Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL FRENCH DOORSNOA No. 21-0113.10 Expiration Date: December 20, 2023 Approval Date: February 25, 2021 Page 1 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA)www.miamidade.gov/economy E.S. Windows, LLC 3550 N. W. 49th Street Miami, FL 33142 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION:Series “3000” Aluminum Outswing French Doors w /wo Sidelites APPROVAL DOCUMENT:Drawing No.W04-51 Rev N,titled “Series -3000 Alum Outswing French Doors (LMI)”, sheets 1, 2, 2.1, 2.2 through 5, 5.1, 6, 6.1 and 7 of 7, prepared by Al-Farooq Corporation, dated 06/10/2004 and last revised on 01/11/2021, signed and sealed by Jalal Farooq, P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Limitations: 1. Lower Design Pressures (DP) of Doors, sidelites, hardware, glass and threshold (sill) options shall control. 2. See sheets 1 &2 for doors,2.1 for single sidelite and 2.2 for doors w/ sidelites (Reinf/unRinf) mullion options within tested frame area. 3. The Water Rating +DP with STD sill=+70 PSF (X & XX) and Hi-Rise sill =+90 PSF (XX) and +100 PSF(X). 4. The frame are of alternate size must not exceed 97.58 ft2, nor panel tested area and max. Panel height. LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo, Barranquilla, Columbia, state and series and following statement: "Miami-Dade County Product Control Approved", noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official This NOA revises NOA #17-1226.11 and consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Sifang Zhao, P.E. 02/25/2021 Sifang Zhao, P.E. Product Control Examiner NOA No. 21-0113.10 Expiration Date: December 20, 2023 Approval Date: February 25, 2021 E -1 E.S. Windows, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1.Evidence submitted in previous NOAs’ A. DRAWINGS 1.Manufacturer's die drawings and sections (Submitted under NOA #09-0825.04) 2. Drawing No. W04-51 Rev M, titled “series -3000 Alum Outswing French Doors (LMI)”, sheets 1, 2, 2.1, 2.2 through 5, 5.1, 6, 6.1 and 7 of 7, prepared by Al-Farooq Corporation, dated 06- 10-04 and last revised on DEC 05, 2018, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94(see sheet 2) 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 Along with marked-up drawing and installation diagram of aluminum outswing French door w/ Sidelite (OXX), prepared by Intertek/ Architectural Testing, Inc., No.F2673.01- 450-18, dated 11/16/15, signed and sealed by Joseph A. Reed, P.E. (Submitted under NOA #16-0316.06) 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94(see sheet 2) 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 Along with marked-up drawing and installation diagram of aluminum outswing French door w/ Sidelites, prepared by Fenestration Testing Laboratory, Inc., No.FTL-5938, dated 10/01/09, signed and sealed by Julio E. Gonzales, P.E.Note: This test report has been revised, reviewed, signed and sealed on 03/29/10 by Jorge A. Causo, P.E. (Submitted under NOA #09-1217.03) 3. Additional Test Reports: Test reports issued by Fenestration Testing Laboratory, Inc Test report No(s)FTL-3947 & FTL-3955 per TAS 201, 202 & 202-94, dated 02/04/04, both signed and sealed by Edmundo J. Largaespada, P.E. and test report No.FTL-5164 per TAS 201/203-94, issued by Fenestration Testing Laboratory, Inc, dated 08/01/07, signed & sealed by Carlos S. Roinda, P. E.(Submitted under NOA #09-0825.04) 4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94(see sheet 2) 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 Along with marked-up drawing and installation diagram of aluminum Single and double doors outswing French door w/ Sidelite (OXX), prepared by Blackwater Testing, Inc., No. BT-ESW-16-011, dated 03/16/17, signed and sealed by Constantin Bortes, P.E. (Submitted under NOA #17-1226.11) Sifang Zhao, P.E. Product Control Examiner NOA No. 21-0113.10 Expiration Date: December 20, 2023 Approval Date: February 25, 2021 E -2 E.S. Windows, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS 1. Anchor verification calculations and structural analysis complying with FBC (2017), prepared by Al Farooq Corporation, dated 09/15/17, signed and sealed by Javad Ahmad, P.E. 2.Glazing complies w/ ASTME-1300-02, -04 & -09. D. QUALITY ASSURANCE 1.Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. NOA No.17-0808.02 issued to Kuraray America, Inc. for the “Sentry Glass ® Interlayer”, expiring on 07/4/23. 2.NOA No.16-117.01 issued to Kuraray America, Inc., Inc. for the “Kuraray Trofosil Ultra clear and color PVB Interlayer, expiring on 07/08/19. F. STATEMENTS 1.Distribution agreement between Energia Solar, S.A.-ES Windows and ES Windows, LLC, dtd 08/03/15, signed by Ms. Carla Garcia (MGR) and Andres Chamorro (Gen. MGR). 2.Statement letter of conformance to FBC 2017 (6th Edition) and letter of no financial interest, prepared by Al Farooq Corporation, dated 09/15/17, signed and sealed by Javad Ahmad, P.E. G. OTHER 1.This NOA revises and renews NOA # 17-1114.03,expiring 12/16/23. 2. New Evidence submitted A. DRAWINGS 1. Drawing No.W04-51 Rev N,titled “Series -3000 Alum Outswing French Doors (LMI)”, sheets 1, 2, 2.1, 2.2 through 5, 5.1, 6, 6.1 and 7 of 7, prepared by Al-Farooq Corporation, dated 06/10/2004 and last revised on 01/11/2021, signed and sealed by Jalal Farooq, P.E. B. TEST 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1.Notice of Acceptance No.20-0915.22 issued to Kuraray America, Inc. for their “Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers”, expiring on 07/08/24. 2.Notice of Acceptance No. 20-0915.19 issued to Kuraray America, Inc. for their “SentryGlas® (Clear and White) Glass Interlayers”, expiring on 07/04/23. F.STATEMENTS 1. Statement letter of conformance, complying with FBC 6th Edition (2017), with FBC 7th Edition (2020), and of no financial interest, dated 01/08/2021, prepared by Al-Farooq Corporation, signed and sealed by Jalal Farooq, P.E. G. OTHER 1. This NOA revises NOA # 17-1226.11,expiring 12/16/23. 12/20/202321-0113.10 12/20/202321-0113.10 12/20/202321-0113.10 12/20/202321-0113.10 12/20/202321-0113.10 12/20/202321-0113.10 12/20/202321-0113.10 12/20/202321-0113.10 12/20/202321-0113.10 12/20/202321-0113.10 12/20/202321-0113.10