Loading...
HomeMy WebLinkAboutNOA; Series SGD-9000 Dry Glazed 8ft Aluminium Sliding Glass DoorM IAM I -DARE MIAMI DADE COUNTY, FLORIDA PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Lawson Industries, Inc. 8501 NW 90111 Street Medley, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewedand accepted by Miami -Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid afterthe expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/ orthe AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to p erform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "SGD 9000 Dry Glazed" 810" Aluminum Sliding Glass Door - N. I. APPROVAL DOCUMENT: DrawingNo.L9000-0901 RevD, titled "Series SGD-9000 Aluminum Sliding Glass Door (N.I.) No Steel Reinforcement", sheets 01 through 08 of 08, prepared by manufacturer, dated 06/04/09 and last revised on AUG 03, 2020, signed and sealed by Thomas J. Sotos, P. E., bearing the Miami - Dade County Product Control Section Revision stamp with the Notice of Acceptance number and Expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: None: Approved Hurricane Protection Devices Complying w/ FBC, as applicable, are required. Limitations: 1. See design Pressure chart VS door sizes, glass types and Sill height, in sheets 2. 2. Applicable door egress requirement to be reviewed by Building official LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERNHNATION of this NOAwill occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture ofthe product or process. Misuse ofthis NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section ofthis NOA shall be cause for termination and removal ofNOA. ADVERTISEMENT: The NOAnumber preceded by the words Miami Dade County, Florida, and followed b y the expiration date may be displayed in advertising literature. If any portion ofthe NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy ofthis entireNOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 17-1212.06 and consists ofthis page 1 and evidence pages E- 1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I. Chanda, P. E. NOA No. 20-0901.07 (tia Expiration Date: August 26, 2022 Approval Date: December 03, 2020 Page 1 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Evidence submitted in previous files A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA's No.'s 99-0517.05 and 09-0706.07) 2. Drawing No. L9000-0901, titled "Series SGD-9000 Aluminum Sliding Glass Door (N.I.) No Steel Reinforcement", sheets 01 through 08 of 08, prepared by manufacturer, dated 06/04/09, with the latest revision `B", dated 12/19/14, signed and sealed by Thomas J. Sotos, P. E. B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 along with marked -up drawings and installation diagram of an Aluminum Sliding Glass Door, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.'s HETI-09 2534 and HETI-08-2176, dated 05/05/09, both signed and sealed by Candido F. Font, P. E. (Submitted under NOA No. 09-0706.07) 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, Type "C" sliding door, Grade 10, per FBC 2411.3.2.1, TAS 202-94 and per ASTM F 842-04 along with marked -up drawings and installation diagram of an Aluminum Sliding Glass Door, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.'s FTL-2019, FTL-2021, FTL-2023, FTL-2024, FTL-2025, FTL 2028, FTL-2029 and FTL-2030, dated 01/04/99, all signed and sealed by Gilbert Diamond, P. E. (Submitted under NOA No. 99-0517.05) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC, prepared by Lawson Industries, Inc., dated 04/28/15, signed and sealed by Thomas J. Sotos, P. E. (Submitted under previous NOA No.14-0908.03) 2. Glazing complies with ASTM E1300-04/ 09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Technical data sheet of flexible vinyl compound FPVC 7267-75 (White) & FPVC 7200- 75 (Black), published by Team Plastics. Inc./ Bayshore Vinyl Compounds, Inc. a division of Mexichem SAB de CV, LLC. 1 Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0901.07 Expiration Date: August 26, 2022 Approval Date: December 03, 2020 E-1 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance to and complying with FBC 5th Edition (2014), issued by manufacturer, dated 05/24/17, signed and sealed by Thomas J. Sotos, P. E. 2. Statement letter of no financial dtd 01/22/09, signed and sealed by Thomas J. Sotos, P. E. (Submitted under NOA No. 09-0706.07) 3. Laboratory compliance letter for Test Report No.'s BETI-09 2534 and HETI-08- 2176, issued by Hurricane Engineering & Testing, Inc., dated 05/05/09, signed and sealed by Candido F. Font, P. E. (Submitted under NOA No. 09-0706.07) 4. Proposal No. 08-0591, issued by Product Control, dated 07/15/08, signed by Renzo Narciso. (Submitted under NOA No.12-1204.12) 5. Laboratory compliance letter for Test Reports No.'s FTL-2019, FTL-2021, FTL- 2023, FTL-2024, FTL-2025, FT r-2028, FTL-2029 and FTL-2030, issued by Fenestration Testing Laboratory, Inc., dated 01/04/99, all signed and sealed by Gilbert Diamond, P. E. (Submitted under NOA No. 99-0517.05) 6. Proposal issued by Product Control, dated 04/14/98, signed by Jaime D. Gascon, P. E. (Submitted under NOA No. 99-0517.05) G. OTHERS 1. Notice of Acceptance No. 14-0908.03, issued to Lawson Industries, Inc. for their Series "SDG-9000 8'0" Aluminum Sliding Glass Door w/o Reinforcement - N.I.", approved on 05/07/15 and expiring on 08/26/17. 2. Evidence submitted previous approval. A. DRAWINGS 1. Drawing No. L9000-0901 Rev C, titled "Series SGD-9000 Aluminum Sliding Glass Door (N.I.) No Steel Reinforcement", sheets 01 through 08 of 08, prepared by manufacturer, dated 06/04/09 and last revised on NOV 21, 2017, signed and sealed by Thomas J. Sotos, P. E. Note: This revision consists of editorial changes of FBC 17 (61h Edition) code compliance. B. Test 1. None. C. CALCULATIONS 1. None D. QUALITY ASSURANCE . 1. Miami Dade DepartmentofRegulatory and Economic Resources (RER). SSG L�i�n.k Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0901.07 Expiration Date: August 26, 2022 Approval Date: December 03, 2020 E-2 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of conformance to FBC 2017 (611 Edition) and "No financial interest" dated 11/17/17, prepared by the manufacturer, signed and sealed by Thomas J. Sotos, P.E. G. OTHER 1. This NOA revises # 17-0608.05, expiring 08/26/22. 3. New Evidence submitted. A. DRAWINGS 1. Drawing No. L9000-0901 Rev D, titled "Series SGD-9000 Aluminum Sliding Glass Door (N.I.) No Steel Reinforcement", sheets 01 through 08 of 08, prepared by manufacturer, dated 06/04/09 and last revised on DEC 03, 2020, signed and sealed by Thomas J. Sotos, P. E. Note: This revision consists of editorial changes of FBC 2020 (Th Edition) code compliance. B. Test 1. None. C. CALCULATIONS 1. None D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of conformance, to FBC 2020 (71h Edition) and "No financial interest" dated 08/03/20, prepared by the manufacturer, signed and sealed by Thomas J. Sotos, P.E. G. OTHER 1. This NOA revises # 17-1212.06 and updates to FBC 2020, expiring 08/26/22. Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0901.07 Expiration Date: August 26, 2022 Approval Date: December 03, 2020 E-3 943 114' DOOR WIDTH CLUSTER OF 18' MAX 4 ANCHORS , AT SOLE ENDS 6' MAX. T1P. �6' TYP A I I HEAD/SILL HEAD/SILL CORNERS 5/8" TEMP. INSULATED GLASS 3/16' TEMP. GLASS ON 08' PANELS OR SMALLER C D E F iD G o g B 57' 57' 57 3/8' 57' D.L. OPG. D.L. OPG. D.L. OPG. D.L. OPG. 61 7/8" 62 1/4' 61 7/8" 61 7/8" PANEL WIDTH PANEL WIDTH TYPICAL ELEVATION TESTED UNIT (OXXX) SGD-9000 ALUMINUM SLIDING GLASS DOOR NOTES: SEE SHEET 2 FOR DESIGN LOAD CAPACITY OF DESIRED PANEL SIZE. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE (2017-6th EDITION & 2020-7th Edition). WOOD -BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY -TO TRANSFER LOADS TO THE STRUCTURE. ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS, ANCHORS EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL PRODUCT REVISED ea comp) ng with The Florida Bu11dIng Soda NGA-To. 20-0901.07 Expiration Date08/26/2022 0 N NON —IMPACT By Isu"71•LS"�k ~ WITHOUT REINFORCING Mam1-Dade Product Control `jttTT51iP9BOt •. •Lt m .)•�� DOORS NOT RATED FOR IMPACT. "S 0 ,,, INSTALLATION OF THIS PRODUCT REQUIRES THE USE OF APPROVED SHUTTERS OR EXTERNAL PROTECTION DEVICES oci .Y COMPLYING WITH HVHZ REQUIREMENTS. ?¢ DESIGN LOAD CAPACITY - PSF PANEL WIDTH NOMINAL FT./IN. DOOR HEIGHT FT./IN. DOORS WITH 2 PANELS ONLY (3/16" TEMP. GLASS) 1-3/4" SILL 2-1/4" SILL 2-1/2" SILL 3" SILL EXT. (+) INT. (-) EXT. (+) INT. (-) EXT. (+) I INT. (-) EXT. (+)E 2/0 5/0 6/8 40.7 89.3 56.7 89.3 63.3 89.3 64.52/6 40.7 75.3 56.7 75.3 63.3 75.3 64.53/0 40.7 66.2 56.7 66.2 63.3 662 64.54/0 40.7 55.4 55.4 55.4 55.4 55.4 55.4 40.7 49.9 49.9 49.9 49.9 49.9 49.9 49.9 2/0 2/6 3/0 4/0 8/0 40.7 72.2 56.7 72.2 63.3 72.2 64.5 72.2 40.7 60.4 56.7 60.4 60.4 60.4 60.4 60.4 40.7 52.5 52.5 52.5 52.5 52.5 52.5 1 52.5 40.7 43.0 43.0 43.0 43.0 43.0 43.0 43.0 2/0 2/6 9/0 40.7 54.3 54.3 54.3 54.3 54.3 54.3 54.3 40.7 44.3 44.3 44.3 44.3 44.3 44.3 44.3 5/8" TEMP. INSULATED GLASS MAY BE USED IN 4X8' PANELS OR SMALLER. DESIGN LOAD CAPACITY - PSF PANEL WIDTH NOMINAL FT./IN. DOOR HEIGHT FT./IN. DOORS WITH 3 OR MORE PANELS (3/16" TEMP. GLASS) 1-3/4" SILL 2-1/4" SILL 2-1/2" SILL 3" SILL INT. (-) EXT. (+) INT. (-) EXT, (+) INT. (-) EXT. (+) INT. (-) 2/6 3/0 4/0 5/0 6/8 40.7 61.4 56.7 61.4 61.4 61.4 61.4 61.4 40.7 54.0 54.0 54.0 54.0 54.0 54.0 54.0 40.7 45.3 45.3 45.3 45.3 45.3 45.3 45.3 40.7 40.9 40.9 40.9 40.9 40.9 40.9 40.9 2/6 3/0 4/0 8/0 40.7 49.2 1 49.2 49.2 49.2 1 49.2 49.2 49.2 40.7 42.9 42.9 42.9 42.9 42.9 42.9 42.9 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 5/8" TEMP. INSULATED GLASS MAY BE USED IN 4X8' PANELS OR SMALLER. GLASS CAPACITIES ON THESE CHARTS ARE BASED ON ASTM E1300-98 (60 SEC. WIND) THIS APPROVES DOORS USING TWO (2) OR THREE (3) TRACK FRAMES WITH ANY NUMBER OF PANELS THAT CONTAIN THE STILE CONFIGURATIONS SHOWN ON SHEETS 4 AND 6, I.E. XX, OX, XO, XXX, OXO, OXXO, AND THE FOLLOWING POCKET DOOR CONFIGURATIONS: XXP, PXX, XXXP, PXXX, XXXXP, PXXXX, pXXXXP OXXXP, PXXXO ITEM 8 PART y QUANTITY DESCRUMON MATERIAL MANF./SUPPLIER/REMARKS 1 L-9001 1 FRAME HEAD (2 TRACK) 6063-T6 ALUM. PROFILE 2 L-9002 1 FRAME SILL (2 TRACK) 6063-T6 ALUM. PROFILE 3 L-9003 2 FRAME JAMB (2 TRACK) 6063-T5 ALUM. PROFILE 4 L-9004 1/ PANEL PANEL TOP RAIL 6063-T5 ALUM. PROFILE 5 L-9005 1/ PANEL PANEL BOTTOM RAIL 6063-T5 ALUM. PROFILE 6 L-9006 AS READ. LOCK STILE / FIXED STILE 6063-T5 ALUM. PROFILE 7 L-9007 AS READ. SINGLE INTERLOCK STILE 6063-T5 ALUM. PROFILE 8 L-9008 AS READ. ASTRAGAL STILE 6063-T8 ALUM. PROFILE 9 L-9043 AS READ. 3/16' GLAZING CHANNEL TEAM PLASTICS Inc. See Material Composition ® Sheet 8 10 FS-011 4/ PANEL PANEL ASS'Y SCREW ® TOP RAIL 810 x 5/8" P.H. - PHIWPS 11 FS-034 2/ PANEL PANEL ASS'Y SCREW ® BOTTOM RAIL - #10-24 X 1' P.H.-PHIL/ 'T' 12 FS-028 8 FRAME ASSEMBLY SCREW - 88 X 7/16" P.H-PHIL / SMS 13 7519-6001-7 AS READ. PILE WTS'P. to JAMB/ASTRAGAL - (0.187w. x 0.200"h.)-Schlegel 14 7524-6001-6 AS REQD. PILE WTS'P. ® TOP RAILS - (0.187"w. x 0.250%)-Schlegel 15 7529-6001-7 AS REQD. PILE WTS'P. ® BOTTOM RAILS - (0.187w. x 0.300%)-Schlegel 16 7520-5001-7 AS REQD. PILE WTS'P. D INTERLOCKS - (0.187'w. x 0.210"h.)-Schlegel 17 AS REQD. SILL RISER 6063-T5 ALUM. SIUCONED IN PLACE 18 L-9018 3 OR 4 • FIXED PANEL JAMB CUP 6063-T5 ALUM, GW-27153 19 FS-029 1/ CUP FIXED PANEL CUP SCREW - R8 X 5/8' PH. -PHI / SDS 20 AR-001 1 FIXED INTERLOCK ANGLE 6063-T5 ALUM. 3'x 1 1/2"x 1 9/16'x 1/8" AR-002 1 MOVING INTERLOCK ANGLE/CUP 6063-T5 ALUM. 1 1/2' X 3/4° X 2X 1/8 L-9022 1 ASTRAGAL RETAINER CUP 6063-T6 ALUM. AF-10798 • OPTIONAL SCREEN JAMB ADAPTER 6063-TS ALUM. - N L-9028 1 FRAME HEAD (3 TRACK) 6063-T6 ALUM. - L-9029 1 FRAME SILL (3 TRACK) 6063-T6 ALUM. - L-9030 2 FRAME JAMB (3 TRACK) 6063-T5 ALUM. - L-9031 AS REQD. DOUBLE INTERLOCK STILE 6063-T6 ALUM. OPTIONAL. 32 1071a 2/ PANEL PANEL TOP RAIL NYLON GUIDE ST801 Nylon 6-6 Molded Nylon- Rockwell M scale: 79 1072a 2/ PANEL PANEL BOTTOM RAIL NYLON GUIDE STS01 Nylon 6-6 Molded Nylon- Rockwell M scale: 79 HW4-WHL 2/ PANEL PANEL SINGLE ROLLER 6 COMPONENT - ASS'Y 150 HC-038 AS REQD. DOOR LOCK ASSEMBLY - INT. & EXT. PULLS, CAM, KEEPER P34 UI-109A 1/ PANEL 5/8" INSULATED PANEL TOP RAIL 6063-T6 ALUM. PROFILE UI-110A 1 PANEL 5/8' INSULATED PANEL BOTTOM RAIL 6063-T5 ALUM. PROFILE UI-108 1 PANEL 5/8" INSULATED PANEL LOCK STILE 6063-T6 ALUM. PROFILE UI-082 1/ PANEL 5/8' INSULATED PANEL INTERLOCK 6063-T6 ALUM. PROFILE 40 UI-163 1/ PANEL 5/8' INSULATED PANEL ASTRAGAL 6063-T6 ALUM. PROFILE 41 AF-10403 AS REQ'D. POCKET DOOR JAMB HOOK 6063-T6 ALUM, PROFILE 42 L-9045 AS REQD. 5/8 INSULATED GLAZING CHANNEL ITEAM PLASTICS Inc. See Material Composition ® Sheet 8 43 812-25H-357 AS REQD. "T uSeal" Dura Seal Swiggle Spacer I Black - 1/4' Air Space • 4 ON 9/0 HIGH DOORS ONLY 3/16' TEMP. GLASS t i m � z I � 1a it s is i! n 3/I6 TEMP. GLAZING DETAIL 3/16' TEMP. GLASS ^fjl:gsl.e,o� .t I--Alr space PRODUCT REVISED e''� . ... -- as com Iyyingg with the Florida I 42 3ulldlno Coda 'D; i, tn•a NOA-No. 20.0901.07 I! Expiration Dato08126/2022 win "•h N obi By Ist�7I.L6„s 46 z _ NDarr11-Dada Product Controlg�--- 5/8 TEMP. INSULATED GLAZING DETAIL TYPICAL ANCHORS SEE ELEV. FOR SPACING TWO (2) TRACK SECTION TYPICAL ANCHORS IN PAIRS TYPICAL ANCHORS IN PAIRS SEE ELEV. FOR SPACINGTYPICAL ELEV. FOR SPACING A. 1 1/4• • d n G Uw. EMBED.) • I 1 •. de WOOD BUCKS AND METAL STRUCTURES NOT BY LAWSON IND. MUST SUPPORT LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORS; ( SEE ELEV. FOR SPACING ) 1/4" DIA TAPCONS JTN BUILDER (FyL 100 Ksi. Fu= 125Ksi) 1 3/B' INTO 2BY WOOD BUCKS OR WOOD STRUCTURE (Mw. EMBED.) 1-3/8" MIN. PENETRATION INTO WOOD L— THRU 1BY WOOD BUCKS INTO MASONRY OR CONC. 1-1/4" MIN. EMBED INTO MASONRY OR CONC. DIRECTLY INTO CONCRETE OR MASONRY 1-1/4" MIN. EMBED INTO CONCRETE OR MASONRY #14 SMS OR SELF DRILLING SCREWS - GRADE 5 INTO METAL STRUCTURES STEEL : 12 GA. MIN. THICK - 0.105" (Fy - 36 KSI MIN.) ALUMINUM 1/8" THK. MIN. (6063-T5 MIN.) #10 SMS - GRADE 2 INTO MIAMI-DADE COUNTY APPROVED MULLIONS (MIN. THK. = 1/8") (NO SHIM SPACE) TYPICAL EDGE DISTANCES 'INTO CONCRETE AND MASONRY = 2-1/2" MIN. dg INTO WOOD STRUCTURE - 1" MIN. (OR AS SHOWN) RISER ADHERED TO WITH SILICONE INTO METAL STRUCTURE - 3/4" MIN. SUBSTRATES: WOOD BUCK (P.T.) AT HEAD OR JAMBS SG = 0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS F'c = 3000 PSI MIN. C-90 GROUT / FILLED BLOCK AT JAMBS F'm = 2000'PSI MIN. OPTIONS SEALANTS: ALL FRAME AND PANEL JOINT, INSTALLATION SCREWS AND HEADS OF ANCHOR SCREWS AT SILL TO BE SEALED WITH SEALANT. 0 C �10 10 CA q z M � h G 'O V O o mom A z;; �s } c �jz E o a s o0 �ry O o TYPICAL ANCHORS IN PAIRS Zx ¢ N W �'"• SEE ELEV. FOR SPACING y ca C z O O COUNTY APPR'D MULLION MIAMI-DARE SEE SEPARATE NOA 3 PItN R'Y Met.{ TNckne•t p• o N s a N t n N n N \ \O n QO TYPICAL ANCHORS IN PAIRS E ti E ci E ci E ci S SEE ELEV. FOR SPACING L �rc z z z PRODUCT REVISED ae eomplyying with tha Florida Bullding Codi Non -No. 20.0901.07 Expiration Date08/26/2022 By I5w.21.ZAt. Miami -Dade Product Control F •ty Czz7 N' rNil Alb �•uJ 41 � 0 c TYPICAL ANCHORS TYPICAL ANCHORS IN PARS IN PAIRS 4SEE ELEA FOR SPACING - SEE ELEV. FOR SPACING a ^ OO O O 1/4' SHIM w q Z 1/4' SHI M to MAX. 31 t- Q 0 V 3 INACTIVE PANEL ACTIVE PANEL 8 35 s ACTIVE PANEL ACTIVE PANEL a .e e a w Z A orn 19 01 a IJi M 'C 3 ¢ i r c y • O lL3t 2BY WOO LICK 6 e • . m a Cn OR WOOD U RE 1 s - .Q 13 O •'' rn wa p 0 9 1 J (D 22 ... •. y (n o 13 C� ®� L-SGREENS OPTIO ..___ _ ', •'',tl','• ' 3 z v / EXT. GRADE (MIK EMBED.) D.L. OPG. PERIMETER 1 t 4' �. #10 X 1-1/4' SMS CAULKING / p � N IF 10 SMS 410 % 1-1/4- SMS OR 3/16- TAPCDNS PANEL WIDTH UK EMBED.) OR 3/16' TAPCONS 2/ CUP �) O 2/ CUP 2/ CUP T. ••S. O BE LOCATED OXXX CUPS TO 'WOOByP UCK � M L CUP AT IN FRAME HEAD AND SILL SILL END ONLY EXTERIOR AT TOP & BOTTOM OF INTERLOCKS 71 _DOOR WIDTH #8 X 5/8- SCREW w o 0 3 FOR 8/0 DOORS 4 FOR 9/0 DOORS o r n N\ 1/4' MAX..• C`z O O 1/4' MAX. TYPICAL 0". FORRSPACING� SHIM, SHIM a 35 s PRODUCT REVISED — E E E E 1 8 Bulldinglylna with tho Florida ° Np11-No. 20.0901.07 s s 3 to Expiration oata08/26/2022 E z z a ° --- --- --- ------ is By Is'71.Z4,a Pitch Beyond Maml-0ada Product Control d m 6 o • •, • ' ; 16 I Metel Thickness ,. 13 13 • mod: ' 4. .�. a A-�-�METALSTRUCTURE? ;J<:,cotOXO PANEL WIDTH,rrn (urt EetBEDJ EXTERIOR o Q: °y DOOR WIDTH ONE.'•i•.+tr .,Y •�.PO SO``� TWO 2 TRACK SECTIONa TYPICAL ANCHORS d 1 1/4' ` .IN. EBBED.) ' TYPICAL ANCHORS IN PAIRS SEE ELEV. FOR SPACING d A: Q A e .. I a. WAMI-DADE COUNTY APPR'D MULLION SEE SEPARATE NOA IODUCT REVISED eompl Twith the Florida Iding o0 A -No. 20.0901.07 Ifratlon TDate06/26/2022 iml-Dade Product Contro 13/B' _. E IMBED.) POCKET JAMB HOOK RISER ADHERED TO WITH SILICONE )PTIONS Grout of Minimum 5 Ksi SEE ELEV. FOR SPACING THREE 3 TRACK SECTION MOVING PANEL TYPICAL ANCHORS IN PAIRS SEE ELEV. FOR SPACING TYPICAL ANCHORS IN PAIRS SEE ELEV. FOR SPACING x a 2BY WOOD BUCK p Tn � WOD STRUCTURE O 0 h I E Q m O Y n N N N N\ N S. m\m �o O 3 i 3 3 0 c ,3iv — �1/4' TAPCDN M oTn E E E E (SEE ANCHOR NOTES) a us H 8 8 1$ O POCKET DOOR JAMB ANCHOR DETAIL x z o: =d of e3 d _709 6q.�g884844QSyp U. Cj .;� ov' a Z e h . • .. J•��r'; t•3i. ��181 TYPICAL ANCHORS IN PAIRS SEE ELEV. FOR SPACING 1/4- SHIM MAX. 30 C T INACTIVE PANEL 1 3/8. (MIN. EMBE 1/4- MAX. O SHIM C INACTIVE PANEL 18 22 a •' 6 a .. 13 N p N 30 1 1/4 (MIN. EMBED.) Ile CAL ANCHORS IN PAIRS SEE ELEV. FOR SPACING O ACTIVE PANEL # 10 SMS 2/ CUP O 22 O a 1--SCREENS '0 V4" SMS OR 3/16' TAPCONS 2/ CUP 0 XXX CUP AT SILL END ONLY EXTERIOR DOOR WIDTH n ACTIVE PANEL OXX EXTERIOR n ()I ACTIVE TYPICAL ANCHORS IN PAIRS SEE ELEV. FOR SPACING F m 10 oz.. eY o vt E z .e owx E ACTIVE PANEL to 2 o E 5 ® 1 1 L— --- --- EXT. GRADE 010 X 1-1/4- SMS PERINF)T I OR 3/16- TAP DNS CAULK NG (MIN. EMBED.) 2/ CLIP CUPS TO BE LOCATED 1BY PT IN FRAME HEAD AND SILL WOOD BUCK Q AT TOP &BOTTOM OF INTERLOCKS I 1/4• Max PRODUCT REVISED SHIM eom 1y1ng with the Florida Building Code NOA No. 20-0901.07 c, a n Expiration Date 08/26/2022 N By I s�7 I. Z4-1, Mioeaml-Made Product Control _I THREE 3 TRACK SECTIONSECTION Pitch Beyond tot Thickness z I � C) cg ci ci ci N s s s GSi 0 ;y+gt<a9t6171f7PPPP . "�� n PP�A • .••......•••;� `s Ot• CV �z '.3 F!�• Gj •y A WOOD DUCKS NOT BY LAWSON IND. MUST SUSTAIN IMPOSED LOADS • TYPICAL ANCHORS a v •,e•, PAIRS S SEE ELEV. FOR SPACING p O 39 MOVING 1B --- •e FIXED PANEL O El G 3 y o a mow:,•; .. N' 39 nE ' EXT. GRADE SCREEN DI ERIMETER CAULKING �1 1/4- (MIN. BASED.) 2 1 2• Min. ge is TYPICAL ANCHORS 1 'av••. ad N PAIRS �� IE6d8Eb.) SEE ELEV. FOR SPACING' (MIN ° " • e •. <. I/4' MAX, •.�-_ , SHIM INTERIOR SIDE I.G.- TEMP. GLASS \ O MOVING 0 0 22 20-_SL--JLJL__ PANEL SCREEN DOOR WIDTH EXTERIOR SIDE 1/4, SHIM MAX, D C �o c 5/0' I.G. - TEMP. GLASSco p e e C 39 O t SEL 5/6' I.G. - TEMP, GLASS ° m 00 3 _ -- 38 ° 0 Z_v 9 0 FIXED PANEL - Z co 3 i _- -- _.� i 41. 39 ° o v 1 1/4• y N t (MIN. 1BY WOOD EMBED.) P.T. BUCK fi I N 1 i Note: I INSULATED PANELS APPROVED TO BE USED �1 IN ANY CONFIGURATION SIMILAR TO THOSE AS SHOWN ON SHEETS 4, 5, & 6. ra-+`.1J T PRODUCT REVISED ilkl mr e "R�'r+'�JII�� I i i i i iI q 5/8' I.G. -TEMP, GLASS SIDE INTERIOR SIDE per• WrTOU RLD• SILL RISER ADHERED TO I, I Ii l 37 % SILL WITH SILICONE t-3/ 2-!�44- . OPTIONS d.- ' ya •� :'' •A •a d r A (uul. EDGE oLsrJ as comp) ngg with the Florida Building ode NOA-No. 20-0901.07 Eaplratlon Data08/26/2022 By I sw Z I. CF„a Mlaml-0ade Product Control PANEL TOP CORNER tl -- - — 10 X r SMs INTO ROLLER ROLLER HOUSING 0 hqS O PANEL BOTTOM CORNER ;t tip e0I V3 c9 0 nl ,�1 i� illit:2 t�-3.625-I 2.500 -^I .687 - - -{.656 F- L000 62 TYP. •780 L044 .37E I I 1.218 31� 8 A62 TYP. nd o .062 o c FRAME HEAD (2) TRACK LOCK STILE 3.Lt 1.218 w 5.087 5.0941.468 8 .062 TYP. II 1.000 .060 TYP. .750 ,062+iF- 1.810 1.044 I I 1218 -I .687 F- SILL RISER FRAME HEAD (3) TRACK FOR 2 & 3 TRACKS 2,375 -I.soof FRAME JAMB (2) TRACK FRAME JAMB (3) TRACK -i .690 F- DOUBLE INTERLOCK I I 2.375 � A62 .062Z75 2438 TYP. •062 ,875 1.37� L938 1.132 I.044 '�;P-43t8 1,470 1590 -I.SOOF- I 062 1,032 .890 TYP, 11.468 INSULATED LOCK STILE INSULATED PANEL TOP RAIL PANEL TOP RAIL PANEL BOTTOM RAIL SINGLE INTERLOCK 090 -{ 2.938 2.875 .595 094 .908 094 N ,376 L656 ,062 1.656 2533 n a L875 .062 •062 �4.154� .890 i- 2.313 2250 INSULATED BOTTOM RAIL FRAME SILL (2) TRACK ASTRAGAL STILE INSULATED ASTRAGAL .07e f] N I.590 1J32 � ,094 r5.672-�1 2,313 FRAME SILL (3) TRACK 1 INSULATED INTERLOCK ,524 .875 91 070 ,615 .062 I-f F-L142 1250 -1 20 ASTRAGAL RETAINER CUP JAMB HOOK FIXED PANEL CUP Flexible Vinyl FPVC Com osition-Team Plastics Inc. 11. FPVC Black: Compound No.7200-75 PHYSICAL ASTM NO. DurometerHardness "A",10 sec 75 D2240 SpecifteGmvity 1.45 D-792 Tensile Strength, PSI 1640 DL38 Ultimate Elonption, % 340.0 D-638 Modulus@ I00%Elongation, PSI 765.0 D-638 Impact Brittleness. -3I.0 D-746 12. FPVC White: Compound No. 7267-76 PHYSICAL ASTM NO. Durometcr Hardness W.10 sec 75 D-2240 Specific Gravity IA5 D•792 Tensile Strength,PSI 1640 D-638 Ultimate Elonption, % 325.0 D-638 Modulus @ 100% Elongation, PSI 765.0 D-638 Impact Brittleness, -30.0 D-746 FRAME BOTTOM CORNER I PRODUCT REVISED as eomply1ngg with the Florida Building doze NOA-no. 20.0901.07 Expiration Date 08/26/2022 Miami -Dade Product Control y Or^ m C Z a ao I �3 GI�m (Lb Oi c f/] rota � �i W O i a �qzl ® cr 00 Uj O 0 W C4 O �-4z 0 N r s s =1 i3 of ti o 4-•�ODp,�65C�'8k80�g9\7Qd` .v. 1. .,. +7� s•s h- )� 1 25 °.'IV D