HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTS 1/10/2021 Florida Building Code Online
FLOPIOA OVARTMENT OF Li iYl ait
ProfessionalBusiness & Regulation
r
BCIS Home I Log In I User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search
bpr
Product Approval��" USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
OFFICE OF THE FL# FL12328-R9
SECRETARY
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer TAMKO Building Products LLC
Address/Phone/Email PO Box 97
Galena, KS 66739
(417) 624-6644 Ext2305
kerri_eden@tamko.com
Authorized Signature Kerri Eden
kerri_eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext2305
kerri_eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/18/2021
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL12328 R9 COI 2020 01 COI NIEMINEN.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D6380 2013
Equivalence of Product Standards
Certified By
Sections from the Code
www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtF2AezuarjgOlAramDGm5elxgFDzaRb4t427TWXal7Bg%3d%3d 1/2
1/10/2021 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 09/29/2020
Date Validated 10/04/2020
Date Pending FBC Approval 10/12/2020
Date Approved 12/15/2020
Summary of Products
FL# Model,Number or Description
Name
12328.1 TAMKO Roof Roof underlayments for use in FBC HVHZ jurisdictions.
Underlayments(HVHZ)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R9 II 2020 09 29 FINAL ER TAMKO UNDERLAYMENTS HVHZ FL12328-
Approved for use outside HVHZ: No R9.pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See ER Section 5 for Limits of Evaluation Reports
Use. FL12328 R9 AE 2020 09 29 FINAL ER TAMKO UNDERLAYMENTS HVHZ FL12328-
R9.pdf
Created by Independent Third Party: Yes
12328.2 TAMKO Roof Roof underlayments for use in FBC non-HVHZ jurisdictions.
Underlayments(NON-
HVHZ)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL12328 R9 II 2020 09 29 FINAL ER TAMKO UNDERLAYMENTS NON-
Approved for use outside HVHZ: Yes HVHZ FL12328-R9.pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See ER Section 5 for Limits of Evaluation Reports
Use. FL12328 R9 AE 2020 09 29 FINAL ER TAMKO UNDERLAYMENTS NON-
HVHZ FL12328-R9.pclf
Created by Independent Third Party: Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
0VL1 ®
www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtF2AezuarjgOlAramDGm5elxgFDzaRb4t427TWXal7Bg%3d%3d 2/2
NEMO I etc.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford,CT 06478
04 (203) 262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION O.
TAMKO Building Products, LLC Evaluation Report 3m-TAM-20-FBCER.B-RO
PO Box 97 FL12328-119(HVHZ)
Galena, KS 66739 Date of Issuance: 09/29/2020
(417)624-6644
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 7' Edition(2020) Florida Building Code, High Velocity Hurricane Zone sections noted herein.
DESCRIPTION: TAMKO Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by:
�ciru!rrr.
W.
Robert J.M. Nieminen P.E. T• '� 'Y
,'fi. r,--`• The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 !r;°^'r� ';'s''r�^" Nieminen,P.E.on 09/29/2020. This does not serve as an
''a'% electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019,NEMO ETC,LLC
ONEMOletc.
ROOFING COMPONENT EVALUATION
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: TAMKO Roof Underlayments, as produced by TAMKO Building Products LLC, have
demonstrated compliance with the following sections of the 7t"Edition(2020)Florida Building Code,High Velocity
Hurricane Zone through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1518.4,TAS 110,RAS 115,RAS Material standard ASTM D226 2009
118,RAS 119,RAS 120,RAS 130
TAS 110 Material standard ASTM D1970 2015
TAS 110,RAS 118,RAS 119,RAS Material standard ASTM D6380 2013
120
Entity Examination Reference Date
PRI(TST5878) ASTM D1970 TAP-388-02-01 10/04/2017
PRI(TST5878) ASTM D226,Type ll TAP-420-02-01 04/19/2018
PRI(TST5878) ASTM D1970 TAP-447-02-01 10/19/2018
PRI(TST5878) ASTM D6380 847T0009 12/21/2019
PRI(TST5878) ASTM D6380 847T00010 12/21/2019
PRI(TST5878) ASTM D226,Type II TAP-351-02-01 04/25/2016
PRI(TST5878) ASTM D226,Type II TAP-351-02-02 05/04/2016
UL LLC(TST9628) ASTM D226,Type II 13CA12269 03/14/2014
UL LLC(QUA9625) Quality Assurance Service Confirmation 10/20/2020
UL LLC(QUA9625) Quality Assurance Florida BCIS Current
PRODUCTDESCRIPTION:
Product Material Standard Plant(s) Description
4.1 No.30 UL ASTM D226,Type II Joplin,MO Asphalt-saturated organic felt
Green Cove Springs,FL
4.2 No.30 ASTM ASTM D226,Type II Phillipsburg,KS Asphalt-saturated organic felt
4.3 TAM-FELT® ASTM D226,Type II Green Cove Springs,FL Asphalt-saturated organic felt
4.4 Moisture Guard® ASTM D1970 Joplin,MO Self-adhering,fiberglass reinforced SBS
modified bitumen roof underlayment with a
mineral top surface.
4.5 TW Underlayment ASTM D19701 Columbus,KS Self-adhering,SBS modified bitumen roof
underlayment with a polymer-film top
surface.
4.6 TW Seam Tape ASTM D1970 Columbus,KS Self-adhering,SBS modified bitumen roof
underlayment with a polymer-film top
surface.
Agreement between purchaser and seller,as set forth in Section 4.3,Note 1 of ASTM D1970-15,should be established as to slip resistance of TW
Underlayment.
NEMO ETC,LLC Evaluation Report 3m-TAM-20-FBCER.B-R0
Certificate of Authorization#32455 7T"EDITION(2020)FBC HVHZ EVALUATION FL12328-R9
TAMKO Roof Underlayments Revision 0:09/29/2020
Page 2 of 5
ONEMOletc.
Product Material Standard Plant(s) Description
4.7 ASTM Slate Surfaced Roll ASTM D6380, Green Cove Springs,FL Asphalt-saturated organic mat,coated on
Roofing Class M,Type II both sides with asphalt and surfaced with
granules.
4.8 ASTM Tile Underlayment ASTM D6380, Green Cove Springs,FL Asphalt-saturated organic felt,coated on
Class M,Type II both sides with asphalt and surfaced with
granules.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way,the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC High Velocity Hurricane Zone jurisdictions only (i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC HVHZ 1516 for requirements
and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 TAMKO Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Asphalt Clay and Concrete Tile Metal Wood
Shingles (ra5110(511),
g RA5118,119&120] (RA5133) Slate (RAS 130)
Underlayment (rA5 [TA5110(511)]
110(510), Mechanical Adhesive-
RA5115] Attach Set Panels Shingles Shingles Shakes
Yes Yes
No.30 UL Yes (Base Sheet in (Base Sheet in Yes Yes Yes Yes Yes
2-ply system) 2-ply system)
Yes Yes
No.30 ASTM Yes (Base Sheet in (Base Sheet in Yes Yes Yes Yes Yes
2-ply system) 2-ply system)
TAM-FELT® Yes No No Yes Yes Yes Yes Yes
Yes Yes Yes Yes
Moisture Guard' (Cap Sheet in No No No No (Cap Sheet in 2- (Cap Sheet in 2- (Cap Sheet in 2-
2-ply system) ply system) ply system) ply system)
Yes Yes Yes Yes Yes Yes
TW Underlayment (Cap Sheet in No No (Cap Sheet in (Cap Sheet in (Cap Sheet in 2- (Cap Sheet in 2- (Cap Sheet in 2-
2-ply system) 2-ply system) 2-ply system) ply system) ply system) ply system)
TW Seam Tape Yes Yes Yes Yes Yes Yes Yes Yes
(joint strips) (joint strips) ijoint strips) (joint strips) (joint strips) (joint strips) (joint strips) (joint strips)
ASTM Slate Surfaced Roll Yes Yes
Roofing (Valley Liner) (Cap Sheet in 2- No No No No No No
ply system)
Yes Yes
ASTM Tile Underlayment (Valley Liner) (Cap Sheet in 2- No No No No No No
ply system)
NEMO ETC,LLC Evaluation Report 3m-TAM-20-FBCER.B-R0
Certificate of Authorization#32455 7T"EDITION(2020)FBC HVHZ EVALUATION F1.12328-119
TAMKO Roof Underlayments Revision 0:09/29/2020
Page 3 of 5
ONEMOJetc.
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED LINDERLAYMENTS
Underlayment Application Primer Substrates
Moisture Guard'or TW Underlayment self-adhering (Optional)ASTM D41 plywood
None No.30 UL,No.30 ASTM or TAM-FELT®
TW Seam Tape self-adhering (Optional)ASTM D41 plywood
ASTM Slate Surfaced Roll Roofing or hot asphalt None No.30 UL,No.30 ASTM or TAM-FELT"
ASTM Tile Underlayment
5.8 Attachment Limitations:
See Section 6.3
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment Prepared Roof Cover Maximum Exposure(days)*
Installation Type
No.30 UL,No.30 ASTM,TAM-FELT°
Moisture Guard®,TW Underlayment Any 30
ASTM Slate Surfaced Roll Roofing,ASTM Tile Underlayment
*Maximum exposure shall not exceed the manufacturer's recommendations,which may be less than 30 days.
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies, the tile
shall be staged atop battens during loading of the roof tiles.
6. INSTALLATION:
6.1 TAMKO Roof Underlayments shall be installed in accordance with TAMKO Building Products LLC installation
instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Approved Assemblies:
6.3.1 Deck: Min. 19/32-inch plywood or wood plank
Secondary Water (Optional)TW Seam Tape self-adhered over joints of the plywood roof deck prior to installation
Barrier: of subsequent layer(s). Do not overlap end-joints or T-joints. All end-joints and T-joints shall
be butted firmly side by side,flush with each other but not overlapped.
Underlayment: No.30 UL, No.30 ASTM or TAM-FELT'with min.4-inch side laps and min.6-inch end laps.
Fastening: FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5),6"o.c.at the laps and 12"o.c.at two
(2)equally spaced,staggered center rows.
Surfacing: FBC HVHZ Approved prepared roof assembly, per Table 1.
NEMO ETC,LLC Evaluation Report 3m-TAM-20-FBCER.B-RO
Certificate of Authorization#32455 7T"EDITION(2020)FBC HVHZ EVALUATION FL12328-R9
TAMKO Roof Underlayments Revision 0:09/29/2020
Page 4 of S
ONEMOletc.
6.3.2 Deck: Min. 19/32-inch plywood or wood plank
Secondary Water (Optional)TW Seam Tape self-adhered over joints of the plywood roof deck prior to installation
Barrier: of subsequent layer(s). Do not overlap end-joints or T-joints. All end-joints and T-joints shall
be butted firmly side by side,flush with each other but not overlapped.
Base Sheet: No.30 UL, No.30 ASTM or TAM-FELT'with min.4-inch side laps and min.6-inch end laps.
Fastening: FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5),6"o.c.at the laps and 12"o.c.at two
(2)equally spaced,staggered center rows.
Cap Ply: Moisture Guard'or TW Underlayment,self-adhering
Surfacing: FBC HVHZ Approved prepared roof assembly, per Table 1.
6.3.3 Deck: Min. 19/32-inch plywood or wood plank
Secondary Water (Optional)TW Seam Tape self-adhered over joints of the plywood roof deck prior to installation
Barrier: of subsequent layer(s). Do not overlap end-joints or T-joints. All end-joints and T-joints shall
be butted firmly side by side,flush with each other but not overlapped.
Base Sheet: No.30 UL or No.30 ASTM with min.4-inch side laps and min.6-inch end laps.
Fastening: FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5),6"o.c.at the laps and 12"o.c.at two
(2)equally spaced,staggered center rows.
Cap Ply: ASTM Slate Surfaced Roll Roofing or ASTM Tile Underlayment with min. 3-inch side laps and
min.6-inch end laps.
Attachment: Adhered in full mopping of ASTM D312,Type IV hot asphalt at 25 Ib/sq + 15%, and backnailed
at the side laps with FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5)spaced max. 12"
o.c. The headlap of the subsequent layer is to cover the backnailed row.
Surfacing: FBC HVHZ Approved tile roof assembly, per Table 1.
REQUIREMENTS:7. BUILDING PERMIT
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QUALITY9.
UL LLC—QUA9625; (414) 248-6409; Karen.buchmann@ul.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 3m-TAM-20413CER.13-110
Certificate of Authorization#32455 7T"EDITION(2020)FBC HVHZ EVALUATION FL12328-R9
TAMKO Roof Underlayments Revision 0:09/29/2020
Page 5 of 5