HomeMy WebLinkAboutAPPROVED 12 WYZSKOWSKI- ENERGY CALC 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 63/18/2021 12:19 PM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
PACE 2000, INC.
ALAN AND JONI WYZSKOWSKI
WYZSKOWSKI RESIDENCE
Street:
City, State, Zip: FORT PIERCE , FL , 34951
8004 HAMILTON AVENUE
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Detached
1
No
1726
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
Sgl, U=0.56 148.42 ft²
SHGC=0.24
Sgl, U=0.65 131.56 ft²
SHGC=0.22
Sgl, U=0.26 25.00 ft²
SHGC=0.16
9. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 1726.00 ft²
R=f t ²
R=f t ²
10. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 1710.30 ft²
b. Frame - Wood, Adjacent R=11.0 187.08 ft²
c. N/A R=f t ²
11. Ceiling Types
a. Roof Deck (Unvented)R=20.0 1726.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
13. Cooling systems
14. Heating systems
15. Hot water systems
a. Electric Cap: 50 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:2.439 ft.
Area Weighted Average SHGC:0.225
Description Area
Insulation Area
Insulation Area
Insulation Area
16. Credits None
3
(313.0 sqft.)
(1897.4 sqft.)
(1726.0 sqft.)
(1726.0 sqft.)
Conditioned floor area below grade (ft²)0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
28.6 SEER:16.00
Efficiency
k B t u / h r Efficiency
27.0 COP:1.00
f t ² R
6 140
EF: 0.980
8. Skylights
c. U-Factor:(AVG)
S H G C ( A V G ) :
N/A
N/A
f t ²
Area
Glass/Floor Area: 0.181
Total Proposed Modified Loads:
Total Baseline Loads:
60.77
60.89 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2020
3-18-2021
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
PACE 2000, INC.
1
ALAN AND JONI WYZSKOW
WYZSKOWSKI RESIDENCE
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
1726
3
New (From Plans)
Detached
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL , 34951
FORT PIERCE ,
St. Lucie
8004 HAMILTON AVEN
Street Address
Comment: ESSEX MODIFIED MODEL
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days MoistureRangeWinter Summer
CLIMATE
90 70 7529962 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 1726 16743.6
Number NameAreaVolume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 MASTER BEDROO 216 2008.8 No 01 Yes Yes1Yes
2 M WIC 1 35 325.5 No 0 Yes Yes1Yes
3 MASTER BATH 110 1023 No 0 Yes Yes1Yes
4 LAUNDRY70651 No 0 Yes Yes1No
5 DINING 120 1200 No 0 Yes Yes1Yes
6 FOYER 64 640 No 0 Yes Yes1Yes
7 BEDROOM 3 169 1571.7 No 01 Yes Yes1Yes
8 CLST 3 16 148.8 No 0 Yes Yes1Yes
9 BATH 2 54 502.2 No 0 Yes Yes1Yes
10 CLST 2 18 167.4 No 0 Yes Yes1Yes
11 BEDROOM 2 169 1571.7 No 01 Yes Yes1Yes
12 KITCHEN2642455.2 Yes 0 Yes Yes1Yes
13 HALL 36 335 No 0 Yes Yes1No
14 M WIC 2 35 326 No 0 Yes Yes1No
15 LIVING ROOM 330 3630 No 0 Yes Yes1Yes
16 M TOILET20188 No 0 Yes Yes1No
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 216 ft² 010______ Slab-On-Grade Edge Insulatio - - - -28 ft MASTER BEDRO
2 35 ft² 010______ Slab-On-Grade Edge Insulatio - - - -7 ft M WIC 1
3/18/2021 12:19 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
3 110 ft² 010______ Slab-On-Grade Edge Insulatio - - - -10 ft MASTER BATH
4 70 ft² 010______ Slab-On-Grade Edge Insulatio - - - -1 ft LAUNDRY
5 120 ft² 010______ Slab-On-Grade Edge Insulatio - - - -14 ft DINING
6 64 ft² 010______ Slab-On-Grade Edge Insulatio - - - -8 ft FOYER
7 169 ft² 010______ Slab-On-Grade Edge Insulatio - - - -32 ft BEDROOM 3
8 16 ft² 010______ Slab-On-Grade Edge Insulatio - - - -2 ft CLST 3
9 54 ft² 010______ Slab-On-Grade Edge Insulatio - - - -6 ft BATH 2
10 18 ft² 010______ Slab-On-Grade Edge Insulatio - - - -2 ft CLST 2
11 169 ft² 010______ Slab-On-Grade Edge Insulatio - - - -26 ft BEDROOM 2
12 264 ft² 010______ Slab-On-Grade Edge Insulatio - - - -12 ft KITCHEN
13 36 ft² 010______ Slab-On-Grade Edge Insulatio - - - -1 ft HALL
14 35 ft² 010______ Slab-On-Grade Edge Insulatio - - - -1 ft M WIC 2
15 330 ft² 010______ Slab-On-Grade Edge Insulatio - - - -15 ft LIVING ROOM
16 20 ft² 010______ Slab-On-Grade Edge Insulatio - - - -1 ft M TOILET
#Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1Hip Metal 1930 ft² Light 0.2 20 26.57______No0 ft² 0.9 NoN
ATTIC
#Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 1726 ft² N N0
3/18/2021 12:19 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
#Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented)0 216 ft² 0.1Wood______MASTER BEDRO Blown
2 Under Attic (Unvented)0 35 ft² 0.1 Wood______M WIC 1 Blown
3 Under Attic (Unvented)0 110 ft² 0.1Wood______MASTER BATH Blown
4 Under Attic (Unvented)0 70 ft² 0.1 Wood______LAUNDRY Blown
5 Under Attic (Unvented)0 120 ft² 0.1Wood______DINING Blown
6 Under Attic (Unvented)0 64 ft² 0.1 Wood______FOYER Blown
7 Under Attic (Unvented)0 169 ft² 0.1Wood______BEDROOM 3 Blown
8 Under Attic (Unvented)0 16 ft² 0.1 Wood______CLST 3 Blown
9 Under Attic (Unvented)0 54 ft² 0.1 Wood______BATH 2 Blown
10 Under Attic (Unvented)0 18 ft² 0.1Wood______CLST 2 Blown
11 Under Attic (Unvented)0 169 ft² 0.1Wood______BEDROOM 2 Blown
12 Under Attic (Unvented)0 264 ft² 0.1Wood______KITCHEN Blown
13 Under Attic (Unvented)0 36 ft² 0.1Wood______HALL Blown
14 Under Attic (Unvented)0 35 ft² 0.1Wood______M WIC 2 Blown
15 Under Attic (Unvented)0 330 ft² 0.1Wood______LIVING ROOM Blown
16 Under Attic (Unvented)0 20 ft² 0.1Wood______M TOILET Blown
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0MASTER BE 040 1 3 9NConcrete Block - Int Insul 0.30Exterior121.3 ft² ____
2 4.1 0MASTER BE 040 1 9 9WConcrete Block - Int Insul 0.30Exterior177.3 ft² ____
3 4.1 0M WIC 1 040 6 9WConcrete Block - Int Insul 0.30Exterior56.0 ft² ____
4 4.1 0MASTER BA 040 1 0 9WConcrete Block - Int Insul 0.30Exterior93.3 ft² ____
5 11 0MASTER BA 040 8 9S Frame - Wood 0.30.1Garage74.7 ft² ____
6 11 0LAUNDRY040 7 9S Frame - Wood 0.30.1Garage65.3 ft² ____
7 4.1 0DINING000 2 1 0EConcrete Block - Int Insul 0.30Exterior20.0 ft² ____
8 4.1 0DINING000 1 2 1 0SConcrete Block - Int Insul 0.30Exterior120.0 ft² ____
9 4.1 0FOYER000 8 1 0SConcrete Block - Int Insul 0.30Exterior80.0 ft² ____
10 4.1 0BEDROOM 3 040 1 3 9EConcrete Block - Int Insul 0.30Exterior121.3 ft² ____
11 4.1 0BEDROOM 3 040 6 9WConcrete Block - Int Insul 0.30Exterior56.0 ft² ____
12 4.1 0BEDROOM 3 040 1 3 9SConcrete Block - Int Insul 0.30Exterior121.3 ft² ____
13 4.1 0CLST 3 040 2 9EConcrete Block - Int Insul 0.30Exterior18.7 ft² ____
14 4.1 0BATH 2 040 6 9EConcrete Block - Int Insul 0.30Exterior56.0 ft² ____
15 4.1 0CLST 2 040 2 9EConcrete Block - Int Insul 0.30Exterior18.7 ft² ____
16 4.1 0BEDROOM 2 040 1 3 9EConcrete Block - Int Insul 0.30Exterior121.3 ft² ____
17 4.1 0BEDROOM 2 040 1 3 9NConcrete Block - Int Insul 0.30Exterior121.3 ft² ____
18 4.1 0KITCHEN040 1 2 9NConcrete Block - Int Insul 0.30Exterior112.0 ft² ____
19 4.1 0LIVING ROO 000 1 5 1 1NConcrete Block - Int Insul 0.30Exterior165.0 ft² ____
20 11 0M TOILET 050 5 9S Frame - Wood 0.30.1Garage47.1 ft² ____
21 4.1 0KITCHEN040 5 9WConcrete Block - Int Insul 0.30Exterior46.7 ft² ____
22 4.1 0KITCHEN040 5 9EConcrete Block - Int Insul 0.30Exterior46.7 ft² ____
23 4.1 0LAUNDRY040 4 9EConcrete Block - Int Insul 0.20Exterior37.3 ft² ____
3/18/2021 12:19 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
#Door Type U-Value AreaStorms
DOORS
Ornt Space Width
Ft In Ft In
Height
1 Insulated .23 20 ft² None______NW FOYER 863
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1N Low-E Single 0.65 0.22 35.6 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes1 Y
2W Low-E Single 0.56 0.24 20.0 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes2 Y
3W Low-E Single 0.56 0.24 12.0 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes4 Y
4S Low-E Single 0.56 0.24 36.0 ft² 5 ft 6 in 1 ft 4 in NoneMetal None______Yes8 Y
5S Low-E Single 0.26 0.16 16.0 ft² 7 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes9 Y
6S Low-E Single 0.56 0.24 20.4 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes12 Y
7E Low-E Single 0.39 0.25 8.0 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes14 Y
8N Low-E Single 0.56 0.24 20.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes17 Y
9N Low-E Single 0.65 0.22 96.0 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes19 Y
10 S Low-E Single 0.26 0.16 9.0 ft² 7 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes9 Y
11 W Low-E Single 0.56 0.24 10.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes21 Y
12 E Low-E Single 0.56 0.24 10.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes22 Y
13 N Low-E Single 0.56 0.24 20.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes18 Y
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1440 ft² 440 ft² 20 ft 9 ft 11______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
1395.4 576.55.000308Wholehouse .0975143.72Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1Central Unit/SEER: 16 28.6 kBtu/hr 858 cfm 0.8______sys#1Split1 Singl
3/18/2021 12:19 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.98 50 gal 62.3 gal 120 deg None______None Garage
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6140 ft² Attic 14 ft² Default Leakage Attic ( D e f a u l t ) ______1 1 ( D e f a u l t )
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 12345678910 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area T hickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 MASTER BEDROO
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 1
Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY
Default(8 lbs/sq.ft.f t ² f t 0.3 DINING
Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft.f t ² f t 0.3 HALL
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 2
Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING ROOM
Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET
3/18/2021 12:19 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������
8004 HAMILTON AVENUE, FORT PIERCE, FL, 34951
7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft²)
New (From Plans)
Detached
1
3
No
1726
7. Windows**
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.56 148.42 ft²
SHGC=0.24
Sgl, U=0.65 131.56 ft²
SHGC=0.22
Sgl, U=0.26 25.00 ft²
SHGC=0.16
other (see details)8.00 ft²
other (see details)
9. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 1726.00 ft²
R= f t ²
R= f t ²
10. Wall Type and Insulation
a. Concrete Block - Int Insul, Exterior R=4.1 1710.30 ft²
b. Frame - Wood, Adjacent R=11.0 187.08 ft²
c. N/A R= f t ²
11. Ceiling Type and insulation level
a. Roof Deck (Unvented)R=20.0 1726.00 ft²
f t ² R =b. N/A
c. N/A R = f t ²
12. Ducts, location & insulation level
13. Cooling systems
14. Heating systems k B t u / h r
15. Hot water systems
a. Electric Cap: 50 gallons
EF: 0.98
b. Conservation features
None
d. N/A R= f t ²
Description Area
Insulation Area
Insulation Area
Insulation Area
Credits (Performance method)None
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
2.439 ft.
0.225
a. Electric Strip Heat 27.0 COP:1.00
a. Central Unit 28.6 SEER:16.00
k B t u / h r
Efficiency
Efficiency
a. Sup: Attic, Ret: Attic, AH: Attic 6 140
R f t ²
8. Skylights
a. U-Factor(AVG):
S H G C ( A V G ) :
Description Area
N/A
N/A
f t ²
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:Date:
Address of New Home:City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
Page 1 of 1
FORM R405-2020
3/18/2021 12:19 PM
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������