Loading...
HomeMy WebLinkAboutAPPROVED 12 WYZSKOWSKI- ENERGY CALC 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 63/18/2021 12:19 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY PACE 2000, INC. ALAN AND JONI WYZSKOWSKI WYZSKOWSKI RESIDENCE Street: City, State, Zip: FORT PIERCE , FL , 34951 8004 HAMILTON AVENUE Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Detached 1 No 1726 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : Sgl, U=0.56 148.42 ft² SHGC=0.24 Sgl, U=0.65 131.56 ft² SHGC=0.22 Sgl, U=0.26 25.00 ft² SHGC=0.16 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 1726.00 ft² R=f t ² R=f t ² 10. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 1710.30 ft² b. Frame - Wood, Adjacent R=11.0 187.08 ft² c. N/A R=f t ² 11. Ceiling Types a. Roof Deck (Unvented)R=20.0 1726.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 13. Cooling systems 14. Heating systems 15. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:2.439 ft. Area Weighted Average SHGC:0.225 Description Area Insulation Area Insulation Area Insulation Area 16. Credits None 3 (313.0 sqft.) (1897.4 sqft.) (1726.0 sqft.) (1726.0 sqft.) Conditioned floor area below grade (ft²)0 a. Central Unit a. Electric Strip Heat k B t u / h r 28.6 SEER:16.00 Efficiency k B t u / h r Efficiency 27.0 COP:1.00 f t ² R 6 140 EF: 0.980 8. Skylights c. U-Factor:(AVG) S H G C ( A V G ) : N/A N/A f t ² Area Glass/Floor Area: 0.181 Total Proposed Modified Loads: Total Baseline Loads: 60.77 60.89 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2020 3-18-2021 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY PACE 2000, INC. 1 ALAN AND JONI WYZSKOW WYZSKOWSKI RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 1726 3 New (From Plans) Detached Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , 34951 FORT PIERCE , St. Lucie 8004 HAMILTON AVEN Street Address Comment: ESSEX MODIFIED MODEL Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days MoistureRangeWinter Summer CLIMATE 90 70 7529962 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 1726 16743.6 Number NameAreaVolume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 MASTER BEDROO 216 2008.8 No 01 Yes Yes1Yes 2 M WIC 1 35 325.5 No 0 Yes Yes1Yes 3 MASTER BATH 110 1023 No 0 Yes Yes1Yes 4 LAUNDRY70651 No 0 Yes Yes1No 5 DINING 120 1200 No 0 Yes Yes1Yes 6 FOYER 64 640 No 0 Yes Yes1Yes 7 BEDROOM 3 169 1571.7 No 01 Yes Yes1Yes 8 CLST 3 16 148.8 No 0 Yes Yes1Yes 9 BATH 2 54 502.2 No 0 Yes Yes1Yes 10 CLST 2 18 167.4 No 0 Yes Yes1Yes 11 BEDROOM 2 169 1571.7 No 01 Yes Yes1Yes 12 KITCHEN2642455.2 Yes 0 Yes Yes1Yes 13 HALL 36 335 No 0 Yes Yes1No 14 M WIC 2 35 326 No 0 Yes Yes1No 15 LIVING ROOM 330 3630 No 0 Yes Yes1Yes 16 M TOILET20188 No 0 Yes Yes1No # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 216 ft² 010______ Slab-On-Grade Edge Insulatio - - - -28 ft MASTER BEDRO 2 35 ft² 010______ Slab-On-Grade Edge Insulatio - - - -7 ft M WIC 1 3/18/2021 12:19 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 3 110 ft² 010______ Slab-On-Grade Edge Insulatio - - - -10 ft MASTER BATH 4 70 ft² 010______ Slab-On-Grade Edge Insulatio - - - -1 ft LAUNDRY 5 120 ft² 010______ Slab-On-Grade Edge Insulatio - - - -14 ft DINING 6 64 ft² 010______ Slab-On-Grade Edge Insulatio - - - -8 ft FOYER 7 169 ft² 010______ Slab-On-Grade Edge Insulatio - - - -32 ft BEDROOM 3 8 16 ft² 010______ Slab-On-Grade Edge Insulatio - - - -2 ft CLST 3 9 54 ft² 010______ Slab-On-Grade Edge Insulatio - - - -6 ft BATH 2 10 18 ft² 010______ Slab-On-Grade Edge Insulatio - - - -2 ft CLST 2 11 169 ft² 010______ Slab-On-Grade Edge Insulatio - - - -26 ft BEDROOM 2 12 264 ft² 010______ Slab-On-Grade Edge Insulatio - - - -12 ft KITCHEN 13 36 ft² 010______ Slab-On-Grade Edge Insulatio - - - -1 ft HALL 14 35 ft² 010______ Slab-On-Grade Edge Insulatio - - - -1 ft M WIC 2 15 330 ft² 010______ Slab-On-Grade Edge Insulatio - - - -15 ft LIVING ROOM 16 20 ft² 010______ Slab-On-Grade Edge Insulatio - - - -1 ft M TOILET #Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1Hip Metal 1930 ft² Light 0.2 20 26.57______No0 ft² 0.9 NoN ATTIC #Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 1726 ft² N N0 3/18/2021 12:19 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT #Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented)0 216 ft² 0.1Wood______MASTER BEDRO Blown 2 Under Attic (Unvented)0 35 ft² 0.1 Wood______M WIC 1 Blown 3 Under Attic (Unvented)0 110 ft² 0.1Wood______MASTER BATH Blown 4 Under Attic (Unvented)0 70 ft² 0.1 Wood______LAUNDRY Blown 5 Under Attic (Unvented)0 120 ft² 0.1Wood______DINING Blown 6 Under Attic (Unvented)0 64 ft² 0.1 Wood______FOYER Blown 7 Under Attic (Unvented)0 169 ft² 0.1Wood______BEDROOM 3 Blown 8 Under Attic (Unvented)0 16 ft² 0.1 Wood______CLST 3 Blown 9 Under Attic (Unvented)0 54 ft² 0.1 Wood______BATH 2 Blown 10 Under Attic (Unvented)0 18 ft² 0.1Wood______CLST 2 Blown 11 Under Attic (Unvented)0 169 ft² 0.1Wood______BEDROOM 2 Blown 12 Under Attic (Unvented)0 264 ft² 0.1Wood______KITCHEN Blown 13 Under Attic (Unvented)0 36 ft² 0.1Wood______HALL Blown 14 Under Attic (Unvented)0 35 ft² 0.1Wood______M WIC 2 Blown 15 Under Attic (Unvented)0 330 ft² 0.1Wood______LIVING ROOM Blown 16 Under Attic (Unvented)0 20 ft² 0.1Wood______M TOILET Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0MASTER BE 040 1 3 9NConcrete Block - Int Insul 0.30Exterior121.3 ft² ____ 2 4.1 0MASTER BE 040 1 9 9WConcrete Block - Int Insul 0.30Exterior177.3 ft² ____ 3 4.1 0M WIC 1 040 6 9WConcrete Block - Int Insul 0.30Exterior56.0 ft² ____ 4 4.1 0MASTER BA 040 1 0 9WConcrete Block - Int Insul 0.30Exterior93.3 ft² ____ 5 11 0MASTER BA 040 8 9S Frame - Wood 0.30.1Garage74.7 ft² ____ 6 11 0LAUNDRY040 7 9S Frame - Wood 0.30.1Garage65.3 ft² ____ 7 4.1 0DINING000 2 1 0EConcrete Block - Int Insul 0.30Exterior20.0 ft² ____ 8 4.1 0DINING000 1 2 1 0SConcrete Block - Int Insul 0.30Exterior120.0 ft² ____ 9 4.1 0FOYER000 8 1 0SConcrete Block - Int Insul 0.30Exterior80.0 ft² ____ 10 4.1 0BEDROOM 3 040 1 3 9EConcrete Block - Int Insul 0.30Exterior121.3 ft² ____ 11 4.1 0BEDROOM 3 040 6 9WConcrete Block - Int Insul 0.30Exterior56.0 ft² ____ 12 4.1 0BEDROOM 3 040 1 3 9SConcrete Block - Int Insul 0.30Exterior121.3 ft² ____ 13 4.1 0CLST 3 040 2 9EConcrete Block - Int Insul 0.30Exterior18.7 ft² ____ 14 4.1 0BATH 2 040 6 9EConcrete Block - Int Insul 0.30Exterior56.0 ft² ____ 15 4.1 0CLST 2 040 2 9EConcrete Block - Int Insul 0.30Exterior18.7 ft² ____ 16 4.1 0BEDROOM 2 040 1 3 9EConcrete Block - Int Insul 0.30Exterior121.3 ft² ____ 17 4.1 0BEDROOM 2 040 1 3 9NConcrete Block - Int Insul 0.30Exterior121.3 ft² ____ 18 4.1 0KITCHEN040 1 2 9NConcrete Block - Int Insul 0.30Exterior112.0 ft² ____ 19 4.1 0LIVING ROO 000 1 5 1 1NConcrete Block - Int Insul 0.30Exterior165.0 ft² ____ 20 11 0M TOILET 050 5 9S Frame - Wood 0.30.1Garage47.1 ft² ____ 21 4.1 0KITCHEN040 5 9WConcrete Block - Int Insul 0.30Exterior46.7 ft² ____ 22 4.1 0KITCHEN040 5 9EConcrete Block - Int Insul 0.30Exterior46.7 ft² ____ 23 4.1 0LAUNDRY040 4 9EConcrete Block - Int Insul 0.20Exterior37.3 ft² ____ 3/18/2021 12:19 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .23 20 ft² None______NW FOYER 863 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1N Low-E Single 0.65 0.22 35.6 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes1 Y 2W Low-E Single 0.56 0.24 20.0 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes2 Y 3W Low-E Single 0.56 0.24 12.0 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes4 Y 4S Low-E Single 0.56 0.24 36.0 ft² 5 ft 6 in 1 ft 4 in NoneMetal None______Yes8 Y 5S Low-E Single 0.26 0.16 16.0 ft² 7 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes9 Y 6S Low-E Single 0.56 0.24 20.4 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes12 Y 7E Low-E Single 0.39 0.25 8.0 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes14 Y 8N Low-E Single 0.56 0.24 20.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes17 Y 9N Low-E Single 0.65 0.22 96.0 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes19 Y 10 S Low-E Single 0.26 0.16 9.0 ft² 7 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes9 Y 11 W Low-E Single 0.56 0.24 10.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes21 Y 12 E Low-E Single 0.56 0.24 10.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes22 Y 13 N Low-E Single 0.56 0.24 20.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes18 Y # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1440 ft² 440 ft² 20 ft 9 ft 11______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1395.4 576.55.000308Wholehouse .0975143.72Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1Central Unit/SEER: 16 28.6 kBtu/hr 858 cfm 0.8______sys#1Split1 Singl 3/18/2021 12:19 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.98 50 gal 62.3 gal 120 deg None______None Garage FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6140 ft² Attic 14 ft² Default Leakage Attic ( D e f a u l t ) ______1 1 ( D e f a u l t ) TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 12345678910 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area T hickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 1 Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BATH Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY Default(8 lbs/sq.ft.f t ² f t 0.3 DINING Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3 Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft.f t ² f t 0.3 HALL Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 2 Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING ROOM Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET 3/18/2021 12:19 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� ����������������������������������������������������� 8004 HAMILTON AVENUE, FORT PIERCE, FL, 34951 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft²) New (From Plans) Detached 1 3 No 1726 7. Windows** a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.56 148.42 ft² SHGC=0.24 Sgl, U=0.65 131.56 ft² SHGC=0.22 Sgl, U=0.26 25.00 ft² SHGC=0.16 other (see details)8.00 ft² other (see details) 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 1726.00 ft² R= f t ² R= f t ² 10. Wall Type and Insulation a. Concrete Block - Int Insul, Exterior R=4.1 1710.30 ft² b. Frame - Wood, Adjacent R=11.0 187.08 ft² c. N/A R= f t ² 11. Ceiling Type and insulation level a. Roof Deck (Unvented)R=20.0 1726.00 ft² f t ² R =b. N/A c. N/A R = f t ² 12. Ducts, location & insulation level 13. Cooling systems 14. Heating systems k B t u / h r 15. Hot water systems a. Electric Cap: 50 gallons EF: 0.98 b. Conservation features None d. N/A R= f t ² Description Area Insulation Area Insulation Area Insulation Area Credits (Performance method)None Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 2.439 ft. 0.225 a. Electric Strip Heat 27.0 COP:1.00 a. Central Unit 28.6 SEER:16.00 k B t u / h r Efficiency Efficiency a. Sup: Attic, Ret: Attic, AH: Attic 6 140 R f t ² 8. Skylights a. U-Factor(AVG): S H G C ( A V G ) : Description Area N/A N/A f t ² I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature:Date: Address of New Home:City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. Page 1 of 1 FORM R405-2020 3/18/2021 12:19 PM ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������