Loading...
HomeMy WebLinkAboutAPPROVED ENERGY CALC & MANUAL J - 12 SAN ROBERTO FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST.LUCIE COUNTY Design Location: FL, Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Type$1442.0 sgft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1250.00 ft2 b. Frame-Wood,Adjacent R=11.0 192.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? Yes 11.Ceiling Types (1476.0 soft.) Insulation Area a.Under Attic(Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade(ft2) 1446 b. Knee Wall(Vented) R=19.0 30.00 ft2 Conditioned floor area below grade(ft2) 0 c.NIA R= ft' 7. Windows(141.3 soft.) Description Area 12. Ducts R fit' a. U-Factor: Sgl, U=1.04 101.25 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 175 SHGC: SHGC=0.29 b. U-Factor. Sgl,U=1.11 40.00 ft2 13.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a.Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. 14.Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.284 a. Electric Heat Pump 34.8 HSPF:6.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15.Hot water systems SHGC(AVG): N/A a. Electric Cap:50 gallons 9. Floor Types (1445.5 sgft.) Insulation Area EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features b.NIA R= ft2 None c.NIA R= ft2 16.Credits None Glass/Floor Area: 0.098 Total Proposed Modified Loads: 44.57 PASS Total Baseline Loads: 45.19 I hereby certify that the plans and specifications covered by Review of the plans and �f-tRE S7,,g� this calculation are in compliance with the Florida Energy specifications covered by this �5+ ','Npc Code. calculation indicates compliance y'� I���` with the Florida Energy Code. PREPAR ID Y Before construction is completed cQn DATE: -1�'202 this building will be inspected for W. compliance with Section 553.908 I hereby certify that this building,as desiaDWmis in com liance Florida Statutes. with the Florida Energy Code f+0 we OWNER/AGFNI \ \ BUILDING OFFICIAL: DATE: \d DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 1/12/2021 12:02 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot# Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: ST.LUCIE COUNTY Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Detached FL, New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5 k Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiI ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio BEDROOM 52 ft 0 301 ft' ___ 0 1 0 2 Slab-On-Grade Edge lnsulatio WIC 1ft 0 63 ft- ___ 0 1 0 3 Slab-On-Grade Edge lnsulatio M.BATH 8 ft 0 56 ftz __ 0 1 0 4 Slab-On-Grade Edge lnsulatio KITCHEN 1 ft 0 192 ft' ____ 0 1 0 5 Slab-On-Grade Edge lnsulatio BATH 5 ft 0 45 ft' 0 1 0 6 Slab-On-Grade Edge lnsulatio BEDROOM 2 32.2 It 0 203.5 ft- -_ 0 1 0 7 Slab-On-Grade Edge lnsulatio ENTRY 711 0 55 ft' ___ 0 1 0 1/12/2021 12:02 PM EnergyGaugeg)USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 88Iab-On-Grade Edge Insulatio LAUNDRY Eft 0 42 fP - 0 1 0 9 Slab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 112 __ 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 112 Light N 0.6 No 0.9 No 0 18.4 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) BEDROOM 30 Blown Sol ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood _ 3 Under Attic(Vented) M.BATH 30 Blown 56 ft= 0.1 Wood 4 Under Attic(Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic(Vented) ENTRY 30 Blown 55 ft2 0.1 Wood _ 8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic(Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood 10 Knee Wall(Vented) GREAT/DINING 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 NE=>SW Exterior Concrete Block-Int InsuBEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 .2 SW=>NE Exterior Concrete Block-Int InsuBEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 3 NW=>SE Exterior Concrete Block-Int InsIBEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 _4 SW=>NE Exterior Concrete Block-Int Insul M.BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 5 NE=>SW Exterior Concrete Block-Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _6 NE=>SW Exterior Concrete Block-Int InsEIEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 7 SE=>NW Exterior Concrete Block-Int InsBIEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 8 S=>N Exterior Concrete Block-Int InsBEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 _ 9 SW=>NE Exterior Concrete Block-Int InsBEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block-Int Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 11 SW=>NE Exterior Concrete Block-Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0A 0 12 SW=>NE Exterior Concrete Block-Int InsuLAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 13 NE=>SW Exterior Concrete Block-Int InstGREAT/DINI 4.1 26 0 8 0 208.0 f12 0 0 0.4 0 14 NW=>SE Exterior Concrete Block-Int InsGREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 1/12/2021 12:02 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 15 N=>S Garage Frame-Wood KITCHEN 11 24 8 192.0 it- 0.23 0.4 0 DOORS # Omt Door Type Space Stones U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.04 0.29 Y 32.9 ft- 1 it 0 in 1 ft 5 in Drapes/blinds Exterior 5 2 SW=>NE 4 Metal Low-E Single Yes 1.04 0.29 Y 6.9 ft' 1 it 0 in 1 it 5 in None None 3 SE=>NW 7 Metal Low-E Single Yes 1.04 0.29 Y 24.0 f1 6 It 0 in 1 R 5 in None None 4 NE=>SW 13 Metal Low-E Single Yes 1.04 0.29 Y 37.5 fN 1 ft 0 in 1 It 5 in None None 5 NW=>SE14 Metal Low-E Single Yes 1.11 0.27 Y 40.0 ft' 8 ft 0 in 1 it 5 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 315ft' 315 ft' 24it 8it 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.04 139.01 .1263 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitt Split Singl SEER:15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None 1/12/2021 12:02 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cart # Company Name System Model# Collector Model# Area Volume FEF None None ft- DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 175 ft= Attic 65 ft- Default Leakage Atfic (Default) (Default) 1 1 TEMPERATURES Programabl[e T7hermosta[ft:]1N f ]1 ] Ceiling Fans:fX1 [7C� fX1 00 Oct Nov Dee Heating IX1 Jan H Feb lxJ Mar E ]Apr L 1 My [ I Jun [ ]Jul i 1 Auf ]Sep LJ OctOct Nov Dec Dec— Thermostat Venting [I ]1 Jan [I ]1 Feb [[�X1]Mar Ixl l 1 [ I Jun I 1 Jul [ ]Aug I 1 Sep lxl Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Coding(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(81bs/sq.ft. 0 ft- 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 lbs/sq.ft. ft' ft 0.3 M.BATH Defaui48 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(81bs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 lbs/s .ft. ft' ft 0.3 GREATIDINING 1/12/2021 12:02 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 5 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number. Y U Owner. WYNNE BUILDING CROP Jurisdiction: ST.LUCIE COUNTY = Design Location: FL.Fort Pierce o COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unwanted crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall P�Pnrl behind piping And wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a.In addition,inspection of log walls shall be in accordance with the provisions of ICCA00. 1/12/2021 12:02 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index,the more efficient the home. , FT. PIERCE, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1250.00 fN b.Frame-Wood,Adjacent R=11.0 192.00 ft 3. Number of units,if multiple family 1 c.WA R= ft' 4. Number of Bedrooms 2 d.N/A R= ft- 5. Is this a worst case? Yes 11.Ceiling Type and insulation level Insulation Area a.Under Attic(Vented) R=30.0 1446.00 ft- 6. Conditioned floor area(ft') 1446 b.Knee Wall(Vented) R=19.0 30.00 ft' 7. Windows' Description Area c.N/A R= ft' a. U-Factor. Sgl,U=1.04 101.25 ft' 12.Ducts,location&insulation level R ft' a.Sup:Attic,Rat:Attic,AH:Attic 6 175 SHGC: SHGC=0.29 b. U-Factor. SgI,U=1.11 40.00 ft' SHGC: SHGC=0.27 13.Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft' a.Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: WA ft' SHGC: 14.Heating systems kBtWhr Efficiency a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 8. Skylights Description Area 15.Hot water systems a. U-Factor(AVG): N/A ft2 a.Electric Cap:50 gallons EF:0.97 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1445.50 ft' Credits(Performance method) None b.N/A R= ft' c.N/A R= ft= I certify that this home has complied with the Florida Energy Efficiency Code for Building -1116 Construction through the above energy saving features which will be installed(or exceeded) ti4F1� in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant fe ,,,,,� Builder Signature: Date: Address of New Home:, gsa n \ `bAp City/FL Zip:�� �'CQ , f �DD;yE Sg � *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 12:02 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1 Project Summary o te wr�ghtsoft1 Entire House By. QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Prom:772466-6799 Fax 772466-6796 Email:QUICKCALCS@OL.COM Project Information For. WYNNE DEVELOPMENT CARLTON III,FT.PIERCE,FL Notes: Design Information Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19691 Btuh Structure 16785 Btuh Duds 5900 Btuh Duds 8919 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25591 Btuh Use manufacturers data n Rate/swingg multipplier 0.95 Infiltration Equipment sensible load 24418 Bhuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2065 Btuh Ducts 2429 Btuh Central vent(0 cfm) 0 Btuh Heatingg Coolingg (none) Area(ftz) 1602 1602 Equipment latent load 4493 Btuh Volume(fta) 14827 14827 Airchanges/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 28912 Btuh Equiv.AVF(chn) 94 49 Req.total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carder Make Cartier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A 030 Cond 25HBC53W030 AHRI ref 7914585 Coil FX4DN(B,F)037 Efficiency 8.5 HSPF Efiaency 7914585 12.0 EER,15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh@47-F Latent000ling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual air flow 1160 dm Actual air flow 1160 cfm Air flow factor 0.045 dm/Btuh Air flow factor 0.045 cfir\Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point=34 OF Backup: Input=7kW, Output=23009 Btuh,100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. ? r�9ti iti' 2021-,Ian1212D4:36 r E Gg N CARLT rsa1 p Calc.021 RSU08101 f•..E.R ...ram\Wngl'�oR FNAGiWYNNE-THE GRAND CARLiONtup GIc=MIB Fror¢D@orfaces N Page wrightsoft° Right-J®Worksheet '0b: Entire House Data: QUICK CALCS, INC. ay 317 ST.LUCE LN.,Fr.PIERCE,FL 34946 Phore:772466-6799 Fa 72466-6796 Email:OU1CKCALCS@IOL.COM 1 Room name Enfire Houma BEDROOM 2 ENlosed xsll 1762 It 41D ft 3 Room height 93 ft d 81) ft teaNmol 4 Room dhnensons 14D x 18.0 It 5 Room r 16015 1F 2520 IF Ty Construction U-lalue Or HTM Area (IF) Load Arm (fF) load number (BWh4F-`F) (BWl14F) or pedmeer (it) (BWh) or perimeter (ft) (Bu1) Heat Cool Gross N/P/S Heat Cod G. WP/S Heat Cool 6 W 134-00s 0.143 re 4A0 2S5 551 513 2055 1306 72 72 288 183 -1Actan - 1270 re 3S56 7OA3 38 0 1344 2562 0 - 0 -0 D Vtl 13A4as 0.143 m 4A0 255 120 87 348 221 0 0 0 0 L�DG 1Ac1an 1270 se 3556 70.95 20 0 711 1419 0 0 0 0 11 11D0 0390 se 1092 1131 21 21 229 238 0 0 0 0 W 13A4= D.143 s 4.OD 255 34 34 136 86 0 0 0 0 V+1 13AA= 0.143 eH 4.00 255 416 390 1562 993 144 144 577 367 I�—GG 1Aclom 1270 sw 35.56 70.95 6 0 213 426 0 0 0 0 tArdom 1270 err 35.56 7095 20 0 711 1419 0 0 0 0 13A4ors 0.143 nw 4A0 255 352 298 1151 732 112 88 354 225 IA-dom- 1270 Itw 3556 4624 12 0 415 528 12 0 416 528 1Aclam 12A) -riw 35M 4524 12 0 427 543 12- - -0 427 543 4A5-2and 0.770 rw 2156 36.90 41 0 880 1505 0 0 0 - 0 P 12C-Ow 0A91 - 255 120 12D 120 3D6 154 0 0 0 0 C 16A-30md 0.032 090 2.32 1602 1602 1435 3715 252 252 226- 585 F 22A-trrl 0989 - 27.69 0.00 1602 176 4878 0 252 41 1135 0 6 c)AEDe rsim 23 197 Ernelope loss(gain 16802 15970 3421 2627 12 a) WfilhAw 2890 815 640 180 b) Roornwrdatlon 0 0 0 0 13 Internal gains O=pan6@ 230 0 0 0 0 Applomestuhu 0 0 Subbtal(lines6b i3) 19691 16785 4061 2807 Le adarnalload 0 0 0 0 Le transfer 0 0 0 0 Redisfibufion 0 0 0 0 14 SubinN 19691 16785 4061 28117 15 Dudloads 30% 53% 5900 8919 30°k 53% 1217 1491 Total room bad 25591 25704 5278 4298 Air required(cfm) 1160 116D 239 194 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. w i RigHSuteOLri rsa1201919.021RSU08101 2021-erv121204.36 A _.r61WdgNsoft FNACIWYNNE-THEGRANDCARLION.np Calc=M18 Frond DoorfacesN Pagel wrightsoft° Right-A)Worksheet Jab. Entire House Date: By. QUICK CALCS, INC. 317 ST.LUCIE LN.,FL PIERCE R.34946 Prow M-466-6799 17> 772466E796 Email:QU1CKCALCS@AOL.COM 1 Room name WIC MASTER BATH 2 Bposedvall 0 ft 17.0 ft 3 Room height 80 ft heat(=1 8.0 ft heaVmol 4 Raom dimensions 7.0 x 9D ft 70 x 17.0 ft 5 Room area 63.0 T 119.0 fF Ty Construdion U-vd w Or HTM Area (`IF) Load Area (H) Load number (BWh4F-°F) (BWh45 or perimeter M (BWh) or perimeter M (BWh) Heat Cod G o NIPS Heat Cool Gros NIPS Heat Cad 6 w 13A4= 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 L—C 1ACIom 1270 w 3556 70.43 0 0 0 0 0 0 0 0 -13A4= 0.143 s 400 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 se, 3556 7025 0 0 0 0 0 0 0 0 ti 11130 0390 se 10.92 1131 0 0 0 0 0 0 0 0 w 13AAM 0.143 s 400 2.55 0 0 0 0 0 0 0 0 13A4as 0.143 sw 4.00 2.55 0 0 0 0 136 130 521 331 1Aclan 1270 sw 3556 70.95 0 0 0 0 6 0 213 426 1Ac1am 1270 sw 3555 70.95 0 0 0 0 0 0 0 0 1344as 0.143 w 4.00 255 0 0 0 0 0 0 0 0 IAclom- 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 1Ac1om 1270 rw 35M 4624 0 0 0 0 0 0 0 0 4A5-2omd 0.770 my 21S6 36.90 0 0 0 0 0 0 0 0 P 12C-0m 0091 256 128 0 0 0 0 0 0 0 0 C 16A.30md 0.032 - 090 232 63 63 66 146 119 119 107 276 F 22A-WI 0.989 - 27.E 0.00 63 0 0 0 119 17 471 0 6 c)AED=ursim -13 55 Emelopelosl9ain 56 133 1311 1087 12 a) Infiltration 0 0 255 75 b) Roomlerltilation 0 0 0 0 13 Intemal gains O=pan5@ 230 0 0 0 0 Applianoesrotller 0 0 Subtotal(lines6lo 13) 56 133 1577 1162 Lemexlemal load 0 0 0 0 Lestansfer 0 0 0 0 Redisibulm 0 0 0 0 14 Subtotal 56 133 1577 1162 15 Dudloads I 30-A 53% 17 71 30% 53% 472 618 Total mom load 73 204 2049 1780 AirmWired(dm) 3 9 93 80 Calculations approved bvACCAto meet all requirements of Manual J ft Ed. ,� mgjm .mgre'. 2021. 12120436 MgftSut Uri rs.1201919021 RSW8101 Page _rbiWrtgttsoft HUAQWYNNE-THE GRAND CARLTONnp Cale=MlB FrortDoorfams N ghtsofr Right-J®Worksheet Job'.Date: Entire House By. QUICK CALCS, INC. 317ST.LLr4ELN-FLPIERCE,FL34946Phore:M-4656799Fax:772-0665796 Emit:OUICKCALCS@AOL.COM 1 Room name KITCHEN BATH 2 Bposedxall I 0 ft 5A R 3 Room height 8D ft heaVood 9.4 ft heatlmol 4 Room dmentions 1.0 x 192-0 ft 9A x 5.0 ft 5 Roornwea 192D F 45A 1F Ty Construction U-vdlue or HTM Area (IF) Load Area (T) Load number (Bhd*L*9 (BWhHF) or perimeter (ft) (BWh) or perimeter (ft) (Btuh) Heat Cool Cans NUPS Heat Cool Gros NIPS Heat Cool 6 V�/ 13A4as 0.143 m 4A0 255 0 0 0 0 47 47 188 120 L—C 1Aclom 1270 m 3556 70A3 0 0 0 0 0 0 0 0 -13A4as 0.143 se 4.00 255 0 0 0 0 0 0 0 0 1Aclom 1270 se 3556 70.95 0 0 0 0 0 0 0 0 11 11DO 0390 se 1082 1131 0 0 0 0 0 0 0 0 W 13A4ars 0.143 s 4A0 2.55 0 0 0 0 0 - 0 0 0 13AAM 0.143 w 4.00 255 0 0 0 0 0 0 0 0 1Ac1om 1270 w 35S6 70.95 0 0 0 0 0 0 0 0 1Ac1om 1270 w 3556 70.95 0 0 0 0 0 0 0 0 13A-4oc; 0.143 nw 4.00 Z55 0 0 0 0 0 0 0 0 IA-dom 1270 rw+ 35M 4524 0 0 0 0 - 0 0 0 - 0 1Actom 12M rw+ 35W 4524 0 0 0 0 - 0- 0 0 0 4A5.2and 0.770 mN 21.56 36,90 0 0 0 0 0 0 0 - 0 P 12C Ow OA91 255 128 0 0 0 0 0 0 0 0 c 16A30md OA32 - 0.90 232 192 192 172 445 45 45 40 104 F 22AAPI 0889 - 27B9 0.00 192 0 0 0 45 5 138 0 6 c)AED ewfton 39 -22 Emelope bs/gain 172 406 367 202 12 a) Infiltration 0 0 92 26 b) Roomvenhlation 0 0 0 0 13 Intemel gaire: 0mtpan5@ 230 0 0 0 0 Applies cs/olher 0 0 Subbtel(lines6to13) 172 406 459 228 LesseAemal loaf 0 0 0 0 Lestrander 0 0 0 0 RedistibOton 0 0 0 0 14 SubtYal 172 406 4% 2M 15 Ductbads 30% M% 52 216 30% 539/6 137 121 Total mom bad 224 622 596 349 Airrequired(dm) 10 28 27 16 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. '""' ¢ -'fi-�^�-ft�+�` 2021JarM212D426 A-&K " RigitSdte®Uri..120191SD21RSU08101 pap -xLAWnghR ftWAC1WYNNE-THE GRANOCAROOWW Calc=NW FroNDoorfamN wrigwsw Right-JO Worksheet Job: Entire House Date; By. QUICK CALCS, INC. 317ST.LUCIELN-FF..PIERgE.FL34946PImm:772A66-6799 Fac772AW-ff 6 Emil:QUICKCALC5@AOL.COM 1 Room rlame BEDROOM2 ENTRY 2 E>posedwall - I 302 it 60 ft 3 Room height 8D it heaticool 8D it heat/mol 4 Room dimensans ID x 1905 It 6A x 10.0 it 5 Room area 190.5 a- 60.0 fF Ty Corstrucfion Ll-value Or HTM Area (ft0 Load Area Load number (BWh4t'-°F) (Swilln or perimeter (it) (BWh) or perimeter (it) @bh) Heat Cool Gross NIPS Heat Cod Gross NIPS Heat Cool 6 lM 13A-0as 0.143 ne 4.00 2.55 120 120 480 305 0 0 0 0 L--G 1Ac1om 1270 ne 35.66 70.43 0 0 0 0 0 0 0 0 YLS 13A4ors 0.143 se 400 2.55 80 60 240 153 48 27 108 69 1Ac1om 1270 se 3556 7025 20 0 711 1419 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 21 21 229 238 w 13Ar4ocs 0-143 s 4DO 2.55 34 34 136 86 0 0 0 - 0 13A4o 0.143 w 4DO 2-95 8 8 32 2D 0 0 0 0 1Ac1om 1270 w 3556 70.95 0 0 0 0 0 0 0 0 1Ac1om 1270 w 3556 7025 0 0 0 0 0 0 0 0 la44ccs 0.143 rw 4.00 255 0 0 0 0 0 0 0 0 1Acicm 1270 nw 3556 4524 0 0 0 0 0 0 0 0 1A-dw 1270 rw 3556 4524 0 0 0 0 0 0 0 0 4A5-2ornd 0.770 rw - 21.66 36.90 0 0 0 0 0 0 - 0 0 P 12C-Oav 0A91 - 2.55 128 0 0 0 0 0 0 0 0 c 16430md 0.032 - 020 2.32 191 191 171 442 60 60 54 139 F 22A-ml 0.989 - 27b5 0.00 191 30 835 0 60 6 166 0 6 c)AED e#L m 209 -41 ErNebpe bsslgain 2506 2635 557 404 12 a) h Wafion 472 133 94 26 b) Roomlentilation 1 0 0 1 0 0 13 Internal gain Oovpants@ 230 0 0 0 0 Appliancesb1her 0 0 Subb41(lir a to 13) 3078 2768 651 430 Lesse)ftmalload 0 0 0 0 Lestransfer 0 0 0 0 Redistribution 0 0 0 0 14 Sublo41 3078 2768 651 430 15 Ductbads 30% 53% 922 1471 30% 531. 195 229 Told room bad 40M 4239 846 659 Air regdred(dm) 181 191 38 30 Calculations approved byACCAto meet all requirements of Manual J Sth Ed. c 20214I 12120426 RigRAND GkRversa1P Calc.021 Root D1 Page4 .-rh1WngNsoflHVAgWYNNE-hIE GRAND C4RLlONnp Caic=N118 frortDoorfaces N wrightsoft Right-M)Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST LUCIE UN,FT PIERCE,FL 34946 PIure:772466-6799 F.772466-6796 Email:QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREATiDINING 2 E)pomd Hall 6.0 It 46.0 ft 3 Room height 8.0 ft heatlmol 12.0 it heaV000l 4 Room dimensons 7.0 x 6.0 It 1.0 x 488.0 It 5 Roomarea 42.0 iF 488.0 fF Ty Consturdon U-value Or HTM Area Load (T) Load number (BWhfiR-°F) (BbihM) or penm�e� (t) (BWh) oorperimeter (ft) (BWh) Heat Cool Gros NIPS Heat Cool Gross N/ S Heat Cool 6 W 13A4= 0.143 ne 4.00 2.55 0 0 0 0 312 274 1098 698 �G 1Actom 1270 ne 3556 70.43 0 0 0 0 38 0 1344 2662 13A4= 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1Aciom 1270 se 3556 70.95 0 0 0 0 0 0 0 0 11 D 11DO 0.390 se 1092 11.31 0 0 0 0 0 0 0 0 W 13A-0as 0.143 s 4D0 255 0 0 0 0 0 0 0 0 13A4ocs 0.143 sw 4D0 2.55 48 48 192 122 0 0 0 0 1Acrlom 1270 sw 35.56 70.95 0 0 0 0 0 0 0 0 1Aclom 1270 w 35,56 70.95 0 0 0 0 0 0 0 0 13A4ars 0.143 nw 4.00 2.55 0 0 0 0 240 199 798 507 tAclom 1270 nw 35M 4524 0 0 0 0 0 0 0 0 1Aclom 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 41 0 880 1505 p 12C-O w 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 42 42 38 97 488 488 437 1132 F 22A-tol 0989 - 27.69 0.00 42 6 166 0 488 46 1274 0 6 c)AEDe=rsion .22 -597 Envelope lossrgain 396 198 5830 5908 12 a) Infiltration 94 26 1077 304 b) RoornwnfiWon 0 0 0 0 13 Intemalgairs: O=pants@ 230 0 0 0 APPliances(other 0 0 Subttal(lines6to13) 490 224 6907 6212 Les e)demal load I 0 0 Lestamfer 0 0 0 0 0 0 Redistribufion I 0 0 0 0 14 Subtotal 490 224 6 15 DUCloads 30% 53% 147 719 30% 53% 2070 070 3301 3301 Total mom load 636 344 Air required(1m) 29 16 8407 9429 407 512 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed AGG+ '�'t wrl�~•--. � 2021-Jarn1212:04:36 I\ EGRA.NtCARL7rsal20tCalc= iRSortDo ...ris\WriglEofl M/ALYWYNNE-THE GRAND G4RLTON.rup Calc=MlB Front DOOrfaces N Page wrightsoft Right-J@ Worksheet jdx Entire House Date. QUICK CALCS, INC. By. 317 ST..LUCIE LN,Fr.PIERCE.FL 34946 Ptere:T72-466-6799 Fax 772-466-SM Erred:QUICKCP.LCS@AOLCOM 1 Room renre BEDROOM3 2 Fdwall 25.0 ft 3 Room height 8.0 ft heaNmol 4 Room dimensore 15D x 10D ft 5 Room area 15D.0 i6 Ty Caetrudicn U-Value Or HTM Area (W) Load Area Load rimber (BluhffL'n (BluhAn or pedm ter (ft) (Bluh) or perimeter Heat Cod Gros NIPS Heat Cool Gross WPIS Heat Cool 6 V 13A4= 0.143 ne 4.00 255 0 0 0 0 LC 1Aclm 1270 ne 36M 7OA3 0 0 0 0 13A4ocs 0.143 se 4-00 2.55 0 0 0 0 IA-dw 1270 se 3556 70.95 0 0 0 0 1'I 11DO 0390 se 10.92 1131 0 0 0 0 w 13A4= 0.143 s 4.00 2-95 0 0 0 0 4y 13A4o s 0.143 sH 4.00 2-55 6o 60 240 153 1Ac1am 1270 sv 3556 70aS 0 0 0 0 1A-dom 1270 sv 3556 7025 20 0 711 1419 W 13/Wars 0.1 nw 4A0 255 0 0 -0 0 IIL-----GGG 1Aclom 1270 nw 3556 4524 0 0 0 0 iAclom 1270 nw 35M 4524 0 0 0 0 4A5-2omd 0.770 nw 2156 36.90 0 0 0 0 P 12C-Ow OD91 255 128 120 120 306 154 C 16A30md 0.031 - 0.90 232 150 150 134 348 F 22MM 0869 - 2759 OAO 150 25 692 0 6 c)AEDelralrson 296 Ervelope los'gain 2084 2369 12 a) hfillation 156 44 b) RoomverAlafion 0 0 13 ht$ lgaaw Cowpants@ 230 0 0 Applianoe4other 0 SubhNal(fines61o13) 2240 2413 Leseldemal load 0 0 Lesirdn5er 0 0 RedLViribLdw 0 0 14 subhifal 2240 2413 15 Dudloads 30% 53% 671 1282 Total room load 2911 3695 Airrequired(olm) 132 167 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. " +mqR'" 2021Ja 1212A436 Arw ^^ RigHSute®Urivmi201919A21RSU08101 Page _.r6lWdgttift WAMYNNE-THE GRAND CARLIONnp Calc=92 Frort Doorfaoas:N