HomeMy WebLinkAboutAPPROVED 8004 Hamilton Ave bookletTABLE OF CONTENTS
A-0
COVER PAGE
A-1
FLOOR PLAN
A-2
ELEVATION (FRONT/REAR)
A-3
ELEVATION (LEFT/RIGHT)
E-1
ELECTRICAL
M-1
HVAC
S-1
FOUNDATION
S-2
DETAILS
S-3
BEAM &WALL
S-4
ROOF
S-5
FENESTRATION
Designed
AN
Drawn
CHID
Checked
AN
Date
5/11/2021
Scale,
NTs
E IN �11
OF RECORD
I EPH
P. WCARTY
R
E T, IN
0
OLD
RI DA
��
C.
WIND VERIFATION FORM
JURISDICTION
• •"
FRC
PROJECT ADDRESS
8004 HAMILTON AVE, FORT PIERCE, FL 34951
TYPE OF CONSTRUCTION
SPEEDWIND SECONDULTIMATE
DESIGN WIND SPEED• : MPH
WIND SPEED • ,
SPEEDNOMINAL DESIGN WIND • MPH
PRESSURE COEFFECIENT
0.18
EXPOSUREINTERNAL
•
IMPORTANCE FACTOR
CATEGORYBUILDING
MEAN BUILD HEIGHT
16-0"
,.OVERHANG
1.33 FEET
ROOF PITCH
6/12
ROOF TOP CHORD DEAD LOAD
15 PSF
ROOF TOP CHORD LIVE LOAD
20 PSF
ROOF BOTTOM CHORD DEAD LOAD
10.
ROOF BOTTOM CHORD LIVE LOAD
10.
MATERIAL
METAL
FLOORROOF
LIVE LOAD
FLOOR DEAD LOAD
N/A
NO
IMPACT RESISTANT ASSEMBLY
YES
i I 48"
67"
N 00
co
CD
F.G 4020 OBSCURE F.G 67"x 18" TRANSOM
NOA: 20-0401.10 NOA: 20-0401.10
UF:.390 UF:.390
SHH 36 SH 35 SHGC:.250 SHGC:.230
JOA: 20-0401.11 NOA: 20-0401.11 DESIGN PRESSURES DESIGN PRESSURES
REQUIRED: +31.2 / -33.9 REQUIRED: +31.2 / -33.9
U F:.560 U F:.560 PROVIDED: +80 / -80 PROVIDED: +80 / -80
SHGC:.2140 SHGC:.240
DESIGN PRESSURES DESIGN PRESSURES
EQUIRED: +31.2 / -33.8 REQUIRED: +31.2 / -33.8
PROVIDED:+65 / -80 PROVIDED: +65 / -80 6811
12" 36" 12"
SH 25 SHH 35 3068 w 12 IN.
NOA: 20-0401.11 - NOA: 20-0401 11 SIDELITES
142'/"
UF:.560
•
UF:.560
NOA # : 20468.2
3P3T SGD
SHGC:.240
SHGC:.240
U F..260
NOA:20-0429.09
DESIGN PRESSURES
-
DESIGN PRESSURES
SHGC:.160
UF:.650
REQUIRED: +31.2 / -33.8
REQUIRED: +31.2 / -33.8
DESIGN PRESSURES
SHGC:.220
PROVIDED: +65 / -80
PROVIDED: +65 / -80
REQUIRED: +31.2 / -33.
PROVIDED: +50 / -50
DESIGN PRESSURES
REQUIRED: +27.9 / -30.6
PROVIDED: +60 / -60
32'e
64"
0
00
74"
(0
r-
(2) SH 26
NOA: 20-0401.11
U F:.560
SHGC:.240
DESIGN PRESSURES
REQUIRED: +31.2 / -33.8
PROVIDED: +65 / -80
ELECTRICAL NOTES
1) ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH NEC (NFPA 70) 2026 EDITION
2) A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFACY
LAMPS OR MINIMUM OF 75% OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY
HIGH-EFFACY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED TO BE HIGH -EFFICIENCY LAMPS)
3) RECESSED LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONE AND UNCONDITIONED
SPACES
4) SMOKED DETECTORS TO BE 110V W/ BATTERY BACK-UP, ARC FAULT CIRCUIT
5) SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE DETECTOR ACTIVATES ALL SMOKE
DETECTOR IN THE RESIDENCE
6) PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FOR ALL CIRUITS SERVING: FAMILY ROOMS,DINING
ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS,
CLOSETS, HALLWAYS, OR SIMILAR ROOMS PER FBC AND NEC REQUIREMENTS
7) PROVIDE GROUND -FAULT CIRUIT INTERRUPTER PROTECTION FOR ALL 125 VOLT, SINGLE PHASE 15 AND
20 AMP CIRUITS SERVING: BATHROOMS, GARAGES, KITCHENS, ACCESSORY BUILDINGS, OUTDOORS, OR
WITHIN 72" OF EDGE OF ANY SINK.
8) CARON MENOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALL BEDROOMS
9) EXHAUST FANS TO BE VENTED THROUGH ROOF OR SOFFIT
10) PROVIDE TAPER RESISTANT RECEPTICLES PER NEC REQUIREMENTS
STRUCTURAL NOTES
1) DESIGN LOADS IN ACCORDANCE WITH ASCE 7-16
2) SOIL BEARING CAPICITY: 2500 PSF (MIN.)
3) ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICAL CELLS, AND COLUMNS SHALL HAVE A
MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS
4) SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM OF 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS.
SEE PLAN FOR SIZES AND STEEL REQUIREMENTS
5) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTINGS; 3"BEAMS; 1-1/2" SUSPENDED SLABS: 1-1/2"
6) LAPALL REINFORCING STEELA MINIMUM OF 48 BAR DIAMETER EXCEPTAS NOTED GRADE 60 STEEL.
MINIMUM IN BEAMS AND COLUMNS.
7) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONARY SHALL BE PRESSURE TREATED
8) SPLITTING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALLATION OF HARDWARE IS NOT
PERMITTED. -
9) UNLESS OTHERWISE NOTES, THE ONSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE
MANUFACTURER'S INSTRUCTIONS AND STANDARD PRACTICES.
10) UNLESS OTHERWISE NOTED, FOR EXTERIOR WALLS, EXTERIOR PLYWOOD SHEATHING AND INTERIOR
DRYWALL IS TO BE NAILED WITH 10d OR BETTER NAILS AT 6" O.C. AT EDGES AND FIELD OR SCREWED
WITH DRYWALL SCREWS 1-1/2" LONG AND 0.131 DIAMETER.
11) LINTELS SHALL HAVE A MINIMUM 4" BEARING EXCEPT RECESSED LINTELS SHALL HAVE 8" BEARING.
12) PROVIDE #5 CORNER BARS W/ 30" MIN. LAP SPLICE FOR BOND BEAM.
13) EXTERIOR FRAME WALL TO BE STUCCO OVER WIRELATHE W/ 11GA. 2" LONG NAILS WITH 3/8" DIA. HEAD AT
6" O.C. OVER (2) TWO LAYERS OF 15# FELT OR APIRROVED BUILDING WRAP OVER 19/32" CDX PLYWOOD
WITH IOd NAILS TO STUDS AT 6" O.C. PERIMETER AND FIELD.
14) BEARING POINTS OF TRUSSES SHALL HAVE VERTICAL STUDS IN A NUMBER EQUAL TO THE NUMBER OF
PLIES OF THE BEARING MEMEBER WHEN THE BEARING MEMBER IS (2) TWO OR MORE PLIES UNLESS
NOTED. 11 1
Wind Certification - Design Criteria
These plans are designed to the following standards
Florida Building Code 2020
)
2020 TCC
Wind :Speed -160 MPH ,V ult.
Exposure „C„
Structure is enclosed
Internal Pressure Coefficient +/,,18
Building Category 11 Importance Factor'1.0 Design Pressures - t6t) Valt- Exposure ••("" meiin r(iorheight <30'
Ante sheathing to he 19/32" CD\ plywood with 2 '/," c 0.131, or 3" x 0.12.0 ring 'silank nails 4:' un center on edges and in Geld
Cable Roar> 21) to 27 degrees
I.2c 11) +28.8 -55.11
1.2e 20 +25.0 -55.0
1-2e 50 +20.9 -47.0
1.2e 100 +15.9 -403
2n.2r.3e 1.1) +28.8 -88.0
2i"r.3e .20 +25.0 -77.0
2n,2r,3e 50 +20.9 -62.6
2n,2r�e 100 +15.9 -51.8
3r 10 +mg 404:7
3r "20 +25.0 ,88.11
3r so +20.9 -65.6
3r 101) +15.9 -65.11
Ilip Root> 20 to 27 degrees
1 10 23.3
-41.$
1 21) 20.1
-37 :.
1 50 15.9
_m.?'
1 101) 17.7
=2.5.9
2e,2r,3 10 23.3
41.8.
2n,2r.3e 20 20.1
-51:5
2n,2r,3e 50 15.9
43A
2n,2r,3e 100 12.7
-31.2
Walls
4 10 31.2
-33.8
4 20 29.8
-32.4
4 50 27.9
-30.6
4 100 26.5
-29.2
4 500 23.3
-259
5 10 31.2
41.8`
5 20 29.8
5
-38.9
GENERAL NOTES
1) THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS
AT JOB SITES, PLANS, SPECIFICATIONS, ETC.
2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY ARCHITECT/
ENGINEER AS CONTRUCTION PROGRESSES.
3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER: SCALED DIMENSIONS.
4) ALL SONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE 2020 (7th EDITION), FBC 2020
(7TH EDITION) RESIDENTIAL, FBC 2020 (7th EDITION) PLUMBING, FBC 2020 (7th EDITION) MECHANICAL
FBC 2020 (7th EDITION) ENERGY CONSERVATION, AND THE NEC (NFPA 70) 2020.
5) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY TERMITE INFESTATION
AREA PER FRC301
ENERGY CONSERVATION NOTES
1) RESIDENCE SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING CODE 2020 (7th EDITION) ENERGY
CONSERVATION RESIDENTIAL.
2) ATTIC ACCESS DOORS OR HATCHES FROM CONDITIONED SPACES TO UNCONDITIONED SPACES SHALL
BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVELANT TO THE INSULATION ON THE SURROUNDING
SURFACES. A WOOD FRAMED OR EQUIVELANT BAFFLE OR RETAINER OS REQUIRED TO BE PROVIDED WHEN
LOOSE FILL IS INSTALLED TO PREVENT LOOSE FILL FROM SPILLING INTO THE LIVING SPACE
3) THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTEOTO LIMITAIR LEAKAGE IN ACCORDANCE WITH
WITH THE REQUIREMENTS R402.4.1 THROUGH R402.4.4
4) WINDOWS, SKYLIGHTS, AND SLIDING GLASS DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NO MORE
THAN 0.3 CFM PER SQUARE FOOT AND SWINGING DOORS NO MORE THAN 0.5 CFM PER SQUARE FOOT AND
MUST BE TESTED, LISTED, AND LABELED IN ACCORDANCE WITH R402.4.3
5) CONTRACTOR SHALL PROVIDE ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD IN ACCORDANCE WITH
FBC 2017 (6th EDITION) ENERGY CONSERVATION R401.3
ADDITIONAL NOTES
1) INTERIOR TO BE DRYWALL FINISHED.
2) ALL INTERIOR GYPSUM BOARD TO BE MIN 1/2" THICK WITH 13 (;UAGE, 1-3/8" LONG, 19/64" HEAD; 0.098" DIA.,
1-1/4" LONG, ANNULAR -RINGED; 5d COOLER NAIL, 0.086" DIA., 1-5/8" LONG, 5/64" HEAD OR GYPSUM BOARD
NAIL 0.086" DIA. 1-5/8" LONG, 9/32" HEAD SPACED AT 7" O.C. FOR NAILS OR 12" O.C. FOR SCREWS.
3) WALLS AT SHOWERS TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN
COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR C 1278 ANb INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS AS BRACKETS FOR WALL TILE IN TUB AND SHOWER AREAS AND
WALL PANELS IN SHOWER AREAS (PER FRC 702.4.1 AND FRC 702.4.2).
4) WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450.
5) WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD CLASSIFICATION OF NOT GREATER THAN 200.
6) AL LEXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL HAVE A CRITICAL RADIANT
FLUX NOT LESS THAN 0.12 WATTS PER SQUARE CENTIMETER. EXPOSED FOAM PLASTIC INSULATION
MATERIALS EXPOSED TO THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL COMPLY
WITH SECTION FRC 316
7) PER FRC 702.2.1 ALL GYPSUM BOARD MATERIALS AND ACCESr'ORIES SHALL COFORM TO ASTM C 36,
C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C 1047, C 1177, C1178, C 1278, C 1395, C 1396, OR C 1658
AND SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF FRC AND ADHESIVES FOR THE
INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557
8) INSULATION ON MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE
MEMBRANES INSTALLED WITHIN FLOOR -CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL
ASSEMBLIES, CRAWLL SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 450
WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723
PRODUCT-
FL OR NOA
"EXp. DATE MODEL
" MANUF.
GLASS7YPE
- ATTACHMENT METHOD
REQUIRED Rp P.S.F
t
PROVIDED D.P. P.Sf
_ ( j
SINGLE HUNG (SH)
20.0401.11
8/23/2023 SH-7700
PGT
IMPACT
1/4." X 2 3/4" TAPCON (TRIMFIT) FILL EACH
HOLE TO 11/4" EMBEDMENT
1/4" X 23/4" TAPCON (TRIMFIT) FILL EACH
+31.2/-33.8
+651-80'
ALUMINUM FIXED
20-0401.10
2/19/2024
PW7720A'
PGT
IMPACT
GLASS
HOLE TO11/4"EMBEDMENT
1/4" X 1-3/8" MIN. EMBED. TAPCONS
+31.2/-33.9
+80/-80
MULLIONS
20-0406.03
5/26/2021
7700A
PGT
(4) PER CLIP
1-1/4" x 1-3/4" MIN. EMBED TAPCONS, @ 5"
SGD
20-0429.09
,2/17/2025
SGD 770
PGT
IMPACT
FROM CORNERS Fie 13" O.0 PEREMETER
+27.9 / -30.6
-
+60 / -60
5/16" x 1-5/8" MIN. EMBED. LAG SCREWS ONE
R (
OVERHEAD GARAGE
16546:4
12J31/2026
73W6
CLOPAY
IMPACT
DOOR
PER BRACKET)
#10 x 2 1/2" PFH WOOD SCREW (1.15 IN.) MIN.
+34.2 / -43:7
+54 / -63
V-8" SOLID DOOR
W/SIDELITES
20468.2
12/.31/2021
SMOOTH STAR
THERMATRU
IMPACT
EMBEDMENT, 3" & 6" FROM CORNERS 14" MAX
+31.2/-33.9
+50/-50
O.C. 3" & 7" FROM IAMB
# 10 x 2 1/2" PFH WOOD SCREW (1.15 IN.) MIN.
6'4' SOLID DOOR
20468,1
12/31/2021
SMOOTH STAR
THERMA TRU
IMPACT
EMBEDMENT.6" PROM CORNERS 14" MAX O.0
+31.2 J -33.10
+67 /-67
EACH SIDE OF DOOR
# 10 x 2 1/2" PFH WOOD SCREW (1.15 IN.) MIN.
ti'-8" 1 LITE
20468.7
12/31/2021
SMOOTH STAR
THERMA TRU
IMPACT
EMBEDMENT 6" PROM CORNERS 14" MAX O.0
EACH SIDE OF DOOR
#10 x 2 1/2" PFH WOOD SCREW (1.15 IN.) MIN.
6'-8" DOUBLE DOOR
1 LITE
20468.9
12/31/2021
SMOOTH STAR
THERMA TRU
IMPACT
EMBEDMENT 6" PROM CORNERS 14" MAX O.C.
1-38.8 /-42.2
+SO /-50
3" & 7" FROM AS'rRAGALTOP AND BOTTOM
SELF-ADHEARED ONTO BASE SHEET WITH
UNDERLAYMENT
17-0614.22
9/13/2021
POLYSTICK
POLYGLASS
MINIMUM 3" SIDE LAP AND 6" END LAP;
#10 PANCAKE HEAD SCREW x 1" AT
1" STANDING
ROOF
27499.1
12/6/2026
SEAM
DYNAMIC
6" O.C. wJ3/16" HENETRATION
THROUGH BOTTOM SUPPORT
LAMES
LAP SIDING
13198.2
12/31/2023
HARDIEPLANK
HARDIE
11/4 AEROSMITH NAILS TO BLOCK @ 12" O.0
BUILDING
PRODUCTS
center on edges and in field
Note: Sheathing to be
19/32" CD
plywood with 2 %:" x 0.131, or 3"
x 0.120 ring shank
nails 4" on
51
27.9
-35.3
5
iou
26.5
32.4
5
500
23.3
-2.5.9