Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETs y, LLLLL ST. LUCI ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C %Z3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,S,6,7 Asphaltic Shingles A, 8, D Concrete or Clay Tile A, B, D, E 7A, 1,2,3,4,5,6,7 Meta! Roofs B, D 1,2,3,4,5,G,7 Wood Shingles and Shakes A, B, D 1,2,4,5,6,7 Other As Applicable 1,2,3,45,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3, Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5, Municipal Permit Application 6, Owners Notification for Roofing Considerations (Reroofing Only) 7, Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 Section A (General Information) Master Permit No. Contractors Name: Collins Roofing Inc, —> Job Add Process No. License u CCC-058011 ROOF CATEGORY ❑ 1pw Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles Asphaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE '' ❑ � New roof ❑ Repair ❑ Maintenance Reroofing ❑Recovering ROOF SYSTEM INFORMATION // , Low Slope Roof Area (SF) —> Steep Sloped Roof Area 150 `; It > _ —> Total (SF) Section 8 (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.. Section D (Steep Slope Roof System) C�l�c::' COV V-6 � � �r Roof System Manufacturer: 1-1 OV Notice of Acceptance Number: FL It Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calc a ns): 4 Zone 1:.�Zone 2e:.�Zone 2n: one 2r:�one 3e: �TZone 3r: Deck Type: 5/8" Plywood Type Underlayment Self Adhesive Underlayment T( 1 �)u Roof Slope: 12 Ifrsulationc NIA Fire Barrier: NIA RidgeVer%tion7 —>FastenerType & Spacing: 6 Nails PerShingle - 1 1/4" Coil N Is Adhesive Type: Bituman Tar Type Cap Sheet N/A Mean Roof Height, 15 ft - Roof Covering: Dimensional Asphault Shingles Type & Size Drip 2" x2" Galv. Steel Edge: