 2X4(A1) =4X4 1,5„ 9'2"2 9'2"2 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA BCDL: 10.00 Risk Category: II Snow Duration: NA EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 0.00 TCDL: 4.2 psf Building Code: Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Fac: No Loc. from endwall: NA FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): Wind Duration: 1.60 WAVE Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; Loading Hipjack supports 6-11-8 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. (3) 16d common (0.162"x3.5") nails at top chord (3) 16d common (0.162"x3.5") nails at bottom chord 1 7"14 9'10'1 Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc Udefl U# Gravity Non -Gravity VERT(LL): 0.049 F 999 240 Loc R+ / R- / Rh / Rw / U / RL B 326 /- A /- /154 /- VERT(CL): 0.092 F 999 240 HORZ(LL): 0.012 C - - E 364 /- /0 /- /84 /0 HORZ(TL): 0.023 C - - D 214 /- /- /- /177 /- Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.542 B Brg Width = 10.6 Min Req = 1.5 Max BC CSI: 0.670 E Brg Width = 1.5 Min Req = - Max Web CSI: 0.261 D Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# VIEW Ver: 20.02.00A.1020.20 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. B - C 392 - 565 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B - F 534 - 356 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 391 - 587 H. ♦ CO PW OOOP e• I t e COA �t+ ikdrksev�ratiftelw 03/10/2021 **WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly attached rigid ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face. of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the truss in conformance with ANSI 1, or for handling, shipping,, installation and bracing of trusses. A seal on this drawinq or cover pa a 675o Forum Drive listing this drawing indicates acceptance of professional engmeenng responsibilit�yy solely for the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building0 esigner per ANSI/YPl 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ]CC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250055! HIP_ I Ply: 1 Job Number: N334504 Cust: R8975 JRef:1X3L89750176 T17 / FROM: LPM Qty: 2 ,7A5/320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 069.21.1632.52709 Truss Label: HJ3A �TCE / YK 03/10/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " C 12 4.24 T 1 0'2"6 ti B r- CV A C� $rpu D 4'2"3 �- 1'5" 4'2"3 Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 It Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SIP #2 N; Bot chord: 2x4 SP #2 N; Loading Hipjack supports 2-11-8 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Sid: 2014 Rep Fac: No FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.001 D HORZ(TL): 0.002 D Creep Factor: 2.0 Max TC CSI: 0.120 Max BC CSI: 0.074 Max Web CSI: 0.000 VIEW Ver: 20.02.00A.1020.20 .,a�'� lye fi. pp���ti�r. D n b � a � 7 � �� ®• y®i b.IMYP�O��,l�� �� COA �0NA; ftiael""Sniur1�+ 03/10/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 84 A /- A /45 /- D 28 A /- /7 /- A C 64 /- /- /- /48 A Wind reactions based on MWFRS B Brg Width = 10.6 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS > require extreme care in-fabricatinq handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building nent Safety Information, by TPI an in-fabricating, fo'r safety practices prior to performing these functions. Installers shall provide temporary. per BCSI. Unless noted otherwise, top chord shall have Proper)v attached structural sheathing and bottom chord shall have a properly i rigid ceiling Locations shown for permanent latefel restraint of webs shall have bracing installed per BCSI sections B3, B7 or. B10, stable. AppTy plates to each face. of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to is 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. a division of ITW-Buildinq Components Group Inc. $hall not be responsible for any deviation from this drawing, any failure to build the conformance with ANSI Q PI 1, or for handling, shipping,. installation and bracingof trusses. A seal on this drawing or cover page 1is drawing indicates acceptance of professional eng6neenng responsibility solelyorthe design shown. The suitability and use of c Is I for any structure is the responsibility of the Building Designer per ANSIITPI 1 Sec.2. ALPINE ANR CC-AW 6750 Forum Drive Suite 305 Orlando FL, 32821 Gable Stud Reinforcement Detail ASCE •7-161w 160 mph Wind Speed, 15' Mean Height, Enclosed, Exposure C, Kzt = 1,00 Or, 140 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt = 1.00 Orr 140 mph Wind Speed, 15' Mean Height, Enclosed, Exposure D, Kzt = 1.00 Fir, 1pn mnh 1✓Ir,4 c.,ee.a IRI rre u..r..r, o..,.. 1_11. r.__, --- I - ___ .. _ ..... S 2x4 Brace Gable Vertical pacing Species Grade No Braces (1) lx4 'L' Brace x (1) 2x4 'L' Brace w (2) 2x4 'L' Brace xx (1) 2x6 'L' Brace x (2) 2x6 'L' Brace x Group A Group B Group A Group B Group A Group B Group A Group B Group A Group B S P F #1 #2 -0) U #3 3' 8' 5' 9' 6' 2' 7' 8' 7' 11' 9' 1'' 9' 6' 12' 0' 12' 6' 14' 0' 14' 0' HF Stud 3' 8' 5' 9' 6' 1' 1 7' 8' 7' 11' 9' 1' 9' 6' 12' 0' 12' 6' 14' 0' 14' 0' o Standard 3' 8' 4' 11' 5' 3' 6' 7' 7' 1' 8' ill 9' 6' 10' 4' 11' 1' 14' 0' 14' 0' #1 4' 0' 6' 8' 6' 11' 7' 10' 8' 2' 9' 4' 9' 8' 12' 4' 12' 9' 14' 0' 14' 0' J ' S P #2 3' 10, 6' 7' 6' 10, 7' 9' 8' 1' 9' 3' 9' 7' 12' 2' 12, 8' 14' 0' 14' 0' #3 3' 9' 5' 3' 5' 7' 6' 11' 7' 5' 9' 2' 9' 7' 10' 11' 11' 8' 14' 0' 14, 0' ai F Stud 3' 9' 5' 3' 5' 7' 6' 11' 7' 5' 9' 2' 9' 7' 10, 11' 11' 8' 14' 0' 14' 0' Cj Standard 3' 6' 4' 7' 4' 11' 6' 2' 6' 7' 8' 4' 8' 11' 9' 8' 10' 4' 13' 1' 14' 0' U S P F #1 / #2 4' 5' 7' 6' 7' 9' 8' 10, 9' 3' 10' 7' 11' 0' 13' 11' 14' 0' 14' 0' 14' 0' #3 4' 2' 7' 1' 7' 9' 8' 9' 9' 1' 10' 5' 10, 10, 13, 9' 14' 0' 14' 0' 14' 0' U I� P Stud 4' 2' 7' V 7' 6' 8' 9' 9' 1' 10' 5' 10, 10, 13, 9' 14' 0' 14' 0' 14' 0' O I� Standard 4' 2' 6' 1' 6' 5' 8' 1' 8' 8' 10, 5' 10' 10, 12, 8' 13' 7' 14' 0' 14' 0' 1 #1 4' 7' 7' 7' 7' 11' 9' 0' 9' 4' 10' 8' 11' 1' 14' 0' 14' 0' 14' 0' 14' 0' S P #2 4' 5' 7' 6' 7' 9' 8' 10' 9' 3' 10' 7' 11' 0' 13' 11' 14' 0' 14' 0' 14' 0' #3 4' 4' 6' 5' 6' 10' 8' 6' 9' 1' 10, 11' 13' 4' 14' 0' 14' 0' 14' 0' Q1 1 D F L Stud 4' 4' 6' 5' 6' 10, 8' 6' 9' 1' 10, ill 13' 4' 14' 0' 14' 0' 14' 0' Standard 4' 2' S' B' 6' 0' 7' 6' 8' 0' 10, 10, 11' 10, 12' 7' 14' 0' 14' 0' S P F #1 / #2 4' 10' 8' 3' 8' 7' 9' 9' 10' 2' MV 12' 1' 14' 0' 14' 0' 14' 0' 14' 0' #3 4' 7' 8' 2' 8' 5' 9' 8' 10, 0' 12, 0' 14' 0' 14' 0' 14' 0' 14' 0' U LJ P Stud 4' 7' 8' 2' 8' 5' 9'8'10, 0' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' O �I Standard 4' 7' 7' 0' 7' 5' 9' 4' 10, 0' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' X #1 5' 1' 8' 5' 8' B. 9' 11' 10' 3' 11' 9' 12' 3' 14' 0' 14' 0' 14' 0' 14' 0' d S P #2 410' 8' 3' 8' 7' 9' 9' 10' 2' 11' 7' 12' 1' 14' 0' 14' 0' 14' 0' 14' 0' #3 4' 9' 7' 4' 7' 10' 9' 8' 10, 1' 11' 7' 12, 0' 14' 0' 14' 0' 1 14' 0' 14' 0' D F L Stud 4' 9' 7' 4' 7' 10' 9' 8' 10' 1' 11' 7' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' Standard 4' 7' 6' 6' 6' 11' 8' 8' 9' 3' 11' 6' 12' 0' 13' 7' 14' 0' 1 14' 0' 14' 0' About 1upper Diagonal brace option, vertical length may be doubled when diagonal 18, brace Is used. I Connect diagonal brace for 6000 at each end. Max web'L' Brace End total length Is 14'.Zones, typ, #2 or iagonal r Vertical length showningle 8, In table above. e cut n) at iend. Connect'dlagonnl nt midoolnt :of vertical AN rrW CO. 115141 Earth\ Cityl Expressway 1 \ suite% 242 \ 1 Earth\ City,l MO\ 63045 `lit 1U` Refer to chart 4l wwWARNDKiww READ AND FOLLOW ALL NOTES ON THIS DRAWBm S -IMPORTANT o FMIISH THIS DRAWM TO ALL awRAcTaRS DJCLUDM THE DISTALLERSC Trusses require extreme care In fabricating, handling, shipping, InstalUng and bracing. Ref - t Ulow the latest edition of BCSI (Building Component Safety Information, by TPI and SBClU fo g •mctices prior to performing these functions. Installers shall provide temporaryy brndng pe E ,less noted otherwise, top chord shall have properly attached structural sheatWng and bo ,ail have a properly attached rigid ceiling. Locations shown for permanent later¢: restraint I ,.It have brocing Installed per BCSI sections B3, B7 or BIO, as applicable. Apply plates to eal 'truss and position as shown above and on the Joint Detalls, unless noted otherwise. �fer to drawings 160A-Z for standard plate positions. Alpine, a division of ITV Building Components Group Inc. shall not be responsible for any devlatl Js drawing, any fallwe to bullet the truss In conformance with ANSI/TPI 1, or for handling, ship] -tallntian 8 bracing of trusses. A seal on this drawing w cover page Usti g this droving, Indicates acceptance of professloral gIr:V g responsmAty surely for the design shown The suitability and use of tNs drA.Ing r any structure Is the responsd0.lty of the BultdIng Designer per ANSLTPI I Sect. For more Information see this Job's general notes page and these web sites, ALPINE, www.alpIneitw.coml TPI, www.tpinst.orgi SBCA, www.sbclndustryargl ICC, wwwlccsafemrg 4d 1 •+° �r `� AL %ih�outttP/10/2021 Bracing Group Species and Grades, Group At Spruce Hen-FIr, ql / q2 Standard q2 Stud #3 1 Stud #3 liStanclard Dou las Fir -Larch Southern Plnewww #3 q3 Stud Stud Standard I Standard Group Bt Hem -Fir #1 & Btr #1 Dou las Fir -Larch Southern Plnexww #1 #1 #2 q2 Ix4 Braces shall be SRB (Stress -Rated Board). wwFor.Ix4 So. Pine use only Industrlal 55 or Industrlal 45 Stress -Rated Boards. Group B values may be used with these grades. Gable Truss Detail Notes: Wind Load deflection criterion Is L/240. Provide uplift connections for 75 plf over continuous bearing (5 psf TC Dead Load). Gable end supports load from 4' 0' outlookers with 2' 0' overhang, or 12' plywood overhang. Attach 'L' braces with 10d (0.128'x3.0' min) nails. )K For (1) 'L' brace, space molls at 2' o.c. In 18' end zones and 4' o.c. between zones. )K)KFor (2) 'L' braces, space nulls at 3' o.c. In 18' end zones and 6' o.c. between zones. 'L' bracing must be a minimum of 807 of web member length. Gable Vertical Plate Sizes + Refer to common truss design for peak, splice, and heel plates. Refer to the Bullding Designer for conditions not addressed by this detail. Vertical Len th No S lice Less than 4' 0' 2X3 Greater than 4'', but 3X4 TOT, LD, 60 PSF SPACING 24,0' REF ASCE7-16-GAB16015 DATE 01/26/2018 DRWG A16015ENC160118 'T' Reinforcing Member Gable Truss Gabe Detail For Let -in VPrtic-nlq Gable Truss Plate Sizes ppropriate Alpine gable detail for :e sizes for vertical studs, Engineered truss design for peak, !b, and heel plates, vertical plates overlap, use a ite that covers the total area of lapped plates to span the web. ei 2*2X4 2X8 vrovtde connections for uplift specified on the engineered truss design Attach each 'T' reinforcing member with End Driven Nallst 10d Common (0.148'x 3',min) Nalls at 4' o.c. plus (4) nails In the top and bottom chords. Toenalled Nallsi 10d Common (0.148'x3',min) Toenails at 4' o.c. plus <4) toenails In the top and bottom chords, This detail to be used with the appropriate Alpine gable detail for ASCE wind load. ASCE 7-05 Gable Detail Drawings A13015051014, A12015051014, A11015051014, A10015051014, A14015051014, A13030051014, A12030051014, A11030051014, A10030051014, A14030051014 ASCE 7-10 & ASCE 7-16 Gable Detall Drawings A11515ENC100118, A12015ENC100118, A14015ENC100118, A16015ENC100118, A18015ENC100118, A20015ENC100118, A20015END100118, A20015PED100118, A11530ENC100118, A12030ENC100118, A14030ENC100118, A16030ENC100118, A18030ENC100118, A20030ENC100118, A20030ENDI00118, A20030PED100118, S11515ENC100118, S12015ENC100118, S14015ENC100118, S16015ENC100118, S18015ENCI00118, S20015ENC100118, S20015END10011 V61�Pf6ViQ, S11530ENC100118, S12030ENC100118, S14030ENC 1 30 1001 j� S18030ENC100118, S20030ENC100118, S20030 01 •* a4r..'blo*,'�+ See appropriate Alpine gable detail for maxim eklif (Zegg ,rdgr 'T' Reinforcement Attachment Detall 'T' Reinforcing 'T' Reinforcing Member Member Toe -nail - Or - End -nail To convert from 'L' to 'T' reinforcing members, multiply 'T' Increase by length (based on appropriate Alpine gable detail). Maximum allowable 'T' reinforced gable vertical Length Is 14' from top to bottom chord. 'T' reinforcing member material must match size, specie, and grade of the 'L' reinforcing member. eb Length Increase w/ °T° Brace Example ASCE 7-10 Wind Speed = 120 mph Mean Roof Height = 30 ft, Kzt = 1.00 Gable Vertical = 24'o.c. SP #3 'T' Reinforcing Member Size = 2x4 'T' Brace Increase (From Above) = 307 = 1.30 (1) 2x4 'L' Brace Length = 8' 7' Maximum 'T' Reinforced Gable Vertical Length 1.30 x 8' 7' = 11' 2' 'T' Relnf, Mbr. Size 'T' Increase 2x4 30 2x6 20 -DWORTAMTw"WARNING!" THI DRAWING TAM wo °ALL �TRNQAC�s CLUDI G ME INST sc � S DRAVING! U. «8 I REF LET -IN VERT Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refr-f-i �DATE 01�02�2018 follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) f•practices prior to performing these functions. Installers sFwll provide temporaryy bradng pUnless noted otherwise, top chord shall have properly attached structural sheathing and bob!°fshall have a properly attached rigid ceiling, Locations shown for permanent lateral restrais'1i f:l lJ p9e DRWG GBLLETIN0118 shall have bracing Installed per HCSI sections B3, H7 or, B10, as nppUcnble. Apply plates to eaF� •.• w�t ,� of truss and position as shown above and on the Joint Details, unless noted atherdse. • • its PAe6I Refer to drawings 160A-Z for standard plate positions. ` Alpine, a division of ITV Building Components Group Inc shall not be responsible for any de Wet[\n. 4•w.this drawing, any ing of to build the truss in conformance rlth ANS[/TPI 1, or far hnndting,shipch�,� ��`�+� MAX, TOT. LD. 60 PSF AN lTW COMPANY Installation 6 bracing of trusses. page llsti g this drawing, Irdcates acceptance of professlorwl A seal m this drawing or cover 1\514\Earth\ City% Expressway engineering responsibility solely for the design shown. The suitability and use of this drawing A4pJ tY /10/2021 DUR. FAC. ANY \ \ Suite\ 242 for any structure is the responsibAlty of the Building Designer per ANSI/TPI 1 Sec2. 41 1\Earth\City.\MO\63045 For more Information see this Job's general notes page and these web sites. MAX. SPACING 24.�e ALPIND www.alpineitw.coni TPD www.tpinstorgi SBCA1 www.sbclndustry.orgi ICC, wwwJccsafeorg NAIL SPACING DETAIL MINIMUM SPACING FOR SINGLE BLOCK IS SHOWN. DOUBLE NAIL SPACINGS AND STAGGER NAILING FOR TWO BLOCKS. GREATER SPACING MAY BE REQUIRED TO AV❑ID SPLITTING, BLOCK L❑CATI❑N, SIZE, LENGTH,GRADE AND TOTAL NUMBER AND TYPE OF NAILS ARE TO BE SPECIFIED ON SEALED DESIGN REFERENCING THIS DETAIL, LOAD PERPENDICULAR TO GRAIN A - EDGE DISTANCE AND SPACING BETWEEN STAGGERED ROWS OF NAILS (6 NAIL DIAMETERS) B - SPACING OF NAILS IN A ROW (12 NAIL DIAMETERS) C - END DISTANCE (15 NAIL DIAMETERS) LOAD PARALLEL TO GRAIN A - EDGE DISTANCE (6 NAIL DIAMETERS) C - SPACING OF NAILS IN A ROW AND END DISTANCE (15 NAIL D - SPACING BETWEEN STAGGERED ROWS OF NAILS (7 1/2 NAIL IF NAIL HOLES ARE PREB❑RED, SOME SPACING MAY BE REDUCED BY THE AMOUNTS GIVEN BELOW: W SPACING MAY BE REDUCED BY 50% XW SPACING MAY BE REDUCED BY 33% I ' DIRECTION OF LOAD AND NAIL ROWS CXW A A NAIL LINE cW I14:01C W J Y U E3 pq A BX B/2 )K A J TRUSS MEMBER LOAD APPLIED PERPENDICULAR TO GRAIN C DIAMETERS) DIAMETERS) ArTD TD I A LOAD APPLIED PARALLEL c)K)K MINIMUM NAIL SPACING DISTANCES DISTANCES NAIL TYPE A B)K C)K)K D 8d BOX (0.113"X 2.50'MIN) 3/4" 1 3/8' 1 3/4' 7/8' lOd BOX (0,128'X 3,°,MIN) 7/8" 1 5/8' 2' 1' 12d BOX (0,128'X 3,25°,MIN) 7/8" 1 5/8' 2' 1' 16d BOX (0,135'X 3,5",MIN) 7/8' 1 5/8' 2 1/8' 1 1/8' 20d BOX (0.148'X 4,",MIN) 1' 1 7/8" 2 1/4" 1 1/8' 8d COMMON (0.131'X 2.5°,MIN) 7/8' 1 5/8' 2' 1' 10d COMMON (0,148'X 3,°,MIN) 1' 1 7/8" 2 1/4' 1 1/8' 12d COMMON (0,148'X 3,25",MIN) 1' 1 7/8' 2 1/4' 1 1/8' 16d COMMON (0,162'X 3,5',MIN) 1' 2' 2 1/2' 1 1/4' GUN (0,120'X 2.5',MIN) 3/4' 1 1/2' 1 7/8' 1' GUN (0,131'X 2.5',MIN) 7/8' 1 5/8' 2' 1' GUN (0.120'X 3.',MIN) 3/4' 1 1/2" 1 7/8' 1' GUN (0,131'X 3,',MIN) 7/8' 1 5/8' 2' 1' c/2)" NAIL LINE ■wVARNBIIiru REAR NO FOLLOV ALL NOTES BN TIQS DRAWINGt 2t --IW tTANT" Fl1RHISH TTOS BRAVING TO ALL CWTRACTEIRS IICLUDING THE INSTALLERS9 Trusses require extreme care N fabricating, handling, shipping, Installing and bracing. Ref follow the latest editlon of BCSI (.w.g Component Safety Informatidn, by TPI and &H'Al far sr practices prior to p,,for:ng these functions. Installers shall provide temporary bracing pe B Unless noted otherrlse, top chord shall have properly attached structural sheathing and bo i shall have a properly attached rigid celltrg. Locations shorn for pernnnent lateral restraint f shall have brnUng Installed per BCSI sections 113, B7 or IIIO, as appticnble. Apply plates to ea2a Of truss and as P' pposltlon shorn above and on the Joint Detnlls, unless noted otherrlse. Refer -to drawings 160A-Z for standard plate positions. ' Alpine, a division of ITV Building Components Group Inc shall not be responsible for any devlatl� AN ITW COMPANY this drarinp, any fMure to build the truss In conformance with ANSI/TPI 1, or for handling, shll Instnllatlon 6 bracing of trusses. A seal on this drawtrg or cover page listing this drawing, YxDcntes acceptance of 115141Earth\City\Expressway professlonnl engineering responsbllity solely for the design shorn. The suttnMUty and use of this drarhg 11 Suite%242 for any structure hi tfne responsbNty of the Building Designer per ANSI/TPI 1 Sec2 1 \ Earth1 City,\ MO\ 63045 For more Information see this Job's general notes page and these web sitesi ALPINE, wwcnlpineitw.comi TPA www.tpinst.orgi SBCAi rrwsbclndustrv.arm IC6 wwwlccsafearo 4,.,� aww we �1`►J ��/, N�fi•�•. 0/2021 REF NAIL SPACE DATE 10/01/14 DRWG CNNAILSP1014 Volley DetQLil - wASCE 7-161 180 mph, 30' Mean Height, Partially Enclosed, Exp, C, Kzt=1,00 Top Chord 2x4 SP #2N, SPF #1/#2, DF-L #2 or better, Bot Chord 2x4 SP #2N or SPF #1/#2 or better. Webs 2x4 SP #3, SPF #1/#2, DF-L #2 or better, �� Attach each valley to every supporting truss withi 535# connection or with (1) Simpson H2,5A or equivalent connector for ASCE 7-16 180 mph, 30' Mean Height, Part. Enc, Building, Exp, C, Wind TC DL=5 psf, Kzt = 1.00 Or ASCE 7-16 160 mph, 30' Mean Height, Part, Enc, Building, Exp. D, Wind TC DL=5 psf, Kzt = 1.00 Bottom chord may be square or pitched cut as shown, Valleys !short enough to be cut as solid triangular members from a single 2x6, or larger as required, shall be permitted in lieu of fabricating from separate 2x4 members, All plates shown are Alpine Wave Plates, 3X4 12 12 IMax, I- 2X4 X4 — 8-0-0 max (I 4X4 20-0-0 (++) Supporting trusses at 24' o,c, maximum spacing, Unless specified otherwise on engineer's sealed design, for vertical valley webs taller than 7-9' apply 2x4 'T' reinforcement, 807 length of web, same species and grade or better, attached with 10d box (0.128' x 3,0') nails at 6' o.c, In lieu of 'T' reinforcement, 2x4 Continuous Lateral Restraint applied at mid -length of web is permitted with diagonal bracing as shown in DRWG BRCLBANC1014, Top chord of truss beneath valley set must be braced wlthi properly attached, rated sheathing applied prior to valley truss Installation, Or Purlins at 24' o.c, or as otherwise specified on engineer's sealed design Or By valley trusses used in lieu of purlin spacing as specified on Engineer's sealed design, www Note that the purlin spacing for bracing the top chord of the truss beneath the valley is measured along the slope of the top chord, ++ Larger spans may be built as long as the vertical height does not exceed 14'-01, Valle Spacing Pitched Cut Bottom Chord Valley Square Cut Bottom Chord Valley H. ..VARNBO" READ AND Fl9 r nV ALL NDTES DN THIS IDtAVINGI 0. ■.IlPORTANTo RJMSH THIS DRAVING TD ALL CONTRACTORS MMUDING THE MSTALLERS. i Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refe�dd foliov the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA)forrf$�y s e practices prior to performing these functions. Installers shall provide temporary bra, per SL Unless noted otherwise, top chord shall have properly attached structural sheathing and bolt cho shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint o • • �7 i11 V • shop have 6rac, In per HCSI sections B3, B7 or BIO, as applicable. Apply plates to each $a iiiiij of truss and pposklon as shown above and on the Joint Details, unless noted otherwise.°•• �4 • ,`r��trf PIN I Refer to draw ngs 160A-Z for standard plate positions. `tC Alpine, n division of ITV Building Components Group Inc shall not be responsible for any deviation °°• { ••°' this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping, e•stuana• AN ITW COMPANY Installation 6 brndng of trusses. \ \ 5141 Eadh1 Cil l Expressway A seal on this drawing or cover page Usti g this drawing, Irekates acceptance of professloral �! U ONAL v P y engineering responsealty solely for the design sham The suitability and use of this drawing 44% NAL /10/2021 \ \ Suite\ 242 for any structure Is the responsibility of the BuAding Designer per ANSI/TPI I Sect. 7gaTst \ \ Earth\ City,\ MO\ 63045 For more Information see this Job's general notes page and these web sltesr ALPINE! www.alpineltw.comi TPD www.tpinst.orgi SBCAr wwcsbclndustry.orni ICO wwwJccsafe.cro 2X4 4X4 Stubbed Valley ❑Ptional Hip End Detail Joint Detail m i usses I Partial Framing : 2 ' O.C. I Plan ,TC--LL 30 30 40PSF REF VALLEY DETi TC DL 20 15 7 PSF DATE 01/26/2018 BC DL 10 10 10 PSF DRWG VAL180160118 BC LL 0 0 0 PSF TOT, LD, 60 155157PSF DUR.FAC,125/1.33I1.15 11.1' SPACING 24.0' Valley Detail - ASCE 7-16: 30' Mean Height, Enclosed, Exp, C, Kzt=1,00 Top Chord 2x4 SP #2N, SPF #1/#2, DF-L #2 or better, Bot Chord 2x4 SP #2N or SPF #1/#2 or better, Webs 2x4 SP #3, SPF #1/#2, DF-L #2 or better, �" Attach each valley to every supporting truss with: (2) 16d box (0,135' x 3,5') nails toe -nailed for ASCE 7-16, 30' Mean Height, Enclosed Building, Exp, C, Wind .TC DL=5 psf, Kzt = 1.00, Max, Wind Speed based on supporting truss material at connection location: 170 mph for SP (G = 0.55, min,), 155 Hph for DF-L (G = 0,50, min,), or 120 mph for HF & SPF (G = 0.42, min,), Maximum top chord pitch is 10/12 for supporting trusses below valley trusses. Bottom chord of valley trusses may be square or pitched cut as shown. Valleys short enough to be cut as solid triangular members from a single 2x6, or larger as required, shall lbe permitted in lieu of fabricating from separate 2x4 members, Unless specified otherwise on engineer's sealed design, for vertico,t valley webs taller than 7-9' apply 2x4 'T' reinforcement, 80% lengtih of web, same species and grade or better, attached with 10d box (0,128' x 3,0') nails at 6' o,c, In lieu of 'T' reinforcement, 2x4 Con- joous Lateral Restraint applied at mid -length of web is permitted with diafno,I bracing as shown in DRWG BRCLBANC1014, Top chord of truss beneath valley set must be braced with) properly attached, rated sheathing applied prior to valley truss Installation, Or Purlins at 24' o,c, or as otherwise specified on engineer's sealed design Or By valley trusses used in lieu of purlin spacing as specified on Engineer's sealed design, WWW Note that the purlin spacing for bracing the top chord of the truss beneath the valley is measured along the slope of the top chord, ++ Larger spans may be built as long as the vertical height does not exceed 14'-0', All plates shown are Alpine Wave Plates, 4X4 2X4 12 J.3X4 Valle 12 Max, I Spacing 2X4 X4 Pitched Cut Square Cut Stubbed Valley Optional Hi �---- 8-0-0 max Bottom Chord Bottom Chord End Detail Joint Detail Valley Valle 4X4 Toe -nailed / y s* 12 Z Cormon T-usses 12 Max, t 2 ' o, , X3 12 ll Set 1X3 6-0-0 10 Max, 1 a 4 1X3 (Max Spacing) 2X4 I? Y '� Q 1X3 SX4/SPL 1X3 SQ� 'AlIllil t4Fya�r�ltyfo7 4® ''',Common T usses 20-0-0 (++) ®a°•°°°°° Partial Framing ``•a~`� Plan '• 'f .rr at 24 o,c, Supporting trusses at 24' o,c, maximum spacing, � ,a ..vARWSH T `S AD AMWAVING FOLLAL "C TMTN=S RS TMSDICL WAVDING TH a• LL 30 30 40PSF REF VALLEY DETAIL r.IlRQ2TANT>v FlittlISN THIS DRAVING TO ALL CQITRACTI?itS INCLl1DITXi THE INSTALLER Trusses require extreme care 4i Fabrlcating, handling, shipping, Information, b and bancing. , rFr a TC DL 20 15 7 PSF DATE 01/26/ 0018 follow the latest edition of BCSI (BuRdIng Component Safety Information, by TPI and SBCA) e practices prior to performing these functions. Installers shall provide temporary bracing BCSL Unless noted otherwise, top chord shall have properly attached structural sheathing and b on ch'-d $ A'� BC DL 10 10 10 PSF DRWG VALTN160118 shall have a properly attached rigid ceiling. Locations shown for permanent lateral restrain of bs t`1 • �; shall have bracing Installed per BCSI sections H3, B7 or B10, as appUcable. Apply plates to e e ! `, of truss and position as shown above and on the Joint Detalls, unless noted otherwise. � • L__44'`++("✓ BC LL 0 0 0 PSF Refer to drawings 16CA-Z for standard plate positions, 6 A P' "' Alpine, a division of ITV Building Components Group Inc shalt not be responsible for any deviatl ®.� .•'�' �� TOT. LD, 60 55 57PSF this drawing, any failure to build the truss In conFarnnnce with ANSIRPI 1, or for hnndUng, shippi •°°(�•oa• tattlan 6 bracing of trusses. AN fTW COMPANY Ins e page llstImg this drawing, Indicates acceptance of professional A seat on this drawing or cover S/ 11514\ Earth\ City\ Expressway engineering responsibility solely for the design shorn. The suitnblUty and use of this drawing 4f�j � �10/2(]z 1 responsibility of the Building Designer per ANSUTPI i sec2 DUR,FAC.1.25/1.33 1.15 I.15 \1Sui1e1242 Vol any str7,ctrre Is the re 1\Earth\City,\MO\63045 For more Informatlon see this Job's general notes page and these web sites,SPACING 24,0' ALPINE. rrw.alpineitw.comi TPI, ww►,tpinst.orgi SBCAr w—shclndustry.orgi ICC, wwwJccs4fe.org 1 " I 1 e w VALLEY FRAMING & BRACING DETAIL R eC h/2 01 Lumber Size and Grade Minumum Requirements GENERAL NOTES Purlins required T-O" O.C. in absence of plywood sheathing. Trusses without sheathing applied must be evaluated accordingly. Purlins should overlap sheathing one truss spacing minimum. In cases that this is Impractical, overlap sheathing a minimum of 6", and nail upwards through sheathing into purlin with a minimum of 8-8d (0.131"x2.5") common wire nails. Effects of not providing sheathing below a valley set must be evaluated by the building designer. This drawing applies to valleys with the following conditions: Spans (distance between heels) 40'-0" or less -Maximum valley height: 14'-0" -Maximum mean roof height: 30 feet -ASCE 7-05, 140 mph, Enclosed, Cat 11, Exp B, 1=1.0, Kzt=1.0 -Or A Maximum of ASCE 7-10,180 mph, Enclosed, Exp D, Kzt=1.0 TRUSS TRUSS UNDER VALLEY FRAMING VALLEY RAFTER OR RIDGE ® "CRIPPLE ripples 4'-011 for 30 psf (TL) and 20 psf (TD) Max. ce the crippes for each row starting from the valleys or sleepers working Inward to the ridge board so that cripple locations are gored between rows. (TYp) innection Requirement Notes 2x6 rafters to ridge 416d toe -nails Cripple to ridge 416d toe -nails Cripple to rafter 416d toe -nails (••) 816d face -nails Rafter to sleeper or blocking 516d toe -nails Rafter to two 2x6 sleepers 416d toe -nails Sleeper to truss 416d toe -nails Two 2x6 sleepers to truss 316d toe -nails each sleeper & truss Ridge board to roof block 416d toe -nails Ridge board to truss 416d toe -nails Purlin to (Typ) 316d toe -nails Truss to blocking 416d toe -nails Truss to cripple 416d toe -nails Truss to cripple 416d toe -nails Cripple to purlin 316d toe -nails %­, n`­,r ""- AR` "'c"I 13. Collar beam to rafter 416d toe -nails CRIPPLE, BRACING, & BLOCKING NOTES NOTE: 16d(0.162"x3.5^)COMMON NAILS -2x4 continuous lateral restraint (CLR) min. is required for cripples 5'4" to 10'-0" Iony nailed w/ 2 -10d (0.148"x3") nails. Or Wx r' or scab reinforcement nailed to flat edge of cripple with 1 Od 50.128"x3.0") nails at 6" o.c. "T' or scab must be 90% of cripple length. Cripples over 10'-0' long requre two CLR's or both faces w/ "T' or scab. Use stress graded lumber & box or common nails. Narrow edge of cripple can face ridge or rafter, as long as the proper number of nails are installed into ridge board -Install blocking under rafter if sleepers are not used. -Install blocking under cripples If cripples fall between lower truss top chords and lateral bracing is not used. -Apply all nailing in accordance to current NDS requiremen rite Nails are common wire nails unless noted otherwise. N, S'16.*,DGEMSF•- ; aVAF4aNGaw READ Nol FtL!" ALL NOTES ON TIaS MAVDiri w aWMTANTo FURNISH T}OS DRAVD6 M ALL COKMACi1RS Dr„ CIM TIE INSTALLERS. Trusses req,Me extreme care h fnbrtcatkg, hanfakg, sNppkg, Installkg and bratlrg. •Refer town follow the Intact edition of SCSI MA kV Ccnponcnt Safety Information, by TPI and SBCA) for mist practices prior to perfomk,p these furctlons. Installers shall provide tenporarY bracing per Bt Unless rood otherelse, top chord shall have property att..h d struct—t sheathing and bottonih shall have A ProPerlY attached rigid celkg. Locations shorn far perrarent lateral restra %t of G* a jj �T� Tt� shall havebracIngposition ionkisidtled per SCSI sections B3, 17 or Big, as npplkohle. Applydot plates to each r �� l�j�\`V'll Deft is � pw 16D as foown above pt on the Jdnt Detolls, unless rated otherwise. V wigs 160A-z for stoMora plate positions. Npke, a &Aslon of rTV Baking Components Group Inc. shoe rot be msponsble for my deviation f AN rTW COMiANY this alwwklg, any falure to build the teas kr conforname with ANSI/TPI 1, or for huxillro, 311pping, kwullailon 6 brocinp of trusses. A sent an this drawkg or cover page Sstkg this drawh g. a sam bi acceptance of proresshvW � soWy for the design shown The suitability and use of this dmw6V fernF.er+c 13369 LaWM.I Dro ar any sb�c Is respar."tty, of tha AArfg Desior per Att,SI/iPI 1 Sece. Eadh City, MO 63045 For rare klfomaton see this Job's general notes page end these web sites ALPM wwe4lpkeltwcoru TPL wwe.tpintory SWAj wee.sbdrdustryagl tCP mhaafeoro i STATE OF .7/'� i - sy N Al ,?o I C LL 20 30 40 54 IC DL 10 20 7 7 PC DL 0 0 0 0 BC LL 0 0 0 C TOT. LD.30 50 47 61 DUR. FAC. 1.25/1.15 SPACING SEE ABOVE REF VALLEY FRAMING DATE 10/01/14 DRWG VACNV1801015