HomeMy WebLinkAboutcompaction testUES Project No:
Workorder No:
Report Date:
3310.2100094.0000
232991-1
05/11/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:United Teleports UES Technician:Amber Evans
19000 NE 5th Avenue
Miami, FL 33179
Date Tested:05/04/2021
Project:CMT United Teleports Satellite Antenna
10161 Range Line Road,Port Saint Lucie, County, FL 34987
Type of Test:
Area Tested: Easternmost Antenna Pad Field:ASTM D-6938 Nuclear Gauge Method
Material:Native Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Final Grade
The tests below meet the 98% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 SW side of pad 0-1 ft 112.2 11.1 110.3 10.5 98 Pass
2 NE side of pad 0-1 ft 112.2 11.1 111.6 9.3 99 Pass
3 Center of pad 0-1 ft 112.2 11.1 109.9 11.0 98 Pass
Remarks:Permit # 21020139
Reviewed By
GFA International, Inc
FBPE Registry No.4930
John Kent
Senior Project Engineer
STATE OF FLORIDA
Professional Engineer No. 63218
This item has been digitally signed and sealed by John Kent on the
date adjacent to the seal. Printed copies of this document are not
considered signed and sealed and the signature must be verified on
any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1