Loading...
HomeMy WebLinkAboutAPPROVED 20-0519.09 Fixed SentinalMIAMIDDADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.mianAdade.gov/buildine CGI Windows and Doors, Inc. 3780 W 104t' Street Hialeah, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "Sentinel 130" Aluminum Fixed Window — L.M.I. APPROVAL DOCUMENT: Drawing No. PW 130LMI-NOA, titled "`Sentinel' Series 130 Fixed Window - LM", sheets 1 through 7 of 7, dated 05/22/19, with revision A dated 05/07/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA# 19-0603.02 and consists of this page 1 and evidence pages E-1, E-2, E-3, E-4 and E-5, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 20-0519.09 Expiration Date: September 22, 2025 Approval Date: October 10, 2020 T8/31J20 Page 1 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 10-0510.13) 2. Drawing No. PW130LMI-NOA, titled "Sentinel 130 Alum Fixed Window (L.M.I.)(S.M.I.)", sheets 1 through 7 of 7, dated 05/22/19, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. (Submitted under NOA No.19-0603.02) B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 560 aluminum sliding glass door, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-19-8916, dated 04/10/19, signed and sealed by Idalmis Ortega, P.E. (Submitted under NOA No.19-0603.02) 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Water Resistance Test, per FBC, TAS 202-94 3) Small Missile Impact Test per FBC, TAS 201-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 130 and 410 aluminum fixed windows, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-19-8917, dated 04/09/19, signed and sealed by Idalmis Ortega, P.E. (Submitted under NOA No.19-0603.02) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7500 PVC fixed window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0413.03) Manuel Perez, P. Product Control E NOA No. 20 O519. Expiration Date: September ,4, 025 Approval Date: October 10, 2020 E-1 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED) B. TESTS (CONTINUED) 4. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7400 PVC project out window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0413.03) 5. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 238 aluminum fixed window, to qualify DuPont `Butacite" PVB interlayer, Duraseal(x and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No. 15-0413.03) 6. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Small Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a Sentinel 130 aluminum fixed window, prepared by Hurricane Test Laboratory, Test Report No. HTL 0080-0130-10, dated 03/30/10, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No.10-0510.13) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 6' Edition (2017), dated July 15, 2017, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.] 7--0918. 07) 2. Glazing complies with ASTM E1300-09. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) Manuel Perez, P.E. Product Control E r 1 NOA No. 20 0519.09 Expiration Date: September 2 Approval Date: October 10, 2020 E-2 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 12/28/17, expiring on 07/04/23. 2. Notice of Acceptance No. 17-1114.14 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/18/18, expiring on 07/08/19. 3. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 05/17/18, expiring on 12/11/23. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 6' Edition (2017), dated May 23, 2019, issued by manufacturer, signed and sealed by A. Lynn Miller, P.E. (Submitted under NOA No.19-0603.02) 2. Statement letter of no financial interest, dated May 23, 2019, issued by manufacturer, signed and sealed by A. Lynn Miller, P.E. (Submitted under NOA No.19-0603.02) 3. Proposal No. 19-0219 issued by the Product Control Section, dated March 13, 2019, signed by Ishaq Chanda, P.E. (Submitted under NOA No.19-0603.02) 4. Notification of Successor Engineer for manufacturer's NOA document per Section 61G15-27.001 of the Florida Administrative Code, notifying original engineer that the successor engineer is assuming full professional and legal responsibility for all engineering documents pertaining to this NOA, dated May 22, 2019, signed and sealed by A. Lynn Miller, P.E. (Submitted under NOA No.19-0603.02) 5. Laboratory compliance letter for Test Report No. HTL-0080-0103-10, issued by Hurricane Test Laboratory, LLC, dated March 30, 2010, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No.10-0510.13) 6. Test Proposal for the qualification of Butacite® PVB glass interlayer by Kuraray America, Inc., as well as Duraseal® and Super Spacer® Standard warm -edge flexible insulating glass spacers, dated December 16, 2014, issued by RER, Product Control Section, signed by Jaime Gascon, P.IKSqpervisor, Product n r ection. (Submitted under NOA No. 15-0413.03) Manuel Perez, P.E. Product Control EC51 r NOA No. 209ExpirationDate: September Approval Date: October 10, 2020 E-3 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED) G. OTHERS 1. Notice of Acceptance No. 17-0918.07, issued to CGI Windows and Doors, Inc. for their Series "Sentinel 130" Aluminum Fixed Window - L.M.I. approved on 11/22/17 and expiring on 09/22/20. 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. PW130LMI-NOA, titled "`Sentinel' Series 130 Fixed Window - LM", sheets 1 through 7 of 7, dated 05/22/19, with revision A dated 05/07/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per ASTM F588 and TAS 202-94 along with marked -up drawings and installation diagram of all PGT Industries, Inc. CGI Windows and Doors, Inc., representative units listed below and tested to qualify Dowsil 791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: PGT Industries, Inc. test specimens: FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E. CGI Windows and Doors Inc. test specimens: FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit 1 in proposal) FTL-20-2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal) FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal) FTL-20-2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal) all dated 08/24/20 and signed and sealed by Idalmis Ortega, RE Manuel Perez, P.E. Product Control E r ,I NO A No. 20 0519.09 Expiration Date: September , 2 Approval Date: October 10, 2020 E - 4 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED (CONTINUED) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 6' Edition (2017), dated 07/15/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E., updated to comply with FBC 7' Edition (2020), on 05/11/20 by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 18-0725.11 issued to Kuraray America, Inc. for their "Kuraray SentryGlas® Xtrafm (SGXTn Clear Glass Interlayer" dated 05/23/19, expiring on 05/23/24. 2. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 05/09/19, expiring on 07/08/24. 3. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 05/17/18, expiring on 12/11/23. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, of complying with FBC 6' Edition (2017), and FBC 7a' Edition (2020), dated May 07, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated May 07, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10, 2020, signed by Ishaq Chanda, P.E. G. OTHERS Notice of Acceptance No. 19-0603.02, issued to CGI Windows and Doors, Inc. for their Series "Sentinel 130" Aluminum Fixed Window - L.M.I. approved on 07/03/19 and expiring on 09/22/20. Manuel Perez, P.E: Product Control E r 1 NO A No. 20 519.09 Expiration Date: September , 2 Approval Date: October 10, 2020 E - 5 49" FLANGE WIDTH D.L. OPG. U) 6" MAX, mw r 18" MAX. ¢ a S R HORTU � CORNERS 'T" . SIDES ca e w 4Z4 Ci I �I u ci IL JI o ul a I1 1I r :zfa TYP. FLANGE & FLANGE FALSE MUNTINS (SURFACE ADAPTOR FRAME APPLIED) OPTIONAL_ 48" BUCK WIDTH D.L. OPG. TYP. EQUAL LEG FRAME 1,9. sbis" 18" MAX. _� 6" MAX. SHORTER HEAD/SILL SIDES CORNERS wiunnw wrnTu SERIES 130 SENTINEL ALUMINUM FIXED WINDOW -- LMI DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEET 2. APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF FIX./FIX. OR FIX. WDW. WITH OTHER MIAMI--DADE COUNTY APPROVED WINDOWS USING MIAMI—DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) & 2020 (7TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 1 BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON—METALLIC AND NON —COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017/2020 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL. 3 0 z w J o f 0 3 LLUJ PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0519.09 Expiration Date: 9/22/2025 By: ,..F Miam?made Produce rol 49" ANGE WIDTH D.L. OPG. z 'o sa 18" MAX. SHORTER SIDES WINDOW WIDTH W WIDTH I f s Lj z � TYPICAL ELEVATIONS ANCHOR SPACING SHOWN HEREIN APPLICABLE TO FLANGE AND FLUSH FRAMES, SEE SHEET 2 FOR FIN FRAMES. 96" BUCK HEIGHT D.L. OPG. �s a � 00 OIt le U- .--I m II LAM. GLASS INSULATING LAM.GLASS SMALL MISSILE IMPACT LARGE MISSILE IMPACT 6" MAX. I _ 17" MAX. CORNERS STRAIGHT SIDES WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH z w WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH z z f (� Js THESE WINDOWS ARE RATED FOR LARGE & SMALL MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED ALLOWABLE LOADS FOR ALTERNATE SHAPES AS SHOWN ABOVE OR SIMILAR CAN BE VERIFIED BY INSCRIBING PICTURE WINDOW SHAPE WITHIN SQUARE OR RECTANGLE AS SHOWN IN DOTTED LINES AND OBTAINING ALLOWABLE LOADS FROM THOSE SHAPES. rare: urawn ,ay: "SENTINEL" SERIES 130 FIXED WINDOW - LM AGK 0Windows R & boot & Doors twell� Description. Date: TYPICAL ELEVATIONS 0�/22119 11, S693-GSB � ax:3 559.659 Y.I: 305.fi93_fi590 Fox: 306.693.6692 Revision: Rev. 9y: Rev. Date: PREPARED BY LYNN MILLI ANCHOR TYPES, UPDATED TO FBC 2020 .�R 05/07/20 N VENICE, FL34275°RIVE Series/Model: Scale: Sheet: PW-130 LM NTS 1 OF 7 Drawing No. Rev: (941) 480-1600 PW130LMI-NOA A. REGISTRATION #29296 l,t;3lit,il,-•-- 0, Y 58705 ZfT Otu STA"E0F '�jirlllt'.t`` A. LYNN MILLER, P.E. P.E,#58705 TYPICAL ELEVATIONS ANCHOR SPACING SHOWN HEREIN APPLICABLE TO FIN FRAMES. 48" BUCK WIDTH Q.L. OPG, 6" MAX. 16" MAX. HEAD/SILL AZ STRAIGHT CORNERS SIDES 4 u u ir ii u%u L A TYP. FIN FRAME s h Ej Q 6" MAX. CORNERS DAYLITE OPENINGS- D.L.O. HEIGHT T BUCK HEIGHT - 3,00" D.L.D. WIDTH = BUCK WIDTH - 3.00" 16" MAX. STRAIGHT TYP. FIN FRAME SIDES LAM. GLASS INSULATING LAM.GLASS SMALL MISSILE IMPACT 48" 48" LARGE MISSILE IMPACT UCK WIDTH BUCK WIDTH D.L. OPG. D. L. 0 PG. 7S, N <cc W m mZ a �O cfl U S o m L J d© 1 I (0rv) S��FO W OE m W aof 10 O U 4- I� I� I� (D _p f? C9 { m L J FALSE MUNTINS / (SURFACE APPLIED)— L16" MAX. _ _ 6" MAX. 16" MAX. OPTIONAL STRAIGHT HEAD/SILL STRAIGHT SIDES CORNERS SIDES TYP. FIN FRAME TYP. FIN FRAME PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0519.09 Expiration Date: 9/22/2025 By:'� L�fGt Miam6ade Producf-Co vol ALTERNATE SHAPES AS SHOWN ON SHEET 1 ALSO AVAILABLE FOR FIN FRAMES Title. 11SENTINELI1 SERIES 130 FIXED WINDOW - LM Description. TYPICAL ELEVATIONT CONT. ytj1 �(ri Drown 6y: \",\ �",' � 1 �'(��'i `ff Impact Resistant F' AGK�.t",t l )Windows & Doors �J \JJ wee srRaxe-- Date: 3780 W. 104ih Street, Filaieah, FL 33016 05/22/1 g Tel: a05.69a.5590 1 Fax: 305.393.859Z ' Revision: Rev. 8y: Rev. Date: PREPARED BY LYNN MILLER f MINOR SHEET REFORMATTING. JR 105/07/20 1070 TECHNOLOGY DRIVE � Ia.i;_ OF �,�� ' N. VENICE, FL34275 Sevres/Model: ScaSheet: �D"lng"0 , Rev: (941) 480-1600 Tf ff � x � b'�j 4�; s PW-130 LM II 2 OF 7 PW130LIVI NOD A r r I i I'L s:'r' REGISTRATION #29296 A. LYNN MILLER, P.E. P.E.# 58705 DESIGN LOAD CAPACITY - PSF FLANGE DIMS. SUCK DIMS. GLASS TYPES 'C'&'C1' GLASS TYPES 'D'&'D1' WIDTH (W) LENGTH (L) WIDTH (W) LENGTH (L) EXT.(+) 1 NT,(-) EXT.(+) 1 NT.(-) 24" 30' 36" 42' 48' 54" 60" 61" 36" 23" 29' 35' 41" 47" 53" 59" 60' 35" 80,D 80.0 80.0 80.0 80,0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 90.0 80.0 80.0 80.0 130.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 24" 30" 36" 42" 48" S4" 60" 51" 48" 1 23" 29" 35" 41" 47" 53" 59" 60" 47" 80.0 80.0 80.0 80.0 80.0 80.0 00.0 90.0 80.0 B010 80.0 80.0 70.2 70.2 80.0 00.0 61.3 61.3 80.0 80.0 61.3 61.3 80.0 80.0 61.3 61.3 80.0 80.0 61.3 61.3 80.0 80.0 24` 30" 36' 42" 40" 54" 60" 61" 60„ 23" 29" 35" 41" 47" 53" 59" 60" 59" 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 70.2 70.2 80.0 80.0 61.3 61,3 8D.0 80.0 54.3 54.3 72.5 72.5 48.8 48.8 65.1 55.1 48.8 48.8 65.1 85.1 24" 30" 36" 42" 48' 54' 60" 61" 72„ 23" 29' 35' 41" 47" 53" 59" 60" 71„ 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 BO.D 80.0 80.0 80.0 70.2 70.2 B0,0 80.0 61.3 61.3 80.0 80.10 54.3 54.3 72.5 72.5 48.8 48.8 65.1 65.1 48.0 48,0 64.0 64.0 24' 30' 36' 42" 48" 54" 56" 84" 23" 29" 35" 41" 47" 53" 55" $3" 80.0 80.0 80.0 80.0 80.0 80.0 BD-0 80.0 78.2 78.2 80.0 80.D 70.0 70.0 80.0 80.D 61.3 61.3 80.0 80.0 54.3 54.3 72.5 72.5 52A 52.4 69.8 69.8 24" 30" 36" 42" 48" 49" 97" 23" 29" 35" 41" 47" 48" 96" 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 75.6 75.6 80.0 80.0 65.2 65.2 80.0 80.0 60.6 60.6 80.0 80.0 59.6 59.6 80.0 80.0 24" 30" 36" 42" 46" 102" 23" 29' 35' 41' 45- 101" 80.0 80.0 B0.0 80.0 80,0 80.0 80.0 80.0 74,6 74.6 B0.0 80.0 65.7 65.7 80.0 80.0 59.3 59.3 80.0 80.0 24" 30" 36" 42" 44" 108" 23" 29' 35" 41' 43' 107" 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 73.8 73.8 80.0 80.0 62.4 62.4 80.0 80.0 59.1 59.1 80.0 $0.0 DESIGN LOAD CAPACITY - PSF FLANGE DIMS. BUCK Dam. GLASS TYPES 'f,'&'Ci' GLAD TYPES 'D'&'Dl' WIDTH (W) LENGTH (L) WIDTH (W) LENGTH (L) EXT.(+) 1 NT.(-) EXT.(+•) 1 NT.(-) 24" 30" 36" 41" 114" 23" 29" 35' 4D" 113" 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 73.0 73.0 60.0 80.0 1 61,4 61.4 80.0 80.0 24" M. 36" 39" 120' 23' 29' 35" 38" 119" 80.0 80.0 80.0 80.0 90.0 00.0 80.0 80.0 72.4 72.4 80.0 80.0 65.9 65.9 60.0 80.0 24" 30" 36' 39" 121" 23" 29' 35" 38" 120" 80.0 80.0 80.0 80.0 80.0 80A 80.0 80.0 72,3 72.3 80.0 80.0 65.8 65.8 80.0 80.0 DIMS TYP BUCK DIMS FLANGE FRAME BUCK DIMS EQUAL LEG FRAME BUCK DIMS FIN FRAME 'LANGE DIMS BUCK DIMS - FLANGE ADAPTOR FRAME PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0519.09 Expiration Date: 9/2� 2/2025 By: iiGirGGP� Miam�yade Produc;k"C drol ANCHOR SPACING TO BE AS PER SHEETS 1 & 2 X" TYP. DESIGN LOAD CAPACITY - PSF FLANGE DW. BUCK DIMS. GLASS TYPES 'C'&'C1' GLASS TYPIiS 'D'&%1' WIDTH (W) LENGTH (L) WIDTH (W) LENGTH (L) EXT.(+) TNT.(-) EXT,(+) 1NIT. (--) 19-1/8" 26-1/2" 37' 48' 53--1/8' 61' 26" 18-1/8" 25-1/2" 36" 47" 52-1/8" 60" 25' 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80,0 80.0 19--1/8" 26-1/2" 37' 48" 53-1/8" 61 " 38-3/8" 16-1/8" 25-1/2' 36" 47" 52-1/8- 60" 37-3/8" 80.0 80.0 80.0 80.0. 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 77.1 77.1 80.0 80.0 77.1 77.1 80.0 80.0 77.1 77.1 80.0 80.0 19-1/8' 26-1/2" 37" 48" 53-1/8" 61' 75-1/4" 93-3/4" 50-5/8" 18-1/8- 25-1/2" 36" 47" 52-1/8" 60" 74-1/4" 92-3/4" 49-5/8" 80.0 80.0 80.0 80.0 80.0 60.0 80.0 80.0 80.0 80.0 80.0 80.0 61.3 51.3 80.0 80.0 58.0 58.0 77.4 77.4 58.0 58.0 7 ..4 77.4 58.0 58.0 77.4 77.4 58.0 58.0 76.5 76.5 19--1/8" 26•-1/2' 37" 48" 53-1/8" 61" 75-1/4" 63" 18-1/8" 25-1/2" 36" 47" 52-1/8" so" 74-1/4" 62" 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 60.0 80.0 80,0 80.0 61.3 61.3 8010 80.0 55.3 55.3 73.7 73.7 48.0 48.0 64.0 64.0 46.5 46.5 61.9 61.9 19--1/8" 26-1/2' 37" 48" 53-1/8" 61" 76" 18-1/8" 25-1/2" 36" 47' 52-1/8" 60" 75" 80.0 80.0 130.0 80.0 80.0 80.0 80.0 80.0 78.9 78.9 80.0 80.0 61.3 61.3 80.0 1313.0 55.3 55.3 73.7 73.7 48.0 48.0 64.0 64.0 NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISION DECLARATORY STATMENT DCA05-DEC--219 Title: "SENTINEL" SERIES 130 FIXED WINDOW - LM Description: DESIGN LOAD CHARTS Revision; NO CHANGES THIS SHEET. NOTE: WIDTH AND LENGTH DIMENSIONS CAN BE ORIENTED VERTICALLY OR HORIZONTALLY AS SHOWN ABOVE. AGK Impact Resistant Windows & doors WEW 8T11EiNQEI1- Dote: 05/22/19 Rev. 8y: Rev. Date. JR 05/07/20 Series/Modef; Scafe: Sheet: Drawing No. Rev: PW-130 LM NTS 3 OF 7 1 PW130LMI-NOA I A �„illlflll.. 3780 W. 704th Streel, Hla leah, FL 53013-yr T"t:305.593.5890 I F.:305.593A. Y w .. "PREPARED � Za 10 BY LYNN MILLER '- 1070 TECHNOLOGY DRIVE - STATE OF fj N, VEN ICE, FL34275 r� F/ 480-1600 (941) it illgisl� REGISTRATION #29295 A. LYNN MILLER, P.E. P.E.# 58705 .075" Saflex CP With PET Core By 'Eastman Chemical Co.' Interlayer_ Saflex CP With PET Core .090" Saflex Clear And Color Glass 'Eastman .075' By Eastman Chemical Co.' Interlayer By Chemical Co.' Interia er .090 Interlayer SentryGlas InterlayerSaflex Clear And Color Glass 'Eastman By 'Kuraray Americp, Inc.' By BynChemical Co.' Interlayer .090- Interlayer Trosifol PVB Interlayer 090 Interlayer 5entryGlas Interlayer By 'Kuraray America, Inc.' 3/16" HEAT By Kuraray America, Inc.' 3/16" ANN. STREN'D GLASS .090 Interlayer Trosifol PVB Interlayer 'Kuraray By America, Inc.' 0 GLASS 3/16" HEAT STREWD GLASS a_ Ld L,1 SIUCONE: z m 3/16" HEAT STREN'D GLASS z GE 1200, DOW CORNING 791, t�ir 51LICONE: d 1 899, 983 OR 995 cga 1 E3 GE 1200. DOW r>i E3 :I CORNING 791. I 899, 983 OR 995 SILICQN:. GE 1200. DOW WI M5 AT 1/4 POINTS ON LITES W M5 AT 1/4 POINTS ON LITES ® 91, N CORNING OR 983 OR 995 WIDER THAN 36" WIDER THAN 36" TA GLASS TYPE `(' fk GLASS TYPE 'D' En899, rA 7/16" OVERALL LAM. GLASS 7/16" OVERALL LAM. GLASS (L.M.I. & S.M.I.) M4 (L-M.1- ONLY) IN ORDER TO QUALIFY FOR SMALL MISSILE IMPACT RATING EXTERIOR PLY OF GLASS TYPES *Cl' & `D1' MUST BE TEMPERED. .075" Saflex CP With PET Core .075" Saflex CP With PET Core 3/16" ANN. GLASS By 'Eastman Chemical Co.' Interlayer 3/16" HEAT By 'Eastman Chemical Co.' Interlayer .090" Saflex Clear And Color Glass STREN'D GLASS .090" Saflex Clear And Color Glass 3/8" AIR SPACE By 'Eastman Chemical Co.' Interlayer 3/8" AIR SPACE B 'Eastman Chemical Co.' Interia er 3/16" HEAT .090" Interlayer 5entryGlas Interlayer 3/16" HEAT .090 Interlayer 5entryGlas Interlayer 'Kuraray STREN'D OR By 'Kuraray America, Inc.' STREN'D OR By America, Inc.' TEMPERED* GLASS .090" Interlayer Trosifol PVB Interloyer TEMPERED* GLASS .090" Interlayer Trosifol PVB Interlayer By 'Kuraray America, Inc.' By 'Kuraray America, Inc.' w Zw m 3/16" HEAT STREN'D GLASS m 3/16" HEAT STREN'D GLASS SILICONE: z 'ry � c� M1 GE 1200, DOW M1 M � 51LICONE: • I CORNING 791, . I GE 1200, DOW • 899, 963 OR 995 • CORNING 791, Fd I I ...... I I r-n I I ,.,.., I' I • 899, 983 OR 995 � .� AT 1 /4 POINTS ON LITES N \'TAT1 /4 POINTS ON LITES 5S WIDER THAN .3 WIDER THAN 36" W W GLASS TYPE 'Cl' 1" OVERALL INSUL LAM. GLASS * FOR INSULATED GLASS INSTALLATIONS ABOVE 30' IN THE HVHZ, OR FOR SAFETY GLAZING APPLICATIONS PER THE FBC, THE OUTBOARD LITE (CAP) MUST BE TEMPERED. SILICONE: GE 1200, DOW CORNING 791, 899, 983 OR 995 OPTIONAL GLAZING DETAII. GLASS TYPES "Cl' & 'Dl' GLASS TYPE 'D1' I 7rtie: 1" OVERALL INSUL. LAM. GLASS I "SENTINEL" SERIES 130 FIXED WINDOW - LM PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0519.09 Expiration Date: 9/22/2025 By:: F� GAL Mia4jDade ProducYCahtrol Description: GLAZING DETAILS AGK Rote: 05/22/19 Revision: Rev. By: Rev. Dote. MINOR SHEET REFORMATTING. JR 05/07/20 Series/Model: Scale Sheet: Drawing No. Rev: PW-130 LM NTS 4 OF 7 PW130LMI-NOA I A Impact Resistant Windows & Doors 3780 W. 104th 8traa11. Hialeah, Ft 3301B Tel: 305.593.6590 1 Fat: 305.502.6592 PREPARED BY LYNN MILLE 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 (941) 480-1600 REGISTRATION #29296 YN11V No. 58705 `}OTAT�E OF d0NAL 1'E� A. LYNN MILLER, P.E. P.E.#58705 TYPICAL INSTALLATION DETAILS THESE DETAILS ARE TYPICAL ON ALL FOUR SIDES OF WINDOW TYPICAL ANCHORS: SEE ELEV. FOR SPACING (FLANGE & EQUAL LEG FRAMES) 1 — I '(Fu=163 KSI, Fy=157 KSI) l /4" DIA. ULTRACON BY 'ELCOZDEWALT' (Fu=177 KSI, I:y=155 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN. PENETRATION INTO WOOD THRU 1BY BUCKS INTO CONCRETE OR BLOCKS 1-1 /4" MIN. EMBED INTO CONCRETE (HEADS/SILL/JAMBS) 1-1/4" MIN. EMBED INTO BLOCKS (,IAMBS) n DIRECTLY INTO CONCRETE OR BLOCKS 1-1 /4" MIN. EMBED INTO CONCRETE (HEADS/SILL/JAMBS) 1-1 /4" MIN. EMBED INTO BLOCKS (JAMBS) TYPICAL EDGE DISTANCE INTO CONCRETE AND MASONRY = 2 1 /2" MIN. INTO WOOD STRUCTURE = 1" MIN. 1 /4" DIA, ULTRACON+ BY 'DEWALT' (Fu=164 KSt, Fy=148 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-3/8" MIN. PENETRATION INTO WOOD THRU 1BY BUCKS INTO CONCRETE OR BLOCKS 1-3/8" MIN. EMBED INTO CONCRETE (HEADS/SILL/JAMBS) 1-1/4" MIN. EMBED INTO HOLLOW BLOCKS (JAMBS) 1-3/4" MIN. EMBED INTO FILLED BLOCKS (JAMBS) DIRECTLY INTO CONCRETE OR BLOCKS 1-3/8" MIN. EMBED INTO CONCRETE (HEADS/SILL/JAMBS) 1-1/4- MIN. EMBED INTO HOLLOW BLOCKS (JAMBS) 1-3/4" MIN. EMBED INTO FILLED BLOCKS (JAMBS) TYPICAL EDGE DISTANCE INTO CONCRETE AND MASONRY = 1 9/16" MIN. INTO WOOD STRUCTURE = 1" MIN. #14 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS) INTO MIAMI—DADE APPROVED MULLIONS OR INTO METAL STRUCTURES (HEAD/SILL/JAMBS) (3) THREADS MIN. PENETRATION BEYOND SUBTRATE ALUMINUM: 1/8" THK. MIN (6063—T5 MIN.) STEEL: 1/8" THK. MIN. (Fy = 35 KSI MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) TYPICAL EDGE DISTANCE INTO METAL STRUCTURE = 3/4" MIN. 0 1BY WOOD BUCK NO WOOD AT HEAD, SILL OR JAMBS SG = 0.55 MIN CONCRETE AT HEAD, SILL OR JAMBS Vc = 3000 PSI MIN. C-90 HOLLOW/FILLED BLOCK AT JAMBS f'm = 2000 PSI MIN INSTALLATION DETAILS THRU 1 X WOOD BUCKS INTO CONCRETE FLANGE n TYPICAL AgCHORS SEE ELEV. " FOR SPACING EQUAL LEG INSTALLATION DETAILS THRU 2X BUCKS OR INTO WOOD STRUCTURES FLANGE TYPICAL ANCHORS SEE ELEV. 2BY WOOD BUCK FOR SPACING OR WOOD STRUCTUR 101 EQUAL LEG 2BY WOOD BUCK OR A l WOOD STRUCTURE V p �SEE TYPICAL ANCHORS ELEV." ° 1 BYJ FOR SPACING WOOD BUCK TYPICAL ANCHORS: SEE ELEV. FOR SPACING FIN FRAME 8 SM (GRADE 2 CRS) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/4- MIN. PENETRATION INTO WOOD TYPICAL _EDGE DISTANCE INTO WOOD STRUCTURE = 1" MIN. INSTALLATION DETAILS DIRECTLY INTO CONCRETE FLAIr GF 1 /4" MAX. TYPICAL ANCHOW SEE ELEV FOR SPACIN( O�_J 1 /4" MAX. SHIRTS EQUAL _LEG .a a , LO . V . 7. fa3 o ' TYPICAL ANCHORS SEE ELEV. FOR SPACING v NCHORS INSTALLATION DETAILS INTO METAL STRUCTURES OR INTO APPROVED MULLIONS FLANGE METAL STRUCTURE TYPICAL ANCHORS SEE ELEV. FOR SPACING EQUAL LEG METAL STRUCTURE TYPICAL ANCHORS SEE ELEV. FOR SPACING P ODUCT REVISED as comnlvina with the Florida ING Building Code NOA-No. 20-0519.09 Expiration Date: 9/22/2025 WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WDW. MUST SUSTAIN LOADS IMPOSED By: BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. Miampade Product ContQyl Titfe: Drawn 8y. jjh,IrnpaGl Resistant {. . . , ... _ . , XY :. z "SENTINEL" SERIES 130 FIXED WINDOW — LM AGK` 0 Windows &pours - �•' .• WMEsreoxsl R�- Description.- Date: TYPICAL INSTALLATION DETAILS 05/22/19 3T69 m,193th Seraet, Hialeah,FL 5233019 T.1: 395.39.3390 jFax: 895.3.6592r � L) J a '•, i IfaT O cif PREPARED BY LYNN MILLER Revision: Rev. By: Rev. Date. REFORMATED & ADDED ANCHOR TYPE JR 05/07/20 1070 TECHNOLOGY DRIVE: N. VENICE, FL 34275 (941) 480-1600 .. , SerieslModel: Scale: Sheet: Drawing No. Rev. PW-130 LM NTS 5 OF 7 PW130LMI—NOA A REGISTRATION #29296 A, LYNN MILLER, P.E. P.E.# 58705 TYPICAL INSTALLATION DETAILS THESE DETAILS ARE TYPICAL ON ALL FOUR SIDES OF WINDOW INSTALLATION DETAILS THRU 1 X WOOD BUCKS INTO CONCRETE FLANGE ADAPTOR @� ! ! m r .w I1i � ■::1■TiT1 � 4 , p a o TYPICAL ANCHORS ,• SEE ELEV. 1 BYJ FOR SPACING WOOD BUCK MIAMI-DADE COUNTY APPROVED MULLION EQUAL LEG & MULLION ANCHORS SEE SEPARATE NOA% FI #14 x 1" SMS. INSTALLATION DETAILS THRU 2X BUCKS OR INTO WOOD STRUCTURES FLANGE ADAPTOR 2BY WOOD BUCK OR WOOD STRUC' NOT BY CGI INSTALLATION DETAILS INTO METAL FF_mIAMI—DADE COUNTY APPROVED STRUCTURES OR INTO APPROVED MULLIONS MULLION & MULLION ANCHORS II SEE SEPARATE NOA fI FLANGE ei TYPICAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS SEE ELEV. rno SPACING FTN FRAME 1 /4" MAX. PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0519.09 Ex�-r]a��tion Date:A9/22/2025 By: V' ✓ J Miam made Produc�t'C rol INSTALLATION DETAILS DIRECTLY INTO CONCRETE FLANGE ADAPTOR 1 /4" MAX. TYPICAL ANCHOR! SEE ELEV FOR SPACIN( 0 INSTALLATION DETAILS THRU FIN INTO WOOD STRUCTURES 1 /4" MAX. ' itie: "SENTINEL" SERIES 130 FIXED WINDOW - LM Description. - TYPICAL INSTALLATION DETAILS CONT. INSTALLATION DETAILS INTO METAL STRUCTURES OR INTO APPROVED MULLIONS FLANGE ADAPTOR METAL STRUCTURE FIN FRAME TYPICAL ANCHORS SEE ELEV, FOR SPACING 2 3/8' MIN. cl:>-<- 2 3/8' MIN. WHEN USED THE MIN. WOOD BUCK DEPTH SHALL BE 2%". THE USE OF DEEPER OR BEVELED WOODBUCKS IS PERMITTED. Drawn By Impact ResistantAGK Windows & Doors 0 . Date: WM STRORM- 'CJ-. 05/22/1 3780 W. lO3.6 9[reel, 8feleah, FL 33818 Tel: 306.693.6698 Fax: 305.593. b59R711 - /e f Revision: Rev. By. Rev. Dote: PREPARED BY LYNN MILLER f Q A)''OP r 1070 TECHNOLOGY DRIVE :.. REFO RMATED & ADDED ANCHOR TYPE JR 05/07/20 N. v1=NICE, FL 34275 Series/Model: Scale: Sheet: Drawing No. Rev 941 480-1600 J /ON I"� s` PW-130 LM NTS 6 OF 7 PW130LMI-NOA A ? REGISTRATION #29296 1 A. LYNN MILLER, P-E. P.E.# 58705 1.995 EN FLANGE FRAME FLUSH FRAME/FIN FRAME F1.37 i•-.180 .050 1— .065 8 FLUSH FRAME COVER 2 1.000 125 .500 -" M4 GLAZING ANGLE (LAM. INSUL. GLASS) 1.450 .1 BO .050 .550 GLAZING BEAD (LAM. GLASS) E6 FLANGE ADAPTOR -�{ �.120 J 9qTYP. 291 .050 1.081 184� E4 GLAZING BEAD (LAM. INSUL. GLASS) M2 SCREW COVER 1 30 ITEM PART # QUANTITY DESCRIPTION MAT19RIAL MANF./SUPPLIER/REMARXS E1 CGI-118 4/ WOW. FLANGE FRAME 6063-T6 - E2 CGI-119 4/ WDW, FLUSH FRAME/FIN FRAME 6063-T6 - E3 CGI-121 4/ WOW. GLAZING BEAD (LAM. GLASS) 6063-T6 - E4 CGI--123 4/ WDW. GLAZING BEAD (LAM. INSUL. GLASS) 6063-T6 - E5 CGI-110 4/ WDW. NAIL FIN ADAPTOR 6063-T6 - E6 CGI-109 4/ WDW, FRONT FLANGE ADAPTOR 6063-T6 - M1 CGI-382V AS READ. GLAZING BULB VINYL PVC DUROMETER 75-80 SHORE A M2 CGI-124 AS READ. SCREW COVER- OPTIONAL PVC - M3 CGI-112 AS READ. FLUSH FRAME COVER PVC - M4 - OPTIONAL GLAZING ANGLE (1 X 1 /2 X 1 /8") 6063-T5 - M5 - 2/ LITE SETTING BLOCKS EPDM DUROMETER 85:b5 SHORE A S2 #10 X 1-1/4" 2/ CORNER ASSEMBLY SCREW PHL. PH SMS ST/ST - CIRCULAR WINDOWS WELDED JOINT AT ENDS RECT. OR SQUARE WINDOWS TYP. CORNER DETAILS ] 1 ( ���.-• ��yilllfiil , .050 Trtfe: Brawn 8y: Impact Resistant 9 395 "SENTINEL" SERIES 130 FIXED WINDOW — LM AGK [)Windows & Doors`. E5 o - dvp, 58705 Description: Bute: NAIL FIN ADAPTER EXTRUSIONS, BOM 05/22/19 376U W. 104« 5=e+,:, H:el+ae, F1330,® Tel: 306.593,6590 � Fae: 39S.593,659R A _ >Q PRODUCT REVISED. PREPARED BY LYNN MILLER as complying with the Florida Building Code f f U 7ATc �4 Revision: Rev. By: Rev. Bate: NOA-No. 20-0519.09 NO CHANGES THIS SHEET. JR Oal07/20 1070TECHNOLOGYORIVE N. VENIGE, FL34275 •. 0 Expiration Date: 9/22/2025 SerieslVadei: Scale. Sheet: Drawing No. Rev: By: ! (941) 480-1600 �''>, ��' Miam bade ProducYl:o rol PW-130 LM NTS 7 OF 7 PW130LM I--NOA A REGISTRATION #29296 A. LYNN MILLER, P.E. P.E.# 58705