HomeMy WebLinkAboutUnited Teleports 231144-1 DT-dsUES Project No:
Workorder No:
Report Date:
3310.2100094.0000
231144-1
04/20/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:United Teleports UES Technician:Amber Evans
19000 NE 5th Avenue
Miami, FL 33179
Date Tested:04/15/2021
Project: United Teleports Satellite Antenna
10161 Range Line Road, Port Saint Lucie, St. Lucie County, FL 34987
Type of Test:
Area Tested:Front Most Elevated Antenna Pad Field:ASTM D-6938 Nuclear Gauge Method
Material:Native Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Native
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 SE side of pad 0-1 ft 112.2 11.1 108.4 10.2 97 Pass
2 NW side of pad 0-1 ft 112.2 11.1 107.5 9.7 96 Pass
3 Center of pad 0-1 ft 112.2 11.1 109.0 11.0 97 Pass
Remarks:Permit: 21020139
Reviewed By
GFA International, Inc
FBPE Registry No.4930
Thomas Dominic Montano
Branch Manager
STATE OF FLORIDA
Professional Engineer No. 84146
This item has been digitally signed and sealed by Thomas Dominic
Montano on the date adjacent to the seal. Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1