Loading...
HomeMy WebLinkAboutBuilding Plansds-off GENERAL NOTES: 1. ANCHORING PLANS ARE TO BE USED IN CONJUNCTION WITH BUILDING PLANS, SUBMITTED SEPARATELY. 2. DESIGN LOADS ARE IN ACCORDANCE WITH THE 2020 FLORIDA BUILDING CODE. 3. WIND LOADS ARE BASED ON THE FOLLOWING: ULTIMATE DESIGN WIND SPEEDS: 2020 FBC FIGURE 1609.3(4) Vult = 120 MPH Vult = 140 MPH Vult = 160 MPH RISK CATEGORY I EXPOSURE CATEGORY C INTERNAL PRESSURE COEFFICIENT: GCpI = i0.18 4. THE MINIMUM ANCHORAGE SHALL BE AN ANCHOR AT EACH CORNER OF THE BUILDING. LOCATE THE ANCHOR WITHIN 12 INCHES FROM THE CORNER. REFER TO ANCHOR SCHEDULE FOR ADDITIONAL ANCHORS THAT MAY BE REQUIRED. ANY ADDITIONAL ANCHORS BETWEEN THE CORNERS SHALL BE SPACED EQUALLY. 5. WEATHER KING IS NOT RESPONSIBLE FOR THE PREPARATION OF THE PROPOSED SITE OR DETERMINATION OF THE SITE'S SUITABILITY TO SUPPORT THE PROPOSED STRUCTURE. IT IS THE PROPERTY OWNER'S RESPONSIBILITY TO DETERMINE IF SITE CONDITIONS ARE SUITABLE TO SUPPORT THE STRUCTURE. 6. TIE -DOWNS AND ANCHORS ARE TO BE SUPPLIED AND INSTALLED BY THE PROPERTY OWNER. WEATHER KING IS NOT RESPONSIBLE FOR ANCHORING THE BUILDING. 7. THE SCHEDULES INDICATE THE RECOMMENDED NUMBER AND TYPE OF BUILDING ANCHORS TO BE INSTALLED BY THE PROPERTY OWNER ALONG EACH SIDE OF THE BUILDING. GROUND ANCHORS SHALL BE RATED FOR SOIL CLASSIFICATION 4a. IT IS THE PROPERTY OWNER'S RESPONSIBILITY TO VERIFY THE SOIL TYPE FOR THE SITE WHERE THE BUILDING IS TO BE PLACED. 8. GROUND ANCHORS DESIGNED FOR SOIL CLASS 4a OR BETTER. RECEIVED JUN 16.2021 Permitting Department St. Lucie County REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY E000 SOIL CLASS 4a: CONSISTS OF LOOSE TO MEDIUM DENSE SANDS, FIRM TO STIFF CLAYS AND SILTS, ALLUVIAL FILL. BLOW COUNT, PER ASTM D1586, OF 18 TO 23, AND A READING ON A TORQUE PROBE OF 276 TO 350 INCH POUNDS. THE MINIMUM ANCHOR LENGTH FOR SOIL CLASS 4a SHALL BE 48 INCHES. PN -WEA7 ` - �R ING P.O. BOX 108 PARIS, TN 38242 MASTER ANCHORING PLANS��FLORIDA��FBC 2020 PROJECT No: SHEET NUMBER DATE: 12-31-2020 r _ t ~ , `• r _ � DRAWN BY: KLN SmOm iWeatherK.-nCHECKED BY: KLN - /�• PORTPORTA OLEBUILDINGS REVISION: SCALE: NONE SCHEDULES FOR EYE ANCHORS BOLTED TO BUILDING UPLIFT ANCHORAGE SCHEDULE FOR WIND UP TO 120 MPH BLDG NUMBER OF ANCHORS EACH SIDE OF BUILDING WIDTH 10'-0" 12'-0- 14'-0" 16'-0" 18'-0" 20'-0" 22'-0" 24'-0" 26'-0" 28'-0" 30,-0" 32'-0" 8'-0" 2 3 3 4 4 5 - - - - - - 10'-0" 2 3 3 3 4 4 5 5 5 6 6 - 11'-2" - 2 3 3 3 3 3 4 4 4 4 5 UPLIFT ANCHORAGE SCHEDULE FOR WIND 121 TO 140 MPH BLDG NUMBER OF ANCHORS EACH SIDE OF BUILDING WIDTH 10'-0" 12'-0' 14'-0" 16'-0" 18'-0" 20'-0" 22'-0" 24'.0" 26'-0" 28'-0" 30'-0" 32'-0" 8'-0" 4 4 5 5 6 6 - - - - - - 10'-0" 3 4 4 4 5 5 6 6 6 7 7 - 11'-2" 1 - 3 4 4 5 5 5 5 6 6 7 7 UPLIFT ANCHORAGE SCHEDULE FOR WIND 141 TO 160 MPH BLDG NUMBER OF ANCHORS EACH SIDE OF BUILDING WIDTH 10'-0" 12'-0" 14'-0" 16'-0' 18'-0" 20'-0" 22'-0" 24'-0" 26'-0" 28'-0" 30'-0" 32'-0" 8'-0" 5 5 6 6 6 7 - - - - - - 10'-0" 4 5 5 5 6 6 7 7 8 9 9 - 11'-2" - 4 5 5 6 6 7 7 1 8 8 8 9 MASTER ANCHORING PLANS--FLORIDA--FBC 2020 h K' V� vu e r PORTABLE B(J(LDIMG PROJECT NO: DATE: 12-31-2020 DRAWN BY: KLN CHECKED BY: _ KLN REVISION: SHEET NUMBER SCALE: _' ATTACH ANCHOR TO RIM BOARD W/ Y2" 0 BOLT W/ WASHER (GALV.) 11 REFER TO SCHEDULE I I FOR ANCHOR INFO. u PROVIDE 2x TRTD BLOCKING AT BOLT LOCATION. PLACE W/ GRAIN RUNNING VERTICALLY. ATTACH TO RIM JOIST W/ (6) 10d NAILS MIN. REFER TO SCHEDULE I I FOR ANCHOR INFO. u FINISH GRADE 1-BOLTED EYE ANCHOR DETAIL 20 GA. x 1Y4" WIDE GALVANIZED STRAP EXTENDED OVER SKIDS. ATTACH TO ANCHOR W/ SLOTTED BOLT PER MANUF. SPECS. CONCRETE SLAB TIE DOWN ANCHOR. REFER TO SCHEDULE FOR SPACING (TYP) ATTACH ANCHOR TO L CONCRETE SLAB ON CONCRETE W/ %" DIA. GRADE BY OTHERS. EXPANSION BOLT W/ 4" MIN 3" EMBEDMENT (TYP) 3-TYPICAL CONCRETE ANCHOR W/ STRAP DETAIL OUTSIDE SKID (TYP) 0 z LQO FINISH p U GRADE w J w rnwW 20 GA. x lY4' WIDE GALVANIZED STRAP EXTENDED OVER SKIDS. ATTACH TO ANCHOR W/ SLOTTED BOLT PER MANUF. SPECS. FINISH OUTSIDE J GRADE SKID (TYP) 2-TYPICAL ANCHOR W/ STRAP DETAIL RECOMMENDED GROUND ANCHOR SCHEDULE SOIL CLASS ANCHOR DESCRIPTION 4a V O ROD x 48" LONG w/ (1) 6" HELIX %4' O ROD x 48" LONG w/ (1) 6" HELIX 3/4" O ROD x 48" LONG w/ (2) 4" HELIX EYE ANCHOR - e" O ROD x 48" LONG w/ (1) 6" HELIX EYE ANCHOR - 3/4" 0 ROD x 48" LONG w/ (1) 6" HELIX NOTE: REFER TO NOTE 8 ON SHEET S-0 FOR SOIL CLASS DESCRIPTION. MASTER ANCHORING PLANS��FLORIDA--FBC 2020 PROJECT NO: SHEET NUMBER DATE: 12-31-2020 DRAWN BY: KLN Weat hiur Ki I I CHECKED BY: KLN S=2.0=AP ■■ REVISION: "= j- tY-y 1 PORTABLE� �1��.� �� SCALE: 1 -1 0 19 SCHEDULES FOR GROUND ANCHORS W/ STRAPS UPLIFT ANCHORAGE SCHEDULE FOR WIND UP TO 120 MPH BLDG NUMBER OF ANCHORS EACH SIDE OF BUILDING 10'-0" 12'-0" 14'-0" 16'-0" 18'.0" 20'-0" 22'-0" 24'-0" 26'-0" 28'-0" 30'-0" 32'-0" m 2 2 3 3 3 4 - - - - -2 2 2 3 3 3 3 4 4 4 4 - - 2 2 3 3 3 3 3 3 3 3 4 UPLIFT ANCHORAGE SCHEDULE FOR WIND 121 TO 140 MPH BLDG NUMBER OF ANCHORS EACH SIDE OF BUILDING WIDTH 10'-0" 12'-0" 14'-0" 16'-0" 18'-0" 20'-0" 22'-0" 24'-0" 26'-0" 28'-0" 30'-0" 32'-0" 8'-0" 3 3 4 4 4 5 - - - - - - 10'-01, 3 3 3 3 4 4 4 4 5 5 5 - 11'-2" - 2 3 3 4 4 4 4 5 5 5 •5 UPLIFT ANCHORAGE SCHEDULE FOR WIND 141 TO 160 MPH BLDG NUMBER OF ANCHORS EACH SIDE OF BUILDING 10'-0" 12'-0" 14'-0" 16'-0" 18'-0" 20'-0" 22'-0" 24'-0" 26'-0" 28'-0" 30'-0" 32'-0" I 4 4 5 5 5 5 - - - - -4 4 4 4 5 5 5 6 6 7 7 - - 4 4 4 5 5 5 5 6 6 7 7 MASTER ANCHORING PLANS f PROJECT NO: DATE: 12-31-2020 eather. DRAWN BY: KLN CHECKED BY: W KLN PORTABLE BUILDINGS REVISION: L --FLORIDA--FBC 2020 SHEET NUMBER SmI.OmAP SCALE: ATTACH ANCHOR TO RIM BOARD WI ' 0 BOLT W/ WASHER (GALV.) N REFER TO SCHEDULE I I FOR ANCHOR INFO. u PROVIDE 2x TRTD BLOCKING AT BOLT LOCATION. PLACE W/ GRAIN RUNNING VERTICALLY. ATTACH TO RIM JOIST W/ (6) 10d NAILS MIN. FINISH GRADE a-. d 4'. .e OPTIONAL 16"x16"x4" SOLID MASONRY BLOCK PAD. REFER TO SCHEDULE FOR QUANTITY AND SPACING. 1-BOLTED EYE ANCHOR DETAIL W/ OPTIONAL BLOCK PAD OPTIONAL BLOCK PAD SCHEDULE BLDG NUMBER OF PADS BENEATH EACH SKID WIDTH 10'-0" 1 12'-0" 14'-0" 16'-0" 18'-0" 20'-0" 22'-0" 24'-0" 26'-0" 28'-0" 30'-0" 32'4" 8'-0" 2 3 3 3 - - - - - - - - 10'-0" 2 2 2 3 3 3 - - - - - - 11'-2" - - - 3 3 3 3 3 3 3 3 4 NOTES: 1. BLOCK PADS ARE OPTIONAL. 2. BLOCK SIZES SHOWN ARE NOMINAL. PADS MAY CONSIST OF EITHER A SINGLE 16x16 BLOCK OR (2) 16x8 BLOCKS. 3. BLOCK PADS SHALL BE PLACED WITHIN 12 INCHES OF EACH BUILDING CORNER. ADDITIONAL PADS, AS REQUIRED, SHALL BE SPACED EQUALLY. 20 GA. x %" WIDE GALVANIZED STRAP EXTENDED OVER SKIDS. ATTACH TO ANCHOR W/ SLOTTED OUTSIDE BOLT PER MANUF. SPECS. SKID (TYP) —� REFER TO SCHEDULE o °. ^ a I I FOR ANCHOR INFO. e e u OPTIONAL 16"x16"x4" SOLID MASONRY BLOCK PAD. REFER TO SCHEDULE FOR QUANTITY AND SPACING. (TYP) 2-TYPICAL ANCHOR W/ STRAP DETAIL W/ OPTIONAL BLOCK PAD MASTER ANCHORING PLANS--FLORIDA--FBC 2020 FINISH GRADE PROJECT NO: SHEET NUMBER DATE: 12-31-2020 ' DRAWN BY: KLN Sm2.1, �AP e i ther KinCHECKED BY: KLN P O TAL U I L N � REVISION: SCALE: 1"=1'-0