Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL in fit c G• c ® 0 � 9 a 0 � _ - BCIS.Home Log In �� User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us ' BCIS Site Map' Links i 'Search Florida -. r .".� Product Approval 'USER:Public UserN�:,�rw� Sy �. Product Approval Menu>Product or Aa lication Search>Application List>Application Detail , 1 I " ` FL# FL208767112 Application Type Revision Code Version 2020— Application Status Approved, y *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC.and/or the Commission If necessary. Comments Archived Product Manufacturer Dupont Address/Phone/Email 5401 Jefferson Davis Highway Richmond,VA 23234 (812)212-4429 melista.s.grant@dupont.com Authorized Signature Melissa Grant melissa.s.grant@dupont.com Technical Representative Melissa Grant Address/Phone/Email P.O.Box 103 202 E.Washington Street Morris,IL 60450 (812)212-4429 melissa.s.grant@dupont.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity Intertek Testing Services NA,Inc. Quality Assurance Entity Intertek Testing Services NA,Inc.-QA Entity Quality Assurance Contract Expiration Date 12/31/2023 Validated By Intertek Testing Services NA,Inc. Certificate of Independence Referenced Standard and Year(of Standard) Standard Year ASTM D226 2009 Equivalence of Product.Standards Certified By Sections from the Code Product Approval Method Method 1 Option C Date Submitted 01/27/2021 Date Validated 01/27/2021 Date Pending FBC Approval Date Approved 01/29/2021 Summary of Products Number or Name Description 20876.1 Dupont Protec Underlayment 120,160,200 t `. j F =�•_ j ') Limits of Use.' i # Installation Instructions °Approved for�use in HVHZ:Yesf FL20876 R2 II K29385 Tyvek Protec Install Guide.pdf a ;Approved-for use outsidd:HVHZ:Yes Verified By:Intertek Testing Services NA,Inc: sIm-act Reslistant:-N/A Created by Independent Third Party: Design Pressure:N%A Evaluation Reports Other: FL20876 R2 AE 2021-01-26 CCRR-1062.pdf 20876.2 Dupont Tyvek Underlayment Roof Protector Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL20876 R2 II SC00501-Tyvek Roof Protector Brochure.pdf Approved for use outside HVHZ:Yes Verified By:Intertek Testing Services NA,Inc. Impact Resistant:N/A Created by Independent Third Party: Design Pressure:N/A Evaluation Reports Other: FL20876 R2 AE 2021-01-26 CCRR-1087.pdf Back Nett Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1874 The State of Florida is an AA/EEO employer-Copytaht 2007-2013 State of Florida..::Privacy Statement::Accessibility Statement;:Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850:487.1395.'Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,FS.,please click bgre. Product Approval Accepts: © eChecV M Credit Card Safe 40UPONTk Installation Information Tyvek. DuPontTmTyvek®R ProtecTM Roofing Underlayments Installation Guidelines SYSTEM OVERVIEW Installation Guidelines Acceptable For Use With Tyvek`Protec"meets or exceeds the following code • DuPont'Tyvek'Protec"120 criteria and test protocols: DuPont"'Protec"'160 -AC188(Intertek CCRR 1062) DuPont'Tyvek'Protec'200 -ASTM D226 types I&II Specifications -ASTM E108 • Tyvek'Protec'is available in 10 square rolls: -CAN/CSA A123.3 48"x25071.2m x 76.2m(92.9m2), -CAN/CSA A2201 and 2 square rollsr48"x5071.2m x 15.2m(18.5 W) Precautions and Safety • Tyvek'Protec'is for use on roofs with slopes 22:12. . Apply Tyvek'Protec"taut and wrinkle-free. • Tyvek'Protec"'must be covered with the final roof Do not stretch. cladding within: • Do not apply Tyvek.Protec"'over wet or frost-covered 3-months with Tyvek'Protec"120 roof sheathing. 6-months with Tyvek'Protec"16.0.or Tyvek* • Caution should be taken when walking on Tyvek' Protec"200 Protec"'until it has been fastened according to Tyvek Protec"should not be considered a final roofing instructions. system/primary water barrier.Tyvek"Protec"'is a • Caution should_be taken when walking on Tyvek' secondary layer applied over sheathing,under a primary Protec"when.it is wet or f rost-covered. roofing system as specified for the following: • Use fall protection when working on roof.Refer to -Tyvek'Protec"'120-asphalt shingles,metal or cedar OSHA safety regulations 29 CFR1926 subpart M. roof cladding. Consult your local DuPont"Tyvek°Specialist for -TyvekP Protec"160-asphalt shingles,tile,metal, additional information. cedar,or slate roof cladding Preparation -Tyvek`Protec'200-asphalt shingles,tile,metal, • Apply Tyvek'Protec"over a dry,smooth,clean and defect-free roof deck.Tyvek'Protec"cannot be installed cedar,or slate roof cladding over existing roof cladding. Building Code Compliance • Tyvek'Protec"is a vapor barrier.Ensure that the space • Consult local building code and roof cladding beneath the roof sheathing is properly ventilated before manufacturer for use of underlayment installing to avoid condensation problems. • Consult local building code and roof cladding manufacturer for underlayment edge and end overlap and fastening requirements that may differ from Tyvek' Protec"instructions.Follow the more restrictive requirements. • Where required by local building code,apply selfadhering waterproof underlayment as required by code according to manufacturer's instructions and Tyvek' Protec'for successive courses. • Tyvek`Protec"provides protection against leaks under all types of roof coverings identified by ICC-ES AC188. INSTALLATION 1. Lay courses of DuPont'Tyvek'Protec"horizontally in"shingle 5.Apply Tyvek'Protec"with two layers on roofs with style"fashion following the lap lines provided in 4" slopes between 2:12 and up to 4:12.Begin with a 26" course overlaps and 6"end laps beginning along the eave undercourse strip parallel to the eave edge,and then edge.Offset end laps in successive courses by 6 feet. cover with a full width sheet.Overlap successive sheets 2. When attaching DuPont"Tyvek'Protec"to the roof by 26". sheathing: 6.Install Tyvek'Protec'over drip edges along eave edge When used under tile,slate,cedar and metal roof and under drip edges along rake edges. claddings,1"diameter(min)metal or plastic Lap Tyvek'Protec"8"(min)onto watts. (ring shank or smooth shank)cap-nails or 7 Line roof valleys with a sheet of Tyvek'Protec"prior to cap-staples are required. -When used under asphalt or synthetic shingles, installing horizontal courses of Tyvek*Protec".Lap the 1"diameter(min)metal or plastic cap-nails or ends of horizontal tTyvek°Protec"courses over the y capstaples are recommended.Un-capped staples or valley sheet by 6". standard roofing nails may be used if shingles are 8.At ridges and hips where ridge vents will not be installed within 36 hours(unless rain or high winds applied,cross-tap Tyvek'Protec"from one roof plane are expected).Use of un-capped fasteners may result onto the other by 6".For additional weather in a risk of blow off or leakage around the fastener protection,apply a 24"wide sheet of Tyvek'Protec" penetrations during a wind or rain event. across hips and ridges. - All anchoring must be performed flush to the roof and 90 degrees to the roof deck. Warranty 3. Install fasteners 12"on center(o.c)along course and end Tyvek'Protec"is covered by a limited product over-laps and a single row 24"on center along the middle replacement warranty: Line of the field.Use the printed pattern as a guide. • Tyvek'Protec"120:30 years 4.In high wind zones(at or above 100 mph per IRC - Tyvek'Protec"160:40 years R301.2),fasteners must be installed at all printed • Tyvek'Protec"200:50 years locations on the Tyvek*Protec".It must be fastened using corrosion-resistant metal or plastic cap nails with Warranty is offered by DuPont for builders,general a head diameter of at least 1"and a thickness of at least contractors,or professional installers.This is not a 32-gauge sheet metal.The cap-nail shank shall be a consumer warranty.To obtain a copy of the warranty please minimum of 12 gauge(0.105 inches)with a length to visit www.tyvek.com/protec or call1-800-448-9835. penetrate through the roof sheathing of a minimum of %inch into the roof sheathing. 40UPONT! Tyvek. For more information about DuPont-Tyv ek'Protec", Pr®tee- please calll-800-448-9835 or ROOFING UNDERLAYMENTS visit us at www.tyvek.com/protec NOTICE:No freedom from any patent owned by DuPont or others is to be inferred.Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer's use and for ensuring that Customer's workplace and disposal practices are in compliance with applicable laws and other government enactments.The product shown in this literature may not be available for sale and/or available in all geographies where DuPont is represented. The claims made may not have been approved for use in all countries or regions.DuPont assumes no obligation or liability for the information in this document References to`DuPont'or the-Company" mean the DuPont legal entity setting the products to Customer unless otherwise expressly noted.NO EXPRESS WARRANTIES ARE GIVEN EXCEPT FOR ANY APPLICABLE WRITTEN WARRANTIES SPECIFICALLY PROVIDED BY DUPONT.ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.The buyer assumes all risks as to the use of the material.Buyers exclusive remedy or any claim(including without tinikations,negligence,strict liability,or tort)shall be limited to the refund of the purchase price Of the material.Failure to strictly adhere to any recommended procedures shall release DuPont Specialty Products USA,LLC or its affiliates,of all liability with respect to the materials or the use thereof. The information herein is not intended for use by non-professional designers,applicators or other persons who do not purchase or utilize this product in the normal course of.their business. CAUTION:When cured,these products are combustible and will burn if exposed to open Rome or sparks from high-energy saurces Do not expose to temperatures above 240°F(116°C).For more informatiam consult (Material)'Safety Data Sheet((MISDS).call DuPont at 1.866-S83-BLUE(2583)or contact your local building inspector.In an emergencg call 1-989-636.4400 in the US or 1-519-339-3711 in Canada.The blowing agent contained within this product can exhibit vapor Flame limits under the right conditions.If specific operating conditions are such that concentrations of the blowing agent above the lmuer flammable limit can accumulate In areas with high relative humidity and in the presence of high-energy electrical discharges or other Ignition sources,additional measures such as increased.ventilation or ceded electrical equipment(class One,division hva) may be warranted.DO NOT SMOKE DURING USE.DO NOT USE NEAR ANYOPEN FLAME OR ELECTRICAL SOURCE.OUTDOOR USE ONLY.INDOOR USE INCREASES LIKELIHOOD OF IGNITABLE CONDITIONS.INSTASTIK Quik Set Commercial Roofing Adhesive contains isocyanate and a blowing agent Read the label and(Material)Safety Data Sheet fiMISDS)carefully before use Wear gloves,and goggles or safety glasses Provide_adequate ventilation or wear proper respiratory protection.Contents under pressure.For outside use only. - DuPont`the DuPont Oval Logo,and all trademarks and service marks denoted with t1,"or z are owned by affiliates of DuPont de Nemours,Inc unless otherwise noted©2020 DuPont 43-0100784-ent4A-0220 CDP intertek Code Compliance Research Report Total Quality.Assured. CCRR-1062 Issue Date:05-25-2016 Revision Date:01-26-2021 Renewal Date:01-31-2022 DIVISION:07 00 00—THERMAL AND MOISTURE PROTECTION Dupont" Tyvek® Protec'"_160 is a mechanically attached Section:07 30 05—Roofing Felt and Underlayment synthetic underlayment comprised of an embossed non- woven top scrim and a woven.bottom scrim with a polymeric REPORT HOLDER: laminated facer. The underlayment has an overall weight of DuPont de Nemours,Inc. 3.27 pounds per 100 square feet, and it is available in rolls 1501 Larkin Center Drive 48 inches wide by 250 feet long. Midland,MI 48674 (989)638-4319 Dupont— Tyvek® Protec'" 200 is a mechanically attached www.dupont.com/building synthetic underlayment comprised of an embossed non- woven top scrim and a woven bottom scrim with a polymeric REPORT SUBJECT: laminated facer.The underlayment has an overall weight of Dupont`" Tyvek® Protee- 120, 160, and 200 Roofing 3.58 pounds per 100 square feet, and it is available in rolls Underlayments 48 inches wide by 250 feet long. 1.0 SCOPE OF EVALUATION 4.0 INSTALLATION This Research Report addresses compliance with the following 4.1 General: Codes: '2018,2015,and 2012 International Building Code"(IBC) Installation of the underlayments must comply with the .2018,2015,and 2012 International Residential Code®(IRC) applicable Code, this report, and the report holder's 2020 Florida Building Code(FBC)—See Section 8.1 published installation instructions. 2.0 USES The underlayments must be installed in accordance with the subsections of IBC Section 1507 and IRC Section R905 Dupont"" Tyvek® Protec'" 120, 160,.and 200 underlayments applicable 'to the roof covering being installed. The are used in the field of the roof-as an alternative to the ASTM underlayments must be laid with the print side up,with laps as D226, Type I and Type II, roof underlayments specified in required by the applicable Code, evaluation report, or Chapter 15 of the IBC and Chapter 9 of the IRC. manufacturer's instructions,,whichever is more restrictive. The underlayments may be used in areas of the roof required The roof covering may be installed.immediately following the by IBC Section 1507 or IRC Section R905 to have an ice barrier underlayment application and,the underlayment must be roof underlayment,when installed as noted in Section 4.2. covered within the time designated in the report holder's published installation instructions. The underlayments may be used as components of classified assemblies when installed as described in this report. 4.2 Ice Barrier: The underlayments have been evaluated for the properties as In areas of the roof required by IBC Section 1507 or IRC listed in Table 1. Section R905 to have an ice barrier,two layers of Dupont'" Tyvek° Protec' 120, 160, or 200 underlayment, solidly 3.0 DESCRIPTION cemented together with a low solvent:based roofing cement, complying with ASTM D4586 Type 1(asbestos free), may be Dupont'" Tyvek® Protec'" 120 is a mechanically_attached used provided the ice barrier extends up the roof a minimum synthetic underlayment comprised of an embossed non- distance of 24 inches inside the interior wall line of the woven top scrim and a woven bottom scrim with a polymeric building. The underlayment installed in the field of the roof laminated facer. The underlayment has an overall weight of must overlap the ice barrier. 2.25 pounds per 100 square feet, and it is available in rolls 48 inches wide by 250 feet long. OE1� 545 E.Algonquin Road•Arlington Heights,*Illinois 60005 intert'ek.com/buildine Intertek PCA-101 Version:21 December 2017 5FT-CUR-OP-40b ton . Code Compliance Research Report CCRR-1062 Page 2 of 3 4.3 Fire Classification: 7.0 IDENTIFICATION The underlayments may be used as a component of a The Dupont'"" Tyvek® Protec"" 120,. 160 and 200 classified roof assembly when specifically recognized as such underlayments are imprinted with the report holder's name, in a listing approved by the Code official. The underlayments the Intertek Mark,and the Code Compliance Research Report may also be used as an alternative to the underlayments number(CCRR-1062). Each roll of the product is also labeled specified in the Code for roof coverings permitted under the with installation instructions,roll dimensions and weight. Exceptions to IBC Section 1505.2 and IRC Section R902.1 and coxwu+ce CODE may be used where non-classified roofing is permitted in IBC a Section 1505.5. 5.0 CONDITIONS OF USE Intertek The underlayments described.in this.Research Report comply 8.0 OTHER CODES with,or are suitable alternatives to,what is specified in those Codes listed in Sections 1.0 and 2.0 of this report, subject to 8.1 Florida Building Code: the following conditions: 8.1.1 Scope of the Evaluation: Dupont- Tyvek® ProtecTM 5.1 Installation must comply with this Research Report,the 120, 160, and 200 underlayments were evaluated for manufacturer's published installation 'instructions, and the compliance with the 2020 Florida Building Code—Building applicable Code. In the event of a conflict between the and the 2020 Florida Building Code—Residential. manufacturer's instructions and this. report, this report governs. 8.1.2 Conclusion:The Dupont'"'Tyvek" Protec'"' 120, 160, and 200 underlayments described in Section 2.0 to 7.0 of 5.2 Installation is limited to use with approved mechanically this report comply with the 2020 Florida Building Code — attached roof covering systems. Building and the 2020 Florida Building Code—Residential, including High-velocity Hurricane Zones (HVHZ); subject to 5.3 Installation is limited to roof systems that do not involve the following conditions: hot asphalt or coal-tar pitch. The underlayment must be installed in accordance with the provisions noted in Sections 2.0 through 8.0 of this report, 5.4 Installation is limited to roofs with.a slope of 2:12(17%) Sections 1507 and 1518 of the Florida Building Code — or greater. Building, and Section R905 of the Florida Building Code— Residential 5.5 Attic ventilation must be provided in accordance with 3 Intertek is an approved evaluation entity and quality the applicable Code since there are no requirements to assurance entity pursuant to Florida Statute 553.842 — evaluate vapor permeability of the underlayment. Product Evaluation and Approval ® Use of the underlayments in discontinuous roof tile 5.6 The underlayments are manufactured under a quality systems is outside the scope of this report control program with inspections by Intertek Testing Services NA Inc. 9.0 CODE COMPLIANCE RESEARCH REPORT USE 6.0 SUPPORTING EVIDENCE 9.1 Approval of building products and/or materials can only be granted by a building official having legal authority in the 6.1 Reports of tests in accordance with ASTM E108. specific jurisdiction where approval is sought. 6.2 Data in accordance with ICC-ES Acceptance Criteria for 9.2 Code Compliance Research Reports shall not be used in Roof Underlayments (AC188), dated February 2012 any manner that implies an endorsement of the product by (editorially revised December 2015). Intertek Testing. 6.3 Intertek Listing Report titled "DuPont Synthetic Roofing 9.3 Reference to the https://bpdirectory.intertek.com is Underlayments". recommended to ascertain the current version and status of this report. 545 E.Algonquin Road 9 Arlington Heights•Illinois•60005 O intertek.com buildin a w,� Intertek PCA-101 Version:21 December 2017 5FT-CCRR-0P-40b ton . Code Compliance Research Report CCRR-1062 Page 3 of 3 TABLE 1—PROPERTIES EVALUATED PROPERTY IBC SECTION' IRC SECTION' FBC(BUILDING) FBC(RESIDENTIAL) 104.11,1506,:and R104.11,R904,and 104.11,1507,and Physical Properties R904 and R905 1507 R905 1518.4 Fire Classification 1505 R902.1 1505 R902 Ice Barrier 1507 R905 N/A N/A 'Referenced sections apply to 2018 IBC and IRC This Code Compliance Research Report("Report')is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Report.Only the Client is authorized to permit copying or distribution of this Report and then only in its entirety,and the Client shall not use the Report in a misleading manner. Client further agrees and understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and this Report does not represent authorization for the use of any Intertek certification marks.Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek. O�r 545 E.Algonquin Road•Arlington Heights•Illinois 6 60005 intertek.com/building Intertek PCA-tot Version:21 December 2017 5FT-CCRR-OP-40b lit ; . 111 BCIS Home .I Log In I User Registration I+Hot Topics I Submit Surcharge I Stats Facts I Publications I Contact Us I, BCIS Site Map'I Links I ,Search Florda ' rSO Product ApprovalIUSER:Public User L' �"�teigg ma's -U�::F Product Approval Menu>Product or Application Search>Application Llst.>Application Detail • FL# FL30343-R2 L a Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the:Commission if necessary. Comments Archived Product Manufacturer Premier Metal Address/Phone/Email 17613 South Hwy:475 Summerfield,FL34491 (352)356-1609 flvalldation@yaftoo.com Authorized Signature Ray Bowen flvalidation@yahoo.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the David Eng Evaluation Report Florida License PE-81377 Quality Assurance Entity PRI Construction Materials Technologies,LLC Quality Assurance Contract Expiration Date 08/03/2022 Validated By James R Wally,PE 0 Validation Checklist-Hardcopy Received Certificate of Independence FL30343 R2 COI 26ga SVCrimp pI ood.odf Referenced Standard and Year(of Standard) Standard Year UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code L Product Approval Method Method 1 Option D Date Submitted 10/21/2020 Date Validated 10/25/2020 Date Pending FBC Approval Date Approved 10/28/2020 Summary of Products ,PL_#.j --- , N j Model,Number or Name Description 30343..1__. _ „ :.t 01: 26ga 5V Crimp over plywood 26ga(min)5V Crimp over 15/32"(min)plywood ' mils of11se Installation Instructions Approved for use in HVHZ:No FL30343 R2 II 26ga 5VCrimp plywood.odf Approved for use outside HVHZ:Yes Verified By:David Eng,PE'81377 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-108.5 Evaluation Reports Other: 108.5psf with 12"-12"pattern at 12"oc FL30343 R2 AE 26ga 5VCrimp piywo df Created by Independent Third Party:Yes 30343.2 02:26ga PermaShield over plywood 26ga(min)PermaShield screw strip over 15/32"(min)plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL30343 R2 II 26ga PermaShield pLywood.pdf Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-116 Evaluation Reports Other:116psf fastener every hole WITH sealant,71psf FL30343 R2 AE 26ga PermaShield plywood.odf fastener every other hole Created by Independent Third Party:Yes 30343.3 03: 032 Aluminum PermaShield over Nominally 032 or thicker aluminum PermaShield screw strip plywood over 15/32"(min)plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL30343 R2 II 032AI PermaShield plywood.pdf Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-153.5 Evaluation Reports Other:153.5 with fastener every hole WITH sealant,86psf FL30343 R2 AE 032AI PermaShield plywood•pdf with fastener every hole with OUT sealant. Created by Independent Third Party:Yes 30343.4 04: 26ga Tuffft over plywood 26ga(min)TuffRib over 15/32"(min)plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL30343 R2 II 26ga TuffRib olywood.pdf Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-123.5 Evaluation Reports Other:123.5psf with 6.5"-2.5"-6.5"-2.5"fastener pattern @ FL30343 R2 AE 26ga TuffRib &wood.pdf 12"oc,82.25psf with.9"-9"-9"fastener pattern @ 24"oc Created by Independent Third Party:Yes 30343.5 05: 032 Aluminum DuraSeam over Nominally 0.032"or thicker aluminum DuraSeam over 15/32" plywood (min)plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL30343 R2 II 032AI DuraSeam plywood.pdf Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377 Impact Resistant:N/A Created by Independent,Third Party:Yes Design Pressure:+N/A/-108.5 Evaluation Reports Other:108.5 psf with clips @ 18"oc FL30343 R2 AE 032AI DuraSeam_plywood.pdf Created by Independent Third Party:.Yes 30343.6 06:26ga DuraSeam over plywood 26ga(min)DuraSeam over 15/32"(min)plywood Limits of Use Installation Instructions Approved for use in HVHZ:No, FL30343 R2 II 26oa DuraSeam pywood.pdf Approved for use outside HVHZ:Yes Verified By:David Eng,PE 81377 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-93.5 Evaluation Reports Other:93.5psf with clips @ 12"oc,63.Spsf with clips @ 16" FL30343 R2 AE 26ga DuraSeam plywood,p� oc Created by Independent Third Party:Yes 30343.7 07: 29ga TuffRib over plywood 29ga(min)TuffRib over 15/32"(min)plywood i Fastener in the rib Limits of Use Installation Instructions Approved for use in HVHZ:No FL30343 R2 II 29ga TuffRib Plywood-rib.Ddf Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-123.5 Evaluation Reports Other: 123.5 psf with 9"-9"-9 fastener pattern @ 12"oc, FL30343.R2 AE 29ga TuffRib Plywood-rib.pdf 56psf @ 24"oc Created by Independent Third Party:Yes 30343.8 08:29ga TuffRib on 1x4 battens over 29ga(min)TOM on 1.x4:(nom)battens over 15/32"(min) plywood plywood :Limits of Use Installation Instructions Approved for use in HVHZ:No FL30343 R2 II 29ga TuffRib 1X4.pdf Approved for use outside HVHZ:Yes Verified_By: David Eng,PE 81377 Impact Resistant:N/A Created by Independent,Third Party:Yes Design Pressure:+N/A/-131 Evaluation Reports Other:,131 psf with 9"-9"-9"fastener pattern @ 12"oc, FL30343 R2 AE 29ga TuffRib 1X4.pdf 78.5psf @ 24"oc Created by Independent Third Party:Yes 30343.9 09: 29ga TuffRib over plywood 29ga(min)TuffRib over 15/32"(min)plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL30343 R2 II 29ga TuffRib Ply wood.pd� Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377 Impact.Resistant:N/A Created by Independent Third Party:Yes Design,Pressure:+N/A/-93.5 Evaluation Reports Other:93.5 psf with 9"-9"-9"fastener pattern @ 12"oc,56psf FL30343 R2 AE 29ga TuffRib Ply wood.pdf @ 24"oc Created by Independent Third Party:Yes Bac!< Nex[ Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 phone:650-487-1824 The State of Florida Is an AAJEEO employer.Copyrjght 2007-2013:State of Florida.;;Privacy Statement::Accessibility Statement Refund Statement. Under Florida law,email addresses are public records.If you do notwant your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office.by phone or by traditional mail.If you have any questions,please contact 850,487.1395.'Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have'ane.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please Provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,.F.S.,please click ere. product Approval Accepts: 10 Credit Card Safe Ft30343 07-R2: § i FLORIDA PRODUCT APPROVAL 29GA TuffRib over 15/32 Plywood Premier Metal Roof Manufacturing 17613 S. Hwy 475 Summerfield FL 34491 :':'�� www.PMRoof.com 1 352-356-1609 `=� Product Description WIDE PANEL Exposed fastener, rib style panel. Panel coverage is nominally ti314" HIGH 36" with nominal rib height of 3/4" ' Product Material: 29ga (min) steel 29ga is nominally 0.0142"with yield strength of at least 50ksi, and TUFF RIB shall be corrosion resistant per FBC 1507.4.3 where required Fastener: #10 x 1.5 inch fastener with sealing washer Exposed Fastener Ribbed Panel Compliant with FBC 1506.6 where required. Substrate/Deck: 15132" (min) plywood. Panel may be installed over an optional layer of shingles. Maximum Allowable Loads & Installation Requirements: Method A: #10 x 2"fastener in 9"-9"-9"-9 pattern through.the rib (a) 24" oc: 56 PSF Method B:.:.#10 x 2"fastener in 9"-9"-9"-9" pattern through the rib 12" oc:: 123.5 PSF A factor of safety of 2 has been applied. Evaluated by: David Eng, PE I Timberlake Cove, LLC 3324 W Univ Ave#206 1 Gainesv \NXA I I I I► FL PE 813771 FL CA 33344 ��`�Jp E• www.TimberLakeCove.com ���OP v%CEN." David E Eng _ No.81377 2020.10.18 22:19:56+01100,This Hem has been digitally signed and 11 sealed by D.E.Eng,PE,on the date 0 � '•, STATE OF •• 1(/� indicated.Printed copies of this document .F4ORIDP.•' are not considered signed and sealed and i ...• `C the signature must be verified on any ,'�SS/ONAL electronic copies fi I n� —FL30343 0T4,2' x 4 {.F Z �x Uhderlayment: Comply with local building code or FBC 1507.1.1. Slope: Comply with local building code or FBC 1507.4.2. Technical Documentation: This product has been tested to UL 580 by Intertek Testing (TST-1527), report K9550.01-45044. Compliance Statement: This.product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2 (non- HVHZ) as required by FL Rule 61 G20-3, method 1 D. This product as described has been tested and demonstrated compliance with: • UL580—Test for Uplift Resistance of Roof Assemblies • UL 1897—Uplift test for roof covering systems Certification of Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. The same entities do not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Exclusions and Limitations: Design of deck and roof structure (to include attachment of plywood or wood.plank)shall be completed by others. Fire classification and shear diaphragm design are outside the scope of this evaluation. This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by Rule 61 G20-3: Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs made by others based on this evaluation report. This report is limited solely to documenting compliance with Rule 61020-3, and makes no express or implied warranty regarding performance of.this product. Design Process: The load tables in this report provides one prescriptive.option for the fastening requirement for the. applicable wind loads for roofs within the parameters described. For roofs outside of the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress. These load tables are based on ASCE 7-16. Use of these tables assumes that the structure is: • Enclosed and conforms to wind-borne debris provisions and is a regular shaped building • Is not subject to across-wind loading, vortex shedding, or instability; nor does it have a site location for which channeling or buffeting warrant consideration Engineering analysis may be completed by.other licensed engineers for project specific approval by local authorities having jurisdiction. c x a, � ' �c � e.,��p +"•pg�t„ `..� e�' � � g t $-� a .�'�:.. �;# � "� 'f � m a. t"'�"«.U, - 'f a ♦ � ry FL303, 07-R2 r PG -41 .- • ;_,•�� 2 2 . 2 2 3ja Instructions: 2 1 2 2 3 Select the appropriate load table that applies to the structure in 2 1 1 2 question. 2 1 Determine the design wind speed for the project location. Use the attachment method indicated for that windspeed within r--I a�- HIP ROOF GABIEROOF a�-� each roof zone. s 10:OF LEASTIIOIZONTAL OIAIENSION Oft DJIL PABOHEyER W SMALLER,BtR NOT LESS THAN EITHER 4%OF LEAST HORIZONTAL DAMNSION OR]FT IO VJT NOTE:ASCE 7-16 and FBC 2020 adopt a 7-zone concept. For the load tables OR ALS DETEANWE➢BY DESIGN OR OTHER APPLICABLE 000E below,the worst case was taken for each zone and reported using the standard ROOF ZONES FOR GENERIC BUILDING zones 1-2-3: Zone 1 includes zones 1 and 1' Zone 2 includes zones 2e, 2r,and 2n Zone 3 includes zones 3e and 3r Combining these zones creates a clear, simple scheme, at the expense of some design efficiency. Contact the manufacturer for further information, or consult a licensed design professional. METHOD A:_24" O.C. METHOD B: 12" O.C. NR: CONSULT DESIGN �911 ff 911� 9ff � PROFESSIONAL Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B,C,or D exposure area OHave either a flat roof,or gable/hip roof with max slope of 12:12 Have either a flat roof,or gable/hip roof with max slope of 12:12 ve a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less FL30343.07: 29 a Tuffrib on 15132"plywood FL30343.07: 29 a Tuffrib on 15132"Plywood Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A B 'B - ;B B I Zone 1: A A A A ` B .B. B . B. B B• Zone 2: A A A ,�A�,.. B B BB -B` B B. ' Zone 2: A B. B B ','B B i Zone 3: A A A 67 -B --'B ,B .-.B. B_� Zone 3: Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B;C,or D exposure area Have either a flat roof less than 1.5:12,hip roof with Have either a flat roof less than 1.5:12,hip roof with rnax slope of 12:12,or gable roof with slope between 4.4:12-12:12 max slope of 12:12,or gable roof with slope between 4.4:12-12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less FL30343.07: 29 a Tuffrib on 15/32" plimod FL30343.07:29 a Tuffrib on 15/32" plywood Wind 105 110 120 130- 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A A .,13 B B:I Zone 1: A A A A I• B B: B B ..13 B .'B_ Zone 2: A A A A A -B B B >B B B' Zone 2: A A B B � =B B Zone 3: A A A A B: B, . '8;:_ B_ B B. Zone 3: B_ B. .,13 B -B B . E r g