HomeMy WebLinkAboutAPPROVED Manual JCalculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-22 13:02:45
Right-Suite® Universal 2021 21.0.07 RSU65124 Page 1
...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Load Short Form JUNE 18, 2021Date:Entire House Mustafa TurkBy:
TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
Project Information
COORONA LLCFor:
805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982
Phone: 772-468-6969
Email: shafiq0123@yahoo.com
Design Information
InfiltrationClgHtg
SimplifiedMethod9042Outside db (°F)
AverageConstruction quality7570Inside db (°F)
1 (Average)Fireplaces1528Design TD (°F)
M-Daily range
5030Inside humidity (%)
611Moisture difference (gr/lb)
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make ALLIED
Trade Trade ALLIED
Model Cond 4AC16L36P-50A
AHRI ref Coil BCE5E36M
AHRI ref 202870272
Efficiency 100 EFF Efficiency 0 SEER
Heating input kW4.6 Sensible cooling Btuh0
Heating output Btuh15764 Latent cooling Btuh0
Temperature rise °F13 Total cooling Btuh0
Actual air flow cfm1098 Actual air flow cfm1098
Air flow factor cfm/Btuh0.070 Air flow factor cfm/Btuh0.042
Static pressure in H2O0.50 Static pressure in H2O0.50
Space thermostat Load sensible heat ratio 0.85
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft²)(Btuh)(Btuh)(cfm)(cfm)
KITCHEN 120 2759 5071 192 215
FAMILY 224 2843 3004 198 127
LIVING 210 1959 5960 136 252
BED1 144 2529 3817 176 162
BATH 84 739 630 51 27
BED2 144 1455 1931 101 82
BED3 144 3479 5515 242 233
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-22 13:02:45
Right-Suite® Universal 2021 21.0.07 RSU65124 Page 2
...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
Entire House 1070 15764 25929 1098 1098
Other equip loads 0 0
Equip. @ 0.95 RSM 24632
Latent cooling 4521
TOTALS 1070 15764 29154 1098 1098
2021-Jun-22 13:02:45
Right-Suite® Universal 2021 21.0.07 RSU65124 Page 1
...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Building Analysis JUNE 18, 2021Date:Entire House Mustafa TurkBy:
TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
Project Information
COORONA LLCFor:
805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982
Phone: 772-468-6969
Email: shafiq0123@yahoo.com
Design Conditions
Location: CoolingHeatingIndoor:7570Indoor temperature (°F)Fort Pierce, FL, US
1528Design TD (°F)ft25Elevation:
5030Relative humidity (%)°N27Latitude:
Outdoor:61.51.1Moisture difference (gr/lb)CoolingHeating
Infiltration:9042Dry bulb (°F)
SimplifiedMethod)M(20-Daily range (°F)
AverageConstruction quality78-Wet bulb (°F)
1 (Average)Fireplaces7.515.0Wind speed (mph)
Heating
Walls
Glazing
Doors
Ceilings Floors
Infiltration
Ducts
% of loadBtuhBtuh/ft²Component
14.923552.5Walls
21.9346016.0Glazing
6.399410.9Doors
6.19590.9Ceilings
7.311501.11.1Floors
17.828112.3Infiltration
25.64036Ducts
00Piping
00Humidification
00Ventilation0Adjustments
100.015764Total
Cooling
Walls
Glazing
DoorsCeilings FloorsInfiltration
Ducts
Internal Gains
% of loadBtuhBtuh/ft²Component
7.018082.0Walls
35.3914142.2Glazing
3.694010.3Doors
6.617121.6Ceilings
2.46160.6Floors
2.46350.5Infiltration
22.75895Ducts
00Ventilation
20.05180Internal gains
00Blower
0Adjustments
100.025929Total
Latent Cooling Load = 4521 Btuh
Overall U-value = 0.098 Btuh/ft²-°F
Data entries checked.
2021-Jun-22 13:02:45
Right-Suite® Universal 2021 21.0.07 RSU65124 Page 1
...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Component Constructions JUNE 18, 2021Date:Entire House Mustafa TurkBy:
TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
Project Information
COORONA LLCFor:
805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982
Phone: 772-468-6969
Email: shafiq0123@yahoo.com
Design Conditions
Location: CoolingHeatingIndoor:
7570Indoor temperature (°F)Fort Pierce, FL, US
1528Design TD (°F)ft25Elevation:
5030Relative humidity (%)°N27Latitude:
Outdoor:61.51.1Moisture difference (gr/lb)CoolingHeating
Infiltration:9042Dry bulb (°F)
SimplifiedMethod)M(20-Daily range (°F)
AverageConstruction quality78-Wet bulb (°F)
1 (Average)Fireplaces7.515.0Wind speed (mph)
Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr
BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft²
Walls
12C-0sw: Frm wall, stucco ext, r-13 cav ins, 1/2" gypsum board int fnsh,
2"x4" wood frm, 16" o.c. stud
5401.967032.5513.00.091276n
3821.964982.5513.00.091196e
5261.966852.5513.00.091269s
3601.964692.5513.00.091184w
18081.9623552.5513.00.091924all
Partitions
(none)
Windows
1D-c2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk;
6.67 ft head ht
67020.352716.000.57033n
258862.466216.000.57042e
169922.6120016.000.57075s
418462.4107116.000.57067w
914142.2346016.000.570217all
Doors
11D0: Door, wd sc type 36210.338210.900.39035n
36210.338210.900.39035e
21710.322910.900.39021w
94010.399410.900.39091all
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 1/2"
gypsum board int fnsh
17121.609590.9030.00.0321070
Floors
19A-19cvcp: Flr floor, frm flr, 8" thkns, carpet flr fnsh, r-19 cav ins, leaky
crwl ovr
6160.5811501.0819.00.0491070
2021-Jun-22 13:02:45
Right-Suite® Universal 2021 21.0.07 RSU65124 Page 2
...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Component Constructions JUNE 18, 2021Date:KITCHEN Mustafa TurkBy:
TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
Project Information
COORONA LLCFor:
805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982
Phone: 772-468-6969
Email: shafiq0123@yahoo.com
Design Conditions
Location: CoolingHeatingIndoor:
7570Indoor temperature (°F)Fort Pierce, FL, US
1528Design TD (°F)ft25Elevation:
5030Relative humidity (%)°N27Latitude:
Outdoor:61.51.1Moisture difference (gr/lb)CoolingHeating
Infiltration:9042Dry bulb (°F)
SimplifiedMethod)M(20-Daily range (°F)
AverageConstruction quality78-Wet bulb (°F)
1 (Average)Fireplaces7.515.0Wind speed (mph)
Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr
BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft²
Walls
12C-0sw: Frm wall, stucco ext, r-13 cav ins, 1/2" gypsum board int fnsh,
2"x4" wood frm, 16" o.c. stud
2021.962642.5513.00.091104n
931.961212.5513.00.09148e
841.961102.5513.00.09143w
3801.964942.5513.00.091194all
Partitions
(none)
Windows
1D-c2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk;
6.67 ft head ht
33520.326316.000.57017n
102962.426316.000.57017e
136441.352716.000.57033all
Doors
11D0: Door, wd sc type 21710.322910.900.39021w
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 1/2"
gypsum board int fnsh
1921.601080.9030.00.032120
Floors
19A-19cvcp: Flr floor, frm flr, 8" thkns, carpet flr fnsh, r-19 cav ins, leaky
crwl ovr
690.581291.0819.00.049120
2021-Jun-22 13:02:45
Right-Suite® Universal 2021 21.0.07 RSU65124 Page 3
...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Component Constructions JUNE 18, 2021Date:FAMILY Mustafa TurkBy:
TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
Project Information
COORONA LLCFor:
805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982
Phone: 772-468-6969
Email: shafiq0123@yahoo.com
Design Conditions
Location: CoolingHeatingIndoor:
7570Indoor temperature (°F)Fort Pierce, FL, US
1528Design TD (°F)ft25Elevation:
5030Relative humidity (%)°N27Latitude:
Outdoor:61.51.1Moisture difference (gr/lb)CoolingHeating
Infiltration:9042Dry bulb (°F)
SimplifiedMethod)M(20-Daily range (°F)
AverageConstruction quality78-Wet bulb (°F)
1 (Average)Fireplaces7.515.0Wind speed (mph)
Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr
BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft²
Walls
12C-0sw: Frm wall, stucco ext, r-13 cav ins, 1/2" gypsum board int fnsh,
2"x4" wood frm, 16" o.c. stud
2181.962842.5513.00.091112n
1511.961962.5513.00.09177e
3691.964802.5513.00.091189all
Partitions
(none)
Windows
1D-c2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk;
6.67 ft head ht
33520.326316.000.57017n
Doors
11D0: Door, wd sc type 36210.338210.900.39035e
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 1/2"
gypsum board int fnsh
3581.602010.9030.00.032224
Floors
19A-19cvcp: Flr floor, frm flr, 8" thkns, carpet flr fnsh, r-19 cav ins, leaky
crwl ovr
1290.582411.0819.00.049224
2021-Jun-22 13:02:45
Right-Suite® Universal 2021 21.0.07 RSU65124 Page 4
...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Component Constructions JUNE 18, 2021Date:LIVING Mustafa TurkBy:
TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
Project Information
COORONA LLCFor:
805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982
Phone: 772-468-6969
Email: shafiq0123@yahoo.com
Design Conditions
Location: CoolingHeatingIndoor:
7570Indoor temperature (°F)Fort Pierce, FL, US
1528Design TD (°F)ft25Elevation:
5030Relative humidity (%)°N27Latitude:
Outdoor:61.51.1Moisture difference (gr/lb)CoolingHeating
Infiltration:9042Dry bulb (°F)
SimplifiedMethod)M(20-Daily range (°F)
AverageConstruction quality78-Wet bulb (°F)
1 (Average)Fireplaces7.515.0Wind speed (mph)
Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr
BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft²
Walls
12C-0sw: Frm wall, stucco ext, r-13 cav ins, 1/2" gypsum board int fnsh,
2"x4" wood frm, 16" o.c. stud
1461.961902.5513.00.09175w
Partitions
(none)
Windows
1D-c2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk;
6.67 ft head ht
233962.459916.000.57038w
Doors
(none)
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 1/2"
gypsum board int fnsh
3361.601880.9030.00.032210
Floors
19A-19cvcp: Flr floor, frm flr, 8" thkns, carpet flr fnsh, r-19 cav ins, leaky
crwl ovr
1210.582261.0819.00.049210
2021-Jun-22 13:02:45
Right-Suite® Universal 2021 21.0.07 RSU65124 Page 5
...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Component Constructions JUNE 18, 2021Date:BED1 Mustafa TurkBy:
TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
Project Information
COORONA LLCFor:
805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982
Phone: 772-468-6969
Email: shafiq0123@yahoo.com
Design Conditions
Location: CoolingHeatingIndoor:
7570Indoor temperature (°F)Fort Pierce, FL, US
1528Design TD (°F)ft25Elevation:
5030Relative humidity (%)°N27Latitude:
Outdoor:61.51.1Moisture difference (gr/lb)CoolingHeating
Infiltration:9042Dry bulb (°F)
SimplifiedMethod)M(20-Daily range (°F)
AverageConstruction quality78-Wet bulb (°F)
1 (Average)Fireplaces7.515.0Wind speed (mph)
Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr
BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft²
Walls
12C-0sw: Frm wall, stucco ext, r-13 cav ins, 1/2" gypsum board int fnsh,
2"x4" wood frm, 16" o.c. stud
1391.961812.5513.00.09171e
1391.961812.5513.00.09171s
2781.963622.5513.00.091142all
Partitions
(none)
Windows
1D-c2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk;
6.67 ft head ht
155962.439916.000.57025e
56522.639916.000.57025s
212442.579816.000.57050all
Doors
(none)
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 1/2"
gypsum board int fnsh
2301.601290.9030.00.032144
Floors
19A-19cvcp: Flr floor, frm flr, 8" thkns, carpet flr fnsh, r-19 cav ins, leaky
crwl ovr
830.581551.0819.00.049144
2021-Jun-22 13:02:45
Right-Suite® Universal 2021 21.0.07 RSU65124 Page 6
...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Component Constructions JUNE 18, 2021Date:BATH Mustafa TurkBy:
TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
Project Information
COORONA LLCFor:
805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982
Phone: 772-468-6969
Email: shafiq0123@yahoo.com
Design Conditions
Location: CoolingHeatingIndoor:
7570Indoor temperature (°F)Fort Pierce, FL, US
1528Design TD (°F)ft25Elevation:
5030Relative humidity (%)°N27Latitude:
Outdoor:61.51.1Moisture difference (gr/lb)CoolingHeating
Infiltration:9042Dry bulb (°F)
SimplifiedMethod)M(20-Daily range (°F)
AverageConstruction quality78-Wet bulb (°F)
1 (Average)Fireplaces7.515.0Wind speed (mph)
Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr
BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft²
Walls
12C-0sw: Frm wall, stucco ext, r-13 cav ins, 1/2" gypsum board int fnsh,
2"x4" wood frm, 16" o.c. stud
931.961212.5513.00.09148s
Partitions
(none)
Windows
1D-c2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk;
6.67 ft head ht
19222.613616.000.5709s
Doors
(none)
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 1/2"
gypsum board int fnsh
1341.60750.9030.00.03284
Floors
19A-19cvcp: Flr floor, frm flr, 8" thkns, carpet flr fnsh, r-19 cav ins, leaky
crwl ovr
480.58901.0819.00.04984
2021-Jun-22 13:02:45
Right-Suite® Universal 2021 21.0.07 RSU65124 Page 7
...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Component Constructions JUNE 18, 2021Date:BED2 Mustafa TurkBy:
TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
Project Information
COORONA LLCFor:
805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982
Phone: 772-468-6969
Email: shafiq0123@yahoo.com
Design Conditions
Location: CoolingHeatingIndoor:
7570Indoor temperature (°F)Fort Pierce, FL, US
1528Design TD (°F)ft25Elevation:
5030Relative humidity (%)°N27Latitude:
Outdoor:61.51.1Moisture difference (gr/lb)CoolingHeating
Infiltration:9042Dry bulb (°F)
SimplifiedMethod)M(20-Daily range (°F)
AverageConstruction quality78-Wet bulb (°F)
1 (Average)Fireplaces7.515.0Wind speed (mph)
Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr
BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft²
Walls
12C-0sw: Frm wall, stucco ext, r-13 cav ins, 1/2" gypsum board int fnsh,
2"x4" wood frm, 16" o.c. stud
1391.961812.5513.00.09171s
Partitions
(none)
Windows
1D-c2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk;
6.67 ft head ht
56522.639916.000.57025s
Doors
(none)
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 1/2"
gypsum board int fnsh
2301.601290.9030.00.032144
Floors
19A-19cvcp: Flr floor, frm flr, 8" thkns, carpet flr fnsh, r-19 cav ins, leaky
crwl ovr
830.581551.0819.00.049144
2021-Jun-22 13:02:45
Right-Suite® Universal 2021 21.0.07 RSU65124 Page 8
...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Component Constructions JUNE 18, 2021Date:BED3 Mustafa TurkBy:
TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
Project Information
COORONA LLCFor:
805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982
Phone: 772-468-6969
Email: shafiq0123@yahoo.com
Design Conditions
Location: CoolingHeatingIndoor:
7570Indoor temperature (°F)Fort Pierce, FL, US
1528Design TD (°F)ft25Elevation:
5030Relative humidity (%)°N27Latitude:
Outdoor:61.51.1Moisture difference (gr/lb)CoolingHeating
Infiltration:9042Dry bulb (°F)
SimplifiedMethod)M(20-Daily range (°F)
AverageConstruction quality78-Wet bulb (°F)
1 (Average)Fireplaces7.515.0Wind speed (mph)
Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr
BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft²
Walls
12C-0sw: Frm wall, stucco ext, r-13 cav ins, 1/2" gypsum board int fnsh,
2"x4" wood frm, 16" o.c. stud
1191.961552.5513.00.09161n
1551.962022.5513.00.09179s
1301.961692.5513.00.09166w
4041.965272.5513.00.091207all
Partitions
(none)
Windows
1D-c2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk;
6.67 ft head ht
37722.626616.000.57017s
184662.447216.000.57030w
222348.073816.000.57046all
Doors
11D0: Door, wd sc type 36210.338210.900.39035n
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 1/2"
gypsum board int fnsh
2301.601290.9030.00.032144
Floors
19A-19cvcp: Flr floor, frm flr, 8" thkns, carpet flr fnsh, r-19 cav ins, leaky
crwl ovr
830.581551.0819.00.049144
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-22 13:02:45
Right-Suite® Universal 2021 21.0.07 RSU65124 Page 1
...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Project Summary JUNE 18, 2021Date:Entire House Mustafa TurkBy:
TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
Project Information
COORONA LLCFor:805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982
Phone: 772-468-6969Email: shafiq0123@yahoo.com
Notes:
Design Information
Fort Pierce, FL, USWeather:
Winter Design Conditions Summer Design Conditions
Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75
Design TD °F28 Design TD °F15Daily range M
Relative humidity %50Moisture difference gr/lb61
Heating Summary Sensible Cooling Equipment Load Sizing
Structure Btuh11728 Structure Btuh20033
Ducts Btuh4036 Ducts Btuh5895Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0
(none) (none)Humidification Btuh0 Blower Btuh0
Piping Btuh0Equipment load Btuh15764 Use manufacturer's data n
Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh24632
Method Latent Cooling Equipment Load SizingSimplified
Construction quality Average1 (Average)Fireplaces Structure Btuh2949
Ducts Btuh1572Central vent (0 cfm) Btuh0
CoolingHeating (none)10701070Area (ft²) Equipment latent load Btuh4521
85608560Volume (ft³)Air changes/hour 0.270.64 Equipment Total Load (Sen+Lat)Btuh29154
Equiv. AVF (cfm) 3991 Req. total capacity at 0.70 SHR ton2.9
Heating Equipment Summary Cooling Equipment Summary
Make Make ALLIEDTrade Trade ALLIED
Model Cond 4AC16L36P-50AAHRI ref Coil BCE5E36M
AHRI ref 202870272Efficiency 100 EFF Efficiency 0 SEER
Heating input kW4.6 Sensible cooling Btuh0Heating output Btuh15764 Latent cooling Btuh0
Temperature rise °F13 Total cooling Btuh0Actual air flow cfm1098 Actual air flow cfm1098
Air flow factor cfm/Btuh0.070 Air flow factor cfm/Btuh0.042Static pressure in H2O0.50 Static pressure in H2O0.50
Space thermostat Load sensible heat ratio 0.85
2021-Jun-22 13:02:45
Right-Suite® Universal 2021 21.0.07 RSU65124 Page 1
...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:AED Assessment JUNE 18, 2021Date:Entire House Mustafa TurkBy:
TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
Project Information
COORONA LLCFor:
805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982
Phone: 772-468-6969
Email: shafiq0123@yahoo.com
Design Conditions
Location: CoolingHeatingIndoor:
7570Indoor temperature (°F)Fort Pierce, FL, US
1528Design TD (°F)ft25Elevation:
5030Relative humidity (%)°N27Latitude:
Outdoor:61.51.1Moisture difference (gr/lb)CoolingHeating
Infiltration:9042Dry bulb (°F)
)M(20-Daily range (°F)
78-Wet bulb (°F)
7.515.0Wind speed (mph)
Test for Adequate Exposure Diversity
Hourly Glazing Load
Hourly Average AED limitGlazing load (Btuh)Hour of Day
0
1,000
2,000
3,000
4,000
5,000
6,000
7,000
8,000
9,000
10,000
11,000
12,000
8 9 10 11 12 13 14 15 16 17 18 19 20
Maximum hourly glazing load exceeds average by 28.9%.
House has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 Btuh
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-22 13:02:46Right-Suite® Universal 2021 21.0.07 RSU65124 Page 1...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Right-J® Worksheet JUNE 18, 2021Date:Entire House Mustafa TurkBy:TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
1 Room name Entire House KITCHEN
2 Exposed wall 154.0 ft 31.0 ft
3 Room height 8.0 ft 8.0 heat/coolft
4 Room dimensions ft8.0x15.0
5 Room area 1070.0 ft²120.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.552.55 1.961.96 344 276 703 540 120 104 264 202
.GG 1D-c2ov1D-c2ov 0.5700.570 nn 15.9615.96 20.2920.29 33 0 527 670 17 0 263 335
.DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 35 35 382 362 0 0 0 0
.WW 12C-0sw12C-0sw 0.0910.091 ee 2.552.55 1.961.96 272 196 498 382 64 48 121 93
11 GG 1D-c2ov1D-c2ov 0.5700.570 ee 15.9615.96 62.3662.36 42 0 662 2588 17 0 263 1029
DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 35 35 382 362 0 0 0 0
WW 12C-0sw12C-0sw 0.0910.091 ss 2.552.55 1.961.96 344 269 685 526 0 0 0 0
GG 1D-c2ov1D-c2ov 0.5700.570 ss 15.9615.96 22.6122.61 75 0 1200 1699 0 0 0 0
WW 12C-0sw12C-0sw 0.0910.091 ww 2.552.55 1.961.96 272 184 469 360 64 43 110 84
GG 1D-c2ov1D-c2ov 0.5700.570 ww 15.9615.96 62.3662.36 67 0 1071 4184 0 0 0 0
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 21 21 229 217 21 21 229 217
CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 1070 1070 959 1712 120 120 108 192
FF 19A-19cvcp19A-19cvcp 0.0490.049 --1.081.08 0.580.58 1070 1070 1150 616 120 120 129 69
6 c) AED excursion 0 -432
Envelope loss/gain 8917 14218 1487 1790
12 a) Infiltration 2811 635 566 128
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 6 1380 0 0
Appliances/other 3800 2000
Subtotal (lines 6 to 13)11728 20033 2053 3918
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 11728 20033 2053 3918
15 Duct loads 34%29%4036 5895 34%29%706 1153
Total room load 15764 25929 2759 5071
Air required (cfm)Air required (cfm)1098 1098 192 215
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-22 13:02:46Right-Suite® Universal 2021 21.0.07 RSU65124 Page 2...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Right-J® Worksheet JUNE 18, 2021Date:Entire House Mustafa TurkBy:TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
1 Room name FAMILY LIVING
2 Exposed wall 30.0 ft 14.0 ft
3 Room height 8.0 heat/coolft 8.0 heat/coolft
4 Room dimensions ft14.0x16.0 ft14.0x15.0
5 Room area 224.0 ft²210.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.552.55 1.961.96 128 112 284 218 0 0 0 0
.GG 1D-c2ov1D-c2ov 0.5700.570 nn 15.9615.96 20.2920.29 17 0 263 335 0 0 0 0
.DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
.WW 12C-0sw12C-0sw 0.0910.091 ee 2.552.55 1.961.96 112 77 196 151 0 0 0 0
11 GG 1D-c2ov1D-c2ov 0.5700.570 ee 15.9615.96 62.3662.36 0 0 0 0 0 0 0 0
DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 35 35 382 362 0 0 0 0
WW 12C-0sw12C-0sw 0.0910.091 ss 2.552.55 1.961.96 0 0 0 0 0 0 0 0
GG 1D-c2ov1D-c2ov 0.5700.570 ss 15.9615.96 22.6122.61 0 0 0 0 0 0 0 0
WW 12C-0sw12C-0sw 0.0910.091 ww 2.552.55 1.961.96 0 0 0 0 112 75 190 146
GG 1D-c2ov1D-c2ov 0.5700.570 ww 15.9615.96 62.3662.36 0 0 0 0 38 0 599 2339
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 224 224 201 358 210 210 188 336
FF 19A-19cvcp19A-19cvcp 0.0490.049 --1.081.08 0.580.58 224 224 241 129 210 210 226 121
6 c) AED excursion -256 706
Envelope loss/gain 1567 1297 1202 3648
12 a) Infiltration 548 124 256 58
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 0 0 0 0
Appliances/other 900 900
Subtotal (lines 6 to 13)2115 2321 1458 4605
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 2115 2321 1458 4605
15 Duct loads 34%29%728 683 34%29%502 1355
Total room load 2843 3004 1959 5960
Air required (cfm)Air required (cfm)198 127 136 252
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-22 13:02:46Right-Suite® Universal 2021 21.0.07 RSU65124 Page 3...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Right-J® Worksheet JUNE 18, 2021Date:Entire House Mustafa TurkBy:TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
1 Room name BED1 BATH
2 Exposed wall 24.0 ft 7.0 ft
3 Room height 8.0 heat/coolft 8.0 heat/coolft
4 Room dimensions ft12.0x12.0 ft12.0x7.0
5 Room area 144.0 ft²84.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.552.55 1.961.96 0 0 0 0 0 0 0 0
.GG 1D-c2ov1D-c2ov 0.5700.570 nn 15.9615.96 20.2920.29 0 0 0 0 0 0 0 0
.DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
.WW 12C-0sw12C-0sw 0.0910.091 ee 2.552.55 1.961.96 96 71 181 139 0 0 0 0
11 GG 1D-c2ov1D-c2ov 0.5700.570 ee 15.9615.96 62.3662.36 25 0 399 1559 0 0 0 0
DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
WW 12C-0sw12C-0sw 0.0910.091 ss 2.552.55 1.961.96 96 71 181 139 56 48 121 93
GG 1D-c2ov1D-c2ov 0.5700.570 ss 15.9615.96 22.6122.61 25 0 399 565 9 0 136 192
WW 12C-0sw12C-0sw 0.0910.091 ww 2.552.55 1.961.96 0 0 0 0 0 0 0 0
GG 1D-c2ov1D-c2ov 0.5700.570 ww 15.9615.96 62.3662.36 0 0 0 0 0 0 0 0
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 144 144 129 230 84 84 75 134
FF 19A-19cvcp19A-19cvcp 0.0490.049 --1.081.08 0.580.58 144 144 155 83 84 84 90 48
6 c) AED excursion -325 -10
Envelope loss/gain 1444 2391 422 458
12 a) Infiltration 438 99 128 29
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 2 460 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)1882 2949 550 487
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 1882 2949 550 487
15 Duct loads 34%29%648 868 34%29%189 143
Total room load 2529 3817 739 630
Air required (cfm)Air required (cfm)176 162 51 27
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-22 13:02:46Right-Suite® Universal 2021 21.0.07 RSU65124 Page 4...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Right-J® Worksheet JUNE 18, 2021Date:Entire House Mustafa TurkBy:TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
1 Room name BED2 BED3
2 Exposed wall 12.0 ft 36.0 ft
3 Room height 8.0 heat/coolft 8.0 heat/coolft
4 Room dimensions ft12.0x12.0 ft12.0x12.0
5 Room area 144.0 ft²144.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.552.55 1.961.96 0 0 0 0 96 61 155 119
.GG 1D-c2ov1D-c2ov 0.5700.570 nn 15.9615.96 20.2920.29 0 0 0 0 0 0 0 0
.DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 0 0 0 0 35 35 382 362
.WW 12C-0sw12C-0sw 0.0910.091 ee 2.552.55 1.961.96 0 0 0 0 0 0 0 0
11 GG 1D-c2ov1D-c2ov 0.5700.570 ee 15.9615.96 62.3662.36 0 0 0 0 0 0 0 0
DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
WW 12C-0sw12C-0sw 0.0910.091 ss 2.552.55 1.961.96 96 71 181 139 96 79 202 155
GG 1D-c2ov1D-c2ov 0.5700.570 ss 15.9615.96 22.6122.61 25 0 399 565 17 0 266 377
WW 12C-0sw12C-0sw 0.0910.091 ww 2.552.55 1.961.96 0 0 0 0 96 66 169 130
GG 1D-c2ov1D-c2ov 0.5700.570 ww 15.9615.96 62.3662.36 0 0 0 0 30 0 472 1846
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 144 144 129 230 144 144 129 230
FF 19A-19cvcp19A-19cvcp 0.0490.049 --1.081.08 0.580.58 144 144 155 83 144 144 155 83
6 c) AED excursion -35 350
Envelope loss/gain 864 983 1931 3653
12 a) Infiltration 219 49 657 148
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 2 460 2 460
Appliances/other 0 0
Subtotal (lines 6 to 13)1083 1492 2588 4261
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 1083 1492 2588 4261
15 Duct loads 34%29%373 439 34%29%891 1254
Total room load 1455 1931 3479 5515
Air required (cfm)Air required (cfm)101 82 242 233
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-22 13:02:46Right-Suite® Universal 2021 21.0.07 RSU65124 Page 1...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Right-J8® Form J1 JUNE 18, 2021Date:Entire House Mustafa TurkBy:TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
1 Name of Room Entire House KITCHEN
2 Running Feet of Exposed Wall 154.0 ft 31.0 ft
3 Ceiling Ht (Ft) and Gross Wall Area (SqFt)8.0 ft²2424.0ft 8.0 ft²336.0ft
4 Room Dimensions (Ft) and Floor Plan Area (SqFt)ft²1070.0 15.0 x 8.0 ft ft²120.0
5 Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²1070.0°0 ft²120.0°
Type of
Exposure
Const.,
Number
Type of
Exposure
Const.,
Number
Panel
Faces
HTMPanel
Faces
HTM Area or
Length
BtuhArea or
Length
Btuh Area or
Length
BtuhArea or
Length
Btuh
Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg
6 WallWall 12C-0sw12C-0sw nn 2.552.55 1.961.96 344 703 540 120 264 202
.GlazGlaz 1D-c2ov1D-c2ov nn 15.9615.96 20.2920.29 33 527 670 17 263 335
.DoorDoor 11D011D0 nn 10.9210.92 10.3410.34 35 382 362 0 0 0
.WallWall 12C-0sw12C-0sw ee 2.552.55 1.961.96 272 498 382 64 121 93
11 GlazGlaz 1D-c2ov1D-c2ov ee 15.9615.96 62.3662.36 42 662 2588 17 263 1029
DoorDoor 11D011D0 ee 10.9210.92 10.3410.34 35 382 362 0 0 0
WallWall 12C-0sw12C-0sw ss 2.552.55 1.961.96 344 685 526 0 0 0
GlazGlaz 1D-c2ov1D-c2ov ss 15.9615.96 22.6122.61 75 1200 1699 0 0 0
WallWall 12C-0sw12C-0sw ww 2.552.55 1.961.96 272 469 360 64 110 84
GlazGlaz 1D-c2ov1D-c2ov ww 15.9615.96 62.3662.36 67 1071 4184 0 0 0
DoorDoor 11D011D0 ww 10.9210.92 10.3410.34 21 229 217 21 229 217
CeilCeil 16B-30ad16B-30ad --0.900.90 1.601.60 1070 959 1712 120 108 192
FlorFlor 19A-19cvcp19A-19cvcp --1.081.08 0.580.58 1070 1150 616 120 129 69
Infiltration Heating Load (Btuh)0.640.64 2811 566
Effect WAR WAR
12 Sensible Load (Btuh)ACH 1.00 635 0.20 128
0.270.27
Latent Load (Btuh)1609
Internal a Occupants at 230 and 200 Btuh 6 1380 1200 0 0 0
b Scenario number 3800 2000
13 c Default Adjustments
d Custom Appliances 0 0 0 0
e Plants 140 0
14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 11728 20033 2949 2053 3918
Duct EHLF & ESGF 0.3440.344 0.2940.294 4036 5895 706 1153
15 Loads
ELG 1572 176
Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00 0 0 0
17 Winter Humidification Load Gal/Day 00 0
18 Piping Load 0
19 Blower Heat 0
20 AED Excursion & Latent Moisture Migration Load 0 -432
21 Total Load Sum lines 13 through 19Sum lines 13 through 19 15764 25929 4521 2759 5071
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-22 13:02:46Right-Suite® Universal 2021 21.0.07 RSU65124 Page 2...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Right-J8® Form J1 JUNE 18, 2021Date:Entire House Mustafa TurkBy:TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
1 Name of Room FAMILY LIVING
2 Running Feet of Exposed Wall 30.0 ft 14.0 ft
3 Ceiling Ht (Ft) and Gross Wall Area (SqFt)8.0 ft²360.0ft 8.0 ft²312.0ft
4 Room Dimensions (Ft) and Floor Plan Area (SqFt)16.0 x 14.0 ft ft²224.0 15.0 x 14.0 ft ft²210.0
5 Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²224.0°0 ft²210.0°
Type of
Exposure
Const.,
Number
Type of
Exposure
Const.,
Number
Panel
Faces
HTMPanel
Faces
HTM Area or
Length
BtuhArea or
Length
Btuh Area or
Length
BtuhArea or
Length
Btuh
Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg
6 WallWall 12C-0sw12C-0sw nn 2.552.55 1.961.96 128 284 218 0 0 0
.GlazGlaz 1D-c2ov1D-c2ov nn 15.9615.96 20.2920.29 17 263 335 0 0 0
.DoorDoor 11D011D0 nn 10.9210.92 10.3410.34 0 0 0 0 0 0
.WallWall 12C-0sw12C-0sw ee 2.552.55 1.961.96 112 196 151 0 0 0
11 GlazGlaz 1D-c2ov1D-c2ov ee 15.9615.96 62.3662.36 0 0 0 0 0 0
DoorDoor 11D011D0 ee 10.9210.92 10.3410.34 35 382 362 0 0 0
WallWall 12C-0sw12C-0sw ss 2.552.55 1.961.96 0 0 0 0 0 0
GlazGlaz 1D-c2ov1D-c2ov ss 15.9615.96 22.6122.61 0 0 0 0 0 0
WallWall 12C-0sw12C-0sw ww 2.552.55 1.961.96 0 0 0 112 190 146
GlazGlaz 1D-c2ov1D-c2ov ww 15.9615.96 62.3662.36 0 0 0 38 599 2339
DoorDoor 11D011D0 ww 10.9210.92 10.3410.34 0 0 0 0 0 0
CeilCeil 16B-30ad16B-30ad --0.900.90 1.601.60 224 201 358 210 188 336
FlorFlor 19A-19cvcp19A-19cvcp --1.081.08 0.580.58 224 241 129 210 226 121
Infiltration Heating Load (Btuh)0.640.64 548 256
Effect WAR WAR
12 Sensible Load (Btuh)ACH 0.19 124 0.09 58
0.270.27
Latent Load (Btuh)
Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0
b Scenario number 900 900
13 c Default Adjustments
d Custom Appliances 0 0 0 0
e Plants 0 0
14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 2115 2321 1458 4605
Duct EHLF & ESGF 0.3440.344 0.2940.294 728 683 502 1355
15 Loads
ELG 329 309
Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00
17 Winter Humidification Load Gal/Day 00
18 Piping Load
19 Blower Heat
20 AED Excursion & Latent Moisture Migration Load -256 706
21 Total Load Sum lines 13 through 19Sum lines 13 through 19 2843 3004 1959 5960
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-22 13:02:46Right-Suite® Universal 2021 21.0.07 RSU65124 Page 3...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Right-J8® Form J1 JUNE 18, 2021Date:Entire House Mustafa TurkBy:TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
1 Name of Room BED1 BATH
2 Running Feet of Exposed Wall 24.0 ft 7.0 ft
3 Ceiling Ht (Ft) and Gross Wall Area (SqFt)8.0 ft²384.0ft 8.0 ft²264.0ft
4 Room Dimensions (Ft) and Floor Plan Area (SqFt)12.0 x 12.0 ft ft²144.0 7.0 x 12.0 ft ft²84.0
5 Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²144.0°0 ft²84.0°
Type of
Exposure
Const.,
Number
Type of
Exposure
Const.,
Number
Panel
Faces
HTMPanel
Faces
HTM Area or
Length
BtuhArea or
Length
Btuh Area or
Length
BtuhArea or
Length
Btuh
Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg
6 WallWall 12C-0sw12C-0sw nn 2.552.55 1.961.96 0 0 0 0 0 0
.GlazGlaz 1D-c2ov1D-c2ov nn 15.9615.96 20.2920.29 0 0 0 0 0 0
.DoorDoor 11D011D0 nn 10.9210.92 10.3410.34 0 0 0 0 0 0
.WallWall 12C-0sw12C-0sw ee 2.552.55 1.961.96 96 181 139 0 0 0
11 GlazGlaz 1D-c2ov1D-c2ov ee 15.9615.96 62.3662.36 25 399 1559 0 0 0
DoorDoor 11D011D0 ee 10.9210.92 10.3410.34 0 0 0 0 0 0
WallWall 12C-0sw12C-0sw ss 2.552.55 1.961.96 96 181 139 56 121 93
GlazGlaz 1D-c2ov1D-c2ov ss 15.9615.96 22.6122.61 25 399 565 9 136 192
WallWall 12C-0sw12C-0sw ww 2.552.55 1.961.96 0 0 0 0 0 0
GlazGlaz 1D-c2ov1D-c2ov ww 15.9615.96 62.3662.36 0 0 0 0 0 0
DoorDoor 11D011D0 ww 10.9210.92 10.3410.34 0 0 0 0 0 0
CeilCeil 16B-30ad16B-30ad --0.900.90 1.601.60 144 129 230 84 75 134
FlorFlor 19A-19cvcp19A-19cvcp --1.081.08 0.580.58 144 155 83 84 90 48
Infiltration Heating Load (Btuh)0.640.64 438 128
Effect WAR WAR
12 Sensible Load (Btuh)ACH 0.16 99 0.05 29
0.270.27
Latent Load (Btuh)
Internal a Occupants at 230 and 200 Btuh 2 460 400 0 0 0
b Scenario number 0 0
13 c Default Adjustments
d Custom Appliances 0 0 0 0
e Plants 40 0
14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 1882 2949 550 487
Duct EHLF & ESGF 0.3440.344 0.2940.294 648 868 189 143
15 Loads
ELG 212 123
Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00
17 Winter Humidification Load Gal/Day 00
18 Piping Load
19 Blower Heat
20 AED Excursion & Latent Moisture Migration Load -325 -10
21 Total Load Sum lines 13 through 19Sum lines 13 through 19 2529 3817 739 630
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-22 13:02:46Right-Suite® Universal 2021 21.0.07 RSU65124 Page 4...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Right-J8® Form J1 JUNE 18, 2021Date:Entire House Mustafa TurkBy:TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
1 Name of Room BED2 BED3
2 Running Feet of Exposed Wall 12.0 ft 36.0 ft
3 Ceiling Ht (Ft) and Gross Wall Area (SqFt)8.0 ft²384.0ft 8.0 ft²384.0ft
4 Room Dimensions (Ft) and Floor Plan Area (SqFt)12.0 x 12.0 ft ft²144.0 12.0 x 12.0 ft ft²144.0
5 Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²144.0°0 ft²144.0°
Type of
Exposure
Const.,
Number
Type of
Exposure
Const.,
Number
Panel
Faces
HTMPanel
Faces
HTM Area or
Length
BtuhArea or
Length
Btuh Area or
Length
BtuhArea or
Length
Btuh
Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg
6 WallWall 12C-0sw12C-0sw nn 2.552.55 1.961.96 0 0 0 96 155 119
.GlazGlaz 1D-c2ov1D-c2ov nn 15.9615.96 20.2920.29 0 0 0 0 0 0
.DoorDoor 11D011D0 nn 10.9210.92 10.3410.34 0 0 0 35 382 362
.WallWall 12C-0sw12C-0sw ee 2.552.55 1.961.96 0 0 0 0 0 0
11 GlazGlaz 1D-c2ov1D-c2ov ee 15.9615.96 62.3662.36 0 0 0 0 0 0
DoorDoor 11D011D0 ee 10.9210.92 10.3410.34 0 0 0 0 0 0
WallWall 12C-0sw12C-0sw ss 2.552.55 1.961.96 96 181 139 96 202 155
GlazGlaz 1D-c2ov1D-c2ov ss 15.9615.96 22.6122.61 25 399 565 17 266 377
WallWall 12C-0sw12C-0sw ww 2.552.55 1.961.96 0 0 0 96 169 130
GlazGlaz 1D-c2ov1D-c2ov ww 15.9615.96 62.3662.36 0 0 0 30 472 1846
DoorDoor 11D011D0 ww 10.9210.92 10.3410.34 0 0 0 0 0 0
CeilCeil 16B-30ad16B-30ad --0.900.90 1.601.60 144 129 230 144 129 230
FlorFlor 19A-19cvcp19A-19cvcp --1.081.08 0.580.58 144 155 83 144 155 83
Infiltration Heating Load (Btuh)0.640.64 219 657
Effect WAR WAR
12 Sensible Load (Btuh)ACH 0.08 49 0.23 148
0.270.27
Latent Load (Btuh)
Internal a Occupants at 230 and 200 Btuh 2 460 400 2 460 400
b Scenario number 0 0
13 c Default Adjustments
d Custom Appliances 0 0 0 0
e Plants 40 60
14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 1083 1492 2588 4261
Duct EHLF & ESGF 0.3440.344 0.2940.294 373 439 891 1254
15 Loads
ELG 212 212
Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00
17 Winter Humidification Load Gal/Day 00
18 Piping Load
19 Blower Heat
20 AED Excursion & Latent Moisture Migration Load -35 350
21 Total Load Sum lines 13 through 19Sum lines 13 through 19 1455 1931 3479 5515
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-22 13:02:47
Right-Suite® Universal 2021 21.0.07 RSU65124 Page 1
...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:Loads for Multiple Orientations JUNE 18, 2021Date:Entire House Mustafa TurkBy:
TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
Project Information
COORONA LLCFor:
805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982
Phone: 772-468-6969
Email: shafiq0123@yahoo.com
Design Conditions
Location: CoolingHeatingIndoor:
7570Indoor temperature (°F)Fort Pierce, FL, US
1528Design TD (°F)ft25Elevation:
5030Relative humidity (%)°N27Latitude:
Outdoor:61.51.1Moisture difference (gr/lb)CoolingHeating
Infiltration:9042Dry bulb (°F)
)M(20-Daily range (°F)
78-Wet bulb (°F)
7.515.0Wind speed (mph)
Front Door North Northeast East Southeast South Southwest West Northwest
Sensible Load (Btuh) 24597 26093 24632 26849 25101 26069 24521 26078
Latent Load (Btuh) 4521 4656 4521 4659 4521 4656 4516 4656
Total Load (Btuh) 29118 30749 29154 31508 29622 30724 29038 30734
Heating AVF (cfm) 1096 1165 1098 1202 1122 1164 1093 1164
Cooling AVF (cfm) 1096 1165 1098 1202 1122 1164 1093 1164
Building Orientation Cooling Load
Total Cooling Load (Btuh)Direction Front Door faces
0
10000
20000
30000
40000
N NE E SE S SW W NW
Front Door faces EastCurrent Orientation:
Front Door faces SoutheastHighest Cooling Load:
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-22 13:02:48
Right-Suite® Universal 2021 21.0.07 RSU65124 Page 1
...Drive\Documents\Wrightsoft HVAC\Coorona LLC.rup Calc = MJ8 Front Door faces: E
1001Job:J1 Form - Worksheet A JUNE 18, 2021Date:Entire House Mustafa TurkBy:
TURKS A/C INC
3338 ENTERPRISE RD BAY1, FORT PIERCE, FL 34982 Phone: 772-519-0147 Email: mturk2001@aol.com License: CAC1820815, co
Supporting Detail
Project Name:JUNE 18, 2021Coorona LLC Date:
Address: 805 VIRGINIA AVE STE 16, FORT PIERCE, FL 34982
Phone:1001772-468-6969 Job ID:
Worksheet A
Location and Design Conditions
Weather Location: Fort Pierce, FL, US 2725 Latitude =Elevation =
Indoor Conditions, Heating: 70 °FDB = %50°F75%30 RH =DB =Indoor Conditions, Cooling:RH =
Table 1 Conditions 99% DB = 42 °F Mgr/lb61°F90 Daily Range =Grains Difference =1% DB =
Design Temperature Differences °F15°F28 CTD =HTD =
Job #: 1001
Performed by Mustafa Turk for:
COORONA LLC
805 VIRGINIA AVE STE 16
FORT PIERCE, FL 34982
Phone: 772-468-6969
shafiq0123@yahoo.com
TURKS A/C INC
3338 ENTERPRISE RD BAY1
FORT PIERCE, FL 34982
Phone: 772-519-0147
mturk2001@aol.com
Scale: 1 : 98
Page 1
Right-Suite® Universal 2021
21.0.07 RSU65124
2021-Jun-22 13:03:09
...\Wrightsoft HVAC\Coorona LLC.rup
N
Level 1
KITCHEN
FAMILYLIVING
BED1BATHBED2BED3
UTILITY
ENTRANCE
PATIO
3'0"W x 7'0"H
H/W
126 cfm
126 cfm
2'6"W x 5'0"H
2'6"W x 5'0"H
2'6"W x 5'0"H
3'4"W x 5'0"H 2'6"W x 5'0"H 2'6"W x 5'0"H 2'6"W x 3'5"H 2'6"W x 5'0"H 2'6"W x 5'0"H
2'6"W x 5'0"H
2'6"W x 5'0"H
2'6"W x 3'4"H
2'6"W x 3'4"H
2'6"W x 3'4"H 2'6"W x 3'4"H
5'0"W x 7'0"H
5'0"W x 7'0"H
2'6"W x 3'4"H 2'6"W x 3'4"H
3'0"W x 7'0"H
8'0"W x 3'8"H
12 "
12 "
12 "
12 "
8 "
12 "
12'-0"12'-0"7'-0"12'-0"
43'-0"
8'-0"
14'-0"
12'-0"
34'-0"
16'-0"15'-0"12'-0"
43'-0"
12'-0"
11'-0"34'-0"7 "
7 "
8'-0"
4'-0"
7'-0"
215 cfm
176 cfm
8 "
A/H
6'-0"
198 cfm
8 "8 "
101 cfm
7 "
8 "
51 cfm
10'0"W x 8'0"H
4'0"W x 8'0"H
6 "
15 "
5'0"W x 8'0"H
1098 cfm
12 "
8 "
242 cfm
8 "