Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method REC'Fi1x-9 Project Name: LEONHARDT RESIDENCE Builder Name: Street: 18601 ORANGE AVENUE Permit Office: ST LUCIE COUNTY MAY 1 2 2021 City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: PETER LEONHARDT Jurisdiction: ST LUCIE COUNTY ST. Lucie County, Permittinc Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 1. New construction or existing New (From Plans) 10. W all Type�1620.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Polystyrene Bead AggrER=0.0 1620.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 11. Ceiling Types (1680.0 sgft.) Insulation Area 5. Is this a worst Case? No a. Roof Deck (Unvented) R=20.0 1680.00 ft2 6. Conditioned floor area above grade (ft2) 1680 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(126.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: MUD RM R ft2 6 130 a. U-Factor: Sgl, U=0.65 126.00,Jt2,.. SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 25.6 SEER:17.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. 14. Heating systems kBtu/Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 1 7.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1680.0 sqft.) Insulation Area EF:0.980 a. Slab -On -Grade Edge Insulation R=0.0 1680.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.075 Total Proposed Modified Loads: 49.96 PASS Total Baseline Loads: 52.07 I hereby certify that the plans and specifications covered by Review of the plans and O�TE STq?�p, this calculation are in compliance with the Florida Energy specifications covered by this -0% Code. calculation indicates compliance rij, �h� ' _' �'�%� ' with the Florida Energy Code. 1'•;;�`� PREPARED BY: DATE: 5-11-2021 Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed,)* in compliance Florida Statutes. with the Florida Energy Code. CAD W615. OWNER/AGENT- BUILDING OFFICIAL: DATE: � LJ- `Zssa-� DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1; and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (11402.4.1.2). O lrl%k 4/23/2021 1:11 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 .0. FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: LEONHARDT RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1680 Lot # Owner Name: PETER LEONHARDT Total Stories: 1 Block/SubdhAsion: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 18601 ORANGE AVEN Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1680 15120 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MUD RM 198 1782 No 0 1 Yes Yes Yes 2 M BATH 192 1728 No 0 1 Yes Yes Yes 3 MASTER BEDROO 278 2502 No 0 1 1 Yes Yes Yes 4 W/D 24 216 No 0 1 No Yes Yes 5 KITCHEN 240 2160 Yes 0 1 Yes Yes Yes 6 FOYER/GREAT RM 360 3240 No 0 1 Yes Yes Yes 7 M CLST 28 252 No 0 1 Yes Yes Yes 8 PANTRY 108 972 No 0 1 Yes Yes Yes 9 BATH 2 72 648 No 0 1 Yes Yes Yes 10 BEDROOM 2 170 1530 No 0 1 1 Yes Yes Yes 11 CLST 2 10 90 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MUD RM 40 ft 198 ftZ -_-- 1 0 0 2 Slab -On -Grade Edge Insulation M BATH 12 ft 192 ftZ -_-- 1 0 0 3 Slab -On -Grade Edge Insulation MASTER BEDRO 33 ft 278 ftZ __-- 1 0 0 4 Slab -On -Grade Edge Insulation W/D 1 ft 24 ftZ 1 0 0 5 Slab -On -Grade Edge Insulation KITCHEN 19 ft 240 ftZ _--- 1 0 0 6 Slab -On -Grade Edge Insulation FOYER/GREAT R 20 ft 360 ftZ ____ 1 0 0 4/23/2021 1:11 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT 5UMMAKY GF1tGK1LI5I KtPUKI FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 7 Slab -On -Grade Edge Insulation M CLST 2 ft 28 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulation PANTRY 21 ft 108 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulation BATH 2 6 ft 72 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulation BEDROOM 2 25 ft 170 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulation CLST 2 2 ft 10 ft2 ---- 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1820 ft2 0 ft2 Light N 0.3 No 0.9 No 20 22.62 ATTIC IRCC V # Type Ventilation Vent Ratio (1 in) Area RBS 1 Full attic Unvented 0 1680 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MUD RM 0 Blown 198 ft2 0.1 Wood 2 Under Attic (Unvented) M BATH 0 Blown 192 ft2 0.1 Wood 3 Under Attic (Unvented) MASTER BEDRO 0 Blown 278 ft2 0.1 Wood 4 Under Attic (Unvented) W/D 0 Blown 24 ft2 0.1 Wood 5 Under Attic (Unvented) KITCHEN 0 Blown 240 ft2 0.1 Wood 6 Under Attic (Unvented) FOYER/GREAT R 0 Blown 360 ft2 0.1 Wood 7 Under Attic (Unvented) M CLST 0 Blown 28 ft2 0.1 Wood 8 Under Attic (Unvented) PANTRY 0 Blown 108 ft2 0.1 Wood 9 Under Attic (Unvented) BATH 2 0 Blown 72 ft2 0.1 Wood 10 Under Attic (Unvented) BEDROOM 2 0 Blown 170 ft2 0.1 Wood 11 Under Attic (Unvented) CLST 2 0 Blown 10 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N Exterior Concrete Block - PolystyreftdUD RM 0 11 0 9 0 99.0 ft2 0 0 0.3 0 2 E Exterior Concrete Block - PolystyredWJD RM 0 18 0 9 0 162.0 ft2 0 0 0.3 0 3 S Exterior Concrete Block - PolystyreiWUD RM 0 11 0 9 0 99.0 ft2 0 0 0.3 0 4 N Exterior Concrete Block - Polystyrerfd BATH 0 12 0 9 0 108.0 ft2 0 0 0.3 0 5 N Exterior Concrete Block - PolystykffiTER BE 0 18 0 9 0 162.0 ft2 0 0 0.3 0 6 W Exterior Concrete Block - PolystyTER BE 0 15 0 9 0 135.0 ft2 0 0 0.3 0 7 E Exterior Concrete Block - PolystyreK@TCHEN 0 19 0 9 0 171.0 ft2 0 0 0.3 0 8 W Exterior Concrete Block - PolystyffOYER/GRE 0 20 0 9 0 180.0 ft2 0 0 0.3 0 4/23/2021 1:11 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 Pr)PRA PAn9;_gngn- INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 9 W Exterior Concrete Block - Polystyrerfd CLST 0 2 0 9 0 18.0 ft2 0 0 0.3 0 -10 E Exterior Concrete Block - Polystyredb4NTRY 0 12 0 9 0 108.0 ft2 0 0 0.3 0 11 S Exterior Concrete Block - Polystyreffb%NTRY 0 9 0 9 0 81.0 ft2 0 0 0.3 0 12 S Exterior Concrete Block - Polystyren@ATH 2 0 6 0 9 0 54.0 ft2 0 0 0.3 0 13 S Exterior Concrete Block - PolystySEDROOM 2 0 13 0 9 0 117.0 ft2 0 0 0.3 0 14 W Exterior Concrete Block - PolystyBEIDROOM 2 0 12 0 9 0 108.0 ft2 0 0 0.3 0 15 S Exterior Concrete Block - PolystyrenGLST 2 0 2 0 9 0 18.0 ft2 0 0 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated MUD RM None .23 3 6 8 20 ft2 2 E Insulated KITCHEN None .23 3 6 8 20 ft2 3 W Insulated FOYER/GRE None .23 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 2 Metal Low-E Single Yes 0.65 0.25 Y 12.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 N 5 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 2 ft 0 in 1 ft 4 in None None 3 W 6 Metal Low-E Single Yes 0.65 0.25 Y 40.0 ft2 2 ft 0 in 1 ft 4 in None None 4 E 7 Metal Low-E Single Yes 0.65 0.25 Y 9.0 ft2 2 ft 0 in 1 ft4 in None None 5 W 8 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 6 W 14 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000286 1260 69.13 129.78 .0946 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 17 25.6 kBtu/hr 768 cfm 0.8 1 sys#1 4/23/2021 1:11 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None MUD RM 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply -- — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 130 ft2 Attic 13 ft2 Default Leakage MUD RM (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling[ ] Jan [ ] Feb Heatin[X] Jan [X] Feb [ j Mar [X] Mar [ ] Apr [ ] Apr Ma May Jun [X] Jul Jun ] Jul n AugX] Auj jj Se ]Sep Oct [ ] Oct [X] Nov Nov Dec Dec Ventin [[ ]] Jan [[ ]] Feb [[XX]] Mar [X] A r [ Ma l Jun ] Jul E Aug [ ] Se [X] Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 OFFICE Default(8 Ibs/sq.ft. ft2 ft 0.3 OFFICE CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING/DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2. ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8lbs/sq.ft. ft2 ft 0.3 MUD RM 4/23/2021 1:11 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. ftz ft 0.3 LAUNDRY 4/23/2021 1:11 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6