HomeMy WebLinkAboutAPPROVED Capano letter-esigned M.A. CORSON & ASSOCIATES, Inc. ARCHITECTURE * STRUCTURAL DESIGN 412 Colorado Ave., Stuart, Fl. 34994 (772) 223-8227 * Lic. #AR91665 To: St. Lucie County - Building & Code Regulation Division Date: June 22, 2021 Re: Dorea Capano 9490 S. Ocean Dr. Unit A - 615 (middle) Jensen Beach, FL 34957 It is acceptable to replace existing window and door openings for the address listed above as follows: 1) S.H. - The PGT systems Series "SH 5500A" L.M.I. the pvc single hung window has a Florida number NOA-#20-0401.03. It has a +65 /-70 design pressure and has a L.M.I. & S.M.I. "D" approval and HVHZ. 2) D.H.- The PGT Window Systems "SH 5560" Impact PVC double hung window L.M.I. has a Miami Dade NOA #20-0401.06 . It has a +70 /-110 design pressure and has a small & large missile "D" approval and HVHZ. 3) P.W.- The PGT Window Systems "PW 5520A" Impact PVC picture window has a Miami Dade NOA #20-0401.16. It has a +80 /-110.0 design pressure and has a large missile "D" approval and HVHZ . 4) S.G.D. - The International Impact Building Products Series " Titan 90 " aluminum sliding glass door with reinforcements has a Miami Dade NOA 20-1202.12. It has a +90 / -90 design pressure. It has a small and large missile "D" approval HVHZ. 5) MULLION TUBE - The PGT Window Systems - Series "PGT" Clipped Extruded Aluminum Tube Mullion - L.M.I. has a Florida number NOA #20-0406.03. It has a +170 /- 170 design pressure and has a small missile "D" approval and HVHZ . The worst case scenario building design pressures of address listed above in Zone 4 is +58.7 / - 63.7 and Zone 5 is +58.7 / -78.5. The building has a type II classification and exposure category "D" for the 7th Edition of the FBC (2020). SCOPE OF WORK: New single hung,double hung, picture window, sliding glass door, & mullion bar. DESIGN PARAMETERS AND ASSUMPTIONS USED: 1. DESIGN CODE: Florida Building Code Seventh Edition (2020) 2. Structure Designed: Enclosed 3. Risk Category: II Exposure Category: D 4. Design Wind Velocity 170 mph Nominal Wind Speed 132 mph End Zone Width: 4 ft 5. Mean Roof Height 150 ft Roof Pitch: 0:12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: Zone 4: +58.7 / -63.7 P.S.F. & Zone 5: +58.7 / -78.5 P.S.F. Worst case scenario has been calculated. 7. Design Loads: Floor: N/A Roof/Dead: N/A Roof/Live: N/A Balcony: N/A Dock: N/A Deck: N/A Stairs: N/A Fence: N/A Railings: N/A 8. Were Shear Walls Considered For Structure? N/A Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? N/A 10. Design Soil Bearing Pressure: N/A Soil Test Reports Submitted? N/A Thank you for your time and consideration. If you have any questions please call. Respectfully, Mark A Corson Mark A. Corson A.I.A., NCARB President