Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET IL ?o a ST. LUCIE 'NORKS 1> A ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code-Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required Roof System the Permit Application See List Below Form LOW Slope Application A,B,C i,2,3,4;6,8,7 Prescriptive BUR-RAS SSO A,B,C 2,4,5,6,7 Asphaltic Shingles A,B,D Concrete or Clay Tile A,B,D,E 1,&3,4.%6,7 Metal Roofs A,B,D L2,3,4,6,6,T Wood Shingles and A,B,D 1,2,4,6,8,7 Shakes Other As Applicable 1,2,3,4,6,6,7 ATTACHMENTS REQUIRED As Applicable): r3. Fire Directory Listing Page From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations(Reroofing Only) 7, Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18,2021 ST. LUCIE 'NORKS Section C(Low Slope Roof) Surfacing: Fill In specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment. manufacturer Zone 1':_"oc @ Lap,#Rows_@—a (if a component is not used,identify as"NA") Zone 1:_"oc @ Lap,#Rows_@_00 System Manufacturer: Zone 2:—"oc @ Lap,#Rows—@_00 Zone 3:_"oc @ Lap,#Rows—@_"tm Product Approval No.: Number of Fasteners Per Insulation Board: Design Wind Pressures,From RAS 128 Or Calculations: Zone 1':—Zone 1:—Zone 2:—Zone 1— Zone 1':_Zone 1:_Zone 2:_Zone 3:_ Illustrate Components Noted and Details as Applicable: Max.Design Pressure,from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping, system: Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing,Coping,Etc., Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base TYpe� Flashing,Component Material,Material'Thickness,Fastener Type,Fastener Spacing or Submit Manufacturers Details that Gauge Thickness: Comply with RAS 111 and Chapter 16.. Slope: Anchor/Base Sheet&No.df Ply(s): N/A Ff. Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Instillation Size and Thickness: Parapet Base Insulation Fastener/Bonding Material: Height Top Insulation Layer: Top Insulation Size and Thickness: M Top Insulation Fastener/Bonding Material: Mean Base Sheet(s)&No.of Ply(s): Roof Base Sheet Fastener/Bonding Material: Height Ply Sheet(s)'&No.of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof System Manufacturer: JA TAYLOR ROOFING EDGE-LOC 1" STANDING SEAM Notice of Acceptance Number:NOA:18-1023.17 Minimum Design Wind Pressures, If Applicable(From RA5 127 or Calculations): Zone 1: -57 Zone 2e:-101 Zone 2n: Zone 2r;-P19 Zone 3e:--J2$Zone 3r; Deck Type: LPLYWOOD Type Underlayment ELF AQHEREQ IJNQERLAYMENT Tp PQLYGLASS MTS FL#5259.7 Roof Slope: �s : 12 Insulation: Fire Barrier: Ridge Ventilation? Fastener Type&,Spacing: 1 6"FIELD/4" PERIMETER, 817 RINGS NK NAILS Adhesive Type: Type Cap Sheet: Mean Roof Height: 1 FT Roof Covering: METAL Type&Size Drip 2"X 2 112" Edge: ST. LUCIE WORKS Section E(Tile Calculations) For Moment based file systems,choose either Method 1 or 2.Compare the values for M,with the values from Mr.If the Mtvalues are greater than or equal to the M,values,for each area of the roof,then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: -Xl-= _ I-Mg:-=bin_ Product ApprovalM (Zone 2e: ,-XA_= _)-Mg;-=Mo,_ Product ApprovalM (Zone 2n: '_xA_= _)-MIT,-=Mm,- Product Approval (Zone 2r: _.Xx_= ]-Mg:-=M,,_ Product Approval Mt (Zone 3e: --X).-= -Mg:-=Mo.__ Product Approval Mt (Zone 3r: =x).-= .- -Mg:-=Mai- Product ApprovalM Method 2"Simplified Tile Calculations Per Table Below" Required Moment of Resistance(Mr)From Table Below.Product Approval Mt__ M,required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' 4U' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems • For Uplift based tile systems use Method 3.Compare the values for F'with the values for F,If the "values are greater than or equal to the F,values,for each area of the roof,then the tile attachment method is acceptable. Method 3"Uplift Based Tile Calculations Per RAS 12T (Zone 1:_x L =x W _ -W:_cos r=F,z_ Product Approval F' (Zone 2e:_x L.=xW:=_)-W:_cos r =Frz•_ Product Approval F' (Zone 2n:_x LxW:=___-)-W:_cosr =Fao_ Prod uct Approva l F' (Zone 2r:lx L=x W:=_)-W:-Cos r_=Fn,_ Product Approval F' (Zone 3e: x L_xW:=_ -W:-cos r_=F,a._ Product Approval F' (Zone 3r._x LxW:=_)-W:_cos r_=F,a_ Product Approval F' Where to Obtain Information Description Symbol Where to fiM Design Pressure Zones 1,2e,2n,2r,3e,3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE] Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Muhiptier a Product Approval Restoring Moment due to Gravity Ma Product Approval Attachment Resistance Mt Product Approval Required Moment Resistance Ma Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance F, Calculated Average Tileweight W Product Approval Tile Dlmensians I I lensmW=width Product Approval All calculations must be submitted to the building official at the time of permit application.