Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED Manual D
Job #: 1001 Performed by Mustafa Turk for: COORONA LLC 805 VIRGINIA AVE STE 16 FORT PIERCE, FL 34982 Phone: 772-468-6969 shafiq0123@yahoo.com TURKS A/C INC 3338 ENTERPRISE RD BAY1 FORT PIERCE, FL 34982 Phone: 772-519-0147 mturk2001@aol.com Scale: 1 : 98 Page 1 Right-Suite® Universal 2021 21.0.07 RSU65124 2021-Jun-22 13:04:30 ...\Wrightsoft HVAC\Coorona LLC.rup N Level 1 KITCHEN FAMILYLIVING BED1BATHBED2BED3 UTILITY ENTRANCE PATIO 3'0"W x 7'0"H H/W 126 cfm 126 cfm 2'6"W x 5'0"H 2'6"W x 5'0"H 2'6"W x 5'0"H 3'4"W x 5'0"H 2'6"W x 5'0"H 2'6"W x 5'0"H 2'6"W x 3'5"H 2'6"W x 5'0"H 2'6"W x 5'0"H 2'6"W x 5'0"H 2'6"W x 5'0"H 2'6"W x 3'4"H 2'6"W x 3'4"H 2'6"W x 3'4"H 2'6"W x 3'4"H 5'0"W x 7'0"H 5'0"W x 7'0"H 2'6"W x 3'4"H 2'6"W x 3'4"H 3'0"W x 7'0"H 8'0"W x 3'8"H 12 " 12 " 12 " 12 " 8 " 12 " 12'-0"12'-0"7'-0"12'-0" 43'-0" 8'-0" 14'-0" 12'-0" 34'-0" 16'-0"15'-0"12'-0" 43'-0" 12'-0" 11'-0"34'-0"7 " 7 " 8'-0" 4'-0" 7'-0" 215 cfm 176 cfm 8 " A/H 6'-0" 198 cfm 8 "8 " 101 cfm 7 " 8 " 51 cfm 10'0"W x 8'0"H 4'0"W x 8'0"H 6 " 15 " 5'0"W x 8'0"H 1098 cfm 12 " 8 " 242 cfm 8 " Bold/italic values have been manually overridden 2021-Jun-22 13:04:17 Right-Suite® Universal 2021 21.0.07 RSU65124 Page 1 ...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E 1001Job:Duct System Summary JUNE 18, 2021Date:Entire House Mustafa TurkBy: TURKS A/C INC 3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co Project Information COORONA LLCFor: 805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982 Phone: 772-468-6969 Email: shafiq0123@yahoo.com CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O1.00in H2O1.00 Available static pressure in H2O-0.5in H2O-0.5 Supply / return available pressure -0.250 / -0.250 in H2O in H2O-0.250 / -0.250 Lowest friction rate in/100ft1.000in/100ft1.000 Actual air flow cfm1098cfm1098 Total effective length (TEL) ft118 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk 00VlFx0x04.01.0002751739hBATH 95.013.9VlFx0x08.01.0001621762529hBED1 95.09.2VlFx0x07.01.000821011455hBED2-A 105.013.1VlFx0x08.01.0002332423479hBED3 95.013.4VlFx0x08.01.0001271982843hFAMILY 95.014.0VlFx0x08.01.0002151925071cKITCHEN 95.09.2VlFx0x07.01.000126682980cLIVING 95.09.4VlFx0x07.01.000126682980cLIVING-A Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb16 0x 10980 1098 0 0 0 0 x0 0 VlFx 2021-Jun-22 13:04:17 Right-Suite® Universal 2021 21.0.07 RSU65124 Page 1 ...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E 1001Job:Duct system multi orientation report JUNE 18, 2021Date:Entire House Mustafa TurkBy: TURKS A/C INC 3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co Project Information COORONA LLCFor: 805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982 Phone: 772-468-6969 Email: shafiq0123@yahoo.com Group 1: ( N, NE, E, SE, S, SW, W, NW) Duct Name (SE)(E)(NE)(N) Duct SizeReg SizeReg CFMDuct SizeReg SizeReg CFMDuct SizeReg SizeReg CFMDuct SizeReg SizeReg CFM Supply Branches BATH 46x655 h46x651 h46x655 h46x651 h BED1 812x12187 h812x12176 h812x12187 h812x12176 h BED2-A 710x10114 c710x10141 c710x10119 c710x10101 h BED3 812x12257 h812x12242 h812x12257 h812x12242 h FAMILY 812x12210 h812x12198 h812x12210 h812x12198 h KITCHEN 812x12268 c812x12245 c812x12234 c812x12215 c LIVING 710x1092 c710x1068 h710x10104 c710x10126 c LIVING-A 710x1092 c710x1068 h710x10104 c710x10126 c Return Branches rb16 023x231164 c023x231096 c023x231165 c023x231098 c Friction Rates Heating FR 1.0001.0001.0001.000 Cooling FR 1.0001.0001.0001.000 2021-Jun-22 13:04:17 Right-Suite® Universal 2021 21.0.07 RSU65124 Page 2 ...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E Project Information COORONA LLCFor: 805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982 Phone: 772-468-6969 Email: shafiq0123@yahoo.com Duct Name (NW)(W)(SW)(S) Duct SizeReg SizeReg CFMDuct SizeReg SizeReg CFMDuct SizeReg SizeReg CFMDuct SizeReg SizeReg CFM Supply Branches BATH 46x656 h46x656 c46x655 h46x651 h BED1 812x12193 h812x12196 c812x12226 c812x12198 c BED2-A 710x10134 c710x10168 c710x10134 c710x10101 h BED3 812x12265 h812x12248 h812x12257 h812x12241 h FAMILY 812x12217 h812x12202 h812x12210 h812x12197 h KITCHEN 812x12234 c812x12222 c812x12231 c812x12242 c LIVING 710x10104 c710x1070 h710x1087 c710x10108 c LIVING-A 710x10104 c710x1070 h710x1087 c710x10108 c Return Branches rb16 023x231202 c023x231122 c023x231164 c023x231093 c Friction Rates Heating FR 1.0001.0001.0001.000 Cooling FR 1.0001.0001.0001.000 2021-Jun-22 13:04:17 Right-Suite® Universal 2021 21.0.07 RSU65124 Page 3 ...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E Project Information COORONA LLCFor: 805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982 Phone: 772-468-6969 Email: shafiq0123@yahoo.com Duct Name SmalestLargest Duct SizeReg SizeReg CFMDuct SizeReg SizeReg CFM Supply Branches BATH 46x651 h46x656 h BED1 812x12176 h812x12226 c BED2-A 710x10101 h710x10168 c BED3 812x12241 h812x12265 h FAMILY 812x12197 h812x12217 h KITCHEN 812x12215 c812x12268 c LIVING 710x1068 h710x10126 c LIVING-A 710x1068 h710x10126 c Return Branches rb16 023x231093 c023x231202 c Friction Rates Heating FR 1.0001.000 Cooling FR 1.0001.000 2021-Jun-22 13:04:17 Right-Suite® Universal 2021 21.0.07 RSU65124 Page 4 ...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E Background Color Legend Yellow background Duct Size - duct size is smaller than the largest duct size in the row Reg Size - register size is smaller than the largest register size in the row Reg CFM - register design cfm is larger than 150 CFM Friction Rate - friction rate is outside ACCA Manual-D recommended range (0.06 - 0.18) Pink background column header Largest coolling load orientation Bold/italic values have been manually overridden 2021-Jun-22 13:04:18 Right-Suite® Universal 2021 21.0.07 RSU65124 Page 1 ...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E 1001Job:Static Pressure and Friction Rate JUNE 18, 2021Date:Entire House Mustafa TurkBy: TURKS A/C INC 3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co Project Information COORONA LLCFor: 805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982 Phone: 772-468-6969 Email: shafiq0123@yahoo.com Available Static Pressure CoolingHeating (in H2O)(in H2O) 0.500.50External static pressure Pressure losses 00Coil 00Heat exchanger 0.500.50Supply diffusers 00Return grilles 0.500.50Filter 00Humidifier 00Balancing damper 00Other device -0.5-0.5Available static pressure Total Effective Length ReturnSupply (ft)(ft) 013Measured length of run-out 00Measured length of trunk 0105Equivalent length of fittings 0118Total length 118Total effective length Friction Rate CoolingHeating (in/100ft)(in/100ft) > 0.181.000> 0.181.000Supply Ducts > 0.181.000> 0.181.000Return Ducts Fitting Equivalent Length Details 4AD=60, 1A=35, 11G=5, 11G=5: TotalEL=105Supply TotalEL=0Return