Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION (2)
Job: 3405 Industrial 31st Stre.., +f + wrightsoft Pro��e� Summary Date: June 30,2021 Entire House By: Anthony Aversa Sea Coast Air Conditioning 3108 InduMal 31st Slreel, For( Plerce, FL 3, For. Notes: Phone:772466-2400 Email: Tomaria LLC 3405 Industrial 31 st Street, Fort Pierce, FL 34946 3405 Industrial 31st Street, Fort Pierce, 34946 Design=informa#ion:..: Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 3555 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 11 Btuh Piping 0 Btuh Equipment load 3567 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Healing coolingg Area (ff2) 18D 180 Volume (fi') 1440 1440 Ai r changge's/hour 0.61 0.32 EquivAVF (cfm) 15 8 Heating Equipment Summary Make n/a Trade n/a Model n/a AHRI ref n/a Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 0 Btuh 0 Btuh 201 cfm 0.056 cfm/Btuh 0 in H2O Summer Design Conditions Outside clb 95 OF Inside db. 75 OF Design TD 20 OF Daily range M Relative humidity 50 % Moisture difference 53 grAb Sensible Cooling Equipment load Sizing Structure 4411 Btuh Ducts 0 Btuh Central vent (0 cfm) (none) Blower 0 1707 Btuh Btuh Use manufacturer's data Rate/swing multiplier Equipment sensible load n 1.00 6118 Btuh Latent Cooling Equipment Load Sizing Structure 2378 Btuh Ducts. 0 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 2378 Btuh Equipment Total Load Sen+Lat) 8496 Btuh Req. total capacity at 0.70 SHR 0.7 ton Cooling Equipment Summary Make Daikin Trade Daikin Cond RK09AXVJU Coil FfK09AXJU AHRI ref 205782844 Efficiency 12.5 EER,19 SEER Sensible cooling 6230 Btuh Latent cool i ng 2670 Btuh Total cooling $900 Btuh Actual air flow 201 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.72 BoWlearic values have been manually overridden Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -F�&- wrightsoft` 2021•Jut3007:33:03 A:Ei Right-Suite®Uriversal201919.0.13 RSU28644 Pago 1 ACCA C:1Users�aversaVesldop%GdwoodBlock.rup Calc=MA FrordDoor faces: N Manual S Compliance Report Job: 3405Industrial 31stStre... wrigh- tsoft° p Date: June 30,2021 Entire House By: Anthony Aversa Sea Coast Air Conditioning 3108 Irdustrial 31,4 Street, Fort Pierce, FL 34946 Phone: 772 466-2400 PCB: dlspatch@seacoastairmm :-Ptbject Information For: Tomaria LLC 3405 Industrial 31st Street, Fort Pierce, FL 34946 Cooling Equipment,._.: Design Conditions. Outdoor design DB: 95.0°F Sensible gain: 6118 Btuh Outdoor design WB: 78.0°F Latent gain: 2378 Btuh Indoor design DB: 75.0°F Total gain: 8496 Btuh indoor RH: 50% Estimated airflow: 201 cf-n Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitAC Manufacturer. Daikin Actual airflow: :-,201 cfrn Sensible capacity: 6230 Btuh Latent capacity: 2670 Btuh Total capacity: 8900 Btuh Model: RK09AXVJU+FTK09AXJU 102% of load 112% of load 105% of load SHR: 70 % Heating Equipment Design Conditions DB: 42.0°F Heat loss: 3567 ' Btuh. Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Manufacturer Actual airflow: Output capacity: Model: 201 cfm 0 Btuh 0% of load Meets all requirements ofACCA Manual S. Entering coil DB: 82.9°F Entering coil WB: 65.2°F Entering coil DB: 0°F- Temp. rise: 0 °F wrightsoftF, 2021-An-30 07:33:03 ,., Flight-Sate®Uriversal 2019 19.0.13 RSU28644 Page 1 ACC% C-.WserslaversaUesktopllodcwoodBlodc.np Calc=MJ8 Front Door faces: N