Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SOLAR PV SYSTEM
po SYSTEM DESIGN z _m w V w s o SYSTEM TYPE UTILITY GRID INTERACTIVE �J08 ow= A SOLAR PV SYSTEM IMPROVEMENT FOR. - RATED DC POWER 7480 W `?� - �3z RATED AC POWER 5280 W PEROCCHI RESIDENCE 2 C5 PV MODULE QCELLS 340 W x (22) 0 INVERTER(S) ENPHASE IQ7 x (22) _ ENERGY STORAGE SYSTEM NONE SOLAR IMPROVEMENT CONSTRUCTION DOCUMENTS STORAGE CAPACITY N/A FOR THE EXISTING RESIDENTIAL GRID TIED ELECTRICAL SYSTEM _ EXISTING ELECTRICAL 120/240 VAC, 1 - 3a GOVERNING CODES & STANDARDS BILL OF MATERIALS 2020 FLORIDA BUILDING CODE (7TH EDITION) 22 QCELLS 340 W MODULES o 2020 FLORIDA RESIDENTIAL CODE (7TH EDITION) 22 ENPHASE IQ7 MICROINVERTERS w 2017 NATIONAL ELECTRIC CODE (NFPA 70) 22 ENPHASE Q CABLE CONNECTORS PROJECT: SEI/ASCE 7-16 2 ENPHASE 6 FT EXTENSION CABLES UNDERWRITERS LABORATORIES STANDARDS (UL) 2 ENPHASE END CAPS w 2 IRONRIDGE XR-100 RAILS - 17 FT. < SITE SPECIFICATIONS 6 IRONRIDGE XR-100 RAILS - 14 FT. "' g ZD 4 IRONRIDGE XR-100 RAILS 1 1 FT. N o y WIND SPEED (Vult) 160 MPH - N za WIND EXPOSURE B 6 IRONRIDGE XR-100 SPLICE KITS W L RISK CATEGORY II 12 IRONRIDGE XR-100 END CAPSLU U o 11 IRONRIDGE MICROINVERTER MOUNTING KITS J 0 GROUND SNOW LOAD 0 PSF 0 LU Cn MOUNTING METHOD ROOF-MOUNTED (FLUSH) 50 IRONRIDGE UFO CLAMPS a o 12 IRONRIDGE UFO END SLEEVES 0 z a SITE LOCATION MAP 76 RT-MINI MOUNTS 0 v N ww � 3 GROUND LUGS _ 00 Ile NEMA 3R ROOF JUNCTION BOX DATE 6/25/21 DRAWN BY: AL �" SITE OCATION calvary open bible PLAN SHEET DESCRIPTION CHECKED BY: JLA community church REC.NO.# 29127 Np PV.O COVER SHEET SCALE AS NOTED aN 425 SE Tranquilly Ave, PV.1 PHOTOVOLTAIC MODULE LAYOUT & ROOF PLAN DRAWING# =_�N Port St. Lucie, FL 34983 PV.2 STRUCTURAL ATTACHMENT DETAILS - e& PV.3 ELECTRICAL DIAGRAM & SCHEDULES Pv.o8SHEET 1 OF 5 k obile DreamiWorks concr PV.4 ELECTRICAL NOTES & WARNING LABELS -Q Digitally signed vpU1S o3= ANTO by John L p No.TBt1305 .*- i `O?�'� P' Antonelli �A�'. STATE OF Date:2021.06.28 crS�ONALE� „II wgnalsyretureentltlrte^vnnguCm0lesol o 67¢ '11:58:15 -04'00 o€� o ICON LEGEND — / , OELKTRIC METER INVERTER I W U g 01 zgo LLai �:Eo� ~az MSP MAIN SERVICE PANEL ® ROOF WIND ZONE 3 <? w$ z W _ LC LOAD CENTER ROOF OBSTACLE s 3 Z m_ z. Z � PLP PROTECTED LOADS PANEL FIRE SETBACK ZONE z w� CBP COMBINER PANEL MOUNTINGRAIL m ® JUNCTION BOX ♦ MOUNTING POINT z AC DISCONNECT CONDUIT ma o� TRANSFER SWITCH _y Y zg Q k� 3 EXISTING ROOF NOTES I.EXISTING ROOF IS ASPHALT SHINGLE ROOFING OVER WOOD DECKING& MINIMUM 2X4 S.Y.P.WOOD TRUSSES. NOTE:ROOF CONSTRUCTION IS BASED ON INFORMATION PROVIDED TO THE DESIGNER.ALL ROOF PENETRATIONS SHALL BE FLASHED AND/OR SEALED USING APPROVED PRODUCTS&METHODS PER LOCAL GOVERNING CODE. 2.ROOFTOP SOLAR COMPONENTS REPRESENT A GRAVITY LOAD OF 3 PSF. -PV MODULES=2.5 PSF MOUNTING EQUIPMENT=0.25 PSF -MISCELLANEOUS ACCESSORIES=0.25 PSF PROJECT: 3.EXISTING ROOF IS ASSUMED TO BE DESIGNED FORA MINIMUM LIVE LOAD OF 20 PSF.PER FBC 1607.125.1 ROOF SURFACES COVERED BY SOLAR PV MODULES SHALL BE CONSIDERED INACCESSIBLE AND,THUS,THE LOAD IMPOSED BY THE SOLAR PV MODULES WOULD BE LESS THAN THE LIVE LOAD RATING& ABLE TO SUSTAIN THE ADDITIONAL GRAVITY LOAD IMPOSED BY THE SOLAR PV MODULES AND ASSOCIATED ATTACHMENTS. W 4.MODULE LOCATION ON ROOF MAY BE ALTERED IN THE FIELD SO LONG AS EQUIPMENT'S MOUNTED AS SHOWN ON SHEET PV.2. Q a ACCESS PATHWAY PER w W 2020 FRC R324.6 ROOF ACCESS REQUIREMENTS 2020 FRC R324.6&2020 Z ZD FFPC ED R324.6 ROOF ACCESS AND PATHWAYS 2 Z EXCEPTIONS: W Q APPROXIMATE LOCATION � LU Cle 1.DETACHED,NON-HABITABLE STRUCTURES SHALL NOT BE REQUIRED TO PROVIDE W I.— OF(E)ELECTRIC METER ROOF ACCESS. Z = w APPROXIMATE LOCATION OM W N M 1.ROOF ACCESS,PATHWAYS,&SETBACKS NEED NOT BE PROVIDED WHERE THE OF(E)MAIN DISTRIBUTION QCELLS 34OW MODULE U Lf') co CODE OFFICIAL HAS DETERMINED THAT ROOFTOP OPERATIONS WILL NOT BE PANEL TYp. Q O (\I 0' EMPLOYED, VA APPROXIMATE LOCATION MSP IRONRIDGE XR100 RAIL,TYP. O � � M 3,THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS WITH SLOPES OF 1:11(17% OF(N)AC DISCONNECT (2)PER MODULE ROW N W V) J SLOPE)OR LESS. (n LI- APPROXIMATE LOCATION APPROXIMATE LOCATION OF U LJ..I W R324.6.1 PATHWAYS OF IN)PV COMBINER PANEL RT-MINI MOUNT CONNECTION Q CC tY W i0 SHINGLE ROOFING.FLASH G 0 V 1.(2)OR MORE 36"PATHWAYS ON SEPARATE ROOF PLANES FROM EAVE TO CBp PER 1010 FBC.SEE SHEET PV,1 Q 0 RIDGE. FOR DETAILS. O Z Q J 2.(1)OR MORE 36"PATHWAYS ON ROOF PLANES ADJACENT TO THE STREET OR ROOFTOP JUNCTION BOX ♦— I--- DRIVEWAY. APPROXIMATE LOCATION 3.(I)OR MORE 36"PATHWAYS ON ROOF PLANES WITH PV ARRAYS EITHER ON, FOR WIRE TRANSITION. O W W " ADJACENT TO,OR STRADDLING THE SAME&ADJACENT ROOF PLANES FROM SEE SHEET PV.3 O O m g EAVE TO RIDGE. O 0 m R324.6.2 SETBACK AT RIDGE d d d d FOR PV ARRAYS OCCUPYING<33%OF THE PLAN VIEW TOTAL ROOF AREA,A MIN. 18"CLEAR SETBACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE.FOR PV ARRAYS OCCUPYING>33%OF THE PLAN VIEW TOTAL ROOF AREA,A MIN.36" DATE 1 6/25/21 CLEAR SETBACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. o w CORNER WIND ZONE.SEE DRAWN BY: JLL R324.6.2.2 EMERGENCY ESCAPE AND RESCUE OPENING SHEET PV.2 FOR a ANCHORING REQUIREMENTS CHECKED BY: JLA a PANELS AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED ON THE m PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE AND RESCUE REC.NO.# 29127 " OPENING.A MIN.36"PATHWAY SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. SCALE AS NOTED w DRAWING# -€m ROOF LAYOUT NOTES o ROOF LAYOUT SHOWN MAY BE ADJUSTED IN THE FIELD BY THE INSTALLER i0 ACCOUNT FOR ISSUES CAUSED BY ROOF OBSTACLES,TRUSS ALIGNMENT,OR Pv. o€ SHADING.SO LONG AS THE MODULES ARE MOUNTED AND SECURED TO THE ROOF AS SHOWN ON PV.2 THE LAYOUT MAY BE ALTERED. SHEET 2 OF S 3 �pU1SAyl �i- Ilysigned •��CENSF by John L = No.81305 Antonelli w�3 Qom•, FTATE OF G(/� �w� PHOTOVOLTAIC MODULE LAYOUT & ROOF PLAN 1 ;(Cs'••.�ORIDP.•�G\� �U� Date: SCALE: 32"=1'-0° PV.1 S/ONALE. yl/l nnf"` w 2021 .06.28 biz"emMs beeaeieRra�mllyzi�tla"tl __ secletlbVlobn LouisAn[onegl pEusinga �V!2 Digital5ignatureantltlate.printetlmpiesof d 11 :59:23 -04L00 tleame",are"n,mnaitleretlaig etlaM seal etl and tM1e zignmure must be vent ietl on anyeleNonicmples. o€� PHOTOVOLTAIC MODULE GENERAL NOTES: iTRS 4TRS iTRS 4TRS iTRS 4TRS iTRS 4TRS iTRS 3" IRONRIDGE LL 'po PV MODULE 8 UFO CLAMP MAX.R IL SPAN 'Z' I, I Z FRAME PV MODULE a`€ 1.APPLICABLE CODES&STANDARDS: �� IRONRIDGE FRAME )_0 501 2020 FLORIDA BUILDING CODE(7TH EDITION) I - I Z° O UFO CLAMP ® IRONRIDGE o o TRUSS MOUNT-RT MINI J O5 1.o V -2020 FLORIDA RESIDENTIAL CODE(7TH EDITION) T� i i i i �oy� F� ASCE-7-16 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. RAIL �i� SCREW PATTERN-(2)#10 a F w o 2.WOOD SCREW DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2020 FLORIDA BUILDING CODE d ' WOOD SCREWS-2" ? z t I I ' w o o EMBEDMENT 33 REQUIREMENTS. ALL SCREW CAPACITIES ARE BASED ON A SOUTHERN YELLOW PINE(SYP)RESIDENTIAL WOOD MID CLAMP-PLAN MID CLAMP-SIDE 3 z w ROOF TRUSS AND/OR APA RATED SHEATHING(7/16"OSB OR 15/32"PLYWOOD)AS EMBEDMENT MATERIAL. I I �I - - _I 4. z z „z. 3.ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIDENTIAL ROOFS,CONSIDERING a IRONRIDGE w FROM A 7*TO A MAXIMUM 27*(2/12 TO A MAXIMUM 6/12 PITCH)ROOF IN SCHEDULE.ALL RESIDENTIAL N :E IRONRIDGE RAIL 1" V. UFO CLAMP = ROOFS SHALL NOT TO EXCEED 30'-0"MEAN ROOF HEIGHT. L - - - - J O H. IRONRIDGE PV MODULE DECK MOUNT-RT-MINI 4 ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511,AND IS THE RESPONSIBILITY OF THE PORTRAIT ORIENTATION I I UFO CLAMP FRAME IRONRIDGE h o SCREW PATTERN-(5)#10 m CONTRACTOR TO PILOT FILL ALL HOLES.CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE 3 IRONRIDGE WOOD SCREWS-FULL INSTALLED AND SEALED PER 2020 FLORIDA RESIDENTIAL CODE(7TH EDITION)OR LOCAL GOVERNING CODE. - - - STOPPER SLEEVE STOPPER PENETRATION-SEE DETAIL 5.THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. V.2 MAX.R IL SPAN SLEEVE 3/PV.2 FOR DETAILS 3 PV MODULE 4" 6.THIS DRAWING COVERS ALL PV MODULES WITH A NOMINAL SIZE OF 39"X 78"OR LESS. FRAME IRONRIDGE RAIL a s 7.ALL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. v END CLAMP-PLAN END CLAMP-SIDE o L,- - ii END & MID CLAMP CONNECTION DETAILS ROOF TECH RT MINI MOUNT DETAIL o2 EXPOSURE B-RISK CATEGORY II-GABLE ROOF>7-27 I I SCALE: 1 Z'=1'-0" SCALE: 12'=1'-0" _ Vasd WIND PRESSURE (PSF) X= Y g VuH GROUP 1 GROUP 2 GROUP 3 SCREW QTY.& v X• IRONRIDGE XR1000 12"ALUM.INTERNAL a k y (MPH) 1 2e 2n 2r 3e 3r EMBED.DEPTH �H � 3� (+) (-) (+) (.) (+) (-) REQ. LANDSCAPE ORIENTATION LANDSCAPE ORIENTATION OR XR 100 ALUM. SPLICE BAR(ATTACH 1 b.0 37.5 16.0 56.2 1 b.0 67.4 (LONG AXIS)** (SHORT AXIS SOLAR RAIL,TYP WITH(4)#12-14 5," MAXIMUM RAIL SPANS&OVERHANGS (2)#10,2" STAINLESS STEEL STS, 1 b0 SPAN OVERHANG SPAN OVERHANG SPAN OVERHANG EMBEDMENT TYP.) o 4'-0"O.C. V-7"O.C. 2'-0"O.C. 9"O.C. 2'-0"O.C. 9"O.C. NOTES: EXPOSURE B-RISK CATEGORY II-HIP ROOF>7-27 1.SEE SCHEDULE THIS SHEET FOR MAXIMUM RAIL SPAN. _ -- W Vasd WIND PRESSURES(PSF) 2.SEE SCHEDULE THIS SHEET FOR MAX.RAIL OVERHANG.MAX.O.H.IS RAIL SPAN X 0.40. 1 SCREW QTY.& VuIT GROUP 1 GROUP 2 GROUP 3 3.'Z'IS ALLOWABLE DISTANCE BETWEEN RAIL AND MODULE EDGE PER MODULE (MPH) 1 2e 2r 3 EMBED.DEPTH MANUFACTURER. PROJECT: (+) (-) (+) (-) REQ' **LONG AXIS MOUNTING NOT ALLOWED FOR ALL MODULES.CHECK MANUFACTURER 1'-0" 16.0 -33.7 16.0 -44.9 16.0 -48.7 REQUIREMENTS. L-FOOT WITH 160 MAXIMUM RAIL SPANS&OVERHANGS (2)#10,2" #12-14 x 5/8"STAINLESS ROOF TECH RT-MINI SPAN OVERHANG SPAN OVERHANG SPAN OVERHANG EMBEDMENT TYPICAL PHOTOVOLTAIC MODULE STEEL SELF-TAPPING w 4'-0"O.C. 1'-7"O.C. 2'-0"O.C. 9"O.C. 2'-0"O.C. 9"O.C. SCREW-(4)PER SPLICE -PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY FROM SURFACES, MOUNTING PLANS 2 < RESPECTIVELY. 3,_ TYPICAL SOLAR RAIL BEAM SPLICE DETAIL APPROVED MOUNTING HARDWARE w a GROUPS ARE MADE UP OF ROOF WIND ZONES WITH IDENTICAL WIND PRESSURES.SEE DETAIL BELOW SCALE:16'-1 0 PV.2 w J " SCALE: N.T.S. N Z FOR WIND ZONE LOCATIONS."--"IN TABLE INDICATE CONDITIONS WHERE INSTALLATION IS NOT SCALE: 1 2 V-0" r Z ZD ALLOWABLE. N wp d SCHEDULE REFLECTS COMPONENTS AND CLADDING(C&C)NOMINAL WIND PRESSURES WITH EXPOSURE SEE DETAILS THIS SHEET NOTE: DECKING-ONLY MOUNTING MAY ONLY SEE DETAILS THIS SHEET N Q "B",RISK CATEGORY II, ENCLOSED BUILDING AND h<60'-0"PER ASCE 7-16 AND 2020 FLORIDA FOR APPROVED BE DONE IMMEDIATELY ADJACENT TO A FOR APPROVED w LU � BUILDING CODE. MOUNTING HARDWARE TRUSS-MOUNTED CONNECTION ALONG RAIL. MOUNTING HARDWARE Z w MAXIMUM SPACING BETWEEN TRUSS Lu = cn cM -WOOD SCREW DEPTH REQUIRED IN WOOD TRUSS SHALL EXCLUDE ANY ROOF DECKING THICKNESS. CONNECTION&DECKING-ONLY CONNECTION U co -CONNECTIONS SHALL BE MADE INTO TRUSSES EXCEPT AS SHOWN IN DETAIL 3/PV.2 THIS SHEET. LIMITED TO THAT SHOWN IN SCHEDULE BELOW. J O " 01 v o Cie M DECK CONN.SPAN BY ZONE GROUP w vi GABLE ROOFS HIP ROOFS N a w w PHOTOVOLTAIC PHOTOVOLTAIC V w Lu w o MODULE TYP. GROUP SPAN GROUP SPAN MODULE TYP. 0 V - - - NOTES: ,IQ�J;L\ 1 32" 1 36" N1\ O Z < 1.A DIMENSION DEFINED PER ASCE 7-16 O.�QSC� 2 21 2 26 OBE > SHALL BE 4 FT PER FBC 2020(7TH t S��CV 3 17" 3 24" S��C\ O (J u N EDITION)FIGURE R301.2(7). w_ w_ 8 2."0"DIMENSION IS ROOF PITCH,7"-27". Q O O Me a ASPHALT SHINGLES ASPHALT SHINGLES = O w TYPICAL ROOF ELEVATION Q ALUM.L-FOOT FASTENED TO OR METAL ROOFING ALUM.L-FOOT FASTENED TO f� OR METAL ROOFING a a s a RAIL W/ 3/8-16 ST.STL. ° ? TYP. RAIL W/ 3/8-16 ST.STL. ° ? TYP. Q BONDING BOLT&NUT BONDING BOLT&NUT Q 3r 0Q Qe DATE 6/25/21 ® € ® 2 �Q - - - 7 - DRAWN BY: JLL PV•2 WOOD MIN.15/32"APA-RATED CHECKED BY: JLA s SHEATHING PLYWOOD SHEATHING w y � � � REC.N0.# 29127 � 2 WOOD ROOF �A�y SCALE AS NOTED a TRUSS TYP. ' IRONRIDGE XR1000 IRONRIDGE XR1000 DRAWING# I OR XR 100 ALUM. OR XR 100 ALUM. a I / \ SOLAR RAIL TYP. SOLAR RAIL TYP. o „ O ROOF TECH RT-MINI MOUNT ROOF TECH RT-MINI MOUNT PV.2 p o w WITH SELF-FLASHING BUTYL WITH SELF-FLASHING BUTYL o€= ® © 3r 3r © ® a a ® REFER TO SCHEDULE FOR SEALANT SEALANT SHEET 3 OF 5 o �k REQUIRED EMBEDMENT DEPTH (2)#10 ST STL WOOD (5)#10 ST STL WOOD LABELED"X"IN THIS DETAIL. SCREWS-LENGTH TO E 0 g A' A' A' A' /^�� ,�j� pU1S ANT',,,, ACHIEVE 2"EMBEDMENT D �" L � °"" ��'CENS Qy INTO TRUSS THRO H DE KI pZ: e TYPICAL GABLE ROOF PLAN TYPICAL HIP ROOF PLAN ` y �o"�i n L No.81305 TYPICAL PHOTOVOLTAIC MODULE LAYOUT - HIP & GABLE *- Antonelli Q ,• STATE OF :•�(/� �w� ROOFS - ROOF WIND ZONE PLAN TYPICAL ROOF CONNECTION DETAIL TO TRUSS TYPICAL ROOF CONNECTION DETAIL TO DECKING �(C 'F<ORIDP.•'G\�: W 1 3 a ate: �' .. SCALE: N.T.S. PV,2 SCALE: 1 2"=V-0" PV.2 SCALE: 1 2"=l'-0" PV 2 SS�ONALE?`` 06.29 a.. iiYau a."a L xaeab ion"mmaa"ro"eni ne"ame. a '11:59:45 -04'00aae� anYelechoni"wPles. tb fal o€� PHOTOVOLTAIC SYSTEM POWER TABLE (3)#10 THHN/THWN-2 IN 3/4 LOAD SIDE TAP-COMPLY 0 LL p DC-SIDE PV MODULE DC-INPUT AC-SIDE MICROINVERTER BRANCH N0.1 BRANCH N0.2 HOME RUN "CONDUIT WITH NEC 705.12(B) z a <<€ MODULE QTY. 1 1 QTY. 1 11 11 22 NOTES: 30A/2P (E MDP 1 8$ o�1 SERIES 1 1 MODEL IQ7 --- --- --- 1.REFER TO SHEET PV.4 FOR ALL APPLICABLE ELECTRICAL NOTES. z o PARALLEL 1 1 MANUFACTURER ENPHASE --- --- --- 2.SYSTEM MEETS REQUIREMENTS OF NEC 2017 690.12 FOR RAPID TO O TO J�y w INVERTER Ll L2 GRID a F- MANUFACTURER QCELLS --- CONT.POWER 240 W 2640 W 2640 W 5280 W SHUTDOWN.INSTALL PER MANUFACTURER INSTRUCTIONS. ��a w o 3.ALL CONDUCTORS SHALL BE COPPER UNLESS NOTED OTHERWISE.MINIMUM z MODEL DUO BLK-G6 VOLTAGE 240 VAC 240 VAC 240 VAC 240 VAC (E)ELECTRIC 33 z RATED POWER 340 W 340 W CONT.CURRENT 1.00 A AC 11.00 A AC 11.00 A AC 22.00 A AC CONDUCTOR SIZES SHOWN THIS SHEET. (N)30 A SERVICE N METER ?3 W w o 4.THIS SHEET IS DIAGRAMMATIC IN NATURE AND MAY NOT DEPICT ALL RATED FUSED TO(E) o w Voc 40.66 VDC 40.66 VDC FREQUENCY 60 HZ 60 HZ 60 HZ 60 HZ 2 REQUIRED COMPONENTS OR CIRCUITS AS THEY MAY EXIST.THE PURPOSE OF DISCONNECT SUBPANEL Isc 10.52 ADC 10.52 ADC MODULE QTY. 1 11 11 22 THIS DIAGRAM IS TO SHOW THE MAJOR POWER SYSTEM COMPONENTS - w ECTION - BOND#8 AWG CU TO D OUBLE LUG,POLARI Vmpp 33.94 VDC 33.94 VDC MAX.BRANCH 16 LOAD SIDE TAP CONN AND CIRCUITS.CONSULT EQUIPMENT MANUFACTURERS'INSTALLATION OPTION-NEC 705.12(B) (N)OR(E)GROUND ROD TAP,OR EQUIV. _D Impp 10.02 ADC 10.02 ADC OCPD RATING --- 20 A 20 A 30 A MANUALS PRIOR TO INSTALLATION AND COMMISSIONING. w€ **MODULE CHARACTERISTICS AT STC:CELL TEMPERATURE @ 25°C,SPECTRUM AM1.5,IRRADIANCE @ 1000 W/M2 LOAD SIDE TAP NOTES: y 1.CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING H WIRE&CONDUIT SCHEDULE CONNECTORS(IPC),OR EQUAL APPROVED COMPONENTS.MAKE,MODEL, a s MIN. PHASE CONDUCTOR NEUTRAL CONDUCTOR GROUND CONDUCTOR MAX. AND RATING OF INTERCONNECTION SHALL BE EQUAL TO,OR GREATER CIRCUIT TYPE CONDUIT SIZE SIZE SIZE CIRCUIT THAN,OUTPUT RATING OF PV SYSTEM. o SIZE QTY' (AWG) QTY. (AWG) QTY' (AWG) LENGTH 2.THE TOTAL AREA OF ALL CONDUCTORS,SPLICES,AND TAPS INSTALLED AT 1 AG 2/BRANCH #12 1 #6 BARE CU 86' ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75%OF THE CROSS-SECTIONAL AREA OF THE SPACE.NEC 312.8(2). -N 2 AC 3/4" 4 #10 --- --- 1 #8 143 3.LOAD SIDE TAPS TO FEEDERS SHALL COMPLY WITH NEC 705.12(B)(2)(1)& a G 3 AC 3/4" 2 #10 1 #10 1 #8 103' 1 705.12(B)(2)(2).. 3 1.CONDUCTOR&CONDUIT SIZES SHOWN ARE MINIMUM REQUIRED.LARGER SIZES MAY BE USED. TO UTILITY GRID 2.ALL CONDUCTORS SHALL BE THHN OR THWN-2 UNLESS OTHERWISE NOTED. 120/240 VAC 3.MAXIMUM CIRCUIT LENGTHS ARE BASED ON A MAXIMUM 2%VOLTAGE DROP. SINGLE PHASE 4. MICROINVERTER OUTPUT CIRCUIT MAY BE ROMEX,OF CABLE,ETC.IF RUN INDOORS.ADHERE TO WIRE SIZE SHOWN. BI-DIRECTIONAL t PROJECT: (TYP.)UTILITYKWH METER BRANCH NO.1 (11)MODULES&(11)MICROINVERTERS w 1 ENPHASE BUS 2 � CABLE TYP. Q (N) ENPHASE IQ COMBINER w w Q 80 A SOLAR COMBINER PANEL N v) V J + + + + -NEMA 3R ENCLOSURE Eu (E)150A MAIN p Z l0A/2P DISTRIBUTION Ll L2 N ('� w � ENPHASE - - - = L1 PANEL(V.I.F.) 150A MAIN w c' DROP f I f I CABLE 20A/2P BREAKER w = vw) c") SYSTEM Ll L2 FOR LOAD SIDE (V.I.F.) Oe V Lco 01 CONNECTION OPTION cal ENPHASE SEE ALTERNATE DETAIL / O O M TERMINATOR CAP L 30A 2P INSTALLED 20A/2P FACTORY L1 v) a N w ON END OF BRANCH NO.2 Ll (WIRED) V w LU LU iy j ENPHASE BUS (11)MODULES&(11)MICROINVERTERS L2 Q SOU CABLE SYSTEM ® N Q p � G L N n � 0 Z Q � w (N)JUNCTION BOX o O O ~ ~ 8 0 NEMA 3R ENCLOSURE - V V v) w_ w_ 00me a u LI a aaa L2 L2 NTTF w w ENPHASEIQ7 MICROINVERTER - - - - - - - - - - DATE 6/25/21 3g s 1 J J ow TYP. L L2 N DRAWN BY: JLL 1z1. G G J L CHECKED BY: JLA a Ll EXISTING EARTH GROUND w o #6 AWG SOLID CU EQUIPMENT GROUND CONDUCTOR CONT.RUN TO GROUND LUG ON (N)MIN.60 A AC DISCONNECT GROUNDING ELECTRODE REC.NO.# 29127 RACKING SYSTEM.ALL ROOFTOP COMPONENTS BONDED TO RACKING SYSTEM PER NEC (LOCKABLE PER NEC 705.22).LOCATE SCALE AS NOTED w OUTDOOR AS SHOWN ON SHEET SLR 1 690.43.MICROINVERTERS CONTAIN INTEGRATED EQUIPMENT GROUNDING. =€w DRAWING# 12 Pv.3 I I d SHEET 4 OF 5o `OU1S,AfpT , o i `\�� OEN '�iY Digitally signed :'� SF p - _ No.81305 by John L =* *= p2s Irz2 �p 0 0% STATE OF ;'4L, ;w=3 Antonelli �,`-'40MOP;..'G\�` W SS�ONAL Date: 2021.06.28 40 '00 o€� PV ELECTRICAL NOTES: p WARNING GENERAL 0 WARNING 1 88 ELECTRIC SHOCK HAZARD o s ELECTRIC SHOCK HAZARD �J�o 0 11 w 1.CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LOCAL AND NATIONAL CODE REQUIREMENTS. IF GROUND FAULT IS INDICATED SOLAR AC DISCONNECT �L/'J a s 2.OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES PRIOR TO THE COMMENCEMENT OF WORK. ALL NORMALLY GROUNDED TERMINALS ON THE LINE AND 3.EQUIPMENT SHALL BE40MALLED PER THE 2017 NATIONAL ELECTRICAL CODE(NEC),ALL APPLICABLE OR GOVERNING CODES,MANUFACTURER REQUIREMENTS, CONDUCTORS MAYBE LOAD SIDES MAY BE ENERGIZED Z titAND PER THE GOVERNING UTILITY COMPANY. IN THE OPEN POSITION z z E A.METALLIC CONDUIT OR TYPE MC METAL CLAD CABLE SHALL BE USED WITHIN THE BUILDING FOOTPRINT PER NEC 2017 690.31(G). UNGROUNDED AND ENERGIZED WIRING&CONNECTIONS REQ'D BY:NEC 690.41(B) 1 REQ'D BY:NEC 690.4(B) 2 REQ'D BY:NEC 690.13(B) 3 o APPLY TO: APPLY TO: APPLY TO:DISCONNECTS,AC w€ 1.ALL CONDUCTORS SHALL BE COPPER AND ARE SIZED BASED ON NEC 2017 310. INVERTER(S),IF NOT APPLIED BY AC DISCONNECT SWITCHES COMBINER PANELS,OTHER MEANS OF m 2.TO PREVENT AN INCREASE IN AC VOLTAGE LEVEL AND AVOID ANY NUISANCE FAULTS,IT IS RECOMMENDED TO SIZE CONDUCTOR FOR A TOTAL VOLTAGE MANUFACTURER PV SYSTEM DISCONNECTION DROP OF 2%OR LESS PER INVERTER MANUFACTURER. 3.ALL EQUIPMENT SHALL BE LISTED PER NEC 2017 690.4(B). a s A.THE TOTAL AREA OF ALL CONDUCTORS,SPLICES,AND TAPS INSTALLED AT ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75%OF THE CROSS-SECTIONAL AREA OF THE SPACE.NEC 312.8(A)(2). A.INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12. WARNING o p 5.FOR LOAD SIDE CONNECTION:GRID-INTERACTIVE PV SYSTEM CURRENT PLUS MAIN BREAKER RATING MUST BE LESS THAN,OR EQUAL TO,120%OF MAIN w SERVICE BUS RATING AND BREAKERS MUST BE MOUNTED AT OPPOSITE END OF MAIN BREAKER PER NEC 705.12(B)(2)(3)(b).IF EXISTING EQUIPMENT DOES NOT DUAL POWER SUPPLY RAPID SHUTDOWNH• � DISCONNECT � Y =s ALLOW FOR THIS A SUPPLY SIDE CONNECTION MAY BE USED PER NEC 705.12(A). a G 6.FOR SUPPLY SIDE CONNECTION:CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS(IPC),OR EQUAL APPROVED COMPONENTS. SOURCES:UTILITY GRID AND PV VOLTAGE:240 VAC g 3 MAKE,MODEL,AND RATING OF INTERCONNECTION SHALL BE EQUAL TO,OR GREATER THAN,OUTPUT RATING OF PV SYSTEM. SOLAR ELECTRIC SYSTEM 7.ALL OVERCURRENT PROTECTION DEVICES ARE SIZED PER NEC 2017 240.4(B)&210.19(A)(1). 8.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC 2017 300.6(C)(1)AND 310.1 DID). a 9.SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER NEC 690.56(C). REQ'D BY:NEC 705.12(B)(3) REQ'D BY:NEC 690.56(C)(3) 5 REQ'D BY:NEC 690.54 6 GROUNDING&BONDING APPLY TO: APPLY TO: APPLY TO: ANY/ALL ELECTRICAL PANELS CONNECTED PV SYSTEM MAIN AC DISCONNECT PV SYSTEM MAIN AC DISCONNECT TO MULTIPLE POWER SOURCES 1.THE ENTIRE ARRAY IS BONDED ACCORDING TO(NEC 690.46-250.120 PARAGRAPH(C).THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG USING #6 BARE COPPER WIRE OR#8 THWN-2 COPPER WIRE. PROJECT: 2.EACH MODULE IS BONDED TO THE MOUNTING SYSTEM USING BONDING CLAMPS.MOUNTING SYSTEM COMPLIES WITH UL 2703. 3.NEUTRAL A.EQUIPMENT GROUNDING CONDUCTORD EQUIPMENT GROUNDING GROUNDING 0 DUCTOR ISCON ECTTED TTO A GROUNDING ELECTRO E SY(STEM PER NEC 250.54. WARNING A R N I N G 5.AC SYSTEM GROUNDING ELECTRODE CONDUCTOR(GEC)SHALL BE A MINIMUM SIZE#8 AWG WHEN INSULATED,#6 AWG IF BARE COPPER. THIS EQUIPMENT IS FED BY MULTIPLE > 6.EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 2017 690.45,250.120(C),AND 250.122&BE A MINIMUM OF#10 AWG WHEN SOURCES.TOTAL RATING OF ALL A CAUTION A RC FLASH HAZARD a NOT EXPOSED TO DAMAGE,AND#6 AWG SHALL BE USED WHEN EXPOSED TO DAMAGE. DO NOT INSTALL ADDITIONAL 7APAPROPRIATE PPE REQUIRED. w Q OVERCURRENT DEVICES,EXCLUDING LOADS IN THIS PANEL AILURE TO COMPLY CANVLABELING MAIN SUPPLY OCPD,SHALL NOTSULT IN INJURY OR DEATH. ED r Z 1.ALL WARNING SIGN(S)OR LABEL(S)SHALL COMPLY WITH 2O17 NEC ARTICLE 110.21(B). EXCEED AMPACITY OF BUSBAR. REFER TO NFPA 70E. 2 2.LABEL WARNINGS SHALL ADEQUATELY WARN OF THE HAZARD.LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT,AND LABELS REQUIRED SHALL BE L REQ'D SUITABLE FOR THE ENVIRONMENT. 'D BY:NEC 705.12(B)(2)(3)(c) �� REQ'D BY:NEC 690.4(B) �� REQ'D BY:NEC 110.16,NFPA 70E w ~ 3.PV POWER CIRCUIT LABELS SHALL APPEAR ON EVERY SECTION OF THE WIRING SYSTEM THAT IS SEPARATED BY ENCLOSURES,WALLS,PARTITIONS,CEILINGS,OR o �9� w a] tw cM APPLY TO: APPLY TO: APPLY TO: V ap FLOORS. AC COMBINER PANEL AC COMBINER PANEL AC COMBINER PANEL,MAIN SERVICE DISCONNECT < O 4.PER NEC 690.13,PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN "IT POSITION.SIGN SHALL READ"WARNING-ELECTRIC SHOCK HAZARD-DO NOT TOUCH TERMINALS". O CieM Lu 5.PER NEC 2017 705.10,PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. V a N u � LU '�' MICROINVERTER SYSTEMS i WARNING a o 1.SYSTEM IS CONSIDERED AN AC MODULE SYSTEM.NO DC CONDUCTORS ARE PRESENT IN CONDUIT,COMBINER,JUNCTION BOX,DISCONNECT.AND COMPLIES POWER SOURCE O� WITH NEC 2017 690.6-NO DC DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. OUTPUT CONNECTION SIGNAGE REQUIREMENTS I O w w s 2.NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE SYSTEM,NEC 690.13,690.6. PHOTOVOLTAIC • • 1.)RED BACKGROUND W/WHITE LETTERING,OR: 0 mea 3.WHERE APPLICABLE:INTERCONNECTION SHALL COMPLY WITH NEC 2017 705.12(A)AS PERMITTED BY NEC 230.82(6). DO NOT RELOCATE 2.)WHITE BACKGROUND W/BLACK LETTERING = a O 0w A.CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUIT PER NEC 2017 690.6. a a 8 LETTER HEIGHT 3.)MIN.3 a a 5.ALL GROUNDING SHALL COMPLY WITH NEC 2017 690.47(A)IN THAT THE AC MODULES WILL COMPLY WITH NEC 250.64. OVERCURRENT DEVICE / w 6.MICROINVERTER BUS CABLE SYSTEM MUST BE A MINIMUM OF 2 IN.ABOVE THE ROOF SURFACE. A.)ALL CAPITAL LETTERS 5.)ARIAL OR SIMILAR FONT DATE 6/25/21 o w REQ'D BY:NEC NEC 705.12(15)(2)(3)(b) REQ'D BY:NEC 690.31 11 6.)WEATHER RESISTANT MATERIAL,PER UL 969 DRAWN BY: JLL APPLY TO: APPLY TO: CHECKED BY: JLA s o ALL BACKFED CIRCUIT BREAKER(S) JUNCTION BOXES,RACEWAYS,CABLE TRAYS, CONDUIT BODIES WITH AVAILABLE OPENINGS, REC.N0.# 29127 p EVERY 10',WITHIN V OF TURNS/PENETRATIONS SOLAR PV SYSTEM EQUIPPED SCALE AS NOTED H WITH RAPID SHUTDOWN DRAWING# TURN RAPID SHUTDOWN SWITCH TO THE"OFF" sovaeac zi PVA yPOSITION TO SHUT P°"^"� o€lt DOWN PV SYSTEM AND 3 REDUCE SHOCK HAZARD SHEET 5 OF 5 o IN THE ARRAY ` �.......... ..... Digitally signed .R$�;•'1,\CENSE''•; No.aisos John L W`REQ'D BY:NEC 690.56(C)(1)(a) by Jo _ `• = p�s APPLY TO: - y PV SYSTEM MAIN AC DISCONNECT A n to n e I I i '. :' w i O�•. STATE OF N W Date: �"7,sIoya,1.�? h-7R el:icemne:bee""wm:Am""eu eAed 11lly:lereeena 'Sze aemee byfob ve":m¢a a Dlgaal Sigfut"re a"ee"te.v""teecop1e '12:00:26 -04'00 =nl:mwree"fare""oT aeree:ie eaam ealeaanticM1esi ' uatbeverifieeon anyelearonic<opiea.