HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING METAL ROOF' iYl 0`2 -
Professional ' . � d
r
BCIS Home I Log In I User Registration Hot Topics I Submit Surcharge I Stats&Facts Publications Contact Us BCIS Site Map Links Search
bpr
Product Approval��" USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
OFFICE OF THE FL# FL7271-R5
SFCRETARY
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer UNION CORRUGATING COMPANY
Address/Phone/Email 701 S. KING ST.
FAYETTEVILLE, NC 28301
(910)813-2432
rblake@unioncorrugating.com
Authorized Signature Randy Blake
rblake@unioncorrugating.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Bala Sockalingam
Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 09/07/2027
Validated By Yoosef Lavi, P.E.
Validation Checklist- Hardcopy Received
Certificate of Independence FL7271 R5 COI CertificateIndependence.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM E1592 2005
FM 4470 2016
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/10/2020
Date Validated 10/12/2020
Date Pending FBC Approval 10/22/2020
Date Approved 12/15/2020
Summary of Products
FL# Model,Number or Name Description
7271.1 2-1/2"Corrugated Panel Min 26 ga., 24"wide through fastened panel with coverage
width of 21-1/4"
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7271 R5 II Eva I uation ReportC2400 1.pdf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-129.25 Evaluation Reports
Other: Uplift load of 129.25 psf @ fastener spacing of 24"o.c. FL7271 R5 AE Eva I uation ReportC2400 1.pdf
over 19/32"thick plywood Created by Independent Third Party: Yes
7271.2 5V Min 26 ga., 24"wide through fastened panel over 19/32"thick
plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7271 R5 II Eva I uation ReportC2400 2.pdf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/-120.9 Evaluation Reports
Other: Uplift load of 120.9 psf @ fastener spacing of 24"o.c. FL7271 R5 AE Eva I uation ReportC2400 2.pdf
for Fastener Pattern 1. Uplift load of 85.8 psf @ fastener Created by Independent Third Party: Yes
spacing of 24"o.c. and 113.1 psf @ fastener spacing of 12"o.c.
for Fastener Pattern 2.
7271.3 5V Min 29 ga.,24"wide through fastened panel over 15/32"thick
plywood or 7/16"thick OSB
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7271 R5 II Eva I uation ReportC2400 3.pdf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-52.5 Evaluation Reports
Other: Uplift load of 52.5 psf @ fastener spacing of 12"o.c. FL7271 R5 AE Eva I uation ReportC2400 3.pdf
Created by Independent Third Party: Yes
7271.4 5V Min 26 ga., 24"wide through fastened panel over 15/32"or
19/32"thick plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7271 R5 II Eva I uation ReportC2400 4.pdf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-150 Evaluation Reports
Other: Uplift load of 150 psf in 19/32"thick plywood for FL7271 R5 AE Eva I uation ReportC2400 4.pdf
Fastener Pattern 2 Created by Independent Third Party: Yes
7271.5 MasterRib Min 29 ga., 36"wide through fastened panel over nom. 1"x 4"
furring and 15/32"thick plywood or 7/16"thick OSB
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7271 R5 II Eva I uation ReportC2400 5.pdf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-114 Evaluation Reports
Other: Uplift load of 71 psf for Fastener Pattern 1 &114 psf FL7271 R5 AE Eva I uation ReportC2400 5.pdf
for Fastener Pattern 2 Created by Independent Third Party: Yes
7271.6 MasterRib Min 29 ga., 36"wide through fastened panel over 15/32"thick
plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7271 R5 II Eva I uation ReportC2400 6.pdf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-113.1 Evaluation Reports
Other: Uplift load of 56.0 psf @ fastener spacing of 24"o.c. & FL7271 R5 AE Eva I uation ReportC2400 6.pdf
113.1 psf @ fastener spacing of 12"o.c. Created by Independent Third Party: Yes
7271.7 MasterRib Min 26 ga., 36"wide through fastened panel over 19/32"thick
plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7271 R5 II Eva I uation ReportC2400 7.pdf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-114.3 Evaluation Reports
Other: Uplift load of 61.8 psf @ fastener spacing of 30"o.c. FL7271 R5 AE Eva I uation ReportC2400 7.pdf
and 114.3 psf @ fastener spacing of 24"o.c. Created by Independent Third Party: Yes
7271.8 ML200 Min 24 ga., max 16"wide standing seam metal panel with
double lock seam over metal deck.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7271 R5 II Eva I uation ReportC2400 8.pdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-116.0 Evaluation Reports
Other: Uplift load of 71.0 psf @ clip spacing of 36"o.c. and FL7271 R5 AE Eva I uation ReportC2400 8.pdf
116.0 psf @ clip spacing of 12"D.C. Created by Independent Third Party: Yes
7271.9 SL175 Min 24 ga., max 16"wide snap-lock standing seam metal panel
over metal deck.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7271 R5 II Eva I uation ReportC2400 9.pdf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-86.0 Evaluation Reports
Other: Uplift load of 63.5 psf @ clip spacing of 36"o.c. and FL7271 R5 AE Eva I uation ReportC2400 9.pdf
86.0 psf @ clip spacing of 12"o.c. Created by Independent Third Party: Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy atatement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® a ®
Credit Card
Safe
EVALUATION REPORT OF
UNION CORRUGATING COMPANY
`26 GA. MASTERRIB PANEL'
FLORIDA BUILDING CODE 7TH EDITION (2020)
FLORIDA PRODUCT APPROVAL
FL 7271.7-R5
ROOFING
METAL ROOFING
Prepared For:
Union Corrugating Company
701 S. King St.
Fayetteville,NC 28301
Telephone: (910) 483-0479
Fax: (910) 483-1091
Prepared By:
Bala Sockalingam, Ph.D.,P.E.
Florida Professional Engineer#62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (2 Pages including cover) �, a 4 a e e a s0000
Installation Details (1 Page) •,���`°gGCKA���V�`"�F�
�. 62240
m to • � . �o
,o o F
-0'• STATE 44.1 •-
Report No. C2400-7 O,r' ,c( o R\Q?••Q���°,'
Date: 10.9.2020 6��F ' .......17 `�r� .�
r
to
FL 7271.7-R5
C2400-7
10.9.2020
Page 2 of 2
Manufacturer: Union Corrugating Company
Product Name: MasterRib Panel
Panel Description: 36" wide coverage with 3/4" high ribs at 9" o.c.
Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755). Corrosion resistant as per FBC 2020 Section 1507.4.3.
Deck Description: Min. 19/32" thick APA rated plywood or min. 3/4" thick wood plank
(min SG of 0.42) for new and existing constructions. Designed by
others and installed as per FBC 2020.
Underlayment: Minimum underlayment as per FBC 2020 Section 1507.4.5.1
Slope: 1/2:12 or greater in accordance with FBC 2020 Section 1507.4.2
Design Uplift Pressure: 61.8 psf at fastener spacing of 30" o.c.
(Factor of Safety=2) 114.3 psf at fastener spacing of 24" o.c.
Panel Attachment: #9-15 or #10-14 x 1.5" long wood screw with washer. Fasteners are
corrosion resistant as per FBC 2020 Section 1507.4.4.
At panel ends 5.5"-3.5"-5.5" o.c. across panel width
At interior 9" o.c. across panel width
Sidelap Attachment: 1/4"-14 x 7/8" long SDS with washer at max 30" o.c. Fasteners are
corrosion resistant as per FBC 2020 Section 1507.4.4.
Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2020 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2020 Section 1609 or ASCE 7-16 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Refer to current NOA for use of this product in High
Velocity Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2020 Section 1505 and current
approved roofing materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
Supporting Documents: TAS 125-03 Test Reports
Hurricane Test Laboratory
Report No. 0293-0611-05, Reporting Date 8/31/05
DRAWN BY: CHECKED BY:
B5.
PLOT: DAIS:
3/19/t5
9^ (TYp) PANEL FASTENER PANEL OVERLAP
ROOF PANEL SEE DETAIL SPACING PER ALLOWABLE
� ��THIS SHEET WIND LOAD TABLE
n n u
II \ I II
UNDERLAYMENT SHALL BE INSTALLED DECK ATTACHMENT AND 1/4" X 7/8" SDS
AS PER MANUFACTURER'S INSTALLATION SUPPORTS MUST BE SPACING PER ALLOWABLE
GUIDELINES DESIGNED AND INSTALLED WIND LOAD TABLE
BY OTHERS
RAFTER/JOIST/TRUSS
AT MAX. 24" O.C.
� wo
TYPICAL PANEL INSTALLATION X—SECTION z ucoo_
Q co 0
C� oz
z LJ
ALLOWABLE UPLIFT PRESSURE o YJ Do
OVERLAP PANEL PRESSURE Z ��a
FASTENERS FASTENERS (PSF) O ow
SPACING SPACING z I,a
ALONG RIB ALONG RIB
30" 30" 61.8
24" 24" 114.3
J ll
w a
1/2" a
1/4" X 7/8" SIDS
MAX 30" O.C. #9-15 OR #10-14 X 1.5" LONG m a
WOOD SCREW WITH WASHER lIx
O MAX. 30" O.C. uj
? -
MIN 26 GA. PANEL GENERAL NOTES: g
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC). _ <0
2. ROOF PANELS SHALL BE MINIMUM 26 GA. EFFECTIVE COVERING WIDTH OF
PANEL - 36". 3 �g
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS o�
SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT.
THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN
WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
UNDERLAYMENT BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
PLYWOOD 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
19/32" THICK (MIN.) REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
DETAIL 1
DRAWING N0. REV.
C2400-7
SHEET NO.
OF ,