HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
REC'Fi1x-9
Project Name: LEONHARDT RESIDENCE
Builder Name:
Street: 18601 ORANGE AVENUE
Permit Office: ST LUCIE COUNTY
MAY 1 2 2021
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: PETER LEONHARDT
Jurisdiction: ST LUCIE COUNTY
ST. Lucie County, Permittinc
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2
1. New construction or existing New (From Plans)
10. W all Type�1620.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Polystyrene Bead AggrER=0.0 1620.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
11. Ceiling Types (1680.0 sgft.)
Insulation Area
5. Is this a worst Case? No
a. Roof Deck (Unvented)
R=20.0 1680.00 ft2
6. Conditioned floor area above grade (ft2) 1680
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(126.0 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: MUD RM
R ft2
6 130
a. U-Factor: Sgl, U=0.65 126.00,Jt2,..
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
25.6 SEER:17.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
14. Heating systems
kBtu/Efficiency
Area Weighted Average SHGC: 0.250
a. Electric Strip Heat
1 7.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1680.0 sqft.) Insulation Area
EF:0.980
a. Slab -On -Grade Edge Insulation R=0.0 1680.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
None
Glass/Floor Area: 0.075 Total Proposed Modified Loads: 49.96
PASS
Total Baseline Loads: 52.07
I hereby certify that the plans and specifications covered by
Review of the plans and
O�TE STq?�p,
this calculation are in compliance with the Florida Energy
specifications covered by this
-0%
Code.
calculation indicates compliance
rij, �h� ' _'
�'�%� '
with the Florida Energy Code.
1'•;;�`�
PREPARED BY:
DATE: 5-11-2021
Before construction is completed
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed,)* in compliance
Florida Statutes.
with the Florida Energy Code.
CAD W615.
OWNER/AGENT-
BUILDING OFFICIAL:
DATE: � LJ- `Zssa-�
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1; and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (11402.4.1.2). O
lrl%k
4/23/2021 1:11 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6
.0.
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: LEONHARDT RESIDENCE Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1680
Lot #
Owner Name: PETER LEONHARDT
Total Stories: 1
Block/SubdhAsion:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
18601 ORANGE
AVEN
Permit Office: ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Family Type: Detached
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
v Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1680 15120
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 MUD RM
198 1782 No
0
1 Yes
Yes
Yes
2 M BATH
192 1728 No
0
1 Yes
Yes
Yes
3 MASTER BEDROO
278 2502 No
0
1
1 Yes
Yes
Yes
4 W/D
24 216 No
0
1 No
Yes
Yes
5 KITCHEN
240 2160 Yes
0
1 Yes
Yes
Yes
6 FOYER/GREAT RM
360 3240 No
0
1 Yes
Yes
Yes
7 M CLST
28 252 No
0
1 Yes
Yes
Yes
8 PANTRY
108 972 No
0
1 Yes
Yes
Yes
9 BATH 2
72 648 No
0
1 Yes
Yes
Yes
10 BEDROOM 2
170 1530 No
0
1
1 Yes
Yes
Yes
11 CLST 2
10 90 No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
MUD RM 40 ft
198 ftZ
-_--
1 0
0
2 Slab -On -Grade Edge Insulation
M BATH 12 ft
192 ftZ
-_--
1 0
0
3 Slab -On -Grade Edge Insulation
MASTER BEDRO 33 ft
278 ftZ
__--
1 0
0
4 Slab -On -Grade Edge Insulation
W/D 1 ft
24 ftZ
1 0
0
5 Slab -On -Grade Edge Insulation
KITCHEN 19 ft
240 ftZ
_---
1 0
0
6 Slab -On -Grade Edge Insulation
FOYER/GREAT R 20 ft
360 ftZ
____
1 0
0
4/23/2021 1:11 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT 5UMMAKY GF1tGK1LI5I KtPUKI
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
7 Slab -On -Grade Edge Insulation M CLST 2 ft
28 ft2
----
1
0
0
8 Slab -On -Grade Edge Insulation PANTRY 21 ft
108 ft2
----
1
0
0
9 Slab -On -Grade Edge Insulation BATH 2 6 ft
72 ft2
----
1
0
0
10SIab-On-Grade Edge Insulation BEDROOM 2 25 ft
170 ft2
----
1
0
0
11SIab-On-Grade Edge Insulation CLST 2 2 ft
10 ft2
----
1
0
0
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 1820 ft2
0 ft2
Light
N
0.3
No 0.9
No 20
22.62
ATTIC
IRCC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
1
Full attic Unvented
0
1680 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) MUD RM
0
Blown
198 ft2
0.1
Wood
2
Under Attic (Unvented) M BATH
0
Blown
192 ft2
0.1
Wood
3
Under Attic (Unvented) MASTER BEDRO
0
Blown
278 ft2
0.1
Wood
4
Under Attic (Unvented) W/D
0
Blown
24 ft2
0.1
Wood
5
Under Attic (Unvented) KITCHEN
0
Blown
240 ft2
0.1
Wood
6
Under Attic (Unvented) FOYER/GREAT R
0
Blown
360 ft2
0.1
Wood
7
Under Attic (Unvented) M CLST
0
Blown
28 ft2
0.1
Wood
8
Under Attic (Unvented) PANTRY
0
Blown
108 ft2
0.1
Wood
9
Under Attic (Unvented) BATH 2
0
Blown
72 ft2
0.1
Wood
10
Under Attic (Unvented) BEDROOM 2
0
Blown
170 ft2
0.1
Wood
11
Under Attic (Unvented) CLST 2
0
Blown
10 ft2
0.1
Wood
WALLS
Adjacent Cavity Width
Height
Sheathing Framing Solar
Below
Space
1
N
Exterior Concrete Block - PolystyreftdUD RM
0 11
0 9
0
99.0 ft2
0
0
0.3
0
2
E
Exterior Concrete Block - PolystyredWJD RM
0 18
0 9
0
162.0 ft2
0
0
0.3
0
3
S
Exterior Concrete Block - PolystyreiWUD RM
0 11
0 9
0
99.0 ft2
0
0
0.3
0
4
N
Exterior Concrete Block - Polystyrerfd BATH
0 12
0 9
0
108.0 ft2
0
0
0.3
0
5
N
Exterior Concrete Block - PolystykffiTER BE
0 18
0 9
0
162.0 ft2
0
0
0.3
0
6
W
Exterior Concrete Block - PolystyTER BE
0 15
0 9
0
135.0 ft2
0
0
0.3
0
7
E
Exterior Concrete Block - PolystyreK@TCHEN
0 19
0 9
0
171.0 ft2
0
0
0.3
0
8
W
Exterior Concrete Block - PolystyffOYER/GRE
0 20
0 9
0
180.0 ft2
0
0
0.3
0
4/23/2021 1:11 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
Pr)PRA PAn9;_gngn- INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar
Below
Space
9
W
Exterior Concrete Block - Polystyrerfd CLST
0 2 0 9
0
18.0 ft2
0
0 0.3
0
-10
E
Exterior Concrete Block - Polystyredb4NTRY
0 12 0 9
0
108.0 ft2
0
0 0.3
0
11
S
Exterior Concrete Block - Polystyreffb%NTRY
0 9 0 9
0
81.0 ft2
0
0 0.3
0
12
S
Exterior Concrete Block - Polystyren@ATH 2
0 6 0 9
0
54.0 ft2
0
0 0.3
0
13
S
Exterior Concrete Block - PolystySEDROOM
2 0 13 0 9
0
117.0 ft2
0
0 0.3
0
14
W
Exterior Concrete Block - PolystyBEIDROOM
2 0 12 0 9
0
108.0 ft2
0
0 0.3
0
15
S
Exterior Concrete Block - PolystyrenGLST 2
0 2 0 9
0
18.0 ft2
0
0 0.3
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S Insulated MUD RM
None
.23
3
6 8
20 ft2
2
E Insulated KITCHEN
None
.23
3
6 8
20 ft2
3
W Insulated FOYER/GRE
None
.23
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
E 2 Metal Low-E Single Yes
0.65 0.25 Y
12.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2
N 5 Metal Low-E Single Yes
0.65 0.25 Y
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
3
W 6 Metal Low-E Single Yes
0.65 0.25 Y
40.0 ft2
2 ft 0 in
1 ft 4 in
None
None
4
E 7 Metal Low-E Single Yes
0.65 0.25 Y
9.0 ft2
2 ft 0 in
1 ft4 in
None
None
5
W 8 Metal Low-E Single Yes
0.65 0.25 Y
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6
W 14 Metal Low-E Single Yes
0.65 0.25 Y
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
INFILTRATION
#
Scope
Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000286
1260 69.13 129.78
.0946
5
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
COPA
17 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/ Split
Single SEER: 17
25.6 kBtu/hr 768 cfm
0.8 1
sys#1
4/23/2021 1:11 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
MUD RM
0.98
50 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
— Supply --
— Return —
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 130 ft2
Attic
13 ft2
Default Leakage
MUD RM
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Cooling[ ] Jan [ ] Feb
Heatin[X] Jan [X] Feb
[ j Mar
[X] Mar
[ ] Apr
[ ] Apr
Ma
May
Jun [X] Jul
Jun ] Jul
n
AugX]
Auj
jj
Se
]Sep
Oct [ ]
Oct [X]
Nov
Nov
Dec
Dec
Ventin [[ ]] Jan [[ ]] Feb
[[XX]] Mar
[X] A r
[ Ma
l
Jun ] Jul
E
Aug
[ ] Se
[X] Oct [X]
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78 78
78
78 78
78
78
80 80
80
80
PM
80
80 80
80
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78 78
78
78 78
78
78
80 80
80
80
PM
80
80 80
80
78 78
78
78
78 78
78
78
Heating (WD) AM
65
65 65
65
65 65
65
68
68 68
68
68
PM
68
68 68
68
68 68
68
68
68 68
68
68
Heating (WEH) AM
65
65 65
65
65 65
65
68
68 68
68
68
PM
68
68 68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
OFFICE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
OFFICE CLST
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LIVING/DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2.
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8lbs/sq.ft.
ft2
ft
0.3
MUD RM
4/23/2021 1:11 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default 8 Ibs/s .ft. ftz ft 0.3 LAUNDRY